首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 656 毫秒
1.
A method for the determination of aldrin, dieldrin, DDT, DDE, and DDD contamination in animal fats (beef tallow, lard, and chicken fat) without using toxic reagents is developed, that uses high-performance liquid chromatography after the sample has been prepared by matrix solid-phase dispersion (MSPD) with acidic alumina oxide. A reversed-phase C1-silica column with a mobile phase of 50% (v/v) ethanol solution (in water) and a photo-diode array detector were used for the determination. Average recoveries of the target compounds (0.2–5.0 g g–1) ranged from 84–98%, with coefficients of variation of <5%. The limits of quantitation were 0.16 g g–1 for AD, 0.10 g g–1 for DD, 0.06 g g–1 for DDT, 0.07 g g–1 for DDE, and 0.05 g g–1 for DDD. No toxic reagents were used at all.  相似文献   

2.
Summary The reducing fusion gas extraction method has been used for the determination of nitrogen in uranium metal and uranium dioxide reference materials at levels of about 10–15g·g–1. It has been found that when extracting at temperatures above 2700° C the use of a platinum flux is no longer necessary. Pure nitrogen and nitrogen-helium mixtures were used for calibrating the detection unit in the range of 1.5–670 g. The calibration of the extraction was performed with metallic reference materials in the range of 8–331 g N2 content.
Bestimmung von Stickstoff in Uran und Uranoxid durch Hochtemperatur-Gasextraktion
Zusammenfassung Die Gasextraktion aus reduzierender Schmelze wurde zur Stickstoffbestimmung in Uranmetall- und Urandioxid-Referenzmaterialien bei Gehalten von 10–15 g·g–1 angewendet. Bei Temperaturen über 2700° C ist kein Platinbad mehr erforderlich. Zur Eichung der Detektionseinheit im Bereich von 1,5–670 g wurden reiner Stickstoff oder Stickstoff-Helium-Mischungen benutzt. Zur Eichung der Extraktion wurden metallische Referenzmaterialien mit (8–331g) N2 eingesetzt.
  相似文献   

3.
A sensitive spectrophotometric method has been developed for the determination of microamounts of thorium using 0.05% thorin in a 3M perchloric acid solution as a chromogenic reagent and measuring the absorbance at 544 nm. The complex of thorium thus formed, is stable for more than two months with a constant absorbance of ±0.55%. Beer's law is obeyed from 0 to 25 g g–1 of thorium in a solution with a molar absorptivity (544 nm) = 1.69×104 M–1 cm–1 at 26±1 °C. Among the anions tested, only phosphate, acetate and cyanide at >200-fold excess of thorium interfere in the determination, whereas cations like Zn(II), Al(III), Na(I), Mg(II), and Ca(II) do not effect the absorbance. Thorium can be determined in the presence of oxalate, nitrate, tartrate, sulfate, thiosulfate, citrate, and ascorbate. The accuracy of the method has been checked by measuring the known concentration of thorium in the range of 100 g-5 mg g–1 and found to be in the range of 7.7–0.9%. The method has been applied successfully to determine thorium at g g–1 level in local ore samples with a precision of ±0.3%. The sensitivity of the method on Sandell's scale is 0.082±0.002 g g–1 cm–1.  相似文献   

4.
Inductively coupled plasma-mass spectrometry (ICP-MS) was used to determine the concentration of platinum (Pt) in silicone breast implant gel (range, 0.26–48.90 g g–1 Pt; n=15), elastomer (range, 3.05–28.78 g g–1 Pt; n=7), double lumen (range, 5.79–125.27 g g–1 Pt; n=7), foam (range, 5.79–8.36 g g–1 Pt; n=2), and capsular tissue (range, 0.003–0.272 g g–1 Pt; n=15). The results show that very high levels of Pt are present in the encasing elastomer, double lumen, and foam envelope materials. Silicone breast implants can be a source of significant Pt exposure for individuals with these implants.  相似文献   

