首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 187 毫秒
1.
One of the most important challenges in medical treatment is invention of a minimally invasive approach in order to induce lethal damages to cancer cells. Application of high intensity focused ultrasound can be beneficial to achieve this goal via the cavitation process. Existence of the particles and vapor in a liquid decreases the ultrasonic intensity threshold required for cavitation onset. In this study, synergism of intense pulsed light (IPL) and gold nanoparticles (GNPs) has been investigated as a means of providing nucleation sites for acoustic cavitation. Several approaches have been reported with the aim of cavitation monitoring. We conducted the experiments on the basis of sonochemiluminescence (SCL) and chemical dosimetric methods. The acoustic cavitation activity was investigated by determining the integrated SCL signal acquired over polyacrylamide gel phantoms containing luminol in the presence and absence of GNPs in the wavelength range of 400–500 nm using a spectrometer equipped with cooled charged coupled devices (CCD) during irradiation by different intensities of 1 MHz ultrasound and IPL pulses. In order to confirm these results, the terephthalic acid chemical dosimeter was utilized as well. The SCL signal recorded in the gel phantoms containing GNPs at different intensities of ultrasound in the presence of intense pulsed light was higher than the gel phantoms without GNPs. These results have been confirmed by the obtained data from the chemical dosimetry method. Acoustic cavitation in the presence of GNPs and intense pulsed light has been suggested as a new approach designed for decreasing threshold intensity of acoustic cavitation and improving targeted therapeutic effects.  相似文献   

2.
Acoustic cavitation plays an important role in sonochemical processes and the rate of sonochemical reaction is influenced by sonication parameters. There are several methods to evaluate cavitation activity such as chemical dosimetry. In this study, to comparison between iodide dosimetry and terephthalic acid dosimetry, efficacy of sonication parameters in reactive radical production has been considered by iodide and terephthalic acid dosimetries. For this purpose, efficacy of different exposure parameters on cavitations production by 1 MHz ultrasound has been studied. The absorbance of KI dosimeter was measured by spectrophotometer and the fluorescence of terephthalic acid dosimeter was measured using spectrofluorometer after sonication. The result of experiments related to sonication time and intensity showed that with increasing time of sonication or intensity, the absorbance is increased. It has been shown that the absorbance for continuous mode is remarkably higher than for pulsing mode (p-value < 0.05). Also results show that with increasing the duty cycles of pulsed field, the inertial cavitation activity is increased. With compensation of sonication time or intensity in different duty cycles, no significant absorbance difference were observed unless 20% duty cycle. A significant correlation between the absorbance and fluorescence intensities (count) at different intensity (R = 0.971), different sonication time (R = 0.999) and different duty cycle (R = 0.967) were observed (p-value < 0.05). It is concluded that the sonication parameters having important influences on reactive radical production. These results suggest that there is a correlation between iodide dosimetry and terephthalic acid dosimetry to examine the acoustic cavitation activity in ultrasound field.  相似文献   

3.
Currently several therapeutic applications of ultrasound in cancer treatment are under progress which uses cavitation phenomena to deliver their effects. There are several methods to evaluate cavitation activity such as chemical dosimetry and measurement of subharmonic signals. In this study, the cavitation activity induced by the ultrasound irradiation on exposure parameters has been measured by terephthalic acid chemical dosimetry and subharmonic analysis. Experiments were performed in the near 1 MHz fields in the progressive wave mode and effect of duty cycles changes with 2 W/cm2 intensity (ISATA) and acoustic intensity changes in continuous mode on both fluorescence intensity and subharmonic intensity were measured. The dependence between fluorescence intensity of terephthalic acid chemical dosimetry and subharmonic intensity analysis were analyzed by Pearson correlation (p-value < 0.05). It has been shown that the subharmonic intensity and the fluorescence intensity for continuous mode is higher than for pulsing mode (p-value < 0.05). Also results show that there is a significant difference between the subharmonic intensity and the fluorescence intensity with sonication intensity (p-value < 0.05). A significant correlation between the fluorescence intensity and subharmonic intensity at different duty cycles (R = 0.997, p-value < 0.05) and different intensities (R = 0.985, p-value < 0.05) were shown. The subharmonic intensity (μW/cm2) significantly correlated with the fluorescence intensity (count) (R = 0.901; p < 0.05) and the fluorescence intensity due to chemical dosimetry could be estimated with subharmonic intensity due to subharmonic spectrum analysis. It is concluded that there is dependence between terephthalic acid chemical dosimetry and subharmonic spectrum analysis to examine the acoustic cavitation activity.  相似文献   

