首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Enantioseparations of racemic nonsteroidal anti-inflammatory drugs (naproxen, ibuprofen, ketoprofen, flurbiprofen, suprofen, indoprofen, cicloprofen, and carprofen) were performed by nano-liquid chromatography, employing achiral capillary columns and heptakis(2,3,6-tri-O-methyl)-β-cyclodextrin (TM-β-CD) or hydroxylpropyl-β-cyclodextrin (HP-β-CD) as a chiral mobile phase additive (CMPA). Working under the same experimental conditions (in terms of mobile phase and linear velocity), the performance of a RP-C18 monolithic column was compared with that of a RP-C18 packed column of the same dimensions (100 μm i.d. × 10 cm). Utilizing a mobile phase composed of 30% ACN (v/v) buffered with 50 mM sodium acetate at pH 3, and containing 30 mM TM-β-CD, the monolithic column provided faster analysis but lower resolution than the packed column. This behavior was ascribed to the high permeability of the monolithic column, as well as to its minor selectivity. HP-β-CD was chosen as an alternative to TM-β-CD. Employing the monolithic column, the effects of different parameters such as HP-β-CD concentration, mobile phase composition, and pH on the retention factor and the chiral resolution of the analytes were studied. For the most of the analytes, enantioresolution (which ranged from R s = 1.80 for naproxen to R s = 0.86 for flurbiprofen) was obtained with a mobile phase consisting of sodium acetate buffer (25 mM, pH 3), 10% MeOH, and 15 mM HP-β-CD. When the same experimental conditions were used with the packed column, no compound eluted within 1 h. Upon increasing the percentage of organic modifier to favor analyte elution, only suprofen eluted within 30 min, with an R s value of 1.14 (20% MeOH). Replacing MeOH with ACN resulted in a loss of enantioresolution, except for naproxen (R s = 0.89).  相似文献   

2.
A polydimethylsiloxane (PDMS)-modified monolithic silica column was prepared for performing reversed-phase capillary liquid chromatography. The prepared PDMS column has a permeability of 6.4×10(-14) m(2) with a plate height <9.2 μm. Alkylbenzenes and polycyclic aromatic hydrocarbons (PAHs) were well separated with the PDMS stationary phase, which exhibited similar selectivity and separation mechanism to that of octadecyl stationary phase. The hydrophobic interactions between the analytes and the PDMS stationary phase mainly play the roles for the separation of alkylbenzenes and PAHs. The characteristics of the PDMS column for the separation of alkylbenzenes and PAHs demonstrated that it would be a promising alternative to the octadecyl column.  相似文献   

3.
Surface diffusion phenomena were studied from kinetic and thermodynamic points of view. The existence of a linear free energy relationship between surface diffusion and the retention equilibrium suggests that the mechanism of surface diffusion is the same irrespective of the density of C(1) and C(18) ligands. Surface diffusion coefficient (D(s)) of weakly retained compounds seems to be of the same order of magnitude with corresponding molecular diffusivity. There would be an intimate correlation between surface diffusion and molecular diffusion. The value of D(s) decreases with increasing retention strength. The magnitude of the restriction for surface diffusion is comparable to about one third the enthalpy change due to the sample retention. This means that it is necessary for sample molecules adsorbed to be partially desorbed from the stationary phase surface when they migrate by surface diffusion. The results of this study provide the fundamental information for developing an appropriate model of surface diffusion, which explains some intrinsic characteristics and mechanism of surface diffusion.  相似文献   

4.
Chromatographic properties of a new type of monolithic silica rod columns were examined. Silica rod columns employed for the study were prepared from tetramethoxysilane, modified with octadecylsilyl moieties, and encased in a stainless-steel protective column with two polymer layers between the silica and the stainless-steel tubing. A 25 cm column provided up to 45,000 theoretical plates for aromatic hydrocarbons, or a minimum plate height of about 5.5 μm, at optimum linear velocity of ca. 2.3 mm/s and back pressure of 7.5 MPa in an acetonitrile-water (80/20, v/v) mobile phase at 40°C. The permeability of the column was similar to that of a column packed with 5 μm particles, with K(F) about 2.4×10(-14) m(2) (based on the superficial linear velocity of the mobile phase), while the plate height value equivalent to that of a column packed with 2.5 μm particles. Generation of 80,000-120,000 theoretical plates was feasible with back pressure below 30 MPa by employing two or three 25 cm columns connected in series. The use of the long columns enabled facile generation of large numbers of theoretical plates in comparison with conventional monolithic silica columns or particulate columns. Kinetic plot analysis indicates that the monolithic columns operated at 30 MPa can provide faster separations than a column packed with totally porous 3-μm particles operated at 40 MPa in a range where the number of theoretical plates (N) is greater than 50,000.  相似文献   

