1.
Eeltink S  Rozing GP  Kok WT 《Electrophoresis》2003,24(22-23):3935-3961
The most recent and important applications in capillary electrochromatography (CEC) are summarized, covering literature published since May 2001. A selection of new developments in stationary phases for CEC is highlighted, and enantiomeric separations and chiral stationary phases are discussed. Also, CEC applications of biological molecules, pharmaceuticals, and applications in the field of industrial and environmental analysis are summarized. For this review three modes of CEC were taken into account, i.e., packed-column CEC, CEC using monolith technology, and open-tubular CEC.  相似文献   

2.
Gübitz G  Schmid MG 《Electrophoresis》2004,25(23-24):3981-3996
This review summarizes recent developments in chiral separation in capillary zone electrophoresis (CZE), electrokinetic chromatography (EKC), and capillary electrochromatography (CEC) covering literature published since the year 2000. New chiral selectors and innovative approaches for CE and CEC are introduced. Recent progress in column technology for CEC is highlighted and the development of new chiral stationary phases is discussed. This review is not dedicated to list applications but will focus on new developments.  相似文献   

3.
El Rassi Z 《Electrophoresis》1999,20(15-16):3134-3144
This review article is concerned with the recent developments in capillary electrophoresis (CE) and capillary electrochromatography (CEC) of carbohydrates. The literature shows that CE possesses impressive potential in the analysis of carbohydrates. On the other hand, CEC has just started to show promise in the analysis of carbohydrates. Advances in separation and detection approaches of derivatized and underivatized carbohydrates are discussed based on the available literature. In addition, important applications are illustrated.  相似文献   

4.
Gübitz G  Schmid MG 《Electrophoresis》2007,28(1-2):114-126
This review gives an overview of recent developments in CZE, EKC, and CEC covering the literature since the year 2004. Since there appeared a special issue on applications, this review focuses on the progress in electromigration techniques and new methodological developments. New techniques, new chiral selectors as well as new chiral stationary phases for CEC are discussed.  相似文献   

5.
A review is presented on the current state of the art and future trends in the development of sol-gel stationary phases for capillary electrochromatography (CEC). The design and synthesis of stationary phases with prescribed chromatographic and surface charge properties represent challenging tasks in contemporary CEC research. Further developments in CEC as a high-efficiency liquid-phase separation technique will greatly depend on new breakthroughs in the area of stationary phase development. The requirements imposed on CEC stationary phase performance are significantly more demanding compared with those for HPLC. The design of CEC stationary phase must take into consideration the structural characteristics that will provide not only the selective solute/stationary phase interactions leading to chromatographic separations but also the surface charge properties that determine the magnitude and direction of the electroosmotic flow responsible for the mobile phase movement through the CEC column. Therefore, the stationary phase technology in CEC presents a more complex problem than in conventional chromatographic techniques. Different approaches to stationary phase development have been reported in contemporary CEC literature. The sol-gel approach represents a promising direction in this important research. It is applicable to the preparation of CEC stationary phases in different formats: surface coatings, micro/submicro particles, and monolithic beds. Besides, in the sol-gel approach, appropriate sol-gel precursors and other building blocks can be selected to create a stationary phase with desired structural and surface properties. One remarkable advantage of the sol-gel approach is the mild thermal conditions under which the stationary phase synthesis can be carried out (typically at room temperature). It also provides an effective pathway to integrating the advantageous properties of organic and inorganic material systems, and thereby enhancing and fine-tuning chromatographic selectivity of the created hybrid organic-inorganic stationary phases. This review focuses on recent developments in the design, synthesis, characterization, properties, and applications of sol-gel stationary phases in CEC.  相似文献   

6.
Ou J  Dong J  Dong X  Yu Z  Ye M  Zou H 《Electrophoresis》2007,28(1-2):148-163
This review summarizes most of the recent developments in the preparation and application of polar stationary phases for CEC covering the literature published since the year 2004. These polar stationary phases have been adopted for separation of analytes by the modes of packing column CEC, open-tubular CEC (o-CEC) and monolithic column CEC. Currently, development of o-CEC using biomolecules, such as protein and DNA, as the immobilized ligands is highlighted partly due to the simplicity of preparation. Furthermore, monolithic columns have been extended quickly, particularly inorganic materials-based monoliths, such as silica, zirconia, hafnium, etc., as an alternative to packed columns have been developed quickly.  相似文献   

