首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 62 毫秒
1.
Wang CC  Chiou SS  Wu SM 《Electrophoresis》2005,26(13):2637-2642
This study describes approaches for stacking a large volume of sample solutions containing a mixture of mercaptopurine monohydrate, 6-methylmercaptopurine, thioguanine, thioguanosine, and thioxanthine in capillary electrophoresis (CE). After filling the run buffer (60 mM borate buffer, pH 8.5), a large sample volume was loaded by hydrodynamic injection (2.5 psi, 99.9 s), followed by the removal of the large plug of sample matrix from the capillary using polarity switching (-15 kV). Monitoring the current and reversing the polarity when 95% of current recovered, the separation of anionic analytes was performed in a run buffer < 20 kV. Around 44- to 90-fold improvement of sensitivity for five analytes was achieved by large-volume stacking with polarity switching when compared with CE without stacking. This method was feasible for determination of the analytes spiked in plasma. Removing most of electrolytes from plasma is a key step for performing large-volume sample stacking. Solid-phase extraction was used for pretreatment of biological samples. To our knowledge, this study is one of few applications showing the possibilities of this stacking procedure to analyze biological samples by large-volume sample stacking with polarity switching (LVSSPS) in CE.  相似文献   

2.
Almeda S  Arce L  Valcárcel M 《Electrophoresis》2008,29(14):3074-3080
A reliable MEKC method for the identification and quantitation of traces of the nonsteroidal anti-inflammatory drugs (NSAIDs) ketoprofen, fenbufen and indomethacin in saliva is proposed. Using CE to analyze biological samples often requires suppressing the interferences and peak broadening typically resulting from high-conductivity sample matrices. We addressed this problem by using Microcon, a centrifugal filter device, to reduce the viscosity of saliva and exclude most higher-molecular-mass substances. This initial pretreatment was followed by the combined used of off-line SPE to isolate and concentrate the analytes, and large-volume stacking with polarity switching (LVSS) in the capillary. These two preconcentration steps allow the determination of NSAIDs at concentrations above 0.1 microg/L; therefore, the proposed SPE/LVSS/MEKC method affords a 500-fold sensitivity enhancement relative to conventional CE injection. The LODs obtained afford the determination of NSAIDs in saliva, where analytes can be present at the microgram-per-liter level.  相似文献   

3.
《Analytical letters》2012,45(18):2853-2867
Abstract

A capillary electrophoresis method with large volume sample stacking (CE-LVSS) has been developed and validated for the simultaneous determination of seven phenolic compounds: naringin, rutin, carnosic acid, apigenin, quercetin, morin, and chichoric acid. Optimization was carried out by response surface methodology and a set of 20 experiments helped to optimize the parameters such as the concentration of buffer, buffer pH, and applied voltage. Analytes were separated using a 50?µm diameter capillary with 56?cm effective length and an extended light path using 20?mM borate buffer at pH 9.2. The LVSS method was optimized and a three- to fivefold improvement in detectability was achieved with injection at 100 mbar for 20?s followed by polarity switching at –20?kV for 6?s. The linearity values of all seven analytes were observed in the concentration ranges from 0.5 to 50?µg/mL for CE and 0.1 to 25?µg/mL for LVSS. The limits of detection were from 0.012 to 0.241 and 0.003 to 0.086?µg/mL for CE and LVSS. The obtained limits of quantitation were within 0.041 to 0.802 for CE and 0.012 to 0.286?µg/mL for LVSS. The recoveries were between 91.1 and 109.8% and 96.3 and 108.4% for CE and LVSS, respectively. The developed method has been successfully applied for the quantitative determination of analyzed components from food samples that are important sources of these compounds.  相似文献   

