首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
Gas chromatography/electron ionization mass spectrometry (GC/EI-MS) of N,N-dialkylaminoethyl-2-chlorides (DAAECls) and trimethylsilyl (TMS) derivatives of N,N-dialkylaminoethan-2-ols (DAAEAs) has been carried out. GC/EI-MS data of these compounds are of importance for verification of the Chemical Weapons Convention (CWC). Based on these EI mass spectra, generalized fragmentation routes are proposed that rationalize most of the characteristic ions.  相似文献   

2.
This paper describes the synthesis and gas chromatography/electron ionization mass spectrometric (GC/EI-MS) analysis of methyl esters of N,N-dialkylaminoethane-2-sulfonic acids (DAESAs). These sulfonic acids are important environmental signatures of nerve agent VX and its toxic analogues, hence GC/EI-MS analysis of their methyl esters is of paramount importance for verification of the Chemical Weapons Convention. DAESAs were prepared by condensation of 2-bromoethane sulfonic acid with dialkylamines, and by condensation of dialkylaminoethyl chloride with sodium bisulfite. GC/EI-MS analysis of methyl esters of DAESAs yielded mass spectra; based on these spectra, generalized fragmentation routes are proposed that rationalize most of the characteristic ions.  相似文献   

3.
We describe the microsynthesis and gas chromatography/mass spectrometric (GC/MS) analysis of cyclic alkylphosphonates (CAPs), which are included in schedule 2B4 chemicals in the Chemical Weapons Convention (CWC). The reported microsynthesis is efficient in comparison with traditional synthesis. GC/MS and GC/tandem mass spectrometric (MS/MS) analysis of a variety of CAPs revealed that their fragmentations were dominated by alpha-cleavages, alkene eliminations and hydrogen rearrangements. Based on the obtained mass spectra and precursor and product ion analysis of five-, six- and seven-membered cyclic alkylphosphonates, the proposed fragmentation routes rationalize most of the characteristic ions.  相似文献   

4.
The detection and identification of degradation products of scheduled chemicals, which are characteristic markers of Chemical Warfare agents (CWAs), plays a key role in verification analysis. Identification of such non-scheduled but specific markers of CWAs helps in deciphering the kind of agent that was present in the sample submitted for off-site analysis. This paper describes the stability of N,N-dialkylaminoethyl-2-chlorides, which are precursors for highly toxic chemicals like VX, in different solvents. These compounds are stable in chloroform, acetonitrile, hexane and dichloromethane but tend to undergo in situ nucleophilic substitution reaction in the presence of alcohols giving the corresponding alkyl ether. The study shows that N,N-dialkylaminoethyl alkyl ethers can be used as markers of N,N-dialkylaminoethyl-2-chlorides. A detailed degradation study of these compounds in the presence of alcohols was carried out and it was found that the reaction follows pseudo-first order kinetics. Electron ionization mass spectral data for the methyl ethers of all the compounds are briefly discussed.  相似文献   

5.
Gas chromatography-mass spectrometry (GC-MS) analysis of O,O'-dialkyl methylphosphonites (DAMPs) was carried out with a view to developing a database and understanding the mechanism of fragmentation. DAMPs are included in the list of schedule 2B4 chemicals of the Chemical Weapons Convention. GC-MS analysis of DAMPs and their deuterated analogs revealed that their fragmentations were dominated by α-cleavages, alkenyl radical loss and hydrogen rearrangements. Based on fragment ions of deuterated analogs and density functional theory calculations, the fragmentation routes were rationalized.  相似文献   

6.
This communication describes the synthesis and gas chromatography/mass spectrometric (GC/MS) analysis of N,N-dialkylphosphoramidic dihalides and alkylphosphonic difluorides, which are synthones of nerve agents. The study was undertaken with a view to developing a spectral database of these compounds for verification purposes of the Chemical Weapons Convention (CWC). The modified synthetic approach reported here has advantages over traditional syntheses in terms of time and yield. GC/MS analysis of these synthones yielded electron ionization (EI) mass spectra and, based on these spectra, generalized fragmentation routes are proposed that rationalize most of the characteristic ions.  相似文献   