5.
The formation of nucleic acids/8-hydroxyquinoline/yttrium(III) ternary complexes and their fluorescent properties have been studied. The nucleic acids studied include native and thermally denatured calf thymus DNA, fish sperm DNA and yeast RNA. In the range of pH 7.6–8.5, controlled by NH3-NH4C1 buffer, ternary complexes are formed that fluoresce at different wavelengths with different nucleic acids. Based on the fluorescence reactions, sensitive spectrofluorimetric methods for nucleic acids are proposed. In optimal conditions, the calibration curves were linear in the range 0.5–4.0 gml–1 for calf thymus DNA, 0.5–2.5 g ml–1 for fish sperm DNA and 0.5–4.0 g ml–1 for yeast RNA. The limits of determination (3 ) were 0.030 g ml–1 for calf thymus DNA, 0.020 g ml–1 for fish sperm DNA and 0.090 g ml–1 for yeast RNA. Corresponding to the interferences of coexisting substances, six synthetic samples were constructed and the results of determination were satisfactory.  相似文献   

6.
Nanometer-sized l-cysteine-capped ZnS particles have been synthesized and used as a fluorescence probe to investigate the effect of proteins on fluorescent intensity. With =190 nm, maximum and constant synchronous fluorescence enhancement was produced at 267 nm and pH 5.12 in the presence of proteins. A highly sensitive synchronous fluorescence method for the rapid determination of proteins has been developed. Under optimum conditions, calibration graphs are linear over the range 0.03–8.0 g mL–1 for bovine serum albumin (BSA), 0.01–6.0 g mL–1 for human serum albumin (HSA), 0.05–8.0 g mL–1 for -globulin (-G), and 0.04–4.0 g mL–1 for ovalbumin, respectively. The relative standard deviations of seven replicate measurements were 1.75% for 1.0 g mL–1 BSA, 1.90% for 1.0 g mL–1 HSA, 1.65% for 1.0 g mL–1 -G, and 2.32% for 1.0 g mL–1 ovalbumin.  相似文献   

7.
ET-AAS is investigated for the analysis of high purity mercury. Two possibilities are proposed: ET-AAS determination of trace analytes in the presence of high mercury concentrations or after matrix separation by reduction. The ET-AAS analysis of high-purity mercury under optimal instrumental parameters permits fast and reproducible determination of 0.03 gg–1 Al, Cd and Mn; 0.05 gg–1 Cu, Co, Cr, Fe, Ni and Pb and 0.2 gg–1 V. Preliminary mercury matrix reductive separation with ascorbic acid allows determination of 0.005 gg–1 Cd, 0.02 gg–1 Cu, Cr and Mn, 0.03 g g–1 Co, Ni and Pb, 0.05 g g–1 Al and Fe and 0.1 gg–1 V, but the reproducibility is lower. The main advantage of the second procedure is that it avoids laboratory and instrument pollution with toxic mercury.  相似文献   

8.
Column preconcentration methods have been established for the spectrophotometric determination of trace nitrite with sulfanilic acid (SA) orp-aminoacetophenone (AAP) as the diazotizable aromatic amine andN, N-dimethylaniline (DMA) or 1-aminonaphthalene (AN) as the coupling agent, using differention-pairs co-precipitated with biphenyl. Nitrite ion reacts with SA in the pH range 2.0–3.0 and AAP in the pH range 1.7–3.0 in HCl medium to form water-soluble colourless diazonium cations. These cations are subsequently coupled with DMA in the pH range 3.7–6.1 for the SA-DMA system and AN in the pH range 1.7–2.3 for the AAP-AN system to be retained on microcrystalline biphenyl packed in a column. The solid mass is dissolved out from the column with 5 ml of DMF and the absorbance is measured by a spectrophotometer at 420 nm for the SA-DMA system and at 517 nm for the AAP-AN system. The calibration was linear over the concentration ranges 0.3–6.0 g of nitrite in 5 ml of DMF solution (i.e., 0.02–0.40 g/ml in the sample solution) for the SA-DMA system and 0.5–7.0 g of nitrite in 5 ml of DMF solution (i.e., 0.03–0.47 g/ml in the sample solution) for the AAP-AN system. The molar absorptivity and Sandell's sensitivity were respectively 2.63 × 104lmol–1cm–1 and 1.75 × 10–3 g cm–2 for SA-DMA and 3.28 × 104lmol–1 cm–1 and 1.40 × 10–3 g cm–2 for AAP-AN. The concentration factors were 4 and 16 for SA-DMA and AAP-AN, respectively. The detection limits were 0.0138 and 0.0175 g/ml NO2 for SA-DMA and AAP-AN, respectively. Seven replicate determinations of a solution containing 3.5 g of nitrite gave mean absorbances of 0.410 and 0.500 with relative standard deviations of 0.51 and 0.55% for SA-DMA and AAP-AN, respectively. Interference from various foreign ions has been studied and the methods have been applied to the determination of nitrite in environmental samples.  相似文献   

