首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 312 毫秒
1.
Polypropylene hollow fibers as the adsorbent were directly filled into a polyetheretherketone tube for in‐tube solid‐phase microextraction. The surface properties of hollow fibers were characterized by a scanning electron microscope. Combined with high performance liquid chromatography, the extraction tube showed good extraction performance for five environmental estrogen hormones. To achieve high analytical sensitivity, four important factors containing sampling volume, sampling rate, content of organic solvent in sample, and desorption time were investigated. Under the optimum conditions, an online analysis method was established with wide linear range (0.03–20 µg/L), good correlation coefficients (≥0.9998), low limits of detection (0.01–0.05 µg/L), low limits of quantitation (0.03–0.16 µg/L), and high enrichment factors (1087–2738). Relative standard deviations (n = 3) for intraday (≤3.6%) and interday (≤5.1%) tests proved the stable extraction performance of the material. Durability and chemical stability of the extraction tube were also investigated, relative standard deviations of all analytes were less than 5.8% (n = 3), demonstrating the satisfactory stability. Finally, the method was successfully applied to detect estrogens in real samples.  相似文献   

2.
The residues and abuse of antibiotics have seriously endangered ecological balance and human health; meanwhile, antibiotics determination is very difficult because of their low levels and multiple categories in complicated matrices. Appropriate sample pretreatment is usually imperative to enrich (ultra)trace antibiotics and eliminate matrix interference prior to chromatographic analysis. Dispersive liquid-liquid microextraction (DLLME) has become an ideal pretreatment technique owing to its simplicity, effectiveness, low-consumption, etc. In this work, an ultrasonic-assisted DLLME (UA-DLLME) was developed for the simultaneous extraction of seven sulfonamides (SAs) antibiotics in environmental water and seafood samples coupled with HPLC-DAD determination. Several parameters affecting UA-DLLME efficiency were systematically optimized, and consequently the SAs were separated and detected within 14.5 min. The obtained limits of detection (LODs) and limits of quantification (LOQs) ranged from 0.7–7.8 μg/L and 2.4–26.0 μg/L for three water samples (seawater, aquaculture wastewater and lake water) and two seafood samples (pomfrets and shrimps). High recoveries (80.0–116.0%) with low relative standard deviations (0.1–8.1%) were achieved for all the tested samples at three spiked levels. Notably, sulfadimethoxine was found at 24.49 μg/L in one seawater sample. The facile, robust and benign DLLME-HPLC method demonstrated promising perspectives for multiresidue analysis of antibiotics.  相似文献   

3.
Two cheap, simple and reproducible methods for the electrophoretic determination of homocysteine thiolactone (HTL) in human urine have been developed and validated. The first method utilizes off-line single drop microextraction (SDME), whereas the second one uses off-line SDME in combination with field amplified sample injection (FASI). The off-line SDME protocol consists of the following steps: urine dilution with 0.2 mol/L, pH 8.2 phosphate buffer (1:2, v/v), chloroform addition, drop formation and extraction of HTL. The pre-concentration of HTL inside a separation capillary was performed by FASI. For sample separation, the 0.1 mol/L pH 4.75 phosphate buffer served as the background electrolyte, and HTL was detected at 240 nm. A standard fused-silica capillary (effective length 55.5 cm, 75 μm id) and a separation voltage of 21 kV (~99 μA) were used. Electrophoretic separation was completed within 7 min, whereas the LOD and LOQ for HTL were 0.04 and 0.1 μmol/L urine, respectively. The calibration curve in urine was linear in the range of 0.1–0.5 μmol/L, with R2 = 0.9991. The relative standard deviation of the points of the calibration curve varied from 2.4% to 14.9%. The intra- and inter-day precision and recovery were 6.4–10.2% (average 6.0% and 6.7%) and 94.9–102.7% (average 99.7% and 99.5%), respectively. The analytical procedure was successfully applied to the analysis of spiked urine samples obtained from apparently healthy volunteers.  相似文献   

