首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 36 毫秒
1.
Laser-induced desorption/ionization from silicon nanowires (SiNW) is an emerging method for mass spectrometry of small to medium-size molecules. In this new technique, we examined the internal energy transfer to seven benzylpyridinium thermometer ions and extracted the corresponding internal energy distributions. To explore the effect of the energy-deposition rate on the internal energy transfer, two lasers with significantly different pulse lengths (4 ns vs 22 ps) were utilized as excitation sources. A comparison of ion yields indicated that the SiNW substrates required 5-8 times less laser fluence for ion production than either matrix-assisted laser desorption/ionization (MALDI) or desorption/ionization on silicon (DIOS). In contrast however, the survival yield (SY) values showed that the internal energy transferred to the thermometer ions was more than (ps laser) or comparable to (ns laser) MALDI but it was significantly less than in DIOS. The internal energy transfer was only slightly dependent on laser fluence and on wire density. These effects were rationalized in terms of the confinement of thermal energy in the nanowires and of unimpeded three-dimensional plume expansion. Unlike in MALDI from CHCA and in perfluorophenyl-derivatized DIOS, for desorption from SiNWs the effect of laser pulse length on the internal energy transfer was found to be negligible.  相似文献   

2.
High surface area of porous silicon drives desorption of intact molecules   总被引:1,自引:1,他引:0  
The surface structure of porous silicon used in desorption/ionization on porous silicon (DIOS) mass analysis is known to play a primary role in the desorption/ionization (D/I) process. In this study, mass spectrometry and scanning electron microscopy (SEM) are used to examine the correlation between intact ion generation with surface ablation and surface morphology. The DIOS process is found to be highly laser energy dependent and correlates directly with the appearance of surface ions (Si(n)(+) and OSiH(+)). A threshold laser energy for DIOS is observed (10 mJ/cm(2)), which supports that DIOS is driven by surface restructuring and is not a strictly thermal process. In addition, three DIOS regimes are observed that correspond to surface restructuring and melting. These results suggest that higher surface area silicon substrates may enhance DIOS performance. A recent example that fits into this mechanism is the surface of silicon nanowires, which has a high surface energy and concomitantly requires lower laser energy for analyte desorption.  相似文献   

3.
In matrix-assisted laser desorption/ionization (MALDI), the true molecular structures of some analytes are not represented by the observed ions due to a redox reaction. In earlier reports, electron transfer from analyte to chemical matrix has been proposed for the oxidation of ferrocene derivatives in MALDI. To address such a redox phenomenon in laser desorption/ionization processes, two ferrocene derivatives, FcCH2CH2Fc and FcCH2NMe2 [Fc:(CsHs)Fe(CsH4)], were analyzed by a matrix-free method, desorption/ionization on porous silicon (DIOS). The oxidized species, Fc+CH2NMe2 and FcCH2CH2Fc+, were detected in the DIOS mass spectra. The results suggested that electron transfer from the analytes to the sample target occurs during the ionization process.  相似文献   

4.
Reduction of analytes in matrix-assisted laser desorption/ionization (MALDI) often obscures the actual determination of molecular structure. To address the redox reactions in laser desorption/ionization processes, the organic dyes Methylene Blue, Janus Green B, Crystal Violet and Rhodamine B were analyzed by MALDI or by desorption/ionization on porous silicon (DIOS). Susceptibility to reduction in MALDI was dependent on both the reduction potentials of analytes and the molar ratio of analyte to matrix molecules. Addition of Cu(II) ions as an electron scavenger suppressed the reduction of Methylene Blue in MALDI. The results suggested that electron transfer to analytes from the sample target and/or from the matrix contributed to the reduction. In DIOS, the reductions of organic dyes were more prominent than in MALDI, and were not prevented by Cu(II) ion doping, probably due to direct contact of the analytes with silicon which had little electric resistance.  相似文献   