4.
《Ultrasonics》2013,53(1):29-35
The particles in a liquid decrease the ultrasonic intensity threshold required for cavitation onset. In this study, a new nanoconjugate composed of Protoporphyrin IX and gold nanoparticles (Au–PpIX) was used as a nucleation site for cavitation. The nonradiative relaxation time of Protoporphyrin IX in the presence of gold nanoparticles is longer than the similar time without gold nanoparticles. The acoustic cavitation activity was investigated via recording of the integrated sonoluminescence signal in the wavelength range of 220–700 nm in a gel phantom by a cooled charge coupled device (CCD) at different intensities of 1 MHz ultrasound. In order to confirm these results, a chemical dosimetric method was utilized, too. The recorded sonoluminescence signal in the gel phantom containing Au–PpIX was higher than the other phantoms. These records have been confirmed by the chemical dosimetric data. Therefore, we anticipate that a new nanoconjugate composed of Protoporphyrin IX and gold nanoparticles can act as an efficient sonoluminescence agent and could be introduced as a novel sonosensitizer for sonodynamic therapy.  相似文献   

5.
《Ultrasonics sonochemistry》2014,21(3):997-1001
The kinetics of pH-independent hydrolysis of 4-methoxyphenyl dichloroacetate were investigated under ultrasonic irradiation with an application of 10% of the maximum power of the equipment and without sonication in acetonitrile–water binary mixtures with a content of acetonitrile ranging from 0.008 to 35 wt.%. Similar kinetic investigations were performed at intensities corresponding to 10%, 20%, 30%, 40%, and 50% of the input energy in solvent mixtures containing 10 wt.% and 25 wt.% acetonitrile. In parallel, the responses of KI and terephthalic acid dosimeters at applied irradiation levels were registered under the same experimental conditions. Significant kinetic sonication effects were found at sound intensities presumably not inducing cavitation in the solution. This result provides an experimental evidence of kinetic effects of ultrasound in the absence of cavitation. A disturbing impact of cavitation on the ultrasonic acceleration of the reaction was found. The implications of these findings were discussed.  相似文献   

6.
This paper describes the ultrasound assisted dispersal of a low wt./vol.% copper nanopowder mixture and determines the optimum conditions for de-agglomeration. A commercially available powder was added to propan-2-ol and dispersed using a magnetic stirrer, a high frequency 850 kHz ultrasonic cell, a standard 40 kHz bath and a 20 kHz ultrasonic probe. The particle size of the powder was characterized using dynamic light scattering (DLS). Z-Average diameters (mean cluster size based on the intensity of scattered light) and intensity, volume and number size distributions were monitored as a function of time and energy input. Low frequency ultrasound was found to be more effective than high frequency ultrasound at de-agglomerating the powder and dispersion with a 20 kHz ultrasonic probe was found to be very effective at breaking apart large agglomerates containing weakly bound clusters of nanoparticles. In general, the breakage of nanoclusters was found to be a factor of ultrasonic intensity, the higher the intensity the greater the de-agglomeration and typically micron sized clusters were reduced to sub 100 nm particles in less than 30 min using optimum conditions. However, there came a point at which the forces generated by ultrasonic cavitation were either insufficient to overcome the cohesive bonds between smaller aggregates or at very high intensities decoupling between the tip and solution occurred. Absorption spectroscopy indicated a copper core structure with a thin oxide shell and the catalytic performance of this dispersion was demonstrated by drop coating onto substrates and subsequent electroless copper metallization. This relatively inexpensive catalytic suspension has the potential to replace precious metal based colloids used in electronics manufacturing.  相似文献   