4.
An analytical method for extraction and quantitative determination of amygdalin, prunasin, and sambunigrin in plant material is described. The method is based on extraction with high-power ultrasound (UAE), with acidified water as solvent and quantification by HPLC–DAD. The best extraction conditions were: 80% sonication amplitude, 55 s extraction time, 70% duty cycle, 0.1 g sample mass, and 10 mL acidified water (0.1% perchloric acid). Once developed, the method was validated in terms of accuracy and precision. Good linearity was obtained, with correlation coefficients exceeding 0.999 and the quantification limits ranged from 2.2 μg/g (amygdalin) to 9.6 μg/g (sambunigrin). The accuracy (recovery study) ranged between 90 and 104% and the reproducibility of the method was always <2.3% (RSD). Special attention should be paid to the ratio sample/solvent in samples with potential β-glucosidase activity to avoid degradation of the cyanogenic glycosides (CNGs). The proposed method was used to evaluate the content of CNGs in kernels of Prunus genera, apple seeds, apple pomace, and different plant materials of Sambucus nigra.  相似文献   

5.
The efficient capture of multi-pollutant residues in food is vital for food safety monitoring. In this study, in-situ-fabricated magnetic MIL-53(Al) metal organic frameworks (MOFs), with good magnetic responsiveness, were synthesized and applied for the magnetic solid-phase extraction (MSPE) of chloramphenicol, bisphenol A, estradiol, and diethylstilbestrol. Terephthalic acid (H2BDC) organic ligands were pre-coupled on the surface of amino-Fe3O4 composites (H2BDC@Fe3O4). Fe3O4@MIL-53(Al) MOF was fabricated by in-situ hydrothermal polymerization of H2BDC, Al (NO3)3, and H2BDC@Fe3O4. This approach highly increased the stability of the material. The magnetic Fe3O4@MIL-53(Al) MOF-based MSPE was combined with high-performance liquid chromatography-photo diode array detection, to establish a novel sensitive method for analyzing multi-pollutant residues in milk. This method showed good linear correlations, in the range of 0.05–5.00 μg/mL, with good reproducibility. The limit of detection was 0.004–0.108 μg/mL. The presented method was verified using a milk sample, spiked with four pollutants, which enabled high-throughput detection and the accuracies of 88.17–107.58% confirmed its applicability, in real sample analysis.  相似文献   

6.
Dispersive liquid-liquid microextraction (DLLME) was combined with high-performance liquid chromatography-diode-array detector (HPLC-DAD) for the extraction and quantitation of three major capsaicinoids (i.e. capsaicin, dihydrocapsaicin and nordihydrocapsaicin) from pepper (Capsicum annuum L.). Chloroform (extraction solvent, 100 μL), acetonitrile (disperser solvent, 1250 μL) and 30 s extraction time were found optimum. The analytes were back-extracted into 300 μL of 50 mM sodium hydroxide/ methanol, 45/55% (v/v), within 15 s before being injected into the instrument. Enrichment factors ranged from 3.3 to 14.7 and limits of detection from 5.0 to 15.0 µg g-1. Coefficients of determination (R2) and %RSD were higher than 0.9962 and lower than 7.5%, respectively. The proposed method was efficiently applied for the extraction and quantitation of the three capsaicinoids in six cultivars of Capsicum annuum L. with percentage relative recoveries in the range of 92.0%–108.0%. DLLME was also scaled up for the isolation of the three major capsaicinoids providing purity greater than 98.0% as confirmed by liquid chromatography-mass spectrometry (LC-MS) and nuclear magnetic resonance (NMR) analysis, which significantly reduced the extraction time and organic solvent consumption.  相似文献   

7.
Resorcinol–formaldehyde aerogel coating was in situ prepared on the surface of basalt fibers. The aerogel coating is uniformly modified onto basalt fibers, and it is very porous according to the characterization by using scanning electron microscopy. An extraction tube was prepared for in‐tube solid‐phase microextraction by placing the aerogel‐coated basalt fibers into a polyetheretherketone tube. To evaluate the extraction performance toward five estrogenic compounds, the tube was connected with high performance liquid chromatography, the important extraction and desorption conditions were investigated. An online analytical method for detection of estrogens was developed and presented low limits of detection (0.005–0.030 µg/L), wide linear ranges (0.017–20, 0.033–20, and 0.099–20 µg/L), good linearity (r > 0.9990), and satisfactory repeatability (relative standard deviation < 2.7%). The method was successfully applied to detect trace estrogens in real water samples (bottled pure water and bottled mineral water), satisfactory recoveries were ranged from 80 to 125% with two spiking levels of 2 and 6 µg/L.  相似文献   