5.
We gauged the internal energy transfer for two dissociative ion decomposition channels in matrix-assisted laser desorption ionization (MALDI) using the benzyltriphenylphosphonium (BTP) thermometer ion [PhCH 2PPh 3] (+). Common MALDI matrixes [alpha-cyano-4-hydroxycinnamic acid (CHCA), 3,5-dimethoxy-4-hydroxycinnamic acid (sinapinic acid, SA), and 2,5-dihydroxycinnamic acid (DHB)] were studied with nitrogen laser (4 ns pulse length) and mode-locked 3 x omega Nd:YAG laser (22 ps pulse length) excitation. Despite the higher fluence required to initiate fragmentation, BTP ions indicated lower internal energy transfer with the picosecond laser in all three matrixes. These differences can be rationalized in terms of phase explosion induced by the nanosecond laser vs a stress-confinement-driven desorption mechanism for the picosecond laser. For the two ion production channels of the BTP thermometer ion, breaking a single bond can result in the formation of benzyl/tropylium ions, F1, or triphenylphosphine ions, F2. In SA and DHB, as well as in CHCA at low fluence levels, the efficiency of these channels (expressed by the branching ratio I F1/ I F2) is moderately in favor of producing tropylium ions, 1 < I F1/ I F2 < 6. As the laser fluence is increased, for CHCA, there is a dramatic shift in favor of the tropylium ion production, with I F1/ I F2 approximately 30 for the nanosecond and the picosecond laser, respectively. This change is correlated with the sudden increase in the BTP internal energies in CHCA in the same laser fluence range. The large changes observed in internal energy deposition for CHCA with laser fluence can account for its ability to induce fragmentation in peptides more readily than SA and DHB.  相似文献   

6.
A comparative analysis of the laser desorption/ionization of vitamin B12 by matrix-assisted laser desorption/ionization (MALDI) and desorption/ionization on porous silicon (DIOS) was carried out. The mass spectra obtained were interpreted and the pathways for ion formation and decomposition were established. The MALDI fragmentation of the positive vitamin B12 ions is more extensive than the DIOS fragmentation. The most extensive fragmentation was found using the MALDI method for negative vitamin B12 ions, which are lacking when using the DIOS method. __________ Translated from Teoreticheskaya i éksperimental’naya Khimiya, Vol. 43, No. 4, pp. 251–256, July–August, 2007.  相似文献   

7.
This study focuses on porous silicon (pSi) fabrication methods and properties for desorption ionization on silicon mass spectrometry (DIOS-MS). PSi was prepared using electrochemical etching of n-type silicon in HF-ethanol solution. Porous areas were defined by a double-sided illumination arrangement: front-side porous areas were masked by a stencil mask, eliminating the need for standard photolithography, and backside illumination was used for the backside ohmic contact. Backside illumination improved the uniformity of the porosified areas. Porosification conditions, surface derivatizations and storage conditions were explored to optimize pSi area, pore size and pore depth. Chemical derivatization of the pSi surfaces improved the DIOS-MS performance providing better ionization efficiency and signal stability with lower laser energy. Droplet spreading and drying patterns on pSi were also examined. Pore sizes of 50-200 nm were found to be optimal for droplet evaporation and pore filling with the sample liquid, as measured by DIOS efficiency. With DIOS, significantly better detection sensitivity was obtained (e.g. 150 fmol for midazolam) than with desorption ionization from a standard MALDI steel plate without matrix addition (30 pmol for midazolam). Also the noise that disturbs the detection of low-molecular weight compounds at m/z < 500 with MALDI could be clearly reduced with DIOS. Low background MS spectra and good detection sensitivity at the 100-150 fmol level for pharmaceutical compounds were achieved with DIOS-MS.  相似文献   

