首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Simó C  Rizzi A  Barbas C  Cifuentes A 《Electrophoresis》2005,26(7-8):1432-1441
In this work, the development of a new chiral capillary electrophoresis-mass spectrometry (CE-MS) method to separate D- and L-amino acids is shown. On-line coupling between CE and MS is established through an electrospray-coaxial sheath flow interface. Enantiomer separation is achieved by using a cheap, nonvolatile, chiral selector as beta-cyclodextrin in the background electrolyte (BGE) together with a physically coated capillary that is aimed to prevent contamination of the electrospray. The capillary coating is simple and easy to obtain as it only requires flushing of the capillary with a polymer aqueous solution for 3 min. Optimization of CE parameters (pH of BGE, type and concentration of chiral selector, and capillary inner diameter) and electrospray-MS parameters (nature and flow rate of the sheath liquid, nebulizer pressure) is carried out. Two different derivatization protocols of amino acids using dansyl chloride (DNS) and fluorescein isothiocyanate (FITC) are compared in terms of MS sensitivity and chiral resolution. Under optimum CE-MS conditions it is observed that the MS sensitivity obtained for FITC- and DNS-amino acids is similar (with limit of detection (LOD) in the microM range, corresponding to amounts injected in the fmol range) while chiral resolution is better for FITC-amino acids. The optimized method is demonstrated to provide the simultaneous analysis of 15 selected amino acids (i.e., FITC-D/L-Asp, -Glu, -Ser, -Asn, -Ala, -Pro, -Arg, and FITC-gamma-aminobutyric acid (GABA) in a single chiral CE-MS run, corresponding to the main amino acids that can be found in orange. Moreover, as a result of the high resolution achieved, it is possible to detect down to 2% of D-Asp in the presence of 98% of L-Asp. The good possibilities of chiral CE-MS in food analysis are corroborated through the detection of the main amino acids in a commercial orange juice (i.e., FITC-L-Asp, -Glu, -Ser, -Asn, -Pro, -Arg, and the nonchiral FITC-GABA) as well as the determination of the fraudulent addition of synthetic amino acids (containing D- and L-forms) to a fresh orange juice.  相似文献   

2.
A CE method utilizing triple quadrupole electrospray (ES) MS (MS/MS) detection was developed and validated for the simultaneous measurement of nucleoside 5'-triphosphate and 5'-monophosphate anabolites of the anti-HIV (human immunodeficiency virus) didanosine (ddAMP, ddATP) and stavudine (d4TMP, d4TTP), among a pool of 14 endogenous 5'-mono-, di-, and triphosphate nucleosides. These compounds were spiked and extracted from peripheral blood mononuclear cells (PBMCs) which are the sites of HIV replication and drug action. An acetic acid/ammonia buffer (pH 10, ionic strength of 40 mM) was selected as running electrolyte, and the separation was performed by the simultaneous application of a CE voltage of +30 kV and an overimposed pressure of 28 mbar (0.4 psi). The application of pressure assistance was needed to provide stable ES conditions for successful coupling. The coupling was carried out with a modified sheath-flow interface, with one uninterrupted capillary (80 cmx 50 microm id; 192 microm od) in a dimension that fits into the ESI needle to get a stable ion spray. Some CE-MS parameters such as overimposed pressure, sheath-liquid composition, sheath-liquid and sheath-gas flow rates, ES voltage, and the CE capillary position were optimized in order to obtain an optimal sensitivity. The use of perfluorinated alcohols and acids in the coaxial sheath-liquid make-up (2,2,2-trifluoroethanol + 0.2 mM tridecafluoroheptanoic acid) appeared to provide the best MS sensitivity and improve the stability of spray. The linearity of the CE-MS and CE-MS/MS methods was checked under these conditions. Validation parameters such as accuracy, intraday and interday precision, and LOQs were determined in CE-MS/MS mode. Finally, the quantitation of d4T-TP and ddA-TP was validated in this CE-MS/MS system.  相似文献   