8.
Tenebrio molitor larvae (mealworm) is an edible insect and is considered a future food. Using liquid chromatography-tandem mass spectrometry (LC-MS/MS), a novel method for simultaneous analysis of 353 target analytes was developed and validated. Various sample preparation steps including “quick, easy, cheap, effective, rugged, and safe” (QuEChERS) extraction conditions, number of acetonitrile-hexane partitions, and dispersive-solid phase extraction (dSPE) sorbents were compared, and the optimal conditions were determined. In the established method, 5 g of homogenized mealworms was extracted with acetonitrile and treated with QuEChERS EN 15662 salts. The crude extract was subjected to three rounds of acetonitrile-hexane partitioning, and the acetonitrile layer was cleaned with C18 dSPE. The final solution was matrix-matched and injected into LC-MS/MS (2 μL). For target analytes, the limits of quantitation (LOQs) were ≤10 μg/kg, and the correlation coefficient (r2) of calibration was >0.990. In recovery tests, more than 90% of the pesticides showed an excellent recovery range (70–120%) with relative standard deviation (RSD) ≤20%. For more than 94% of pesticides, a negligible matrix effect (within ±20%) was observed. The analytical method was successfully applied and used for the detection of three urea pesticides in 4 of 11 mealworm samples.  相似文献   

9.
Owing to the high toxicity of polycyclic aromatic hydrocarbons (PAHs) and their low content in the environment, the development of efficient analysis methods is very important. In this work, an extraction tube was developed through filling barium sulfate nanoparticle-coated basalt fibers (BFs) in a poly(ether ether ketone) (PEEK) tube. According to the characterization result by scanning electron microscopy, BFs were evenly covered with barium sulfate nanoparticles, and their diameter was about 11 µm. To sensitively determine PAHs, the extraction tube was connected to a high-performance liquid chromatography instrument with diode array detector for an online enrichment and detection method. By optimizing sampling volume, sampling rate, the content of methanol in sample and desorption time, the analysis method provided a wide linear range (0.30–20 µg L??1) and high enrichment ratio (71–2095), and was useful for the efficient detection of PAHs in environmental aqueous samples.  相似文献   

10.
A determination method for trace 24-epibrassinolide (EBL) in plant tissues was developed using ultra-high-performance liquid chromatography–tandem mass spectrometry (UPLC-MS/MS). The plant tissue samples were extracted using a methanol–formic acid solution, and the corresponding supernatant was purified with ODS C18 solid-phase extraction column. The extracts were separated using a Zorbax Eclipse Plus C18 (2.1 mm × 50 mm, 1.8 μm) column with methanol and 0.1% formic acid as the mobile phase. The ion source for the mass spectrometry was an electrospray ionization source with positive ion mode detection. The linear range of the target compound was 0.7~104 μg/kg, the limit of detection (LOD) was 0.11~0.37 μg/kg, the limit of quantification (LOQ) was 0.36~1.22 μg/kg, the recovery rate was 84.0~116.3%, and the relative standard deviation (RSD%) was 0.8~10.5. The samples of maize plumule, brassica rapeseed flower, and marigold leaf were detected using the external standard method. The optimization of the extraction method and detection method of EBL improved the detection sensitivity, laid a foundation for the artificial synthesis of EBL, improved the extraction rate of EBL, and provided a theoretical basis for the study of EBL in many plants.  相似文献   