7.
Retrospective detection and identification of markers of chemical warfare agents are important aspects of verification of the Chemical Weapons Convention. Alkyl alkylphosphonic acids (AAPAs) and alkylphosphonic acids (APAs) are important markers of nerve agents. We describe the development and optimization of a new gas chromatography/mass spectrometry (GC/MS) injection port fluorination method for the derivatization of AAPAs and APAs. The process involved the injection of acids with trifluoroacetic anhydride in GC/MS, where acids are converted into their corresponding volatile fluorides. Various reaction conditions such as fluorinating agent, injection port temperature and splitless time were optimized. The maximum reaction efficiency of the acids with trifluoroacetic anhydride was observed at 230 degrees C injection port temperature with a splitless time of 2 min. APAs showed best analytical efficiencies at 400 degrees C injection port temperature, while the other conditions were similar to those of AAPAs. The linearities of response for APAs and AAPAs were in the range of 1-25 and 5-100 microg mL(-1), respectively, with limits of detection ranging from 500 pg to 800 ng mL(-1).  相似文献   

8.
Bonaga  G.  Chiavari  G.  Verardo  G. 《Chromatographia》1989,27(11):596-600
Chromatographia - We have studied the gas chromatographic behaviour of several 3-methyl-2-benzothiazolone-azines. In HPLC analysis all the unsymmetrical azines show double peaks, whereas in HRGC...  相似文献   

9.
10.
The stable carbon isotope compositions of tetrols, erythritol and threitol were determined by gas chromatography/combustion/isotope ratio mass spectrometry (GC/C/IRMS). Using four tetrols with various δ13C values derivatized by methylboronic acid, the carbon isotope analysis method achieved excellent reproducibility and high accuracy. There was no carbon isotopic fractionation during the derivatization processes. The differences in the carbon isotopic compositions of methylboronates between the measured and calculated ranged from ?0.20 to 0.12‰, within the specification of the GC/C/IRMS system. It was demonstrated that δ13C values of tetrols could be calculated by a simple mass balance equation between tetrols, methylboronic acid, and methylboronates. The analogous 2‐methyltetrols, marker compounds of photooxidation products of atmospheric isoprene, should have similar behavior using the same derivatization reagent. This method may provide insight on sources and sinks of atmospheric isoprene. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

11.
The analysis of nitrogen containing amino alcohols, which are the precursors and degradation products of nitrogen mustards and nerve agent VX, constitutes an important aspect for verifying the compliance to the CWC (Chemical Weapons Convention). This work devotes on the development of solid-phase extraction method using silica- and polymer-based SCX (strong cation-exchange) and MCX (mixed-mode strong cation-exchange) cartridges for N,N-dialkylaminoethane-2-ols and alkyl N,N-diethanolamines, from water. The extracted analytes were analyzed by GC-MS (gas chromatography-mass spectrometry) in the full scan and selected ion monitoring modes. The extraction efficiencies of SCX and MCX cartridges were compared, and results revealed that SCX performed better. Extraction parameters, such as loading capacity, extraction solvent, its volume, and washing solvent were optimized. Best recoveries were obtained using 2 mL methanol containing 10% NH(4)OH and limits of detection could be achieved up to 5 x 10(-3) microg mL(-1) in the selected ion monitoring mode and 0.01 microg mL(-1) in full scan mode. The method was successfully employed for the detection and identification of amino alcohol present in water sample sent by Organization for Prohibition of Chemical Weapons (OPCW) in the official proficiency tests. The method was also applied to extract the analytes from human plasma. The SCX cartridge showed good recoveries of amino alcohols from human plasma after protein precipitation.  相似文献   

12.
13.
To obtain accurate values of delta(13)C(CO(2)) and delta(18)O(CO(2)) on environmental CO(2) by mass spectrometry, the raw isotope data must be corrected for the isobaric N(2)O contribution. This is one of the analytical problems limiting inter-laboratory delta(13)C(CO(2)) data consistency. The key parameter, the N(2)O relative ionisation efficiency (E(N2O)), cannot be determined with sufficient accuracy by direct measurements of pure N(2)O. The determination of (E(N2O)) by analyses on N(2)O--CO(2) mixtures of known isotope composition and mixing proportions has been recently suggested. In this work we propose a new method of N(2)O correction which uses the m/z 30 signal as a measure of the N(2)O/CO(2) ratio, so that determinations of (E(N2O)) and N(2)O content are not required. The method uses the fact that fragment-ion spectra of N(2)O and CO(2) are very specific. The formalism of the correction is considered. Various tests demonstrate that the new method is robust, stable and easy to implement in practice. The effective value (E(N2O)) (the key parameter for the new correction) has to be calibrated on known N(2)O--CO(2) mixtures by measuring (30)R signals only. The method accuracy we presently achieved is around 2.5% and any error which appears to come mostly from our N(2)O--CO(2) mixture preparation. Based on our tests and error considerations, the error of the proposed method that may be achieved is as low as +/-1.5% (relative to the correction magnitude). For tropospheric CO(2) this means +/-0.003 per thousand and +/-0.005 per thousand for delta(13)C(CO(2)) and delta(18)O(CO(2)), respectively. The proposed method may be valuable for small samples where no separate N(2)O determinations are available (e.g. ice core samples and CF-IRMS measurements) as well as for determination of (E(N2O)) and testing the 'traditional' N(2)O correction based on mass balance calculations.  相似文献   