3.
We describe a capillary electrophoresis-mass spectrometry (CE-MS) method for newborn screening of a representative amino acid metabolic disease, namely, phenylketonuria (PKU). Underivatized phenylalanine and tyrosine in a dried blood spot (DBS) were simultaneously determined by CE-MS equipped with an ionophore membrane-packed sheathless electrospray ionization interface, which was developed by our group. The method was optimized for rapid determination of the underivatized amino acids, phenylalanine and tyrosine extracted from a DBS. Under the optimized conditions, the limit of detection of phenylalanine and tyrosine (signal-to-noise ratio, 3) was 0.03 and 0.07 mg/L in DBS, respectively, with a CE run time of less than 3 min. For repeated runs of a sample, coefficients of variation (CVs) for migration time were less than 3.7 %, whereas CVs for the area ratio under the curve were 2.1 and 2.9 % for 20 consecutive runs of 49.5 mg/kg Phe and 36.2 mg/kg Tyr, respectively. However, the relative standard deviations of intra- and interday assays for DBS samples were <6.2 and <5.8 %, respectively, which were substantially due to sample extraction from DBS. The analytical method was applied to real clinical samples of Korean neonates, and results were compared with those of conventional methods for PKU diagnosis, which required reference analytical methods such as isotope dilution CE-MS or high-performance liquid chromatography-mass spectrometry for quality assurance of the conventional kit-based assays. The distinct advantages of high sensitivity and extremely low sample volume, as well as a simple, easy, and economic sample pretreatment, were demonstrated for the proposed method.  相似文献   

4.
Hau J  Devaud S  Blank I 《Electrophoresis》2004,25(13):2077-2083
Capillary electrophoresis coupled to mass spectrometry (CE-MS) is reported for the first time as an alternative and powerful analytical method for the characterization and monitoring of N-substituted 1-amino-1-deoxyketoses (Amadori compounds). It allows rapid separation and identification of Amadori compounds, while benefiting from the well-known advantages of MS, such as specificity and sensitivity. Amadori compounds of several amino acids, such as glycine, valine, isoleucine, methionine, proline, and phenylalanine, as well as a cysteine-derived compound, were separated and/or discriminated using CE-MS/MS under standard conditions. The technique may also be useful to study the stability and degradation kinetics of other labile charged Maillard intermediates that play an important role in food and medical science.  相似文献   

5.
This paper shows the potentiality of capillary electrophoresis (CE) coupled to mass spectrometry (MS) for the analysis of heterocyclic aromatic amines obtaining good results in terms of sensitivity and precision. These compounds have a special interest since they can be carcinogenic for humans. The optimization of a CE-MS method was performed and the best conditions were obtained using a 16 mM formic acid/ammonium formate solution at pH 4.5 with 60% methanol as running electrolyte. For CE-MS coupling, a sheath liquid methanol/20 mM formic acid (75/25) solution at a flow rate of 3 microL/min and hydrodynamic injection of methanol mixtures for 10 s were used. Detection limits ranging from 18 ng/g to 360 ng/g and precisions up to 1.4% and 12% for migration time and concentration, respectively, were obtained. In order to improve sensitivity, field-amplified sample injection was applied as an in-line preconcentration method. Methanol/5 mM formic acid (50/50) as a sample solvent, 3 s hydrodynamic injection (0.5 psi) of a methanol plug, and 25 s of electrokinetic injection (10 kV) of the sample were found to be the optimum conditions. Detection limits up to 25 times lower and similar precisions than those reported for hydrodynamic injection were obtained.  相似文献   