7.
The present study demonstrated the enhanced hydroxyl (OH) radical generation by combined use of dual-frequency (0.5 MHz and 1 MHz) ultrasound (US) and titanium dioxide (TiO2) nanoparticles (NPs) as sonocatalyst. The OH radical generation became the maximum, when 0.5 MHz US was irradiated at an intensity of 0.8 W/cm2 and 1 MHz US was irradiated at intensities at 0.4 W/cm2 in the presence of TiO2 NPs under the examined conditions. After incorporation of TiO2 NPs modified with targeting protein pre-S1/S2, HepG2 cancer cells were subjected to the dual-frequency US at optimum irradiation intensities (“targeted-TiO2/dual-US treatment”). Growth of the HepG2 cells was reduced by 46% compared with the control condition after irradiation of dual-frequency US for 60 s with TiO2 NPs incorporation. In contrast, HepG2 cell growth was almost the same as that in the control condition when cells were irradiated with either 0.5 MHz or 1 MHz ultrasound alone without TiO2 NP incorporation.  相似文献   

8.
Scaled-up and economically viable sonochemical systems are critical for increased use of ultrasound in environmental and chemical processing applications. In this study, computational simulations and acoustic pressure maps were used to design a larger-scale sono-reactor containing a multi-stepped ultrasonic horn. Simulations in COMSOL Multiphysics showed ultrasonic waves emitted from the horn neck and tip, generating multiple regions of high acoustic pressure. The volume of these regions surrounding the horn neck were larger compared with those below the horn tip. The simulated acoustic field was verified by acoustic pressure contour maps generated from hydrophone measurements in a plexiglass box filled with water. These acoustic pressure contour maps revealed an asymmetric and discrete distribution of acoustic pressure due to acoustic cavitation, wave interaction, and water movement by ultrasonic irradiation. The acoustic pressure contour maps were consistent with simulation results in terms of the effective scale of cavitation zones (∼10 cm and <5 cm above and below horn tip, respectively). With the mapped acoustic field and identified cavitation location, a cylindrically-shaped sono-reactor with a conical bottom was designed to evaluate the treatment capacity (∼5 L) for the multi-stepped horn using COMSOL simulations. In this study, verification of simulation results with experiments demonstrates that coupling of COMSOL simulations with hydrophone measurements is a simple, effective and reliable scientific method to evaluate reactor designs of ultrasonic systems.  相似文献   

9.
In cancer hyperthermia, ultrasound is considered as an appropriate source of energy to achieve desired therapeutic levels of heating. It is assumed that such a heating is targeted to cancer cells by using nanoparticles as sonosensitization agents. Here, we report the sonosensitizing effects of Nano-Graphene Oxide (NGO) and compare them with gold nanoparticles (AuNPs), Iron Oxide nanoparticles (IONPs).Experiments were conducted to explore the effects of nanoparticle type and concentration, as well as ultrasound power, on transient heating up of the solutions exposed by 1 MHz ultrasound. Nanoparticles concentration was selected from 0.25 to 2.5 mg/ml and the solutions were exposed by ultrasound powers from 1 to 8 W. Real time temperature monitoring was done by a thermocouple and obtained data was analyzed.Temperature profiles of various nanoparticle solutions showed the higher heating rates, in comparison to water. Heating rise was strongly depended on nanoparticles concentration and ultrasound power. AuNPs showed a superior efficiency in heat generation enhancement in comparison to IONPs and NGO.Our result supports the idea of sonosensitizing capabilities of AuNPs, IONPs, and NGO. Targeted hyperthermia may be achievable by preferential loading of tumor with nanoparticles and subsequent ultrasound irradiation.  相似文献   