14.
Protein glycosylation has a significant medical importance as changes in glycosylation patterns have been associated with a number of diseases. Therefore, monitoring potential changes in glycan profiles, and the microheterogeneities associated with glycosylation sites, are becoming increasingly important in the search for disease biomarkers. Highly efficient separations and sensitive methods must be developed to effectively monitor changes in the glycoproteome. These methods must not discriminate against hydrophobic or hydrophilic analytes. The use of activated graphitized carbon as a desalting media and a stationary phase for the purification and the separation of glycans, and as a stationary phase for the separation of small glycopeptides, has previously been reported. Here, we describe the use of activated graphitized carbon as a stationary phase for the separation of hydrophilic tryptic glycopeptides, employing a chip‐based liquid chromatographic (LC) system. The capabilities of both activated graphitized carbon and C18 LC chips for the characterization of the glycopeptides appeared to be comparable. Adequate retention time reproducibility was achieved for both packing types in the chip format. However, hydrophilic glycopeptides were preferentially retained on the activated graphitized carbon chip, thus allowing the identification of hydrophilic glycopeptides which were not effectively retained on C18 chips. On the other hand, hydrophobic glycopeptides were better retained on C18 chips. Characterization of the glycosylation sites of glycoproteins possessing both hydrophilic and hydrophobic glycopeptides is comprehensively achieved using both media. This is feasible considering the limited amount of sample required per analysis (<1 pmol). The performance of both media also appeared comparable when analyzing a four‐protein mixture. Similar sequence coverage and MASCOT ion scores were observed for all proteins when using either stationary phase. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

15.
16.
The mass spectra of trimethylsilyl (TMS) derivatives of possible hydroxylated pyrolysis products of glucose and cellulose were recorded by gas chromatography/mass spectrometry (GC/MS) analyses of TMS derivatives of 2-hydroxymethylfuran, 2-hydroxy-1-methyl-1-cyclopenten-3-one, 5-(hydroxymethyl)-2-furaldehyde, 5-methyl-2-furoic acid, 4-hydroxy-6-methyl-(2H)-pyran-2-one, 2-methyl-3-hydroxy-(4H)-pyran-4-one (maltol) and 1,6-anhydro-beta-D-glucopyranose (levoglucosan, LG). Also, 2-O-TMS-1,6-anhydro-beta-D-glucopyranose, 4-O-TMS-1,6-anhydro-beta-D-glucopyranose and 2,4-bis-O-TMS-1,6-anhydro-beta-D-glucopyranose were identified from the interpretation of electron impact and chemical ionisation mass spectra of products obtained from partially silylated levoglucosan solutions, together with information from the known relative reactivities of OH groups of anhydrosugars. A peak at m/z 116 was found to be characteristic of the mass spectra of partially silylated anhydrosugars, and is absent from the mass spectra of the persilylated species. Pyrolysis/GC/MS of cellulose in the presence of hexamethyldisilazane afforded principally the 2- and 4-TMS ethers and the 2,4-bis-TMS ether of LG, whereas the 5-TMS-oxymethyl-2-furaldehyde was a prominent pyrolysis/silylation product of glucose. The mass spectra of other relevant pyrolysis/silylation products are presented.  相似文献   