4.
In this work, we overcame the deficiencies of large volume sample stacking (LVSS) in separating low‐mobility and neutral analytes through combining LVSS with sweeping in CE, and employed this new approach to enrich and separate neutral and anionic analytes simultaneously. This technique was carried out with pressure injection of large‐volume sample followed by EOF as a pump pushing the bulk of low‐conductivity sample matrix out of the outlet of the capillary while analytes were swept by micelles and separated via MEKC without the electrode polarity switching. Careful optimization of the enrichment and separation conditions allowed the enrichment factors (EFs) of peak height and peak area of the analytes to be in the range of 9–33 and 21–35 comparing with the conventional injection mode, respectively. The five analytes were baseline separated in 15 min and the detection limits ranged from 26.5 to 55.8 ng/mL (S/N = 3). The developed method was successfully applied to determine adenine, caffeine, theophylline, reduced L‐glutathione (GSH) and oxidized L‐glutathione (GSSG) in two different teas with recoveries that ranged from 84.4 to 105.2%.  相似文献   

5.
This paper describes two different approaches for increasing the sensitivity for the analysis of ceftiofur by capillary electrophoresis (CE). Two different techniques based on the introduction of an enlarged volume of sample, namely large volume sample stacking (LVSS) and in-line solid phase extraction (SPE) were studied and compared. LVSS allowed the on-column electrophoretic preconcentration of ceftiofur without modification of the separation capillary. In-line SPE-CE was developed by using a home-made microcartridge that was filled with a reversed-phase sorbent (C18). The microcartridge was coupled in-line near the inlet of the separation capillary. LVSS and in-line SPE-CE allowed automated operation and improved sensitivity for the analysis of ceftiofur with respect to conventional CE. When environmental water samples were analyzed, an additional pretreatment step based on off-line SPE was necessary in both cases to further decrease the detection limits. In terms of sensitivity for the determination of ceftiofur in river water samples, the combination of off-line SPE with in-line SPE-CE was found the most sensitive with a detection limit of 10 ng L−1, whereas the method based on the use of off-line SPE with LVSS presented a detection limit of 100 ng L−1.  相似文献   

6.
We present a new system for the sensitive analysis of cephalosporins by CE using both on-line SPE and large-volume sample stacking (LVSS). Sample volumes of 250 muL were loaded onto the SPE microcolumn which was then desorbed with 426 nL of ACN. The SPE elution plug was injected into the CE system via an in-line valve interface filling approximately 60% of the volume of the separation capillary. Subsequently, LVSS was performed by applying a voltage of -5 kV, which resulted in the simultaneous removal of the elution solvent and the preconcentration of the analytes in a narrow zone. This way the amount of analyte loaded into the capillary could be considerably increased without serious loss of CE separation efficiency. LODs for cefoperazone and ceftiofur were in the ng/L range which represents an improvement of a factor of 8450 and 11 450 when compared with direct CE injection. The cephalosporin test compounds presented a good linear response (corrected peak area) between 0.5 and 10 mug/L with correlation coefficients higher than 0.995. The final method is compared with previously reported LVSS-CE and SPE-CE systems for the analysis of cephalosporins.  相似文献   

7.
To improve the sensitivity of the UV-detection for the determination of trace amounts of albumin by capillary zone electrophoresis (CZE), five on-line preconcentration techniques, including field-amplified sample stacking (FASS), head-column field-amplified sample stacking (HC-FASS), stacking with a polymer solution, dynamic pH junction and large volume sample stacking (LVSS) with reversed polarity, were compared. Sensitivity enhancement factor and reproducibility were two factors that were used to assess the suitability of each method. To minimize protein adsorption on the capillary wall, capillaries were covalently modified with anionic polymer, poly(sulfopropylmethacrylate) coating. All used methods have good reproducibility. The maximum sensitivity enhancement factor (about 67-fold in terms of peak heights) was achieved with LVSS technique. The concentration limit of detection (LOD) (S/N=3) for the human serum albumin obtained with the optimized LVSS approach was 15 microg/ml with UV-detection. The method was further evaluated for the analysis of urine samples with gel-filtration-based sample-desalting procedure.  相似文献   

