首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 218 毫秒
1.
双重净化-气相色谱法测定植物油中指示性多氯联苯   总被引:2,自引:0,他引:2  
丁立平  蔡春平  王丹红 《色谱》2014,32(11):1266-1270
为了考察食用油中7种指示性多氯联苯(PCBs)的残留情况,建立了食用油中痕量多氯联苯测定的双重净化-气相色谱法。以乙腈提取样品,提取液浓缩至干后用正己烷溶解,经浓硫酸、硅胶分散固相萃取双重净化后进行气相色谱分析,外标法定量。优化的色谱条件为:HP-5石英毛细管柱(30 m×0.32 mm×0.25 μm)程序升温分离,流速0.8 mL/min,进样量1.00 μL,电子捕获检测器检测。结果表明:在优化的条件下,7种多氯联苯在10~500 μg/L范围内线性良好,相关系数大于0.999,不同基质中的检出限(S/N=3)范围为1.8~8.9 μg/kg,定量限(S/N=10)范围为5.9~29.8 μg/kg。在橄榄油、花生油和棕榈油空白样品中添加10、20、100 μg/kg 3个水平的7种多氯联苯,其加标回收率范围为71.0%~105.5%,相对标准偏差(RSD)范围为4.0%~11.3%。该方法具有操作简便、快速、准确的特点,可用于植物油中指示性多氯联苯残留量的日常检测。  相似文献   

2.
张贵江  臧晓欢  周欣  王璐  王春  王志 《色谱》2013,31(11):1071-1075
将磁性石墨烯作为磁性固相萃取的吸附剂与气相色谱-质谱(GC-MS)相结合建立了环境水样中7种三嗪类除草剂残留的测定新方法。对影响萃取效率的一些因素如吸附剂用量、萃取时间、样品溶液的pH值、离子强度和解吸条件等进行了优化。在优化的实验条件下,7种三嗪类除草剂的富集倍数在574~968之间。测定西玛津、扑灭津、嗪草酮、西草净、氰草津的线性范围为0.01~10.0 μg/L,莠去津的线性范围为0.05~10.0 μg/L,扑灭净的线性范围为0.01~8.0 μg/L。线性相关系数为0.9968~0.9998,检出限(S/N=3)为1.0~5.0 ng/L。将本方法应用于井水、自来水和湖水等实际水样的分析,在0.5 μg/L和2.0 μg/L下的加标回收率为79.8%~118.3%,相对标准偏差为3.6%~10.5%。该法操作简单、富集倍数高,可满足水样中三嗪类除草剂残留的检测要求。  相似文献   

3.
木合他拜尔  严华  徐姗  冯楠  郝杰  朱尘琪  郭爽  张朝晖  韩南银 《色谱》2015,33(11):1199-1204
建立了鸡肉中二硝托胺、尼卡巴嗪、地克珠利、妥曲珠利、莫能菌素及盐霉素6种抗球虫药物的超高效液相色谱-高分辨串联质谱多残留检测方法。经QuEChERS样品净化,首先使用含有1%(v/v)三氯乙酸的乙腈-水(3 : 7, v/v)溶液提取样品中的被测物,再加入氯化钠,使用50 mg/mL N-丙基乙二胺(PSA)+50 mg/mL中性氧化铝(Alumina-N)的混合分散固相萃取(dispersive solid phase extraction, DSPE)粉末净化提取,过0.22 μ m滤膜后以超高效液相色谱-高分辨串联质谱检测。选择Waters Acquity UPLC® BEH C8色谱柱(100 mm×2.1 mm, 1.7 μ m),以甲醇-5 mmol/L醋酸铵水溶液为流动相进行梯度洗脱。使用正、负离子同时扫描模式,基质外标法定量。研究表明,6种目标化合物的线性范围为:二硝托胺,1.0~30.0 μ g/L;尼卡巴嗪,0.2~6.0 μ g/L;地克珠利、妥曲珠利,2.0~60.0 μ g/L;莫能菌素、盐霉素,4.0~120.0 μ g/L。空白样品中添加低、中、高3个水平的混合标准溶液,回收率在67.7%~126.8%之间,相对标准偏差(RSD)≤10.4%。6种抗球虫药物的定量限分别为:二硝托胺,2.50 μ g/kg;尼卡巴嗪,0.50 μ g/kg;地克珠利、妥曲珠利,5.00 μ g/kg;莫能菌素、盐霉素,20.00 μ g/kg。该方法操作简便,灵敏度高,且能够满足日常检测要求。  相似文献   