10.
It is well known that acoustic cavitation can facilitate the inward transport of genetic materials across cell membranes (sonoporation). However, partially due to the unstationary behavior of the initiation and leveling of cavitation, the sonoporation effect is usually unstable, especially in low intensity conditions. A system which is able to regulate the cavitation level during sonication by modulating the applied acoustic intensity with a feedback loop is implemented and its effect on in vitro gene transfection is tested. The regulated system provided better time stability and reproducibility of the cavitation levels than the unregulated conditions. Cultured hepatoma cells (BNL) mixed with 10 μg luciferase plasmids are exposed to 1-MHz pulsed ultrasound with or without cavitation regulation, and the gene transfection efficiency and cell viability are subsequently assessed. Experimental results show that for all exposure intensities (low, medium, and high), stable and intensity dependent, although not higher, gene expression could be achieved in the regulated cavitation system than the unregulated conditions. The cavitation regulation system provides a better control of cavitation and its bioeffect which are crucial important for clinical applications of ultrasound-mediated gene transfection.  相似文献   

11.
The ultrasonic formation of stable emulsions of a bioactive material, black seed oil, in skim milk was investigated. The incorporation of 7% of black seed oil in pasteurised homogenized skim milk (PHSM) using 20 kHz high intensity ultrasound was successfully achieved. The effect of sonication time and acoustic power on the emulsion stability was studied. A minimum process time of 8 min at an applied acoustic power of 100 W was sufficient to produce emulsion droplets stable for at least 8 days upon storage at 4 ± 2 °C, which was confirmed through creaming stability, particle size, rheology and color analysis. Partially denatured whey proteins may provide stability to the emulsion droplets and in addition to the cavitation effects of ultrasound are responsible for the production of smaller sized emulsion droplets.  相似文献   

12.
Performance and efficiency of numerous cavitation enhanced applications in a wide range of areas depend on the cavitation bubble size distribution. Therefore, cavitation bubble size estimation would be beneficial for biological and industrial applications that rely on cavitation. In this study, an acoustic method using a wide beam with low pressure is proposed to acquire the time intensity curve of the dissolution process for the cavitation bubble population and then determine the bubble size distribution. Dissolution of the cavitation bubbles in saline and in phase-shift nanodroplet emulsion diluted with undegassed or degassed saline was obtained to quantify the effects of pulse duration (PD) and acoustic power (AP) or peak negative pressure (PNP) of focused ultrasound on the size distribution of induced cavitation bubbles. It was found that an increase of PD will induce large bubbles while AP had only a little effect on the mean bubble size in saline. It was also recognized that longer PD and higher PNP increases the proportions of large and small bubbles, respectively, in suspensions of phase-shift nanodroplet emulsions. Moreover, degassing of the suspension tended to bring about smaller mean bubble size than the undegassed suspension. In addition, condensation of cavitation bubble produced in diluted suspension of phase-shift nanodroplet emulsion was involved in the calculation to discuss the effect of bubble condensation in the bubble size estimation in acoustic droplet vaporization. It was shown that calculation without considering the condensation might underestimate the mean bubble size and the calculation with considering the condensation might have more influence over the size distribution of small bubbles, but less effect on that of large bubbles. Without or with considering bubble condensation, the accessible minimum bubble radius was 0.4 or 1.7 μm and the step size was 0.3 μm. This acoustic technique provides an approach to estimate the size distribution of cavitation bubble population in opaque media and might be a promising tool for applications where it is desirable to tune the ultrasound parameters to control the size distribution of cavitation bubbles.  相似文献   

13.
The commonly used ultrasonic horn generates localized cavitation below its converging tip resulting in a dense bubble cloud near the tip and limiting diffusion of reactive components into the bubble cloud or reactive radicals out of the bubble cloud. To improve contact between reactive components, a novel ultrasonic horn design was developed based on the principles of the dynamic wave equation. The horn, driven at 20 kHz, has a multi-stepped design with a cone-shaped tip increasing the energy-emitting surface areas and creating multiple reactive zones. Through different physical and chemical experiments, performance of the horn was compared to a typical horn driven at 20 kHz. Hydrophone measurements showed high acoustic pressure areas around the horn neck and tip. Sonochemiluminescence experiments verified multiple cavitation zones consistent with hydrophone readings. Calorimetry and dosimetry results demonstrated a higher energy efficiency (31.3%) and a larger hydroxyl radical formation rate constant (0.36 μM min−1) compared to typical horns. In addition, the new horn degraded naphthalene faster than the typical horn tested. The characterization results demonstrate that the multi-stepped horn configuration has the potential to improve the performance of ultrasound as an advanced oxidation technology by increasing the cavitation zone in the solution.  相似文献   