11.
Determination of valproic acid in the drug was carried out on the aluminum silica gel 60F254 plates and using acetone–water–chloroform–ethanol–ammonia at a volume ratio of 30:1:8:5:11 as the mobile phase, respectively. Two methods of detection of valproic acid were used. The first was a 2% aqueous CuSO4×5H2O solution, and the second was a 2′,7′-dichlorofluorescein-aluminum chloride-iron (III) chloride system. The applied TLC-densitometric method is selective, linear, accurate, precise, and robust, regardless of the visualizing reagent used for the determination of valproic acid in Convulex capsules. It has low limits of detection (LOD) and limits of quantification (LOQ), which are equal to 5.8 μg/spot and 17.4 μg/spot using a 2% aqueous CuSO4×5H2O solution as visualizing agent and also 0.32 μg/spot and 0.97 μg/spot using a 2′,7′-dichlorofluorescein-aluminum chloride-iron (III) chloride system as visualizing reagent, respectively. The described analytical method can additionally be used to study the identity of valproic acid in a pharmaceutical preparation. The linearity range was found to be 20.00–80.00 μg/spot and 1.00–2.00 μg/spot for valproic acid detected on chromatographic plates using a 2% aqueous CuSO4×5H2O solution and the 2′,7′-dichlorofluorescein-aluminum chloride-iron (III) chloride system, respectively. A coefficient of variation that was less than 3% confirms the satisfactory accuracy and precision of the proposed method. The results of the assay of valproic acid equal 96.2% and 97.0% in relation to the label claim that valproic acid fulfill pharmacopoeial requirements. The developed TLC-densitometric method can be suitable for the routine analysis of valproic acid in pharmaceutical formulations. The proposed TLC-densitometry may be an alternative method to the modern high-performance liquid chromatography and square wave voltammetry in the control of above-mentioned substances, and it can be applied when other analytical techniques is not affordable in the laboratory.  相似文献   

12.
Salvia officinalis L. (sage) is one of the most appreciated plants for its plethora of biologically active compounds. The objective of our research was a comparative study, in the Mediterranean context, of chemical composition, anticholinesterases, and antioxidant properties of essential oils (EOs) from sage collected in three areas (S1–S3) of Southern Italy. EOs were extracted by hydrodistillation and analyzed by gas chromatography (GC) and gas chromatography-mass spectrometry (GC-MS). Acetylcholinesterase (AChE) and butyrylcholinesterase (BChE) inhibitory properties were investigated by employing Ellman’s method. Four in vitro assays, namely, 2,2-diphenyl-1-picrylhydrazyl (DPPH), 2,2′-azino-bis(3-ethylbenzothiazoline-6-sulfonic acid) (ABTS), ferric-reducing ability power (FRAP), and β-carotene bleaching tests, were used to study the antioxidant effects. Camphor (16.16–18.92%), 1,8-cineole (8.80–9.86%), β-pinene (3.08–9.14%), camphene (6.27–8.08%), and α-thujone (1.17–9.26%) are identified as the most abundant constituents. However, the content of these constituents varied depending on environmental factors and pedoclimatic conditions. Principal component analysis (PCA) was performed. Based on Relative Antioxidant Capacity Index (RACI), S2 essential oil exhibited the highest radical potential with an IC50 value of 20.64 μg/mL in ABTS test and presented the highest protection of lipid peroxidation with IC50 values of 38.06 and 46.32 μg/mL after 30 and 60 min of incubation, respectively. The most promising inhibitory activity against BChE was found for S3 sample (IC50 of 33.13 μg/mL).  相似文献   

13.
Basalt fibers were functionalized with gold nanoparticles and characterized by scanning electron microscopy and energy‐dispersive X‐ray spectroscopy. An in‐tube solid‐phase microextraction device was developed by packing the functionalized basalt fibers in a polyether ether ketone tube. The device was connected into high performance liquid chromatography equipment with a diode array detector to build online enrichment and analysis system. Eight polycyclic aromatic hydrocarbons were used as model analytes, important factors including sampling rate, sampling volume, organic solvent content in sample, and desorption time were investigated. Linear range (0.01–20 μg/L), detection limits (0.003–0.015 μg/L), and enrichment factors (130–1628) were given by the online analysis method. Relative standard deviations (= 5) of extraction repeatability on one tube and tube‐to‐tube repeatability were less than 5.2 and 14.7%, respectively. The analysis method was applied to detect polycyclic aromatic hydrocarbons in environmental water samples, and relative recoveries ranged from 87 to 128%.  相似文献   

