首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
Three-dimensional model of a convective heat exchange in the apparatus with two blade agitators equipped with an outside heating device was formulated using the equations of laminar motion of viscous fluid and of energy. The Arrhenius-Frenkel-Eyring equation was used to account for the temperature dependence on the fluid viscosity. A numerical computations of the fields of velocity, pressure, and temperature were performed with algorithm Simple. The results were presented as isotherms in the meridional, and in the horizontal sections of apparatus.  相似文献   

2.
The present state of hydrodynamics and mass transfer studies in segmented gas-liquid flow in microchannels has been analyzed. It has been shown that such parameters as gas bubble velocity, gas hold-up, relative gas bubble length, pressure drop, mass transfer coefficients from gas bubbles to liquid slugs and to liquid film, as well as mass transfer coefficient from liquid to channel wall can be satisfactorily predicted. Nevertheless, some correlations were obtained under definite conditions and should be summarized. The purpose of further research is to develop reliable methods for calculation of mass transfer coefficients as functions of channel geometry, phase properties, and phase velocities in mini- and microchannels.  相似文献   

3.
Results of an experimental study of carbon dioxide desorption from water in a rotary apparatus are presented. The manner in which the volume mass-transfer coefficient in the fluid phase and the efficiency of mass transfer vary with a number of mode parameters was determined. Analytical dependences for calculating the hydraulic resistance and the rotor drive power were derived. These dependences will allow development of a procedure for engineering calculations of apparatus of this type.  相似文献   

4.
A solution of the problem of mass transfer in a turbulent boundary layer has been obtained with a first-order chemical reaction occurring in the liquid phase. The dependence of the enhancement factor for absorption and of the mass transfer coefficient on the model parameters can be used for building up a hierarchic model of the gas-liquid reactor.
. .
  相似文献   

5.
Methods of programming temperature and flow rate of carrier gas for to reducing the time of analyte separation on polycapillary columns (PCC) are compared. As was shown, the programming of temperature is accompanied by a change of peak shape, associated with the irregular heating of PCC capillaries. The programming of carrier gas flow rate does not distort the shape of chromatography peaks and does not require long time to return the system to the starting conditions.  相似文献   

6.
Fundamental aspects of the chromatomembrane mass exchange in the liquid-gas system are considered for the case of saturation with oxygen (oxygenation) of a physiological solution. The influence exerted by the geometrical dimensions and macroporous structure of a biporous matrix on the process efficiency is revealed.Translated from Zhurnal Prikladnoi Khimii, Vol. 77, No. 11, 2004, pp. 1783–1786.Original Russian Text Copyright © 2004 by Moskvin, Grigorev, Rodinkov, Senchik.  相似文献   

7.
In recent years, nanobubble technologies have drawn great attention due to their wide applications in many fields of science and technology. From previous studies, a kind of honeycomb structure for high efficiency nanobubble generation has been proposed. In this paper, the numerical simulations of bubbly flow in the honeycomb structure were performed by using a computational fluid dynamics–population balance model (CFD-PBM) coupled model. The numerical model was based on the Eulerian multiphase model and the population balance model (PBM) was used to calculate the bubble size distribution. The bubble size distributions in the honeycomb structure under different work conditions were predicted. Two different drag force models (Schiller-Naumann model and Tomiyama model) and two different aggregation models (Luo model and turbulent aggregation model) were investigated. Both two drag models gave similar prediction of bubble number density distribution at the outlet. The results obtained from Luo model had better reflection of the trend of number density distribution. The turbulence dissipation rate ε can be used to evaluate the nanobubble generating ability. The water tank was not included in the CFD model in this work. The bubbles in the water tank should be studied in the future.  相似文献   

8.
Journal of Thermal Analysis and Calorimetry - In this paper, it has been discussed a nonlocal fractional model of viscous nanofluid holding a hybrid nanostructure. Hybridized copper (Cu) and...  相似文献   

9.
Gas hydrates are ice-like crystalline compounds, which form through a combination of water and suitably sized guest molecules under low temperature and elevated pressure conditions. These solid compounds give rise to problems in the natural gas oil industry because they can plug pipelines and process equipment. Low dosage hydrate inhibitors are a recently developed hydrate control technology, which can be more cost-effective than traditional practices such as methanol and glycols. The kinetics of hydrate growth has been modeled by numerous authors who have measured the gas consumption rate during hydrate formation in batch agitator reactors.  相似文献   

10.
11.
通过双流体模型对射流流化床煤气化炉进行了CFD(Computational Fluid Dynamics,计算流体力学)模拟。模拟着重分析了流化床气化炉气固流动的特性和传质、传热过程。结果表明,流化床中气固两相的传热、传质过程与气体和颗粒的运动特性密切相关。  相似文献   

12.
13.
An expression has been derived for the time dependence of the NMR line shape for systems with many-site chemical exchange in the absence of spin-spin coupling, in a zero saturation limit. The dynamics of variation of the NMR line shape with time is considered in detail for the case of two-site chemical exchange. Mathematica programs have been designed for numerical simulation of the NMR spectra of chemical exchange systems. The analytical expressions obtained are useful for NMR line shape simulations for systems with photoinduced chemical exchange.  相似文献   