5.
Preparation methods of monolithic silica columns for HPLC including the surface modification were reviewed. Chemical modification methods recently reported to obtain stationary phases for reversed-phase (RP), chiral, ion-exchange, and hydrophilic interaction chromatography (HILIC) separations were discussed. Recent results related to preparation methods of monolithic silica were also covered. The characteristics and properties of silica monoliths and some applications of monolithic silica columns for different analytical and bioanalytical fields will be commented.  相似文献   

6.
Summary Members of three homologous series and five non-homologous solutes with various functional groups were chromatographed on a series of well-characterized C18 reversed stationary phases with a range of methanol-water mobile phases. Measured capacity factors of solutes were correlated with the concentration of C18 ligands on the stationary phase. A linear relationship with the slope depending on a solute molecular structure and the volume fraction of methanol in the mobile phase was obtained. A method for the evaluation of phase ratio is also proposed. Presented at the 17th International Symposium on Chromatography, September 25–30, 1988, Vienna, Austria.  相似文献   

7.
An alternate pumping-recycle system utilizing a commercially available low dead-volume switching valve was developed for microcolumn LC. The recycle system had two separation columns, and the dead volume of the recycling lines was kept to a minimum by avoiding passage of the sample through the pump chamber, sample injector, and the normal path length of a conventional UV detector. The drawback of the high total back pressure caused by the second column that is placed after the detector was overcome by on-column detection, and this eliminated the need for a high pressure flow cell. The system was used for the separation of an authentic mixture of benzene, benzene-1,3,5-d3, and benzene-d6. Baseline separation was accomplished after six cycles and the calculated theoretical plate number for benzene was 230,000. It was observed that the theoretical plate number (N) increased linearly with increasing number of cycles, and the N per unit time increased with increasing inlet pressure. The separation conditions were optimized and the separation of benzene and benzene-d6 was accomplished within 75 min at 2.5 MPa inlet pressure.  相似文献   