7.
Review coupling of capillary electrochromatography to mass spectrometry   总被引:3,自引:0,他引:3  
This review discusses the development of capillary electrochromatography (CEC) coupled to mass spectrometric (MS) detection over the last few years. Major topics addressed are instrumental setups employed and applications of this technology published in the recent literature. The instrumental section includes a discussion of the most commonly used interfaces for the hyphenation of CEC and MS as well as ionization techniques. Applications reviewed in this paper come from a variety of different fields such as the analysis of biomolecules like proteins, peptides, amino acids or carbohydrates, chiral separations or the analysis of pharmaceutical an their metabolites in a series of matrices.  相似文献   

8.
Capillary electrochromatography of peptides and proteins   总被引:1,自引:0,他引:1  
Li Y  Xiang R  Wilkins JA  Horváth C 《Electrophoresis》2004,25(14):2242-2256
This paper reviews recent progress in bioanalysis using capillary electrochromatography (CEC), especially in the field of separation of proteins and peptides. Fundamentals of CEC are briefly discussed. Since most of the recent developments on CEC have focused on column technology, i.e., design of new stationary phases and development of new column configurations, we describe here a variety of column architectures along with their advantages and disadvantages. Newly emerged column technologies in CEC for high speed and high efficiency separation are also discussed. Different analytical platforms of CEC such as pressure-assisted CEC or voltage-assisted micro- high-performance liquid chromatography (HPLC), CEC with different detection techniques, CEC on microchip platforms and multidimensional electrochromatography with their applications in peptide and protein analysis are presented.  相似文献   

9.
Liu CY 《Electrophoresis》2001,22(4):612-628
An overview of the most recent developments in column technology employed in capillary electrophoresis (CE) and capillary electrochromatography (CEC), mainly for the separation of small molecules and ions, is presented. Particular emphasis is laid on permanent coating. The wall modification methods in CE include covalent modification, adsorbed coatings and polymeric coatings, while those in CEC include packed columns, open-tubular columns and fritless columns. A short discussion on the characterization and selectivity of the bonded phases is also given.  相似文献   

10.
田耘  曹小敏  张琪  曾昭睿 《色谱》2009,27(6):737-744
超分子化学是一门研究分子间特定识别能力的新兴学科,超分子化合物所具有的主-客体识别能力为高选择性的色谱分离提供了广阔的发展前景。毛细管电色谱是近年来发展起来的一种高效、高选择性的微分离技术,电色谱固定相是该技术的核心部分,一直是研究的热点。本文综述了1998年以来环糊精、杯芳烃、冠醚以及大环多胺等4种超分子化合物用作毛细管电色谱固定相的研究进展情况。  相似文献   

11.
A review is presented of the most important recent applications of capillary electrochromatography (CEC) for the analysis of acidic, basic, and neutral compounds, of biomolecules, environmental substances, natural products, pharmaceuticals, and chiral compounds. Packed-column CEC (packed-CEC), open-tubular (OT-CEC), as well as pressure-assisted CEC (pseudo-CEC) are hereby considered. Papers published between July 1999 and April 2001 were taken into account. Applications before July 1999 have been reviewed in Electrophoresis 1999, 20, 3027-3065.  相似文献   

12.
毛细管电色谱联用技术的研究进展   总被引:1,自引:0,他引:1  
林子俺  庞纪磊  黄慧  张兰  陈国南 《色谱》2010,28(3):273-283
毛细管电色谱(CEC)作为一种新型微柱分离技术,具有高效、高选择性、高分辨率和快速分离等特点。由于CEC进样体积通常为纳升级,所以对检测系统的高灵敏检测提出了很高的要求。当前,发展CEC与各种高灵敏检测器的联用已成为CEC研究中最活跃的方向之一。本文简要介绍了CEC研究的发展历程,系统综述了CEC与各类检测器联用技术及其在复杂样品分离分析中应用的最新进展,并对CEC联用技术的前景进行了展望。引用文献141篇。  相似文献   

13.
毛细管电色谱和加压毛细管电色谱的进展与应用   总被引:2,自引:1,他引:1  
毛细管电色谱(CEC)以内含色谱固定相的毛细管为分离柱,以电渗流为驱动力,既可以分离带电物质也可以分离中性物质。它结合了毛细管电泳和高效液相色谱两者的优点,兼具高柱效、高分辨率、高选择性和高峰容量的特点,同时具有色谱和电泳的双重分离机理。然而,“纯粹”的电色谱在实际应用中有着天然的弱点,即: 在电流通过毛细管柱中的流动相时容易产生气泡(焦耳热作用),从而使电流中断和电渗流停止,毛细管柱必须被重新用流动相润湿后方能再次使用。加压毛细管电色谱(pCEC)将液相色谱中的压力流引入CEC系统中,不仅解决了气泡、干柱等问题,而且实现了定量阀进样和二元梯度洗脱。CEC和pCEC作为微分离领域的两种前沿技术,满足了当前复杂样品分析和分析仪器微型化的需求,近年来获得了广泛的关注。本文综述了这两种技术近来的发展,包括仪器、色谱固定相的发展,总结了其在生命科学、药物分析、食品安全以及环保样品分析等方面的应用进展,评述了各方法的特点,并展望了CEC和pCEC今后的发展和应用前景。  相似文献   