8.
Cysteine sulfonic acid-containing peptides, being typical acidic peptides, exhibit low response in matrix-assisted laser desorption/ionization (MALDI) mass spectrometry. In this study, matrix conditions and the effect of diammonium hydrogencitrate (DAHC) as additive were investigated for ionization of cysteine sulfonic acid-containing peptides in MALDI. A matrix-free ionization method, desorption/ionization on porous silicon (DIOS), was also utilized to evaluate the effect of DAHC. When equimolar three-component mixtures of peptides carrying free cysteine, cysteine sulfonic acid, and carbamidomethyl cysteine were measured by MALDI using a common matrix, alpha-cyano-4-hydroxycinnamic acid (CHCA), no signal corresponding to cysteine sulfonic acid-containing peptide could be observed in the mass spectrum. However, by addition of DAHC to CHCA, the peaks of cysteine sulfonic acid-containing peptides were successfully observed, as well as when using 2,4,6-trihydroxyacetophenone (THAP) and 2,6-dihydroxyacetophenone with DAHC. In the DIOS mass spectra of these analytes, the use of DAHC also enhanced the peak intensity of the cysteine sulfonic acid-containing peptides. On the basis of studies with these model peptides, tryptic digests of oxidized peroxiredoxin 6 were examined as a complex peptide mixture by MALDI and DIOS. In MALDI, the peaks of cysteine sulfonic acid-containing peptides were observed when using THAP/DAHC as the matrix, but this was not so with CHCA. In DIOS, the signal from cysteine sulfonic acid-containing peptides was suppressed; however, the use of DAHC significantly enhanced the signal intensity with an increase in the number of observed peptides and increased signal-to-noise ratio in the DIOS spectra. The results show that DAHC in the matrix or on the DIOS chip decreases discrimination and suppression effects in addition to suppressing alkali-adduct ions, which leads to a beneficial effect on protonation of peptides containing cysteine sulfonic acid.  相似文献   

9.
硅片类型和多孔硅结构的多样性影响了多孔硅表面的激光解吸/离子化质谱(DIOS)(无辅助基质的激光解吸/电离飞行时间质谱(LDI-TOF-MS))数据的重复性和靶的耐储时间。本工作通过在多孔硅的表面淀积金纳米颗粒并将其作为目标靶来增强软物质分子如聚乙二醇和多肽的激光解吸/电离质谱信号。纳米金的淀积钝化了多孔硅表面的Si-H活性基团,增加了靶的耐储时间。用场发射扫描电镜表征了多孔硅淀积金纳米颗粒前后的形貌,用X射线能量色散光谱法分析金的百分含量,结果表明其含量随沉积时间的延长而增加。激光解吸/电离质谱信号的增强可能是由多孔硅及其支持的金纳米颗粒的光学和物理性质引起的,该类型的样品靶在激光解吸/电离飞行时间质谱的应用上结合了多孔硅和金纳米颗粒的双重优势。  相似文献   

10.
We investigated a variant of desorption/ionization on porous silicon (DIOS) mass spectrometry utilizing an aqueous suspension of either porous silica gel or porous alumina (pore size of 60 and 90 A, respectively). Laser desorption/ionization (LDI) from samples directly deposited on a stainless steel surface without any inorganic substrates was also achieved. Synthetic peptides designed to cover large sequence diversity constituted our model compounds. Sample preparation, including material conditioning, peptide solubilization, and deposition protocol onto standard matrix-assisted laser desorption/ionization (MALDI) probe, as well as ionization source tuning were optimized to perform sensitive reproducible LDI analyses. The addition of either a cationizing agent or an alkali metal scavenger to the sample suspension allowed modification of the ionization output. Comparing hydrophilic silica gel to hydrophobic reversed-phase silica gel as well as increasing material pore size provided further insights into desorption/ionization processes. Furthermore, mixtures of peptides were analyzed to probe the spectral suppression phenomenon when no interfering organic matrix was present. The results gathered from synthetic peptide cocktails indicated that LDI mass spectrometry on silica gel or alumina constitutes a promising complementary method to MALDI in proteomics for peptide mass fingerprinting.  相似文献   

11.
Desorption/ionization on porous silicon (DIOS) is a very useful technique in the case of small molecular weight compounds, compared to the matrix-assisted laser desorption ionization (MALDI). This is because MALDI generates matrix-related ions that overlap with the mass range of interest. The aim of our work was to investigate the suitability of the DIOS technique in the case of fatty acids in negative ion mode. The analysis of the chosen fatty acid models, nonadecanoic acid (C(19)H(38)O(2)) and heneicosanoic acid (C(21)H(42)O(2)), gave rise to the observation of the deprotonated monomeric species and selective cationized multimeric species. This cation selectivity was further elucidated by complementary studies based on the addition of various metals such as Ag(I), Zn(II), Fe(II), and also Cu(II). Specific behavior, depending upon the introduced metal, was highlighted by different redox reaction processes and also metastable decompositions (in PSD mode).  相似文献   