8.
Single component isotherm data of caffeine and phenol were acquired on two different stationary phases for RPLC, using a methanol/water solution (25%, v/v, methanol) as the mobile phase. The columns were the non-endcapped Waters Resolve-C18, and the Waters XTerra MS C18. Both columns exhibit similar C18 -chain densities (2.45 and 2.50 micromol/m2) and differ essentially by the nature of the underivatized solid support (a conventional, highly polar silica made from water glass, hence containing metal impurities, versus a silica-methylsilane hybrid surface with a lower density of less acidic free silanols). Thirty-two adsorption data points were acquired by FA, for caffeine, between 10(-3) and 24 g/l, a dynamic range of 24,000. Twenty-eigth adsorption data points were acquired for phenol, from 0.025 to 75 g/l, a dynamic range of 3000. The expectation-maximization procedure was used to derive the affinity energy distribution (AED) from the raw FA data points, assuming a local Langmuir isotherm. For caffeine, the AEDs converge to a bimodal and a quadrimodal distribution on XTerra MS-C18 and Resolve-C18, respectively. The values of the saturation capacity (q(s,1) approximately equal to 0.80 mol/l and q(s,2) approximately equal to 0.10 mol/l) and the adsorption constant (b1 approximately equal to 3.11/mol and b2 approximately equal to 29.1 l/mol) measured on the two columns for the lowest two energy modes 1 and 2, are comparable. These data are consistent with those previously measured on an endcapped Kromasil-C18 in a 30/70 (v/v), methanol/water solution (q(s,1) = 0.9 mol/l and q(s,2) = 0.10 mol/l, b1 = 2.4 l/mol and b2 = 16.1 l/mol). The presence of two higher energy modes on the Waters Resolve-C18 column (q(s,3) approximately equal to 0.013 mol/l and q(s,4) approximately equal to 2.6 10(-4) mol/l, b3 approximately equal to 252 l/mol and b4 = 13,200 l/mol) and the strong peak tailing of caffeine are explained by the existence of adsorption sites buried inside the C18-bonded layer. It is demonstrated that strong interactions between caffeine and the water protected bare silica surface cannot explain these high-energy sites because the retention of caffeine on an underivatized Resolve silica column is almost zero. Possible hydrogen-bond interactions between caffeine and the non-protected isolated silanol groups remaining after synthesis amidst the C18-chain network cannot explain these high energy interactions because, then, the smaller phenol molecule should exhibit similarly strong interactions with these isolated silanols on the same Resolve-C18 column and, yet, the consequences of such interactions are not observed. These sites are more consistent with the heterogeneity of the local structure of the C18-bonded layer. Regarding the adsorption of phenol, no matter whether the column is endcapped or not, its molecular interactions with the bare silica were negligible. For both columns, the best adsorption isotherm was the Bilangmuir model (with q(s,1) approximately equal to 2 and q(s,2) approximately equal to 0.67 mol/l, b1 0.61 and b2 approximately equal to 10.3 l/mol). These parameters are consistent with those measured previously on an endcapped Kromasil-C18 column under the same conditions (q(s,1) = 1.5 and q(s,2) = 0.71 mol/l, b1 = 1.4 l/mol and b2 = 11.3 l/mol). As for caffeine, the high-energy sites are definitely located within the C18-bonded layer, not on the bare surface of the adsorbent.  相似文献   

9.
Development and validation of an RP-HPLC method for determination of levetiracetam in pharmaceutical tablets is described. The separation and quantification of levetiracetam and caffeine (internal standard) were performed using a single analytical procedure with two different types of stationary phases, conventional Phenomenex Gemini C18 (100 x 4.6 mm, 5 microm) and Merck Chromolith Performance RP18e (100 x 4.6 mm, macropore size 2 mm, micropore size 13 nm) monolithic silica. Five-microliter aliquots of samples were injected into the system and eluted using water-acetonitrile (90 + 10, v/v) mobile phase pumped at the rate of 1 mL/min. The analyte peaks were detected at 200 nm using a diode array detector with adequate resolution. Validation studies were performed using the method recommended by the International Conference on Harmonization, the U.S. Pharmacopeia, and AOAC INTERNATIONAL, which includes accuracy, precision, range, limits, robustness, and system suitability parameters. Levetiracetam and caffeine were detected in about 7 min using the conventional column, whereas less than 5 min was required when the monolithic column was used. Calibration plots had r values close to unity in the range of 0.8-8.0 microg/mL. Assay of levetiracetam in a tablet formulation was demonstrated as an application to real samples.  相似文献   

10.
A systematic study is reported on the performance of long monolithic capillary columns in gradient mode. Using a commercial nano-LC system, reversed-phase peptide separations obtained through UV-detection were conducted. The chromatographic performance, in terms of conditional peak capacity and peak productivity, was investigated for different gradient times (varying between 90 and 1320min) and different column lengths (0.25, 1, 2 and 4m) all originating from a single 4m long column. Peak capacities reaching values up to n=10(3) were measured in case of the 4m long column demonstrating the high potential of these long monoliths for the analysis of complex biological mixtures, amongst others. In addition, it was found that the different column fragments displayed similar flow resistance as well as consistent chromatographic performance in accordance with chromatographic theory indicating that the chromatographic bed of the original 4m long column possessed a structural homogeneity over its entire length.  相似文献   