14.
High-speed counter-current chromatography (HSCCC), a separation technique based solely on the partitioning of solutes between two immiscible liquid phases, was applied for the fractionation of technical toxaphene, an organochlorine pesticide which consists of a complex mixture of structurally closely related compounds. A solvent system (n-hexane/methanol/water 34:24:1, v/v/v) was developed which allowed to separate compounds of technical toxaphene (CTTs) with excellent retention of the stationary phase (Sf = 88%). Subsequent analysis of all HSCCC fractions by gas chromatography coupled to electron-capture negative ion mass spectrometry (GC/ECNI-MS) provided a wealth of information regarding separation characteristics of HSCCC and the composition of technical toxaphene. The visualization of the large amount of data obtained from the offline two-dimensional HSCCC–GC/ECNI-MS experiment was facilitated by the creation of a two-dimensional (2D) contour plot. The contour plot not only provided an excellent overview of the HSCCC separation progress, it also illustrated the differences in selectivity between HSCCC and GC. The results of this proof-of-concept study showed that the 2D chromatographic approach involving HSCCC facilitated the separation of CTTs that coelute in unidimensional GC. Furthermore, the creation of 2D contour plots may provide a useful means of enhancing data visualization for other offline two-dimensional separations.  相似文献   

15.
Reaction columns containing a packing of KOD or D3PO4 in a stationary liquid phase on a support as components in a gas chromatograph/mass spectrometer were shown to provide selective basic H/D exchange of fluorenes and furans and acidic H/D exchange of thiophenes under gas-phase conditions. Such columns were proposed for use in the study of fragmentation mechanisms and establishment of the position of substituents in the ring.Translated from Izvestiya Akademii Nauk SSSR, Seriya Khimicheskaya, No. 3, pp. 739–740, March, 1991.  相似文献   

16.
The critical gas saturation, S(gc), denotes the volume fraction of the gas phase at the onset of bulk gas flow during the depressurization of a supersaturated liquid in a porous medium. In the absence of gradients due to viscous or gravity forces, S(gc) is controlled by nucleation, capillary forces, and the rate of decline of the supersaturation. In this paper we address one important additional effect, that of buoyancy. We use 2-D pore-network simulations, based on invasion percolation in a gradient (IPG), and corresponding scaling relations to obtain the dependence of S(gc) on the gravity Bond number, B, under conditions of slow growth, namely when mass transfer is sufficiently fast. The critical gas saturation approaches two plateau values at low and high Bond numbers. In the in-between region it scales as a power law of B, which for a 2-D lattice is S(gc) approximately B(-0.91).  相似文献   

17.
18.
Summary A systematic derivation of corresponding equations shows that averaging the pressure and the flow rate of the mobile phase in a gas chromatographic column over the column length and over the time that an unretained component resides in the column, requires the use of three different compressibility correction factors,j 2 1 ,j 3 2 , andj 4 3 . When multiplied by the adjusted retention volume,V R-VM, the Martin and James mobile phase compressibility correction factorj 3 2 , only, produces the value of specific retention volume,V g T , which is connected unambiguously with the thermodynamic phase distribution coefficient,K, of the sorbate.  相似文献   

19.
The improved analytical capability of direct-current (dc) and radiofrequency (rf) fast flow glow discharges coupled to a sector field mass spectrometer (GD-SFMS) are presented. In particular, the effect of GD chamber design has been studied to obtain suitable crater shapes for depth-profile analysis of solid samples while maintaining the high sensitivity and stability of this source. In this study it was observed that the distance between the sample surface and the end of the flow tube is critical and so careful optimisation is needed. Under optimum conditions plane crater profiles, with high ion-signal sensitivity and sufficient stability, were obtained. The capability to determine qualitative and semi-quantitative depth profiles is presented here using, as model, a coated sample of certified thickness. Finally, the depth resolution achieved for qualitative depth profiles obtained by rf-GD-(SF)MS is compared with that for the well-established rf-GD optical emission spectroscopy (OES) technique.Dedicated to the memory of Wilhelm Fresenius  相似文献   

20.
The main objective of the present work is enhancement of the performance of gas hydrate kinetic inhibitors in the presence of polyethylene oxide (PEO) and polypropylene oxide (PPO) for simple gas hydrate formation in a flow mini-loop apparatus. PEO and PPO are high molecular weight polymers that are not kinetic inhibitors by their self. For this investigation, a laboratory flow mini-loop apparatus was set up to measure the induction time and rate of gas hydrate formation when a hydrate-forming substance (such as C1, C3, CO2 and i-C4) is contacted with water containing dissolved inhibitor in presence or absence of PEO or PPO under suitable temperature and pressure conditions. In each experiment, water containing inhibitors blend saturated with pure gas is circulated up to a required pressure. Pressure is maintained at a constant value during experimental runs by means of required gas make-up. The effect of PEO and PPO on induction time and gas consumption during hydrate formation is investigated in the presence or absence of PVP (polyvinylpyrrolidone) and l-tyrosine as kinetic inhibitors. Results were shown that the induction time is prolonged in the presence of PEO or PPO compared to the inhibitor only. Inclusion of PPO into a kinetic hydrate inhibitor solution shows a higher enhancement in its inhibiting performance compare to PEO. Thus, the induction time for simple gas hydrate formation in presence of kinetic hydrate inhibitor with PPO is higher, compare to kinetic hydrate inhibitor with PEO.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号