8.
A capillary zone electrophoresis (CZE) method with UV-vis detection has been developed for the simultaneous monitoring of the major degradation products of metribuzin, i.e. deaminometribuzin (DA), deaminodiketometribuzin (DADK) and diketometribuzin (DK). The dissociation acid constants have also been estimated by CE and no significant differences have been observed with the values obtained by applying other techniques. Optimum separation has been achieved in less than 9 min in 40 mM sodium tetraborate buffer, pH 9.5 by applying a voltage of 15kV at 25 degrees C and using p-aminobenzoic acid as internal standard. In order to increase sensitivity, large volume sample stacking (LVSS) with polarity switching has been applied as on-line pre-concentration methodology. Detection limits of 10, 10 and 20 ng/mL for DA, DADK and DK, respectively were obtained. The method has been applied to soil samples, after pressurized liquid extraction (PLE). Samples were extracted at high temperature (103 degrees C and 1500 psi) using methanol as extraction solvent and sodium sulphate as drying agent. This PLE procedure was followed by an off-line pre-concentration and sample clean-up procedure by solid-phase extraction (SPE) using a LiChrolut EN sorbent column. These last two procedures were also suitable for the direct treatment of groundwater samples before CE analysis. The combination of both off-line and on-line pre-concentration procedures provided a significant improvement in sensitivity. LVSS provided pre-concentration factors of 4, 36 and 28 for DK, DA and DADK, respectively and with SPE a pre-concentration of 500-fold for the case of water samples and of 2.5-fold in the case of soil samples was obtained. The method is suitable for the monitoring of these residues in environmental samples with high sensitivity, precision and satisfactory recoveries.  相似文献   

9.
Several strategies, namely, large volume sample stacking (LVSS), field‐amplified sample injection (FASI), sweeping, and in‐line SPE‐CE, were investigated for the simultaneous separation and preconcentration of a group of parabens. A BGE consisting of 20 mM sodium dihydrogenphosphate (pH 2.28) and 150 mM SDS with 15% ACN was used for the separation and preconcentration of the compounds by sweeping, and a BGE consisting of 30 mM sodium borate (pH 9.5) was used for the separation and preconcentration of the compounds by LVSS, FASI, and in‐line SPE‐CE. Several factors affecting the preconcentration process were investigated in order to obtain the maximum enhancement of sensitivity. The LODs obtained for parabens were in the range of 18–27, 3–4, 2, and 0.01–0.02 ng/mL, and the sensitivity evaluated in terms of LODs was improved up to 29‐, 77‐, 120‐, and 18 400‐fold for sweeping, LVSS, FASI, and in‐line SPE‐CE, respectively. These preconcentration techniques showed potential as good strategies for focusing parabens. The four methods were validated with standard samples to show the potential of these techniques for future applications in real samples, such as biological and environmental samples.  相似文献   

10.
An in‐capillary 2, 2‐diphenyl‐1‐picrylhydrazyl (DPPH)‐CE‐the DAD (in‐capillary DPPH‐CE‐DAD) combined with reversed‐electrode polarity stacking mode has been developed to screen and quantify the active antioxidant components of Cuscuta chinensis Lam. The operation parameters were optimized with regard to the pH and concentration of buffer solution, SDS, β‐CDs, organic modifier, as well as separation voltage and temperature. Six antioxidants including chlorogenic acid, p‐coumaric acid, rutin, hyperin, isoquercitrin, and astragalin were screened and the total antioxidant activity of the complex matrix was successfully evaluated based on the decreased peak area of DPPH by the established DPPH‐CE‐DAD method. Sensitivity was enhanced under reversed‐electrode polarity stacking mode and 10‐ to 31‐fold of magnitude improvement in detection sensitivity for each analyte was attained. The results demonstrated that the newly established in‐capillary DPPH‐CE‐DAD method combined with reversed‐electrode polarity stacking mode could integrate sample concentration, the oxidizing reaction, separation, and detection into one capillary to fully automate the system. It was considered a suitable technique for the separation, screening, and determination of trace antioxidants in natural products.  相似文献   