6.
The well known biospecific noncovalent receptor-ligand association complexes between the immunophilin FKBP and the immunosuppressive drugs FK506 and Rapamycin (RM) were investigated by on-line capillary electrophoresis-mass spectrometry (CE-MS) under selected ion monitoring (SIM) conditions and by CE-MS with tandem mass spectrometry (CE-MS/MS) under selected reaction monitoring (SRM) conditions. Solutions of hFKBP (33.3 µM) were dissolved in 50 mM ammonium acetate at pH 7.5. Samples that contained 100 µM of FK506 or RM also were prepared under the same solution conditions. By using these aqueous pH neutral conditions, samples were analyzed by SIM CE-MS and SRM CE-MS and the target complexes were separated by CE with mass spectrometer detection of the individual complexes between FKBP and FK506 [hFKBP + FK506 + 7HJ7+ as well as FKBP and RM [hFKBP + RM + 7HJ7+. In an experiment where a mixture of FK506 and RM was analyzed in the presence of FKBP, a nine-to-one ratio of ion current abundances between the RM and FK506 complexes was observed as reported in the literature from other studies. These results suggest that CE-MS and CE-MS/MS may be yet another analytical method for studying noncovalent interactions of biologically important macromolecules under physiological conditions.  相似文献   

7.
Juan-García A  Font G  Picó Y 《Electrophoresis》2005,26(7-8):1550-1561
A method to identify and quantify six pesticide residues - dinoseb, pirimicarb, procymidone, pyrifenox, pyrimethanil, and thiabendazole - in peaches and nectarines using capillary electrophoresis-electrospray ionization-quadrupole ion trap-tandem mass spectrometry (CE-ESI-MS/MS) is described. Separation was carried out using a buffer of 0.3 M ammonium acetate at pH 4 with 10% methanol. Pesticide residues present in peach and nectarine samples were preconcentrated by solid-phase extraction using C(18), eluted with CH(2)Cl(2), concentrated to dryness, and redissolved in buffer to obtain lower detection limits. The recoveries of the analytes ranged from 58 to 99% and the relative standard deviations were 9 to 19%. Under optimized CE-MS/MS conditions the minimum detectable levels for the six pesticides in spiked peach samples were between 0.01 mg/kg for pirimicarb and 0.05 mg/kg for procymidone with pressure injection of 50 mbar for 5 s (5 nL) at a signal-to-noise ratio of 3, which constitutes a severalfold increase in sensitivity compared to CE-MS, using a single quadrupole, and to conventional CE-UV. The potential of the method was demonstrated by analyzing different samples taken from regional agricultural cooperatives. The pesticides most often detected were thiabendazole and procymidone.  相似文献   

8.
Online coupling of capillary electrophoresis (CE) to electrospray ionization mass spectrometry (MS) has shown considerable potential, however, technical challenges have limited its use. In this study, we have developed a simple and sensitive sheathless CE-MS interface based on the novel concept of forming a sub-micrometer fracture directly in the capillary. The simple interface design allowed the generation of a stable ESI spray capable of ionization at low nanoliter flow-rates (45–90 nL/min) for high sensitivity MS analysis of challenging samples like those containing proteins and peptides. By analysis of a model peptide (leucine enkephalin), a limit of detection (LOD) of 0.045 pmol/μL (corresponding to 67 attomol in a sample volume of ∼15 nL) was obtained. The merit of the CE-MS approach was demonstrated by analysis of bovine serum albumin (BSA) tryptic peptides. A well-resolved separation profile was achieved and comparable sequence coverage was obtained by the CE-MS method (73%) compared to a representative UPLC-MS method (77%). The CE-MS interface was subsequently used to analyse a more complex sample of pharmaceutically relevant human proteins including insulin, tissue factor and α-synuclein. Efficient separation and protein ESI mass spectra of adequate quality could be achieved using only a small amount of sample (30 fmol). In addition, analysis of ubiquitin samples under both native and denatured conditions, indicate that the CE-MS setup can facilitate native MS applications to probe the conformational properties of proteins. Thus, the described CE-MS setup should be useful for a wide range of high-sensitivity applications in protein research.  相似文献   