11.
Plots of the retention factor against mobile phase composition were used to organize a varied group of solutes into three categories according to their retention mechanism on an octadecylsiloxane-bonded silica stationary phase HyPURITY C18 with methanol-water and acetonitrile-water mobile phase compositions containing 10-70% (v/v) organic solvent. The solutes in category 1 could be fit to a general retention model, Eq. (2), and exhibited normal retention behavior for the full composition range. The solutes in category 2 exhibited normal retention behavior at high organic solvent composition with a discontinuity at low organic solvent compositions. The solutes in category 3 exhibited a pronounced step or plateau in the middle region of the retention plots with a retention mechanism similar to category 1 solutes at mobile phase compositions after the discontinuity and a different retention mechanism before the discontinuity. Selecting solutes and appropriate composition ranges from the three categories where a single retention mechanism was operative allowed modeling of the experimental retention factors using the solvation parameter model. These models were then used to predict retention factors for solutes not included in the models. The overwhelming number of residual values [log k (experimental) - log k (model predicted)] were negative and could be explained by contributions from steric repulsion, defined as the inability of the solute to insert itself fully into the stationary phase because of its bulkiness (i.e., volume and/or shape). Steric repulsion is shown to strongly depend on the mobile phase composition and was more significant for mobile phases with a low volume fraction of organic solvent in general and for mobile phases containing methanol rather than acetonitrile. For mobile phases containing less than about 20 % (v/v) organic solvent the mobile phase was unable to completely wet the stationary phase resulting in a significant change in the phase ratio and for acetonitrile (but less so methanol) changes in the solvation environment indicated by a discontinuity in the system maps.  相似文献   

12.
A novel stationary phase triacontyl-functionalized monolithic silica capillary column was successfully prepared for reversed-phase capillary liquid chromatography. The performance of the monolithic silica capillary column coated with triacontyl chain for the separation of alkylbenzenes, xylene isomers, polycyclic aromatic hydrocarbons, and mixture of α- and β-carotenes was studied, which was compared to that using the monolithic silica capillary column coated with octadecyl chain. The comparison results showed that triacontyl-functionalized monolithic silica capillary column would be a promising media to be used for the separation of isomeric solutes with long chain in reversed-phase capillary liquid chromatography.  相似文献   

13.
The solvation parameter model system constants and retention factors were used to interpret retention properties of 39 calibration compounds on a biphenylsiloxane-bonded stationary phase (Kinetex biphenyl) for acetone-water binary mobile phase systems containing 30–70% v/v. Variation in system constants, phase ratios, and retention factors of acetone-water binary mobile phases systems were compared with more commonly used acetonitrile and methanol mobile phase systems. Retention properties of acetone mobile phases on a Kinetex biphenyl column were more similar to that of acetonitrile than methanol mobile phases except with respect to selectivity equivalency. Importantly, selectivity differences arising between acetone and acetonitrile systems (the lower hydrogen-bond basicity of acetone-water mobile phases and differences in hydrogen-bond acidity, cavity formation and dispersion interactions) could be exploited in reversed-phase liquid chromatography method development on a Kinetex biphenyl stationary phase.  相似文献   

14.
We prepared hybrid particle-monolithic polymethacrylate columns for micro-HPLC by in situ polymerization in fused silica capillaries pre-packed with 3–5 μm C18 and aminopropyl silica bonded particles, using polymerization mixtures based on laurylmethacrylate–ethylene dimethacrylate (co)polymers for the reversed-phase (RP) mode and [2-(methacryloyloxy)ethyl]-dimethyl-(3-sulfopropyl) zwitterionic (co)polymers for the hydrophilic interaction (HILIC) mode. The hybrid particle-monolithic columns showed reduced porosity and hold-up volumes, approximately 2–2.5 times lower in comparison to the pure monolithic columns prepared in the whole volume of empty capillaries. The elution volumes of sample compounds are also generally lower in comparison to packed or pure monolithic columns. The efficiency and permeability of the hybrid columns are intermediate in between the properties of the reference pure monolithic and particle-packed columns. The chemistries of the embedded solid particles and of the interparticle monolithic moiety in the hybrid capillary columns contribute to the retention to various degrees, affecting the selectivity of separation. Some hybrid columns provided improved separations of proteins in comparison to the reference particle-packed columns in the reversed-phase mode. Zwitterionic hybrid particle-monolithic columns show dual mode retention HILIC/RP behaviour depending on the composition of the mobile phase and allow separations of polar compounds such as phenolic acids in the HILIC mode at lower concentrations of acetonitrile and, often in shorter analysis time in comparison to particle-packed and full-volume monolithic columns.  相似文献   