14.
High intensity low frequency ultrasound was used to process dairy ingredients to improve functional properties. Based on a number of lab-scale experiments, several experimental parameters were optimised for processing large volumes of whey and casein-based dairy systems in pilot scale ultrasonic reactors. A continuous sonication process at 20 kHz capable of delivering up to 4 kW of power with a flow-through reactor design was used to treat dairy ingredients at flow rates ranging from 200 to 6000 mL/min. Dairy ingredients treated by ultrasound included reconstituted whey protein concentrate (WPC), whey protein and milk protein retentates and calcium caseinate. The sonication of solutions with a contact time of less than 1 min and up to 2.4 min led to a significant reduction in the viscosity of materials containing 18% to 54% (w/w) solids. The viscosity of aqueous dairy ingredients treated with ultrasound was reduced by between 6% and 50% depending greatly on the composition, processing history, acoustic power and contact time. A notable improvement in the gel strength of sonicated and heat coagulated dairy systems was also observed. When sonication was combined with a pre-heat treatment of 80 °C for 1 min or 85 °C for 30 s, the heat stability of the dairy ingredients containing whey proteins was significantly improved. The effect of sonication was attributed mainly to physical forces generated through acoustic cavitation as supported by particle size reduction in response to sonication. As a result, the gelling properties and heat stability aspects of sonicated dairy ingredients were maintained after spray drying and reconstitution. Overall, the sonication procedure for processing dairy systems may be used to improve process efficiency, improve throughput and develop value added ingredients with the potential to deliver economical benefits to the dairy industry.  相似文献   

15.
Acoustic cavitation energy distributions were investigated for various frequencies such as 35, 72, 110 and 170 kHz in a large-scale sonoreactor. The energy analyses were conducted in three-dimensions and the highest and most stable cavitation energy distribution was obtained not in 35 kHz but in 72 kHz. However, the half-cavitation-energy distance was larger in the case of 35 kHz ultrasound than in the case of 72 kHz, demonstrating that cavitation energy for one cycle was higher for a lower frequency. This discrepancy was due to the large surface area of the cavitation-energy-meter probe. In addition, 110 and 170 kHz ultrasound showed a very low and poor cavitation energy distribution. Therefore larger input power was required to optimize the use of higher frequency ultrasound in the sonoreactor with long-irradiation distance. The relationship between cavitation energy and sonochemical efficiency using potassium iodide (KI) dosimetry was best fitted quadratically. From 7.77 × 10?10 to 4.42 × 10?9 mol/J of sonochemical efficiency was evaluated for the cavitation energy from 31.76 to 103. 67 W. In addition, the cavitation energy attenuation was estimated under the assumption that cavitation energy measured in this study would be equivalent to sound intensity, resulting in 0.10, 0.18 and 2.44 m?1 of the attenuation coefficient (α) for 35, 72 and 110 kHz, respectively. Furthermore, α/(frequency)2 was not constant, as some previous studies have suggested.  相似文献   

16.
The cavitation microbubbles in dilute gold colloids of different concentrations (2–10 ppm) induced by a focused nanosecond-pulsed laser beam were measured and characterized at different wavelengths by using the passive and active ultrasound measurements. Three colloids with gold nanoparticles (GNPs) of different sizes (10, 45, and 75 nm) were used for experiment. The results show that the lifespan of the microbubble is reduced as the concentration of GNP increases, particularly at the wavelength of 532 nm, the surface plasmon resonance (SPR) of GNP. In contrast, at the off-resonant wavelength (e.g. 700 nm), the lifespan reduction is relatively small. This wavelength-dependent cavitation is attributed to the Faraday–Tyndall effect, a strong light scattering by GNPs. A slight defocusing of the Gaussian beam in gold colloid was proposed. Hence, the waist of the focused beam increases to reduce the optical breakdown in gold colloid. For simplicity, a linear relation between the incremental waist radius of Gaussian beam and the concentration of GNP was assumed. According to this formulation, the theoretical results are consistent with the experimental ones. In addition, the dynamics of the microbubble in gold colloid measured by the active ultrasound method agree with the Rayleigh–Plesset model.  相似文献   