9.
A new, simple and rapid capillary electrophoresis-mass spectrometry (CE-MS) method, using a cationic polymer-coated capillary to reverse electroosmotic flow, is proposed and validated for the separation and simultaneous quantification of 11 gibberellins (GAs). Under optimum conditions, a baseline separation of 11 GAs, including GA1, GA3, GA4, GA5, GA6, GA7, GA13, GA19, GA20, GA24 and GA53 was accomplished within 25 min using 70 mM ammonium formate/formic acid buffer (pH 3.8) and 2% (v/v) acetonitrile with -25 kV as the separation voltage. Satisfactory results were obtained in terms of linearity (R2 between 0.984 and 0.995), precision (RSD of migration time below 0.8%) and sensitivity (LOD between 0.31 and 1.02 microM). Furthermore, a novel solid-phase extraction (SPE) procedure was developed for the pre-concentration and purification of GAs using Oasis MAX cartridges. The combination of SPE and CE-MS approach was applied to screen for endogenous GAs present in coconut (Cocos nucifera L.) water sample. To illustrate the applicability of the method, GA1 and GA3 were successfully detected and quantified in coconut water. Finally, the GA1 and GA3 identities were further unequivocally confirmed by CE-tandem MS experiments operating in the multiple reaction monitoring mode.  相似文献   

10.
The sensitivity of coupled enantioselective capillary electrophoresis-mass spectrometry (CE-MS) of amino acids (AAs) is often hampered by the chiral selectors in the background electrolyte (BGE). A new method is presented in which the use of a chiral selector is circumvented by employing (+)-1-(9-fluorenyl)ethyl chloroformate (FLEC) as chiral AA derivatizing agent and ammonium perfluorooctanoate (APFO) as a volatile pseudostationary phase for separation of the formed diastereomers. Efficient AA derivatization with FLEC was completed within 10 min. Infusion experiments showed that the APFO concentration hardly affects the MS response of FLEC-AAs and presents significantly less ion suppression than equal concentrations of ammonium acetate. The effect of the pH and APFO concentration of the BGE and the capillary temperature were studied in order to achieve optimized enantioseparation. Optimization of CE-MS parameters, such as sheath-liquid composition and flow rate, ESI and MS settings was performed in order to prevent analyte fragmentation and achieve sensitive detection. Selective detection and quantification of 14 chiral proteinogenic AAs was achieved with chiral resolution between 1.2 and 8.6, and limits of detection ranging from 130 to 630 nM injected concentration. Aspartic acid and glutamic acid were detected, but not enantioseparated. The optimized method was applied to the analysis of chiral AAs in cerebrospinal fluid (CSF). Good linearity (R2 > 0.99) and acceptable peak area and electrophoretic mobility repeatability (RSDs below 21% and 2.4%, respectively) were achieved for the chiral proteinogenic AAs, with sensitivity and chiral resolution mostly similar to obtained for standard solutions. Next to l-AAs, endogenous levels of d-serine and d-glutamine could be measured in CSF revealing enantiomeric ratios of 4.8%–8.0% and 0.34%–0.74%, respectively, and indicating the method's potential for the analysis of low concentrations of d-AAs in presence of abundant l-AAs.  相似文献   

11.
The capillary electrophoretic-mass spectrometric analysis (CE-MS) of catecholamines was optimized with coaxial sheath flow interface and electrospray ionization (ESI). The parameters studied included the sheath liquid composition and its flow rate, separation conditions in ammonium acetate buffer together with the ESI and cone voltages as mass spectrometric parameters. In addition, the effect of ESI voltage on injection as well as the siphoning effect were considered. The optimized conditions were a sheath liquid composition of methanol-water (80:20 v/v) with 0.5% acetic acid, with a flow rate of 6 microL/min. The capillary electrophoretic separation parameters were optimized with 50 mM ammonium acetate buffer, pH 4.0, to +25 kV separation voltage together with a pressure of 0.1 psi. The most intensive signals were obtained with an ESI voltage of +4.0 kV and a cone voltage of +20 V. The nonactive ESI voltage during injection as well as avoidance of the siphoning effect increased the sensitivity of the MS detection considerably. The use of ammonium hydroxide as the CE capillary conditioning solution instead of sodium hydroxide did not affect the CE-MS performance, but allowed the conditioning of the capillary between analyses to be performed in the MS without contaminating the ion source.  相似文献   