9.
A method using headspace solid-phase microextraction (HS-SPME) then gas chromatography–mass spectrometry with selected ion monitoring (GC–MS, SIM) has been developed for determination of trace amounts of the fungicides pyrimethanil and kresoxim-methyl in soil and humic materials. Both fungicides were extracted on to a fused-silica fibre coated with 85 m polyacrylate (PA). Response-surface methodology was used to optimise the experimental conditions. For soil samples the linear dynamic range of application was 0.004–1.000 g g–1 for pyrimethanil and 0.013–1.000 g g–1 for kresoxim-methyl. The detection limits were 0.001 g g–1 and 0.004 g g–1 for pyrimethanil and kresoxim-methyl, respectively. HP-SPME–GC–MS analysis was highly reproducible—relative standard deviations (RSD) were between 6.7 and 12.2%. The method was validated by analysis of spiked matrix samples and used to investigate the presence of pyrimethanil and kresoxim-methyl above the detection limits in soil and humic materials.  相似文献   

10.
Summary A method has been proposed for the determination of small quantities of Cl, SCN and I in mixtures. The method is based on the use of filter paper evenly impregnated with Ag2CrO4. The method permits the determination of 5 to 50g of Cl; 15 to 100g of I and 10 to 150g of SCN with an accuracy of 1.5%.The method may also be used for determination of SCN alone.
Zusammenfassung Ein Verfahren für die Bestimmung kleiner Mengen Chlorid, Rhodanid und Jodid in deren Gemischen wird vorgeschlagen. Es beruht auf der Verwendung eines mit Silberchromat gleichmäßig imprägnierten Filtrierpapierstreifens und ermöglicht die Bestimmung von 5 bis 50g Chlorid,15 bis 100g Jodid und 10 bis 150g Rhodanid mit einer Genauigkeit von 1,5%. Das Verfahren kann auch für die Bestimmung von Rhodanid allein verwendet werden.

Résumé On a proposé une méthode pour le dosage de petites quantités de Cl, SCN, et I en mélanges. La méthode est fondée sur l'emploi d'un papierfiltre uniformément imprégné d'Ag2CrO4. Elle permet le dosage de 5 à 50g de Cl, 15 à 100g d'I et de 10 à 150g de SON, à la précision de 1,5%. On peut aussi utiliser la méthode pour le dosage de SCN seul.
  相似文献   

11.
The aim of this work was to determine the concentrations of some essential and toxic elements in the muscle of ten species of commercial fish consumed in Portugal. We combined two different techniques for determination of the elements—energy-dispersive X-ray fluorescence (EDXRF) was used to quantify K, Ca, Fe, Zn, Se, Rb, and Sr and flame atomic-absorption spectrometry for analysis of Cr, Ni, Cu, Cd, Hg, and Pb. The latter technique was used because of its higher sensitivity, because these elements were not detected by EDXRF. The results obtained show a similar pattern for the trace elements. K and Ca are present at the highest concentrations in all the samples studied, from 0.6–1.3% and from 0.04–0.08%, respectively, followed by Zn, Fe, Sr, Se, and Rb. Sr is present at higher concentrations than Rb in all the species studied except meagre. Concentrations of the elements in octopus do not follow this pattern—Fe is present at a higher concentration than Zn. Low concentrations of Cr (0.66–1.5 g g–1), Ni (0.11–0.24 g g–1), Cd (0.01–0.08 g g–1), Hg (0.49–2.74 g g–1), and Pb (0.02–0.06 g g–1) were observed in all the samples analysed. The concentration of Hg was highest in Helicolenus dactylopterus—5.4 g g–1 in one sample.  相似文献   