11.
This paper describes approaches for stacking large volumes of sample solutions containing a mixture of chlorophenols and chlorophenoxyacetic acids as their anions in capillary zone electrophoresis, and compares results to standard capillary electrophoresis (CE) and normal stacking modes. In order to increase the amount of sample injected beyond the optimal conditions and maintain high resolution, the sample introduction buffer must be removed after the stacking process is completed. This is achieved by pumping the sample buffer out of the column using polarity switching. Large sample volumes are loaded by hydrodynamic injection, then stacked at the injection buffer/run electrolyte interface, followed by the removal of the large plug of low-conductivity sample matrix from the capillary column using polarity switching and finally the separation of the stacked anions in a basic buffer (pH 8.65). Around 10- and 40-fold improvement of sensitivity was achieved by normal stacking and large-volume stacking with polarity switching, respectively, when compared to the standard CE analysis. Sweeping-micellar electrokinetic capillary chromatography (MEKC) was also investigated for the purpose of comparison to the stacking technique. The method should be suitable for the analysis of these chemical compound classes in industrial chlorophenoxyacetic acid manufacture.  相似文献   

12.
Large‐volume sample stacking (LVSS) is commonly used as an effective online preconcentration method in capillary zone electrophoresis (CZE). In this paper, the method LVSS combined with CZE has been proposed to analyze camptothecin alkaloids. Optimum separation can be achieved in the following conditions: pH 9.0; 25mm borate buffer containing 20 mm sulfobutylether‐β‐cyclodextrin and 20 mm ionic liquid 1‐ethyl‐3‐methyllimidazole l ‐lactate; applied voltage 20 kV; and capillary temperature 25 °C. The LVSS was optimized as hydrodynamic injection 4 s at 5.0 psi and the polarity switching time was 0.17 min. Under the above conditions, the analytes could be separated completely in <20 min and the detector response was increased compared with conventional hydrodynamic injection. The limits of detection were between 0.20 and 0.78 μg/L. A good linearity was obtained with correlation coefficients from 0.9991 to 0.9997. The recoveries ranged from 97.72 to 103.2% and the results demonstrated excellent accuracy. In terms of the migration time and peak area, the experiment was reproducible. The experimental results indicated that baseline separation can be obtained and this method is suitable for the quantitative determination of camptothecin alkaloids in real samples.  相似文献   

13.
A capillary electrophoresis method is proposed to analyze the four most well-known growth hormone–releasing hormone (GHRH) analogs that are misused by athletes. Dimethyl-β-cyclodextrin used as a chiral selector allowed, for the first time, the separation of those basic peptide analogs, including enantiopeptides (sermorelin and CJC-1293) that differ by the chirality of only one amino acid. To increase the method sensitivity, electrokinetic preconcentration methods have been investigated. The large volume sample stacking with polarity switching (PS-LVSS) method with an injected sample volume corresponding to 80% of the capillary one was found superior to the sweeping in terms of signal enhancement factor (SEF). Acid and organic solvent addition to the sample (0.1 mM phosphoric acid with 30% methanol) led to a twofold signal improvement, when compared to water as a matrix. We increased capillary dimensions to provide a signal enhancement through the injection of a larger sample volume. Finally, using a combination of the optimized PS-LVSS preconcentration with the chiral capillary zone electrophoresis (CZE), the GHRH analogs were separated and limits of detection between 75 and 200 ng/mL were reached. This method was successfully applied to urine after a desalting step. An optimized C18 SPE was used for that purpose in order to provide low sample conductivity (<130 µS/cm) and preserve the efficiency of LVSS preconcentration. SEF of 640 was obtained with desalted urine spiked with sermorelin by comparison to the CZE (without preconcentration) method.  相似文献   

14.
The reaction between α,α-dialkylated amino acids and amino acid N-carboxyanhydrides is slow leading to low concentrations of products (peptides). The detection by capillary electrophoresis of the analytes contained in such samples is therefore a challenging issue. In this work, on-line sample pre-concentration methods based on field-amplified sample stacking have been implemented and compared. Because of the high ionic strength present in the sample matrix, samples were diluted with an organic solvent prior to analysis to decrease the sample conductivity. Different modes of sample injection (field amplified sample injection (FASI), hydrodynamic normal sample stacking (NSS) or large volume sample stacking (LVSS)) were compared. Pre-concentration factors of 20 for FASI, about 30–40 for NSS and 60 for LVSS were obtained for the analysis of (l,l) dipeptide of valine in a large excess of isovaline and 0.2 M of ionic strength. For LVSS application and resolution optimisation, a new non-covalent coating based on the partial modification of the capillary surface was used to tune the electroosmotic flow magnitude and to pump the sample matrix out of the capillary. This on-line sample pre-concentration step allowed confirming that oligopeptides including α,α-dialkylated amino acids are formed during the reaction between α,α-dialkylated amino acids and N-carboxyanhydride amino acids.  相似文献   