12.
A new analytical methodology based on capillary electrophoresis-mass spectrometry (CE-MS(2)) is presented in this work, enabling the identification and determination of six non-protein amino acids (ornithine, β-alanine, GABA, alloisoleucine, citrulline and pyroglutamic acid) in vegetable oils. This methodology is based on a previous derivatization with butanol and subsequent separation using acidic conditions followed by on-line coupling to an ion trap analyzer for MS(2) detection established through an electrospray-coaxial sheath flow interface. The electrophoretic and interface parameters were optimized obtaining the separation of all compounds in less than 15 min and with resolutions higher than 5. The proposed method was validated by assessing its accuracy, precision (RSD<7% for corrected peak areas), LODs and LOQs (between 0.04-0.19 ng/g and 0.06-0.31 ng/g, respectively) and linearity range (R(2)>0.99), and it was used in order to identify the selected non-protein amino acids in soybean oils, sunflower oils, corn oils and extra virgin olive oils. MS(2) experiments performed the fingerprint fragmentation of these compounds allowing to corroborate ornithine and alloisoleucine in seed oils but not in olive oils. The method was applied to identify and quantify olive oil adulterations with soybean oil detecting in a single run the amino acids in mixtures up to 2% (w/w). The results showed a high potential in using these compounds as novel markers for the detection of adulterations of extra virgin olive oils with seed oils. Thus, the developed method could be considered a simple, rapid and reliable method for the quality evaluation of extra virgin olive oil permitting its authentication.  相似文献   

13.
A CE-MS method for metabolic profiling of amino acids was developed and used in an integrated functional genomics project to study the response of Medicago truncatula liquid suspension cell cultures to stress. This project required the analysis of more than 500 root cell culture extracts. The CE-MS method profiled 20 biologically important amino acids. The CE-MS method required no sample derivatization prior to injection and used minimal sample preparation. The method is described in terms of CE and MS operational parameters, reproducibility of migration times and response ratios, sample preparation, sample throughput, and reliability. This method was then compared with a previously published report that used GC-MS metabolic profiling for the same tissues. The data reveal a high level of similarity between the CE-MS and GC-MS amino acid profiling methods, thus supporting these as complementary technologies for metabolomics. We conclude that CE-MS is a valid alternative to GC-MS for targeted profiling of metabolites, such as amino acids, and possesses some significant advantages over GC-MS.  相似文献   

14.
Li C  Chen Z  Wen D  Zhang J  Cong W  Yu B  Liao Y  Liu H 《Electrophoresis》2006,27(11):2152-2163
In this paper, we propose a new strategy for separation and determination of tobacco-specific N-nitrosamines (TSNAs), a group of strong carcinogens found only in tobacco products, by using CZE and CE-MS associated with SPE. Six TSNAs: N'-nitrosonornicotine, N'-nitrosoanatabine, N'-nitrosoanabasine, 4-(methylnitrosamino)-1-(3-pyridyl)-1-butanone, 4-(methylnitrosamino)-1-(3-pyridyl)-1-butanol, and 4-(methylnitrosamino)-4-(3-pyridyl)-1-butanol were simultaneously separated by either of two CZE methods, one of which worked with ammonium formate buffer (pH 2.5) and another with citrate buffer (pH 2.4), as well as a CE-MS method. The CZE conditions including pH and concentration of running buffer, capillary length, applied voltage, and capillary temperature were systematically optimized. For CE-MS method, an optimized sheath liquid consisted of methanol-water was used at a flow rate of 10 muL/min. With SPE procedure, our proposed CE-MS method was successfully applied to determine TSNAs after 15 min metabolism in rabbits. A comparison study between CZE and CE-MS methods for quantitative purposes was carried out, showing that both methods provided similar separation efficiency, selectivity, repeatability, linearity, and recovery. However, CE-MS method was better suited for the analysis of TSNAs in complicated biological samples for its sensitivity and extra information on molecular structure. Having good accordance with our previous work by using LC-MS, the new CE-MS method is expected to be an alternative to the LC-MS method and applied to study the metabolism of TSNAs.  相似文献   