12.
多孔硅表面的激光解吸离子化质谱   总被引:1,自引:0,他引:1  
多孔硅表面的解吸离子化质谱是一种新的生物质谱分析方法。克服了MALDI-TOF-MS中的基体干扰,适合进行了小分子分析。提出了新的样品制备方法,可以扩大测定范围,消除吸附杂质的干扰。发现该方法与多孔硅的光致光特性及表面疏水性无关。具有纳米结构的多孔硅作为该方法中能量的接收器。利用DIOS方法分析了氨基酸、肽、蛋白、糖等样品。此方法用于环糊精合成产物的分析,也得到了较好的结果。  相似文献   

13.
A low molecular mass polyester was analyzed by desorption/ionization on porous silicon (DIOS) mass spectrometry. The results were compared with those of matrix-assisted laser desorption ionization (MALDI) mass spectrometry using matrixes of alpha-cyano-4-hydroxycinnamic acid (CHCA) and 10,15,20-tetrakis(pentafluorophenyl)porphyrin (F20TPP). The CHCA matrix was not suitable for characterization of low molecular mass components of the polyester because the matrix-related ions interfered with the component ions. On the other hand, the F20TPP matrix showed no interference because no matrix-related ions appeared below m/z 822. However, the solvent selection for determining optimal conditions of sample preparation was limited, because F20TPP does not dissolve readily in any of the available organic solvents. In the DIOS spectra, the polymer ions were observed at high sensitivity without a contaminating ion. No matrix is needed for DIOS spectra of low molecular mass polyesters, facilitating sample preparation and selectivity of a precursor ion in post-source decay measurements.  相似文献   

14.
Reduction of analytes in ionization processes often obscures the determination of molecular structure. The reduction of analytes is found to take place in various desorption/ionization methods such as fast atom bombardment (FAB), secondary ion mass spectrometry (SIMS), matrix‐assisted laser desorption/ionization (MALDI) and desorption ionization on porous silicon (DIOS). To examine the extent of the reduction reactions taking place in electrospray droplet impact (EDI) processes, reduction‐sensitive dyes and S‐nitrosylated peptide were analyzed by EDI. No reduction was observed for methylene blue. While methyl red has a lower reduction potential than methylene blue, the reduction product ions were detected. For S‐nitrosylated peptide, protonated molecule ion [M + H]+ and NO‐eliminated molecular ion [M − NO + H]+• were observed but reduction reactions are largely suppressed in EDI compared with that in MALDI. As such, the analytes examined suffer from little reduction reactions in EDI. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

15.
Desorption/ionization on porous silicon (DIOS) is a form of laser desorption mass spectrometry that allows for the direct mass analysis of a variety of analytes without the addition of organic matrix. Protocols are described for the direct analysis of exocrine tissue and single neurons using DIOS-MS. The atrial gland of Aplysia californica was blotted on to porous silicon and analyzed with DIOS-MS in the range m/z 1000-4000. The ability to culture invertebrate neurons directly on porous silicon is also presented. Isolated bag cells regenerated neuronal processes in culture on porous silicon. DIOS-MS allowed the direct detection of the peptides contained in individual cultured neurons indicating that with appropriate protocols, DIOS can be used with biological samples with considerable thickness.  相似文献   

16.
The study of low molecular weight compounds by matrix-assisted laser desorption/ionization (MALDI) is difficult because of the presence of ions originating from the matrix in the low-m/z range. In order to resolve these problems, new matrix-free approaches were developed based on laser desorption/ionization from the surface of various materials such as graphite and porous silicon. Our work involves the use of 'desorption ionization on porous silicon mass spectrometry' (DIOS-MS) in the negative ion mode to study fatty acid compounds. The potential of the DIOS-MS technique is shown and an insight into the ionization mechanism provided.  相似文献   