15.
Sun B  Macka M  Haddad PR 《Electrophoresis》2003,24(12-13):2045-2053
Stacking techniques used independently and also with a high-sensitivity cell (HSC) were employed to optimise sensitivity and detection limits in the direct photometric detection of the following eight arsenic species by capillary zone electrophoresis (CZE): arsenite, arsenate, monomethylarsonic acid (MMA), dimethylarsinic acid (DMA), 4-hydroxy-3-nitrophenylarsonic acid (Roxarsone), p-aminophenylarsonic acid (p-ASA), 4-nitrophenylarsonic acid (4-NPAA), and phenylarsonic acid (PAA) (target analytes). The stacking mechanisms, optimised stacking and separation conditions, and concentration sensitivity enhancement factors were discussed and compared for (i) normal stacking mode (NSM, sometimes also referred to as field-amplified stacking) in an uncoated fused-silica capillary in the counter-electroosmotic flow (EOF) mode, (ii) large-volume sample stacking (LVSS) with polarity switching, and (iii) the less often applied stacking method of co-EOF NSM stacking with EOF reversal using a poly(diallydimethylammonium chloride) (PDDAC)-coated capillary. The optimal injection volumes were 7.4, 60 and 17.2% of the total capillary volume, for the above three methods, respectively. LVSS with polarity switching gave the lowest limit of detection (LOD). The use of the HSC further reduced the LOD of each target analytes by a factor of 5-8 times. By combining LVSS and HSC, LODs of the target analytes could be reduced by a factor of 218-311, to 5.61, 9.15, 11.1, and 17.1 microg/L for As(III), DMA, MMA, and As(V), respectively. The method was demonstrated to be applicable to the determination of the target analytes in tap water and lake water, with recoveries in the range of 89.4-103.3%.  相似文献   

16.
Two in‐line enrichment procedures (large volume sample stacking (LVSS) and field amplified sample injection (FASI)) have been evaluated for the CZE analysis of haloacetic acids (HAAs) in drinking water. For LVSS, separation on normal polarity using 20 mM acetic acid–ammonium acetate (pH 5.5) containing 20% ACN as BGE was required. For FASI, the optimum conditions were 25 s hydrodynamic injection (3.5 kPa) of a water plug followed by 25 s electrokinetic injection (?10 kV) of the sample, and 200 mM formic acid–ammonium formate buffer at pH 3.0 as BGE. For both FASI and LVSS methods, linear calibration curves (r2>0.992), limit of detection on standards prepared in Milli‐Q water (49.1–200 μg/L for LVSS and 4.2–48 μg/L for FASI), and both run‐to‐run and day‐to‐day precisions (RSD values up to 15.8% for concentration) were established. Due to the higher sensitive enhancement (up to 310‐fold) achieved with FASI‐CZE, this method was selected for the analysis of HAAs in drinking water. However, for an optimal FASI application sample salinity was removed by SPE using Oasis WAX cartridges. With SPE‐FASI‐CZE, method detection limits in the range 0.05–0.8 μg/L were obtained, with recoveries, in general, higher than 90% (around 65% for monochloroacetic and monobromoacetic acids). The applicability of the SPE‐FASI‐CZE method was evaluated by analyzing drinking tap water from Barcelona where seven HAAs were found at concentration levels between 3 and 13 μg/L.  相似文献   