15.
Jeong JS  Kim SK  Park SR 《Electrophoresis》2012,33(14):2112-2121
A high durability sheathless electrospray ionization interface of CE-MS is applied for the sensitive analysis of underivatized amino acids. The sheathless interface was realized using an ionophore membrane-packed electro-conduction channel. The interface functioned well with a volatile alkaline background electrolyte (BGE) and uncoated fused-silica capillaries for CE-MS analysis of underivatized amino acids. High electroosmotic flow with alkaline BGE facilitated high separation efficiency (>100,000 theoretical plates) and short analysis time (<15 min). Both the short-term stability and long-term durability are particularly suited for routine applications. Using electrokinetic injection and the multiple reaction monitoring (MRM) mode with a triple-quadrupole analyzer, high sensitivity was achieved, which yielded detection limits of 0.05-0.81 μM. For the quantitation of underivatized amino acids, quantification precisions (RSDs) for intra- and inter-day analyses were less than 3%. Recoveries from serum were 96.3-101.8% for isotope dilution mass spectrometry (IDMS). When compared with HPLC-IDMS for human serum samples, highly agreeable (96.9-102.0%) results were obtained with the proposed CE-IDMS method.  相似文献   

16.
A generic approach has been developed for coupling capillary electrophoresis (CE) using non-volatile background electrolytes (BGEs) with mass spectrometry (MS) using a sheath liquid interface. CE-MS has been applied for basic and bi-functional compounds using a BGE consisting of 100 mM of TRIS adjusted to pH 2.5 using phosphoric acid. A liquid sheath effect is observed which may influence the CZE separation and hence may complicate the correlation between CE-UV and CE-MS methods. The influence of the liquid sheath effect on the migration behavior of basic pharmaceuticals has been studied by simulation experiments, in which the BGE outlet vial is replaced by sheath liquid in a CE-UV experiment. As a consequence of the liquid sheath effect, phosphate based BGEs can be used without significant loss of MS sensitivity compared to volatile BGEs. The use of buffer constituents such as TRIS can lead to lower detection limits as loss of MS sensitivity can be compensated by better CE performance. TRIS based BGEs permit relatively high injection amounts of about 100 pmol while maintaining high resolution. The ESI-MS parameters were optimized for a generic method with maximum sensitivity and stable operation, in which the composition of the sheath liquid and the position of the capillary were found to be important. Furthermore, the nebulizing pressure strongly influenced the separation efficiency. The system showed stable performance for several days and a reproducibility of about 15% RSD in peak area has been obtained. Nearly all test compounds used in this study could be analyzed with an MS detection limit of 0.05% measured in scan mode using extracted ion chromatograms. As a result, CE-MS was found to be a valuable analytical tool for pharmaceutical impurity profiling.  相似文献   