12.
The determination of trace metals, e.g. Bi, Cd, Pb, in high-purity aluminium, zinc and commercial steel by flame or graphite furnace atomic absorption spectrometry following their preconcentrations as iodo complexes on XAD-1180 resin by means of a short column system is described. The recoveries are quantitative (95%). The relative standard deviations varies between 6% and 10%. The relative errors are less than 8% in a concentration range of 1 × 10–3 –4 × 10–5%. Detection limits for flame AAS and GFAAS were in the ranges of 0.002–0.110 g/ml and 0.0003–0.004 g/ml or in the ranges of 0.08–4.40 g/g and 0.012–0.16 g/g with respect to the solid samples, respectively.  相似文献   

13.
Summary A simultaneous capillary Gas Chromatographic-Mass Spectrometric (GC-MS) method is described for the determination of thirteen pesticides belonging to the triazine and amide families in water. The sample is extracted in liquid-liquid mode (dichloromethane) and then the determination of the residues is carried out by capillary gas chromatography with mass spectrometric detection in the Selected-Ion Monitoring mode (SIM). The average recoveries of spiked compounds are in the 78.4–135.4% range between the relative low level (0.100 g L–1) and the relative high level (10.0 g L–1). The limits of detection (LOD) are in the 0.009–0.128 g L–1 range.  相似文献   

14.
Various mushroom species have been analyzed for their elemental composition (i.e., Al, B, Ba, Ca, Cd, Cr, Cu, Fe, K, Mg, Mn, Na, P, Sr and Zn) by means of ICP-AES. The accuracy of the measurements was confirmed by analyzing a series of the same samples by short time activation analysis. The data were evaluated statistically including the values of137Cs. The results denote that the distribution of these elements and their correlation of these elements and their correlation coefficients are highly distinctive for each mushroom species. K, Na and P were found to correlate negatively with137Cs in most species. Suillus grevillei and Cantharellus cibarius show high Be values (0.27 and 0.30 g g–1, respectively), while Pb was high in Suillus grevillei (16.3 g g–1) and Amanita rubescens (9.3 g g–1). Higher levels of Cd were found in Rozites caperata and Russula vesca with a mean of 9.2 and 16.1 g g–1, respectively. Cluster analysis was applied to classify these samples according to their botanical species using their elemental composition. The concentrations of Al, Cr, Mn, Na and137Cs have no influence on the classification of these samples.  相似文献   

15.
Summary A precise, accurate procedure is proposed for the determination of arsenic in mussel products by inductively coupled plasma atomic emission spectrometry. Organic matter is destroyed by dry ashing. Experimental conditions for the determination of arsenic were selected and an interference study was carried out. The methodology developed has a detection limit of 0.1 g g–1, a relative standard deviation of 3%, and a recovery percentage of 98±2%. The accuracy of the method was checked by analysis of a certified sample of NIST oyster tissue (certified 14.0±1.2 g g–1; found 14.1±1.1 g g–1). The proposed procedure was used to analyze real samples of mussel products.  相似文献   

16.
The absorption spectra of 4f electron transitions of the complexes of neodymium and erbium with 5,7-dibromo-8-hydroxyquinoline in the presence of octylphenol poly(ethyleneglycol)ether have been studied by normal and third-derivative spectrophotometry. The proposed method is free of interference of other rare earths. The calibration graphs were linear up to 18 g/ml of neodymium and 21 g/ml of erbium (in the final solution). The derivative molar absorptivities are 395 l.mol–1.cm–1 for neodymium and 3421.mol–1.cm–1 for erbium. The corresponding values of Sandell's sensitivity were 0.36 and 0.49 g.cm–1, respectively. The relative standard deviations evaluated from ten independent determinations of 2.5 g/ml of neodymium and erbium are 1.5 and 3.8% for neodymium and 1.8 and 4.1% for erbium in absence and presence of 70 g of lanthanum, respectively. The detection limits (signal to noise ratio=2) are 0.23 g/ml for neodymium and 0.30 g/ml for erbium. The method has been used for the determination of neodymium and erbium in mixed rare earths with satisfactory results.  相似文献   