4.
在系统优化固相萃取吸附剂填料类型、洗脱溶剂种类及体积的基础上,建立了蔬菜和水果中193种农药残留的气相色谱-质谱(GC-MS)检测方法。样品经乙腈均质提取,C18/PSA固相萃取柱净化,乙腈洗脱,GC-MS选择离子监测(SIM)模式检测,以磷酸三苯酯内标法定量。结果表明,130种农药在10~1000 μg/L、34种农药在20~1000 μg/L、26种农药在50~1000 μg/L、3种农药在100~1000 μg/L范围内线性关系良好,相关系数为0.9967~1.0000,方法检出限(以信噪比为3计)为0.04~8.26 μg/kg,添加回收率为71.6%~117.9%,相对标准偏差为3.0%~11.8%。该方法样品处理简单快速,相比其他多残留分析方法净化效果好,其灵敏度和选择性明显提高,适用于日常检测工作。  相似文献   

5.
宋爱英  杨晶 《色谱》2018,36(8):803-808
建立了电场促进下的单滴微萃取结合气相色谱技术测定尿中6种苯丙胺类兴奋剂(ATSs)的分析方法。通过对影响萃取效率因素的优化,确定了最佳萃取条件:二氯甲烷萃取溶剂2 μL、萃取时间3 min、样品溶液pH 7和电压-2.5 V。采用HP-5毛细管色谱柱(30 m×0.32 mm×0.25 μm)进行分离,用氢火焰离子化检测器进行检测。6种ATSs在20~1000 μg/L范围内呈良好的线性关系,相关系数(r)为0.989~0.997,检出限(S/N=3)为3.2~7.6 μg/L;对尿样进行加标回收试验(50、100和500 μg/L),6种ATSs的回收率为91.6%~111.2%,相对标准偏差为2.9%~6.2%(n=3)。该法具有快速简便、灵敏度高、重复性好、线性范围宽、对环境友好的特点,可用于尿样中6种ATSs的分析测定。  相似文献   

6.
基于磁性C_(12)烷基壳聚糖硅胶复合材料,建立了磁固相萃取-高效液相色谱法测定茶饮样品中5种双酚类化合物(BPs)的分析方法。研究表明,磁性C_(12)烷基壳聚糖硅胶复合材料对这5种BPs都具有很好的富集能力,富集率在96%~98%之间。采用2 mL乙腈在5 min内就可将富集的双酚化合物快速、完全洗脱。建立的BPs分析方法线性关系良好(R0.99),5种目标物的检出限范围为2.34~15.6μg/L,方法的精密度(RSDs,n=7)在1.5%~8.5%之间,加标回收率范围为86.0%~112.3%。方法可用于茶饮品中BPs的检测。  相似文献   

7.
达晶  王钢力  曹进  张庆生 《色谱》2015,33(8):830-837
基于欧洲标准化委员会标准方法(EN 15662)对食品基质的分类,选择6种代表性植物性食品作为基质,系统优化了QuEChERS样品前处理方法;在此基础上,建立了30种氨基甲酸酯类农药的液相色谱-串联质谱分析方法。实验结果表明,除涕灭威砜的线性范围为2~100 μg/kg,其他29种氨基甲酸酯类农药的线性范围均为1~100 μg/kg;6种样品基质在3个添加水平(5、20、100 μg/kg)下的回收率为56.13%~127.6%,相对标准偏差为0.47%~16%;以信噪比(S/N)≥10计,30种农药的定量限(LOQ)为0.041~1.9 μg/kg。本文方法灵敏、有效,适用于植物性食品基质中30种氨基甲酸酯类农药残留的测定。  相似文献   

8.
李玮  艾连峰  郭春海  马育松  窦彩云 《色谱》2013,31(10):946-953
建立了液相色谱-串联质谱法同时测定牛奶和奶粉中4种青霉素(青霉素G、青霉素V、阿莫西林、氨苄西林)及其4种 β-内酰胺酶酶解产物(青霉素G脱羧噻唑酸、青霉素V脱羧噻唑酸、阿莫西林脱羧噻唑酸、氨苄西林脱羧噻唑酸)残留的方法。样品采用乙腈-水提取,浓缩后经HLB柱净化,用液相色谱-串联质谱检测,外标法定量。结果表明,青霉素原药在4~200 μg/L,酶解产物在10~500 μg/L范围呈良好线性,线性相关系数均大于0.99;样品检出限为5~50 μg/kg(S/N≥3),定量限为8~100 μg/kg(S/N≥10);对牛奶和奶粉样品分别进行3个水平的加标回收实验(n=6),牛奶中青霉素及其酶解产物的平均回收率为83.48%~96.97%,相对标准偏差为3.86%~10.87%;奶粉中青霉素及其酶解产物的平均回收率为82.70%~95.14%,相对标准偏差为3.02%~9.81%。该方法稳定、可靠,适用于牛奶和奶粉中青霉素类药物及其酶解代谢产物的测定。  相似文献   