14.
Capillary electroendoosmotic chromatography of peptides   总被引:1,自引:0,他引:1  
This review focuses on the current state of peptide separation by capillary electroendoosmotic chromatography (CEC). When carried out under optimised conditions, peptide separation by CEC methods represents an orthogonal and complementary technique to micro-HPLC (micro-HPLC) and high-performance capillary zone electrophoresis (HPCZE). The origin of the selectivity differences that can be achieved with these three separation techniques (CEC, micro-HPLC and HPCZE), respectively are discussed, and the current limits of performance with CEC methods documented. Peptide separations by CEC methods with n-alkyl bonded silicas or mixed-mode phases are also illustrated. The development of different variants of CEC and pressurised CEC (also commonly referred to in the literature as electrically-assisted micro-HPLC) are examined. The potential of coupling CEC systems to mass spectrometers for real-time analyses of peptides or protein digests has been examined. Several future directions for the application of this technique in phenotype/proteomic and zeomic mapping of naturally occurring peptides and proteins are highlighted.  相似文献   

15.
Capillary electrochromatography (CEC), which combines the advantages of the high efficiency of capillary electrophoresis (CE) and the high selectivity of liquid chromatography (LC), has recently received considerable attention. Most CEC experiments have been performed with capillary columns packed with small LC packing materials (1.5–5 μm particle diameter). However, problems such as difficulties in packing the small LC packing materials and fabricating the frits still exist in preparing the CEC column. The use of open-tubular columns in CEC is therefore an alternative approach that can eliminate the problems encountered in packed-column CEC. So far, several types of open-tubular columns have been proposed for CEC separations and in this article recent progress in this area is reviewed.  相似文献   

16.
The review summarizes recent developments in enantioseparations by capillary electrochromatography (CEC). Selected fundamental aspects of CEC are discussed in order to stress those features which may allow the success of this technique in the competitive field of enantioseparations. In addition, the comparative characteristics of the different modes of chiral CEC and the stationary phases are presented. The effects of the characteristics of the stationary and liquid phases and operational conditions on the separation results are discussed. Finally, some future trends are briefly addressed.  相似文献   

17.
毛细管电色谱技术研究进展   总被引:3,自引:0,他引:3  
毛细管电色谱是一种新型的微分离技术,它结合了毛细管电泳和高效液相色谱的优点,近年来越来越受到分析化学家的关注。本文介绍了近几年来毛细管电色谱技术取得的最新进展,包括填充柱、开管柱、整体柱电色谱的色谱柱制备技术,压力驱动电色谱技术,毛细管电色谱的检测技术及样品预富集技术,指出了存在的问题并展望了电色谱发展前景。  相似文献   

18.
Recent advances in capillary electrophoresis (CE) and capillary electrochromatography (CEC) separation, detection and sample preparation methodologies applied for the determination of a variety of pollutants is overviewed. The reviewed literature illustrates the wide range of CE applications, indicating the continuing interest in CE and CEC in the environmental field.  相似文献   

19.
A review on the advantages, peculiarities, and the potential of enantioselective capillary electrochromatography (CEC) in nonaqueous media is presented. Some fundamentals on CEC with particular focus on enantioselective CEC are discussed. The strategies, concepts, preferentially utilized chiral selectors and column technologies that have been utilized to succeed in highly efficient enantiomer separations by nonaqueous CEC are described thoroughly.  相似文献   

20.
金属有机框架材料(MOFs)是一类由金属离子或金属簇与有机官能团通过配位键形成的新型有机-无机杂化晶态多孔材料, 具有比表面积大、热稳定性和化学稳定性高、结构及功能多样等特点, 是毛细管电色谱(CEC)领域研究较多且具有优异应用前景的一类新型纳米材料固定相.综述了近年来MOFs在CEC中的研究进展, 主要包括新型制柱技术的发展及其在分离领域的应用, 并对该领域今后的发展方向进行了展望.  相似文献   