14.
Herein, a method based on selective piazselenol formation is applied for total selenium determination in biofortified Allium species. Piazselenol is formed by reacting Se(IV) with an aromatic diamine, namely 4-nitro-1,2-phenylenediamine, in acidic medium. Samples were digested in a nitric acid/hydrogen peroxide open system, followed by selenate reduction in hydrochloric acid. Reaction conditions were optimized in terms of pH, temperature, reaction time, and other auxiliary reagents for interference removal, namely, EDTA and hydroxylamine. For the extraction of the selectively formed 4-nitro-piazselenol, micro-solid-phase extraction (μSPE) was applied, and the analysis and detection of the corresponding complex was performed by HPLC coupled with DAD. An external standard calibration curve was developed (R2 = 0.9994) with good sensitivity, and was used to calculate the total selenium content from several Allium plants material, with good intermediate precision (RSD% < 16%). The accuracy of the method was evaluated using both, a comparison with an accepted reference method from our previously published data, as well as three certified reference material with recoveries between 84–126%. The limit of detection was determined to be 0.35 μg/g (in solids) and 1.1 μg/L (in solution), while the limit of quantification was 1.07 μg/g and 3.4 μg/L (in solution). Using the proposed method, selenium content can be quickly and accurately determined in several types of samples. In addition, this study present experimental conditions for overcoming the interferences that might be encountered in selenium determination using piazselenol.  相似文献   

15.
Polydopamine was coated onto cotton fibers as the adsorbent to improve the extraction efficiency. Polydopamine‐coated cotton fibers were placed into a polyetheretherketone tube for in‐tube solid‐phase microextraction. To develop an online analysis system, the extraction tube was connected with high‐performance liquid chromatography. The tube was evaluated with five estrogenic analytes, and the extraction and desorption conditions were optimized to get high extraction efficiency. Under the optimum conditions, the enrichment factors of five analytes were 143–1745. An online analysis method was established, it had large linear ranges (0.10–40 and 0.16–40 μg/L), low limits of detection (0.03, 0.05 μg/L) and satisfactory repeatability (≤3.2%). The analysis method was applied to detect targets in the real samples like as hot water in new plastic cup and tap water. The relative recoveries spiked at 1 and 5 μg/L in these samples were investigated and the results were in the range of 83.7–109%.  相似文献   

16.
In this study, ultrasonic-assisted cellulase extraction (UCE) was applied to extract flavonoids and polyphenols from the Nymphaea hybrid flower. The extraction conditions were optimized using the response surface method (RSM) coupled with a Box-Behnken design. The crude extract of Nymphaea hybrid (NHE) was further purified using AB-8 macroporous resins, and the purified extract (NHEP) was characterized by FTIR and HPLC. In vitro activity determination by chemical method showed that NHEP displayed strong free radical scavenging abilities against the DPPH and ABTS radicals, good reduction power, and hyaluronidase inhibition. The cell viability by CCK-8 assays showed that NHEP had no significant cytotoxicity for B16 and HaCaT cells when the concentration was below 100 μg/mL and 120 μg/mL, respectively. NHEP with a concentration of 20–160 μg/mL can more effectively reduce the ROS level in H2O2 damaged HaCaT cells compared with 10 μg/mL of VC. The 40 μg/mL of NHEP had similar activity against intracellular melanin production in the B16 melanoma cells compared with 20 μg/mL Kojic acid. Good activities of antioxidation, whitening and protective effect against H2O2-induced oxidative damage promote the potential for NHEP as a functional raw material in the field of cosmetics and medicine.  相似文献   

17.
The parents’ addictions and eating habits have a significant influence on the child’s growth. The first stool of a newborn baby provides a large amount of information about xenobiotics transmitted by the mother’s body. The analytical technique used in the study is ion chromatography with pulsed amperometric detection (IC-PAD). The biological samples, which were obtained from women staying in a maternity ward and their partners, revealed cyanide concentrations in urine samples spanning 1.30–25.3 μg L−1. Meanwhile, the results of the meconium samples were in the range of 1.54 μg L−1 to 24.9 μg L−1. Under the optimized chromatographic conditions, the IC-PAD system exhibited satisfactory repeatability (R < 3%, n = 3) and good linearity in the range of 1–100 μg L−1. Thus, it proved to be an effective tool for monitoring trace cyanide concentration in a series of human body fluid matrices, including meconium. Based on the literature review, this is the first application of the IC-PAD analytical technique for the determination of cyanide ions in meconium samples.  相似文献   