17.
Atmospheric pressure laser desorption/ionization on porous silicon   总被引:3,自引:0,他引:3  
A recently developed commercial atmospheric pressure matrix-assisted laser desorption/ionization (AP-MALDI) source (MassTech, Inc.) was modified to adopt commercially available DIOS plates (Mass Consortium Corp.) for the studies of laser desorption from the surface of porous silicon under atmospheric pressure conditions. The feasibility of atmospheric pressure laser desorption/ionization from the surface of porous silicon (AP-DIOS) was demonstrated. The advantages of this new AP-DIOS technique include reasonably good sensitivity (subpicomole range for standard peptide mixtures), simplicity of sample preparation, uniformity of target spots and the absence of matrix peaks in the spectra. The AP-DIOS source was interfaced with a commercial ion trap (LCQ Classic, Thermo Finnigan) which additionally provides a unique MS(n) capability. The AP-DIOS spectrum of 250 fmol of unseparated tryptic digest of bovine serum albumin (BSA) was compared with that of AP-MALDI for the same compound. AP-DIOS offers significantly better coverage for the digest components in the mass range 200-1000 Da. The combined data of both techniques enabled us to nearly double the number of matched peaks in BSA digest analysis compared with AP-DIOS or AP-MALDI analysis separately.  相似文献   

18.
Glancing angle deposition (GLAD) was used to fabricate nanostructured silicon (Si) thin films with highly controlled morphology for use in laser desorption/ionization mass spectrometry (DIOS‐MS). Peptides, drugs and metabolites in the mass range of 150–2500 Da were readily analyzed. The best performance was obtained with 500 nm thick films deposited at a deposition angle of 85°. Low background mass spectra and attomole detection limits were observed with DIOS‐MS for various peptides. Films used after three months of dry storage in ambient conditions produced mass spectra with negligible low‐mass noise following a 15 min UV‐ozone treatment. The performance of the Si GLAD films was as good as or better than that reported for electrochemically etched porous silicon and related materials, and was superior to matrix‐assisted laser desorption/ionization (MALDI)‐MS for analysis of mixtures of small molecules between 150–2500 Da in terms of background chemical noise, detection limits and spot‐to‐spot reproducibility. The spot‐to‐spot reproducibility of signal intensities (100 shots/spectrum) from 21 different Si GLAD film targets was ±13% relative standard deviation (RSD). The single shot‐to‐shot reproducibility of signals on a single target was ±19% RSD (n = 7), with no indication of sweet spots or mute spots. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

19.
Infrared soft laser desorption/ionization was performed using a 2.94 µm Er : YAG laser and a commercial reflectron time-of-flight mass spectrometer. The instrument was modified so that a 337 nm nitrogen laser could be used concurrently with the IR laser to interrogate samples. Matrix-assisted laser desorption/ionization (MALDI), laser desorption/ionization and desorption/ionization on silicon with UV and IR lasers were compared. Various target materials were tested for IR soft desorption ionization, including stainless steel, aluminum, copper, silicon, porous silicon and polyethylene. Silicon surfaces gave the best performance in terms of signal level and low-mass interference. The internal energy resultant of the desorption/ionization was assessed using the easily fragmented vitamin B12 molecule. IR ionization produced more analyte fragmentation than UV-MALDI analysis. Fragmentation from matrix-free IR desorption from silicon was comparable to that from IR-MALDI. The results are interpreted as soft laser desorption and ionization resulting from the absorption of the IR laser energy by the analyte and associated solvent molecules. Copyright © 2004 John Wiley & Sons, Ltd.  相似文献   

20.
In this report, we describe the visible-laser desorption/ionization of biomolecules deposited on gold-coated porous silicon and gold nanorod arrays. The porous silicon made by electrochemical etching was coated with gold using argon ion sputtering. The gold nanorod arrays were fabricated by electrodepositing gold onto a porous alumina template, and the subsequent partial removal of the alumina template. A frequency-doubled/tripled Nd : YAG laser was used to irradiate the gold nanostructured substrate, and the desorbed molecular ions were mass-analyzed by a time-of-flight mass spectrometer. The desorption/ionization of biomolecules for both substrates was favored by the use of the 532-nm visible-laser, which is in the range of the localized surface plasmon resonance of the gold nanostructure. The present technique offers a potential analytical method for low-molecular-weight analytes that are rather difficult to handle in the conventional matrix-assisted laser desorption/ionization (MALDI) mass spectrometry.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号