17.
We here suggest a novel and straightforward approach for liter-scale ultrasound particle manipulation standing wave systems to guide system design in terms of frequency and acoustic power for operating in either cavitation or non-cavitation regimes for ultrasound standing wave systems, using the sonochemiluminescent chemical luminol. We show that this method offers a simple way of in situ determination of the cavitation threshold for selected separation vessel geometry. Since the pressure field is system specific the cavitation threshold is system specific (for the threshold parameter range). In this study we discuss cavitation effects and also measure one implication of cavitation for the application of milk fat separation, the degree of milk fat lipid oxidation by headspace volatile measurements. For the evaluated vessel, 2 MHz as opposed to 1 MHz operation enabled operation in non-cavitation or low cavitation conditions as measured by the luminol intensity threshold method. In all cases the lipid oxidation derived volatiles were below the human sensory detection level. Ultrasound treatment did not significantly influence the oxidative changes in milk for either 1 MHz (dose of 46 kJ/L and 464 kJ/L) or 2 MHz (dose of 37 kJ/L and 373 kJ/L) operation.  相似文献   

18.
A comparison between the temperatures within imploding acoustic cavitation bubbles and the extent of sonoluminescence (SL) quenching by C1–C5 aliphatic alcohols in 1-ethyl-3-methylimidazolium ethylsulfate ([EMIM][EtSO4], a well known imidazolium based room temperature ionic liquid (RTIL)), has been made at an ultrasound frequency of 213 kHz. The temperatures obtained ranged from 3500 ± 200 K, in neat [EMIM][EtSO4], to about 3200 ± 200 K in RTIL-alcohol containing solutions. It was also found that the SL intensity decreased with increasing concentration (up to 1 M) of the alcohols to a greater extent compared with the relative changes to the bubble temperatures. Both the extent of the reduction in the bubble temperatures and the SL quenching were much smaller than those obtained in comparable aqueous solutions containing aliphatic alcohols. Possible reasons for the differences in the observed trends between water/alcohol and [EMIM][EtSO4]/alcohol systems under sonication at 213 kHz are discussed.  相似文献   

19.
An acoustic radiation force counterbalanced appliance was employed to map the cavitation distribution in water. The appliance was made up of a focused ultrasound transducer and an aluminum alloy reflector with the exactly same shape. They were centrosymmetry around the focus of the source transducer. Spatial–temporal dynamics of cavitation bubble clouds in the 1.2 MHz ultrasonic field within this appliance were observed in water. And they were mapped by sonochemiluminescence (SCL) recordings and high-speed photography. There were significant differences in spatial distribution and temporal evolution between normal group and counterbalanced group. The reflector could avoid bubble directional displacement induced by acoustic radiation force under certain electric power (⩽50 W). As a result, the SCL intensity in the pre-focal region was larger than that of normal group. In event of high electric power (⩾70 W), most of the bubbles were moving in acoustic streaming. When electric power decreased, bubbles kept stable and showed stripe structure in SCL images. Both stationary bubbles and moving bubbles have been captured, and exhibited analytical potential with respect to bubbles in therapeutic ultrasound.  相似文献   

20.
Lead sulfide (PbS) quantum dots stabilized by 1,2-benzenedimethanethiol can be synthesized by mixing Pb(NO3)2 and Na2S solutions in ethanol under ultrasound irradiation. The PbS quantum dots (2.7 and 3.6 nm in diameter) are characterized by their absorption and fluorescence spectra in the near infrared region and by other surface analytical techniques. With addition of single-walled carbon nanotubes (SWNT) to the system, this ultrasound-assisted procedure allows attachment of PbS nanoparticles to SWNT surface via π–π stacking, thus providing a simple one-pot method for preparation of SWNT–PbS nanoparticle composite materials. Using the ultrasound-assisted method for synthesizing silica composites containing PbS nanoparticles by a sol–gel process is also described.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号