1.
Desorption electrospray ionisation (DESI) has been successfully combined with a hybrid quadrupole time-of-flight mass spectrometer to provide mass spectra and product ion mass spectra of active ingredients formulated in pharmaceutical tablets, gels and ointments. Accurate mass data has been obtained from the DESI mass spectra and of the product ion fragments of selected ions, greatly enhancing the selectivity and information content of the experiment. This accurate mass information only takes seconds to acquire since the DESI technique does not require any sample preparation or extraction prior to mass analysis.  相似文献   

2.
Desorption electrospray ionization mass spectrometry (DESI-MS) was applied for the first time to the analysis of semivolatile organic compounds (SVOC) in atmospheric aerosols. We took polycyclic aromatic hydrocarbons (PAHs) as representatives of SVOCs. The DESI-MS conditions were optimized and the limit of detection for PAHs was about 10 pg with 5 s sampling time. PAHs from both laboratory-made biomass burning aerosols and ambient aerosols were selectively and rapidly analyzed without extraction or preconcentration. The observed PAH species and their relative ion intensities are discussed. This work demonstrates that DESI-MS is a promising method for rapid semiquantitative analysis of SVOC in atmospheric aerosols.  相似文献   

3.
The cytochalasin class of fungal metabolites was analyzed by electrospray ionization tandem mass spectrometry (ESI-MS/MS) with the aim of developing a methodology for their rapid identification in microbial extracts. ESI-MS analyses of reference cytochalasins were performed and several product ions were produced in MS/MS experiments on parent ions that are structurally characteristic. A precursor ion search was performed to detect cytochalasins in an ethyl acetate extract of fungal strain RK97-F21. Three cytochalasins were detected and one of the components was identified as epoxycytochalasin H by comparing the tandem mass spectra of the product ions with those of reference compounds. This finding was further validated by LC/MS and LC/MS/MS experiments.  相似文献   

4.
5.
The recently developed technique of desorption electrospray ionization (DESI) has been applied to the rapid analysis of controlled substances. Experiments have been performed using a commercial ThermoFinnigan LCQ Advantage MAX ion-trap mass spectrometer with limited modifications. Results from the ambient sampling of licit and illicit tablets demonstrate the ability of the DESI technique to detect the main active ingredient(s) or controlled substance(s), even in the presence of other higher-concentration components. Full-scan mass spectrometry data provide preliminary identification by molecular weight determination, while rapid analysis using the tandem mass spectrometry (MS/MS) mode provides fragmentation data which, when compared to the laboratory-generated ESI-MS/MS spectral library, provide structural information and final identification of the active ingredient(s). The consecutive analysis of tablets containing different active components indicates there is no cross-contamination or interference from tablet to tablet, demonstrating the reliability of the DESI technique for rapid sampling (one tablet/min or better). Active ingredients have been detected for tablets in which the active component represents less than 1% of the total tablet weight, demonstrating the sensitivity of the technique. The real-time sampling of cannabis plant material is also presented.  相似文献   

6.
Surfactant-mediated matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF-MS) has been used for the identification of flavonoids from three berry extracts: lowbush blueberry (Vaccinium angustifolium), lingonberry (Vaccinium vitis-idaea), and blackberry (Rubus armeniacus). The addition of the surfactant led to suppression of matrix ions from both alpha-cyano-4-hydroxycinnamic acid (CHCA) and 2',4',6'-trihydroxyacetophenone (THAP). This is the first case of this method being successfully employed with a matrix other than CHCA. It was observed that CHCA led to a great deal of fragmentation of the sugar moiety from glycosides, whereas THAP produced more intact glycoside molecules, and thus leads to better characterization of the flavonoids in a berry sample. The flavonoids were characterized and quantified by liquid chromatography/electrospray ionization mass spectrometry (LC/ESI-MS) with UV detection. Although MALDI-TOF-MS did not lead to the identification of as many flavonoids, it did enable us to identify many anthocyanin glycosides. Quantification was achieved and demonstrated that use of the THAP matrix can enable quantification of the intact glycosides with relative standard deviation (RSD) values of less than 10% with surfactant addition. These results are comparable with LC results. MALDI-TOF-MS with THAP matrix thus provided a rapid method for the qualitative screening of these compounds. It took only a few minutes, greatly reducing the analysis time from that in traditional LC/MS methods.  相似文献   