17.
The headspace compositions of 13 pepper and peppercorn samples of different species, colloquially also referred to as pepper, were analyzed, and more than 300 compounds were tentatively characterized by means of comprehensive two-dimensional gas chromatography in tandem with flame ionization detection, quadrupole mass spectrometric detection and time-of-flight mass spectrometric detection (GC x GC-FID, GC x GC/qMS and GC x GC/TOFMS, respectively). The analysis of volatile organic compounds (VOCs) was performed after solid-phase microextraction (SPME) using a 75-microm PDMS/DVB fibre. Fingerprint comparison between the three techniques permitted peaks to be assigned in the GC x GC-FID experiment based on the analogous MS analysis, taking into account retention shifts arising from method variations. When using GC x GC/TOFMS, about five times more peaks were identified than in GC x GC/qMS. Retention indices for all peaks were calculated in the bi-dimensional column set comprising of a 5% phenyl polysilphenylene-siloxane primary column and a polyethylene glycol second column. The spectra obtained by both mass detection techniques (qMS and TOFMS) give very similar results when spectral library searching was performed. The majority of the identified compounds eluted as pure components as a result of high-resolution GC x GC separations, which significantly reduces co-elution, and therefore increases the likelihood that pure spectra can be obtained. The differences between TOFMS and qMS (in fast scanning mode) spectra were generally small. Whilst spectral quality and relative ion ratios across a narrow peak (e.g. w(b) approximately 100-150 ms) do vary more for the fast peaks obtained in GC x GC/qMS operation, than with TOFMS, in general adequate spectral matching with the library can be achieved.  相似文献   

18.
A gas chromatography/ion trap mass spectrometry (GC/ITMS) method was developed for the determination of polybrominated diphenyl ethers (PBDEs). ITMS parameters were optimized in order to achieve the best sensitivity for the PBDE analysis. Tandem mass spectrometry, along with an isotope dilution internal standard method, was used for the quantitation. Chromatographic windows were developed for mono- to hepta-BDEs, depending on the retention times when a 30-m GC column was used. A different 15-m column was used to analyze deca-BDE. Environmental soil samples collected from an electronic waste recycling site were prepared by using Soxhlet extraction and column chromatographic cleanup. Average recoveries of 61-118% were obtained for the 13C-labeled PBDE internal standards spiked in the samples prior to sample preparation. The accuracy represented by relative analytical errors was -24% to 18%, and the precision (relative standard deviation) was 11-26% (n=8). The method detection limits ranged from 0.013-0.25 ng/g for the PBDEs in soil.  相似文献   

19.
In liquid chromatography/mass spectrometry (LC/MS) of 1,3,5-trinitro-1,3,5-triazacyclohexane (RDX), attachment of an anion to the analyte molecule is the major way of producing characteristic ions under electrospray ionization (ESI) and atmospheric pressure chemical ionization (APCI) conditions. The formation of RDX cluster ions in LC/MS and the origin of the clustering agents have been studied. In order to determine whether the clustering anions originate from self-decomposition of RDX in the source or from impurities in the mobile phase, isotopically labeled RDX ((13)C(3)-RDX and (15)N(6)-RDX) and isotopically labeled glycolic acid, acetic acid, ammonium formate and formaldehyde have been used in order to establish the composition and formation route of RDX adduct ions produced in ESI and APCI sources. The results showed that, in ESI, self-decomposition of RDX plays no role in adduct ion formation; rather, RDX clusters with formate, acetate, hydroxyacetate, and chloride anions present in the mobile phase as impurities at ppm levels. In APCI, part of the RDX molecules decompose yielding NO(2) (-) species which in turn cluster with a second RDX molecule producing abundant [M+NO(2)](-) cluster ions.  相似文献   

20.
Analysis of several polar and non-polar compounds is performed with a newly developed dual electrospray ionization/atmospheric pressure photoionization (ESI/APPI) or ESPI source. Several variables are considered in the source, such as ESI probe heater temperature, solvent flow, dopant effects, repeller plate voltage, source geometry and photon energy (Kr vs. Ar lamp). Direct photoionization resulting in a molecular radical cation [M](*+) dominates at high temperatures (>400 degrees C) and low flow rates (<200 microL/min). Indirect photo-induced chemical ionization (PCI) involving solvent molecules becomes important at lower temperatures and higher solvent flow rates. Indirect PCI is enhanced using an Ar lamp, which yields comparable [M+H](+) signal but poorer [M](*+) signal than the Kr lamp at lower temperatures and higher flow rates. This is in support of our recent finding that the Ar lamp results in a solvent-dependent enhancement of analyte molecules via PCI. Analysis of 12 compounds in methanol under low-flow conditions (10 microL/min) demonstrates that the dual ESPI source performs favorably for most compounds versus the standard ESCI source, and significantly better than ESCI for the analysis of unstable drugs, like flurbiprofen. Several factors contributing to the benefits of the ESPI source are the shared optimal geometry for ESI and APPI sources and soft ionization of APPI versus APCI.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号