17.
Concentration sensitivity is a key performance indicator for analytical techniques including for capillary electrophoresis-mass spectrometry (CE–MS) with electrospray ionization (ESI). In this study, a flow-through microvial interface was used to couple CE with MS and improve the ESI stability and detection sensitivity. By infusing a peptide mixture through the interface into an MS detector at a typical flow rate for CE-MS analysis, the spatial region near the interface was mapped for MS signal intensity. When the sprayer tip was within a 6 × 6.5 × 5 mm region in front of the MS inlet, the ESI was stable with no significant loss of signal intensity for ions with m/z 239. Finite element simulations showed that the average electric field strength at the emitter tip did not change significantly with minor changes in emitter tip location. Experiments were conducted with four different mass spectrometer platforms coupled to CE via the flow-through microvial interface. Key performance indicators, that is, limit of detection (LOD) and linearity of calibration curves were measured for nine amino acids and five peptides. Inter- and intraday reproducibility were also tested. The results were shown to be suitable for quantification when internal standards were used.  相似文献   

18.
A simple, rapid and efficient capillary electrophoresis-mass spectrometry (CE-MS) method was developed to analyze urinary nucleosides for the first time. The composition of CE buffer and MS parameters were systematically optimized. The optimum buffer was 150 mM acetic acid containing 15% methanol and 15% ethanol. The optimum MS parameters were: methanol containing 0.5% acetic acid was selected as the sheath liquid and the flow rate was 5 microL/min; the flow rate and temperature of drying gas were 6L/min and 150 degrees C, respectively; the pressure of nebulizing gas was 2 psig; and the fragmentor and ESI voltage were 100 V and 4000 V, respectively. Under the optimum CE-MS conditions, the urinary nucleosides were separated within 18 min. The linearity between the relative peak areas and the corresponding concentration of nine nucleosides markers were excellent. The limits of detection (S/N=3) of markers were 0.00862-3.82 nmol/mL. The optimum CE-MS method was applied to analyze urine from 20 bladder cancer patients and 20 healthy volunteers. Considering the standards of many nucleosides cannot be obtained, it is not the ratios of the concentrations of nucleosides to that of creatinine in the literatures, but the ratios of the relative peak area of nucleosides to the concentration of creatinine that used for pattern recognition. And, the statistical analysis result indicated this method was feasible.  相似文献   

19.
A new methodology is proposed to automate the monitoring of sulfonamide residues in milk samples. It combines a screening unit for the total amount of sulfonamide with capillary electrophoresis-mass spectrometry (CE-MS) equipment for processing the samples containing a detectable level of sulfonamide. The screening unit consists of continuous-flow system (CFS) to precipitate the proteins connected on-line to the CE-MS equipment, in which a common characteristic ion of all sulfonamides was monitored with the MS detector by flushing the sample through the capillary. The confirmatory method is based on the purification and preconcentration of sulfonamides in a CFS unit and posterior analysis by CE-MS. The sample treatment unit was also on-line connected to the CE-MS equipment. In order to increase sensitivity, the flow rate of the sheath liquid was diminished from 0.5 to 0.2 microL.min(-1) by increasing the content in water from 0 to 50% and the formic acid from 0.5 to 1.5% in this liquid and by applying an overimposed pressure of 5 mbar during the electrophoretic separation. The method allowed the analysis of 30 samples per hour.  相似文献   

20.
Over the last two decades, coupled capillary electrophoresis (CE)–mass spectrometry (MS) has developed into a generally accepted technique with a wide applicability. A growing number of CE-MS applications make use of capillaries where the internal wall is modified with surface coating agents. In CE-MS, capillary coatings are used to prevent analyte adsorption and to provide appropriate conditions for CE-MS interfacing. This paper gives an overview of the various capillary coating strategies used in CE-MS. The main attention is devoted to the way coatings can contribute to a proper CE-MS operation. The foremost capillary coating methods are discussed with emphasis on their compatibility with MS detection. The role of capillary coatings in the control of the electroosmotic flow and the consequences for CE-MS coupling are treated. Subsequently, an overview of reported applications of CE-MS employing different coating principles is presented. Selected examples are given to illustrate the usefulness of the coatings and the overall applicability of the CE-MS systems. It is concluded that capillary coatings can enhance the performance and stability of CE-MS systems, yielding a highly valuable and reproducible analytical tool.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号