15.
Jinno  K.  Nakamura  H. 《Chromatographia》1994,39(5-6):285-293
Summary Fluorinated bonded silica has been evaluated as a packing material in reversed-phase liquid chromatography (RPLC) with polycyclic aromatic hydrocarbons, chlorinated benzenes and substituted benzenes as sample probes. The bonded material is useful as a reversed-phase stationary phase and for polar compounds it offers a specific selectivity not found with octadecylsilica (ODS) phases. The phase also retains non-planar compounds more than planar molecules. The results can be explained by conformational differences between ODS and the fluorinated bonded phase by MM2 calculation.  相似文献   

16.
In this study, a RP-HPLC method for the analysis of polyacetylenes and polyenes in Echinacea pallida roots and phytopharmaceuticals was developed. The reference compounds used for quantification were isolated from the plant material and their structures were determined on the basis of the analysis of UV, IR, NMR and MS data. The complete structure elucidation of three compounds, namely 8-hydroxy-tetradec-(9E)-ene-11,13-diyn-2-one (1), tetradec-(8Z)-ene-11,13-diyn-2-one (6) and pentadec-(8Z)-en-2-one (9) is described. In the analysis of the n-hexane extracts of E. pallida roots, the comparison between conventional and monolithic columns showed that the elution order in both cases is identical and the selectivity is equivalent. However, the retention times achieved by the monolithic column are shorter, resulting in a faster separation (20 min). Therefore, the analyses were carried out on a Chromolith Performance RP-18e (100 mm x 4.6 mm i.d.), with a gradient mobile phase composed by H(2)O and ACN at the flow rate of 2 mL/min. The column was thermostatted at 20 degrees C. The photodiode array detector monitored the eluent at 210 nm. The validation procedure confirmed that this technique affords reliable analysis of these components and is appropriate for the quality control of complex matrices, such as E. pallida roots and phytopharmaceuticals.  相似文献   

17.
Butyl-methacrylate-based porous monoliths were prepared inside fused-silica capillaries as reversed-phase separation media for liquid chromatography (LC) and capillary electrochromatography (CEC). During our previous research on methacrylate-based monoliths for reversed-phase separations, we noticed that a separation efficiency of up to 300,000 plates/m can easily be obtained in the CEC mode for unretained compounds. However, the efficiencies for retained compounds were much lower in reversed-phase systems, especially in pressure-driven LC. In this work methacrylate-based columns were prepared and characterized in terms of efficiency and retention in reversed-phase (pressure-driven) LC and in CEC. Much attention has been paid to the mass-transfer mechanism in the stationary phase. Factors that affect the plate heights for specific compounds have been investigated. A possible explanation for the relatively low separation efficiency of retained compounds and suggestions to improve molecular mass transfer are provided.  相似文献   

18.
19.
A silica monolithic capillary column was linked to an open capillary of the same internal diameter via a Teflon sleeve to form a duplex column to investigate the combination of chromatography and electrophoresis in the mode of electrically assisted capillary liquid chromatography (eCLC). Using a commercial CE instrument with an 8.5 cm long, 100 μm i.d. reversed phase silica monolithic section and a window 1.5 cm beyond the end of this in a 21.5 cm open section, a minimum plate height of 9 μm was obtained in capillary liquid chromatography (CLC) mode at a low driving pressure of 50 psi. In eCLC mode, high speed and high resolution separations of acidic and basic compounds were achieved with selectivity tuning based on the flexible combination of pressure (0–100 psi) and voltage. Taking advantage of the excellent permeability of silica monolithic columns, use of a step flow gradient enabled elution of compounds with different charge state.  相似文献   

20.
Influence of column temperature and mobile phase composition (phi) on surface diffusion was studied in reversed-phase liquid chromatography using a C(18)-silica gel column and methanol-water mixtures. The temperature dependence of surface diffusion coefficient (D(s)) was explained by considering that of the molecular diffusivity, suggesting the presence of a kind of correlation between surface and molecular diffusions. The influence of phi on D(s) was accounted for by considering the restriction energy (E(r)) for surface diffusion. Physical meanings of the linear correlation between E(r) and the enthalpy change due to sample retention are discussed in connection with the mechanism of surface diffusion.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号