7.
Rezenom YH  Dong J  Murray KK 《The Analyst》2008,133(2):226-232
We have used an infrared laser for desorption of material and ionization by interaction with electrosprayed solvent. Infrared laser-assisted desorption electrospray ionization (IR LADESI) mass spectrometry was used for the direct analysis of water-containing samples under ambient conditions. An ion trap mass spectrometer was modified to include a pulsed Er:YAG laser at 2.94 microm wavelength coupled into a germanium oxide optical fiber for desorption at atmospheric pressure and a nanoelectrospray source for ionization. Analytes in aqueous solution were placed on a stainless steel target and irradiated with the pulsed IR laser. Material desorbed and ablated from the target was ionized by a continuous stream of charged droplets from the electrosprayed solvent. Peptide and protein samples analyzed using this method yield mass spectra similar to those obtained by conventional electrospray. Blood and urine were analyzed without sample pretreatment to demonstrate the capability of IR LADESI for direct analysis of biological fluids. Pharmaceutical products were also directly analyzed. Finally, the role of water as a matrix in the IR LADESI process is discussed.  相似文献   

8.
9.
In vivo skin analysis by Desorption Electrospray Ionization was characterized on healthy human volunteers by directing pneumatically assisted electrospray directly onto their fingertips. In order to eliminate the risk of electric shock, a high ohmic resistor was built into the system. Positive ion DESI-MS analysis yields low intensity spectra, while negative ion spectra feature a number of various biogenic carboxylic acids. Compounds of external origin and excreted molecules were found to have different analysis kinetics, with the exception of highly hydrophobic species. The difference was demonstrated in the case of nicotine and cotinine. Pharmacokinetic studies were performed using a rat animal model. The kinetics of the anesthetic ketamine was followed by DESI, and results were in agreement with off-line HPLC-MS blood analysis. Using a similar approach for N,N'-dimethylthiourea (DMTU), a novel method was developed for the real-time quantification of oxidative stress. DMTU was administered to the animals, and the ratio of the molecule and its oxidized form was monitored from the skin surface. The ratio was found to be highly sensitive to experimentally induced diabetes mellitus type I and angiotensin-induced chronic oxidative stress. It was concluded that the method has a number of potential applications in the fields of forensics, pharmacology and clinical chemistry.  相似文献   

10.
A newly developed high-throughput desorption electrospray ionization (DESI) source was characterized in terms of its performance in quantitative analysis. A 96-sample array, containing pharmaceuticals in various matrices, was analyzed in a single run with a total analysis time of 3 min. These solution-phase samples were examined from a hydrophobic PTFE ink printed on glass. The quantitative accuracy, precision, and limit of detection (LOD) were characterized. Chemical background-free samples of propranolol (PRN) with PRN-d7 as internal standard (IS) and carbamazepine (CBZ) with CBZ-d10 as IS were examined. So were two other sample sets consisting of PRN/PRN-d7 at varying concentration in a biological milieu of 10% urine or porcine brain total lipid extract, total lipid concentration 250 ng/μL. The background-free samples, examined in a total analysis time of 1. 5 s/sample, showed good quantitative accuracy and precision, with a relative error (RE) and relative standard deviation (RSD) generally less than 3% and 5%, respectively. The samples in urine and the lipid extract required a longer analysis time (2. 5 s/sample) and showed RSD values of around 10% for the samples in urine and 4% for the lipid extract samples and RE values of less than 3% for both sets. The LOD for PRN and CBZ when analyzed without chemical background was 10 and 30 fmol, respectively. The LOD of PRN increased to 400 fmol analyzed in 10% urine, and 200 fmol when analyzed in the brain lipid extract.  相似文献   

11.
12.
13.
14.
Electrospray ionization multi-stage tandem mass spectrometry (ESI-MS(n)) and liquid chromatography coupled with on-line mass spectrometry (LC/MS/MS) were applied to characterize saponins in crude extracts from Panax ginseng. The MS(n) data of the [M - H](-) ions of saponins can provide structural information on the sugar sequences of the saccharide chains and on the sapogins of saponins. By ESI-MS(n), non-isomeric saponins and isomeric saponins with different aglycones can be determined rapidly in plant extracts. LC/MS/MS is a good complementary analytical tool for determination of isomeric saponins. These approaches constitute powerful analytical tools for rapid screening and structural assignment of saponins in plant extracts.  相似文献   