18.
Triazine‐based organic polymers@SiO2 nanospheres were prepared and applied as an extraction coating onto stainless steel wires and the wires were filled into polyetheretherketone tube for in‐tube solid‐phase microextraction. Taking polycyclic aromatic hydrocarbons as targets, main factors affecting extraction performance of the tube were investigated through coupling to high performance liquid chromatography. Under the optimum conditions, an online analytical method for polycyclic aromatic hydrocarbons was established with large linear ranges (0.010‐20 µg/L), low limits of detection (0.003‐0.010 µg/L), high enrichment factors (533‐2954), and good repeatability (relative standard deviations <1.7% for intraday test, <5.0% for interday test). The analysis method was successfully applied to the detection of trace targets in real water samples and the relative recoveries ranged from 82.9 to 119.9%, which demonstrated the applicability of extraction tube in sample preparation.  相似文献   

19.
The four polycyclic aromatic hydrocarbon markers (PAH4) of benzo[a]anthracene (BaA), chrysene (Chr), benzo[b]fluoranthene (BbF), and benzo[a]pyrene (BaP) are indicators showing polycyclic aromatic hydrocarbon (PAH) contamination levels in Chinese medicine raw materials (CMRMs), extracts and health food products; Samples of herbal medicine, herbal extracts, and food supplements were extracted with n-hexane, then cleaned up sequentially on Florisil and EUPAH solid-phase extraction (SPE) columns. A gas chromatography–mass spectrometry method for the determination of four polycyclic aromatic hydrocarbon markers in Chinese medicine raw material, extracts, and health food products was established; In spiked-recovery experiments, the average recovery was about 78.6–107.6% with a precision of 2.3–10.5%. The limit of quantification (LOQ) and limit of detection (LOD) of the PAH4 markers in this method were 2.0 μg/kg and 0.7 μg/kg, respectively. When the developed method was utilized to determine PAH4 contents in 12 locally available health food products, 3 samples contained over 10.0 μg/kg BaP, and 5 samples contained over 50.0 μg/kg PAH4. The European Union (EU) limits for BaP and PAH4 are 10 and 50.0 μg/kg, respectively; therefore, more attention must be drawn to the exposure risk of BaP and PAH4 in CMRMs, their extracts, and health food products. According to the risk assessment based on the Margin of Exposure (MOE) method, it is recognized that the products mentioned in this study pose a low risk.  相似文献   

20.
This work entailed the development, optimization, validation, and application of a novel analytical approach, using the bar adsorptive microextraction technique (BAμE), for the determination of the six most common tricyclic antidepressants (TCAs; amitriptyline, mianserin, trimipramine, imipramine, mirtazapine and dosulepin) in urine matrices. To achieve this goal, we employed, for the first time, new generation microextraction devices coated with convenient sorbent phases, polymers and novel activated carbons prepared from biomaterial waste, in combination with large-volume-injection gas chromatography-mass spectrometry operating in selected-ion monitoring mode (LVI-GC-MS(SIM)). Preliminary assays on sorbent coatings, showed that the polymeric phases present a much more effective performance, as the tested biosorbents exhibited low efficiency for application in microextraction techniques. By using BAμE coated with C18 polymer, under optimized experimental conditions, the detection limits achieved for the six TCAs ranged from 0.2 to 1.6 μg L−1 and, weighted linear regressions resulted in remarkable linearity (r2 > 0.9960) between 10.0 and 1000.0 μg L−1. The developed analytical methodology (BAμE(C18)/LVI-GC-MS(SIM)) provided suitable matrix effects (90.2–112.9%, RSD ≤ 13.9%), high recovery yields (92.3–111.5%, RSD ≤ 12.3%) and a remarkable overall process efficiency (ranging from 84.9% to 124.3%, RSD ≤ 13.9%). The developed and validated methodology was successfully applied for screening the six TCAs in real urine matrices. The proposed analytical methodology proved to be an eco-user-friendly approach to monitor trace levels of TCAs in complex urine matrices and an outstanding analytical alternative in comparison with other microextraction-based techniques.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号