17.
Two simple, selective and sensitive spectrophotometric methods are described for the determination of 6-aminopenicillanic acid (6-APA). The methods are based on the reaction of 6-APA with either bromophenol blue (BPB) or bromothymol blue (BTB), to give orange-red and green species, respectively. The coloured products are quantified spectrophotometrically at 625 and 616 nm for BPB and BTB, respectively. The optimization of the different experimental conditions is described. No interferences from different -lactams and common degradation products were observed in the determination of 6-APA using BTB, while flucloxacillin, dicloxacillin, adrenaline, vitamin C, urea and common degradation products in any percentage interfere on using BPB only. The BTB method was better than the BPB method, because of its wider range of determination (0.4–20 g ml–1 vs. 0.4–7.2 g ml–1 on using BPB), higher molar absorptivity and Sandell sensitivity (3.27 × 103l mol–1 cm–1 and 0.099 g cm–2 vs. 2.82 × 103lmol–1 cm–1 and 0.115 g cm–2), greater stability (3 and 10 days on using BTB and BPB, respectively) and better selectivity. The results were compared with those given by the Official United States Pharmacopeial XXI method.  相似文献   

18.
A slurry-based electrothermal atomic absorption spectrometric procedure for the rapid determination of aluminium in chewing gum samples is discussed. To achieve a sufficiently small particle size, the samples have been first submitted to a mild calcination stage. Suspensions have been then prepared from the ground carbonaceous residues in a medium containing 8% v/v ethanol, 1% v/v concentrated nitric acid, 0.2% m/v magnesium nitrate and 4% v/v concentrated hydrogen peroxide. Aliquots of 10 l have been introduced in the furnace and dried at 200° C for 20 s. No ashing step has been used. Wall atomization has been performed at 2600° C. Calibration has been carried out with aqueous standards. The reliability of the procedure has been checked by analyzing standard reference materials and by comparing the results for eight commercial samples with those found by a conventional procedure based on the complete dissolution of the samples. The results for the commercial samples are in the 36–64 g g–1 range, only one of the samples giving a higher value of 123 g g–1.  相似文献   

19.
Summary The application of slurry nebulization/inductively coupled plasma mass spectrometry (ICP-MS) to trace elemental analysis of biological samples has been investigated. Three standard samples of the National Institute of Standards and Technology (NIST) were dispersed in 1% aqueous Triton X-100 solution by grinding with a planetary micronizing mill. The resulting slurries were nebulized into an ICP without any additional treatments. The 1% (m/v) slurry of the NIST bovine liver showed no significant influence on cone blockage and signal suppression/enhancement. Detection limit, precision and accuracy were discussed for the determination of 24 elements of interest in bovine liver, rice flour and pine needles. Detection limits ranged from 0.0001 g g–1 for U to 0.52 g g–1 for Zn at the effective integrating time of 10 s. For high mass elements, low blank values were obtained, yielding excellent limits (<0.01 g g–1). Acceptable accuracy and precision were obtained for most of the elements in the NIST bovine liver and rice flour, even for the volatile elements, such as As, Se and Br. However, relatively poor accuracy was obtained for the analysis of pine needles.  相似文献   

20.
A kinetic method for simultaneous determination of multielements is proposed, and a procedure for simultaneous determination of uranium(VI) and iron(II) is established based on their inductive effect on the chromium(VI)-iodide redox reaction in weak acidic medium. The reaction was monitored with the stopped-flow spectrophotometric technique by using I 3 -starch complex as indicator. The calibration graphs are linear for 0–3.6 g.cm–3 U(IV), and 0–2.5 g.cm–3 Fe(II), respectively. Most foreign ions, except for V(IV), Sb(III), do not interfere with the determination.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