15.
Trimethyamine (TMA) and trimethylamine N-oxide (TMAO) are the most important urine parameters for diagnosing and monitoring trimethylaminuria. A rapid, simple, and specific method based on matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOFMS) was developed to determine the presence of TMA and TMAO in urine samples from patients with trimethylaminuria. Formation of the quaternary tetramethylamino iodide by derivatization of TMA with methyl iodide allows measurement of TMA by MALDI-TOFMS. The method is repeatable and reproducible, with coefficients of variance (CVs)<3%. This new method was used for direct determination of TMA and TMAO in urine specimens obtained from normal children and patients. The proposed method allows for rapid and reliable measurements of TMA and TMAO in urine specimens from patients affected by trimethylaminuria.  相似文献   

16.
An integrated method of liquid chromatography-heated electrospray ionization/tandem mass spectrometry was evaluated for high throughput screening of various abused drugs in urine. Chromatographic analysis was performed on a C18 reverse phase column using a linear gradient of 10 mM ammonium acetate containing 0.1% formic acid-methanol as mobile phase and the total separation time was 7 min. A simple and rapid sample preparation method used was by passing urine samples through a 0.22 μm PVDF syringe filter. The detection limits of the studied abused drugs in urine were from 0.6 ng mL−1 (ketamine) to 9.0 ng mL−1 (norcodeine). According to the results, the linear range was from 1 to 1200 ng mL−1 with relative standard deviation (R.S.D.s) value below 14.8% (intra-day) and 24.6% (inter-day). The feasibility of applying the proposed method to determine various abused drugs in real samples was examined by analyzing urine samples from drug-abused suspects. The abused drugs including ketamines and amphetamines were detected in suspected urine samples. The results demonstrate the suitability of LC-HESI-MS/MS for high throughput screening of the various abused drugs in urine.  相似文献   

17.
A rapid method was developed to identify and quantify the azide ion (N(3)(-)) in gastric fluid and urine. N(3)(-) in diluted biological fluids was reacted with NaAuCl(4) to produce Au(N(3))(2)(-), which was extracted with octanol. Five microliters of the extract were flow-injected into an electrospray ionization tandem mass spectrometric instrument. Quantification of N(3)(-) was performed by selected reaction monitoring of the product ion Au(N)(N(3))(-) at m/z 253, which was derived from the precursor ion Au(N(3))(2)(-) at m/z 281, using 50 μL of aqueous solution within 10 min. This method was found to be linear up to 10(-5) M, to have a limit of quantification of 10(-7) M, a limit of detection of 3.0?×?10(-8) M, and a coefficient of variation of ≦10% at 10(-7) M. In the case of urine, 50 μL of urine were spiked with N(3)(-), this was diluted 10-fold and passed through 1 mL of a resin, and finally diluted to 100-fold of the original. This method was linear up to 10(-3) M, had a limit of quantification of 10(-5) M, a limit of detection of 3.0?×?10(-6) M, and coefficient of variation of ≦8.8% for an original urine concentration of 10(-5) M. The practical applicability of this method was checked by diluting 1 μL of a suspected suicide victim's gastric fluid 20,000-fold and 1 μL of the victim's urine 5,000-fold and then measuring the N(3)(-) levels. These levels were found to be (7.5?±?1.0)?×?10(-2) M and (3.2?±?0.4)?×?10(-3) M, respectively.  相似文献   

18.
Mass spectrometry (MS) is an effective analytical tool for high-throughput screening (HTS) in the drug discovery field. Infrared matrix-assisted laser desorption electrospray ionization (IR-MALDESI) MS is a high-throughput platform that has achieved analysis times of sub-seconds-per-sample. Due to the high-throughput analysis speed, methods are needed to increase the analyte signal while decreasing the variability in IR-MALDESI-MS analyses to improve data quality and reduce false-positive hits. The Z-factor is used as a statistic of assay quality that can be improved by reducing the variation of target ion abundances or increasing signal. Herein we report optimal solvent compositions for increasing measured analyte abundances with direct analysis by IR-MALDESI-MS. We also evaluate normalization strategies, such as adding a normalization standard that is similar or dissimilar in structure to the model target drug, to reduce the variability of measured analyte abundances with direct analyses by IR-MALDESI-MS in both positive and negative ionization modes.  相似文献   

19.
Desorption electrospray ionization mass spectrometry (DESI-MS) is applied to the analysis of carbohydrates and steroids; the detection limits are significantly improved by the addition of low concentrations of salts to the spray solvent.  相似文献   