首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到5条相似文献,搜索用时 15 毫秒
1.
Uniform suppression of fat signal is desired in clinical applications. Based on phase differences introduced by different chemical shift frequencies, Dixon method and its variations are used as alternatives of fat saturation methods, which are sensitive to B0 inhomogeneities. Iterative Decomposition of water and fat with Echo Asymmetry and Least squares estimation (IDEAL) separates water and fat images with flexible echo shifting. Periodically Rotated Overlapping ParallEL Lines with Enhanced Reconstruction (PROPELLER, alternatively termed as BLADE), in conjunction with IDEAL, yields Turboprop IDEAL (TP-IDEAL) and allows for decomposition of water and fat signal with motion correction. However, the flexibility of its parameter setting is limited, and the related phase correction is complicated. To address these problems, a novel method, BLADE-Dixon, is proposed in this study. This method used the same polarity readout gradients (fly-back gradients) to acquire in-phase and opposed-phases images, which led to less complicated phase correction and more flexible parameter setting compared to TP-IDEAL. Parallel imaging and undersampling were integrated to reduce scan time. Phantom, orbit, neck and knee images were acquired with BLADE-Dixon. Water–fat separation results were compared to those measured with conventional turbo spin echo (TSE) Dixon and TSE with fat saturation, respectively, to demonstrate the performance of BLADE-Dixon.  相似文献   

2.
Robust and fast fat suppression is a challenge in balanced steady-state free precession (SSFP) magnetic resonance imaging. Although single-acquisition phase-sensitive SSFP can provide fat-suppressed images in short scan time, phase errors, especially spatially-dependent phase shift, caused by a variety of factors may result in misplacement of fat and water voxels. In this paper, a novel phase correction algorithm was used to calibrate those phase errors during image reconstruction. This algorithm corrects phase by region growing, employing both the magnitude and the phase information of image pixels. Phantom and in vivo imagings were performed to validate the technique. As a result, excellent fat-suppressed images were acquired by using single-acquisition phase-sensitive SSFP with phase correction.  相似文献   

3.
4.

Purpose

To assess the performance and results of R2 relaxometry using a fat-suppressed (FS) multiecho sequence and compare these to conventional R2 relaxometry in estimating tissue iron overload.

Materials and Methods

Relaxation rate values (R2=1/T2) of the liver, spleen, pancreas and vertebral bone marrow (VBM) were estimated in 21 patients with β-thalassemia major, using a respiratory-triggered 16-echo Carr-Purcell-Meiboom-Gill (CPMG) spin-echo sequence before (R2) and after (R2 FS) the application of chemically selective fat suppression.

Results

Hepatic and splenic R2 FS values correlated with respective R2 values (r=0.98 and r=0.96, P<.001), whereas correlations between R2 FS and R2 values for pancreas and VBM were not statistically significant. Bland–Altman plots show disagreement between R2 and R2 FS values, particularly for pancreas and VBM. Hepatic, pancreatic and VBM R2 FS values correlated with serum ferritin (r=0.88, P<.001; r=0.51, P<.003; and r=0.75, P<.002, respectively). Hepatic R2 FS values correlated with splenic R2 FS (r=0.77, P<.03), pancreatic R2 FS (r=0.61, P<.006) and VBM R2 FS values (r=0.70, P<.001), whereas pancreatic R2 FS values correlated also with VMB R2 FS values. On the contrary, among the R2 values of the above tissues, obtained without fat suppression, only hepatic R2 values correlated with serum ferritin, whereas no correlation was documented between hepatic and pancreatic or VBM R2 values. The application of fat suppression did not improve breathing or flow artifacts.

Conclusion

Application of fat suppression in the standard CPMG sequence improved the capability of MRI in noninvasive quantification of iron, particularly in lipid-rich tissues, such as vertebral bone marrow (VBM) and pancreas.  相似文献   

5.
A novel 3D breath-held Dixon fat–water separated balanced steady state free precession (b-SSFP) sequence for MR cholangiopancreatography (MRCP) is described and its potential clinical utility assessed in a series of patients. The main motivation is to develop a robust breath-held alternative to the respiratory gated 3D Fast Spin Echo (FSE) sequence, the current clinical sequence of choice for MRCP. Respiratory gated acquisitions are susceptible to motion artifacts and blurring in patients with significant diaphragmatic drift, erratic respiratory rhythms or sleep apnea. A two point Dixon fat–water separation scheme was developed which eliminates signal loss arising from B0 inhomogeneity effects and minimizes artifacts from perturbation of the b-SSFP steady state. Preliminary results from qualitative analysis of 49 patients demonstrate robust performance of the 3D Dixon b-SSFP sequence with diagnostic image quality acquired in a 20–24 s breath-hold.  相似文献   