17.
Cugat MJ  Borrull F  Calull M 《The Analyst》2001,126(8):1312-1317
We investigated the on-line preconcentration of a test mixture of 15 substituted and unsubstituted naphthalene(NSs) and benzenesulfonates (BZSs) by large-volume sample stacking (LVSS). Analyses were carried out by capillary zone electrophoresis (CZE) with on-column UV detection. In particular, we focused on how experimental variables such as the inside diameter of the capillary, the volume of sample introduced and polarity switching influenced the enrichment procedure. The best results were obtained when 300 nl were injected and stacked using a bubble cell capillary. Under these conditions, LVSS increased the detector response of conventional hydrodynamic injection by a factor of 40. The limits of detection of the method were between 5 and 10 microg l(-1). Determinations were reproducible, in terms of peak area and migration time, under such conditions. The performance of the method was examined by determining NS and BZS in real samples, such as tap, river and surface waters and inflow/outflow waters from a water treatment plant. Real samples were injected directly into the CZE column with little or no preparation.  相似文献   

18.
In capillary electrophoresis, the short optical path length associated with on-column UV detection imposes an inherent detection problem. Detection limits can be improved using sample stacking. Recently, large-volume sample stacking (LVSS) without polarity switching was demonstrated to improve detection limits of charged analytes by more than 100-fold. However, this technique requires suppression of the electroosmotic flow (EOF) during the run. This necessitates working at a low pH, which limits using pH to optimize selectivity. We demonstrate that LVSS can be performed at any buffer pH (4.0-10.0) if the zwitterionic surfactant Rewoteric AM CAS U is used to suppress the EOF. Sensitivity enhancements of up to 85-fold are achieved with migration time, corrected area, and peak height reproducibility of 0.8-1.6%, 1.3-3.7%, and 0.8-4.9%, respectively. Further, it is possible to stack either positively or negatively charged analytes using zwitterionic surfactants to suppress the EOF.  相似文献   

19.
采用大体积样品堆积(LVSS)在线富集模式,建立了高效毛细管电泳(HPCE)测定蒲公英中阿魏酸、绿原酸和咖啡酸含量的方法。主要考察了在毛细管区带电泳(CZE)分离模式下,缓冲液的pH和浓度对分离效果的影响,以及在LVSS在线富集模式下,进样时间对富集效果的影响。在最优条件下阿魏酸、绿原酸和咖啡酸可在12 min内得到分离,3个成分在0.5~25.0μg/mL浓度范围内均有较好的线性关系(r2=0.999),平均加样回收率分别为104.9%,98.0%和100.1%,RSD(n=6)分别为3.6%,2.6%和1.0%。定量限(S/N=10)分别为0.10,0.10和0.03μg/mL,检出限(S/N=3)分别为0.03,0.03和0.01μg/mL。相对于常规CZE模式,本方法的富集效果倍数为17~19倍。建立的方法可用于蒲公英的日常检测与质量控制。  相似文献   

20.
Zhang H  Zhou L  Chen X 《Electrophoresis》2008,29(7):1556-1564
An easy, simple, and highly efficient on-line preconcentration method for polyphenolic compounds in CE was developed. It combined two on-line concentration techniques, large-volume sample stacking (LVSS) and sweeping. The analytes preconcentration technique was carried out by pressure injection of large-volume sample followed by the EOF as a pump pushing the bulk of low-conductivity sample matrix out of the outlet of the capillary without the electrode polarity switching technique using five polyphenols as the model analytes. Identification and quantification of the analytes were performed by photodiode array UV (PDA) detection. The optimal BGE used for separation and preconcentration was a solution composed of 10 mM borate-90 mM sodium cholate (SC)-40% v/v ethylene glycol, without pH adjustment, the applied voltage was 27.5 kV. Under optimal preconcentration conditions (sample injection 99 s at 0.5 psi), the enhancement in the detection sensitivities of the peak height and peak area of the analytes using the on-line concentration technique was in the range of 18-26- and 23-44-fold comparing with the conventional injection mode (3 s). The detection limits for (-)-epigallocatechin (EGC), (-)-epicatechin (EC), (+)-catechin (C), (-)-epigallocatechin gallate (EGCG), and (-)-epicatechin gallate (ECG) were 4.3, 2.4, 2.2, 2.0, and 1.6 ng/mL, respectively. The five analytes were baseline-separated under the optimum conditions and the experimental results showed that preconcentration was well achieved.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号