9.
张续  邱天  付慧  杨艳伟  赵峰  林少彬  胡小键 《色谱》2018,36(9):895-903
建立了人尿中9种邻苯二甲酸酯(PAE)代谢物的超高效液相色谱-三重四极杆质谱(UPLC-MS/MS)测定方法。2 mL尿液样本酶解2 h后,经强阴离子固相萃取净化处理;选用Waters ACQUITY UPLC BEH Phenyl色谱柱(100 mm×2.1 mm,1.7 μ m),以0.1%(体积分数)乙酸乙腈和0.1%(体积分数)乙酸水溶液为流动相进行梯度洗脱;在负离子电喷雾多反应监测模式(MRM)下测定9种PAE代谢物含量。8种PAE代谢物在0.39~200 μ g/L范围内、1种PAE代谢物在1.17~600 μ g/L范围内线性关系良好,相关系数均大于0.995。方法检出限为0.06~0.85 μ g/L,定量限为0.20~2.80 μ g/L。3个加标水平的加标回收率为84.1%~122%,精密度为4.5%~14.3%;日内精密度不高于9.3%,日间精密度不高于10.1%;基质效应和稳定性符合分析要求。应用该方法测定50份人尿液样本,邻苯二甲酸单环已酯(MCHP)和邻苯二甲酸单苄酯(MBZP)的检出率分别为0和44.0%,其余7种PAE代谢物的检出率为100%。该方法操作简单、定量准确、稳定性好,适用于人尿中9种PAE代谢物的定量分析。  相似文献   

10.
叶曦雯  彭燕  牛增元  高永刚  罗忻  邹立 《色谱》2015,33(4):377-382
建立了超高效液相色谱-线性离子阱/静电场轨道阱高分辨质谱(UPLC-LTQ/Orbitrap MS)同时测定纺织品中24种游离态致癌芳香胺的方法。样品经二氯甲烷超声提取并稀释后,用ZORBAX SB-C18色谱柱(150 mm×2.1 mm, 5 μm)分离,以0.1%甲酸水溶液和甲醇为流动相,电喷雾正离子(ESI+)模式电离,以准分子离子峰的精确质量数和保留时间定性,以提取的色谱图峰面积定量。在0.5~500 μg/L范围内,24种芳香胺的线性相关系数(R2) 大于0.99,样品加标回收率为87.8%~105.6%,相对标准偏差为1.6%~3.4%。方法检出限为0.5~1 μg/kg。应用本方法检测山东地区进出口含氨纶纺织品样品14个,在5个样品中检出游离态芳香胺4,4'-二氨基二苯甲烷,含量范围为0.21~25.6 mg/kg。  相似文献   

11.
潘胜东  何仟  陈晓红  王立  邱巧丽  金米聪 《色谱》2017,35(9):980-986
建立了固相萃取-超高效液相色谱-高分辨质谱(SPE-UPLC-HRMS)快速测定食用油中4种痕量酚类环境雌激素(双酚S(BPS)、双酚F(BPF)、双酚A(BPA)和4-壬基酚(4-NP))的分析方法。食用油样品经乙腈涡旋提取和SLC玻璃固相萃取小柱净化后,以0.05%(v/v)三乙醇胺和甲醇溶液为流动相进行梯度洗脱,采用Waters ACQUITY UPLC HSS T3色谱柱(100 mm×2.1 mm,1.8μm)进行分离,在电喷雾离子源负离子模式(ESI-)和选择性离子监测(SIM)模式下进行检测,内标法定量。4种目标物在各自的范围内有良好的线性关系,相关系数(r)0.999。方法的检出限(LOD,S/N=3)和定量限(LOD,S/N=10)分别为0.03~0.11μg/kg和0.10~0.36μg/kg。在1.0、10.0和80.0μg/kg 3个加标水平下,4种目标物的加标回收率为86.3%~96.1%,相对标准偏差(RSD)为2.2%~8.8%(n=6)。基质效应实验表明方法在低、中、高3个浓度水平下均无明显的基质干扰。该法简便、快速,能用于食用油中双酚S、双酚F、双酚A和4-壬基酚残留的快速检测。  相似文献   

12.
采用简单高温煅烧法成功制备了磁性钴镍基氮掺杂三维碳纳米管与石墨烯复合材料(CoNi@NGC),将其作为吸附剂用于水体中6种双酚类化合物(BPs)的吸附性能和机理研究。将CoNi@NGC复合纳米材料用作萃取介质,运用酸碱泡腾片的CO2强力分散作用,开发了泡腾反应强化的分散固相微萃取前处理方法,结合高效液相色谱-荧光检测(HPLC-FLD)快速定量饮料中痕量BPs。采用扫描电镜、透射电镜、傅里叶红外光谱、氮气吸脱附、X射线光电子能谱和磁滞回线等技术手段对材料形貌结构进行表征,结果显示:该吸附剂成功实现氮元素的掺杂,且具有较大的比表面积(109.42 m2/g)、丰富的孔径及较强的磁性(17.98 emu/g)。吸附剂投加量、pH、温度、时间等因子优化试验表明:当pH=7,在初始质量浓度为5 mg/L的BPs混合溶液中投加5 mg CoNi@NGC, 298 K反应5 min,对双酚M(BPM)、双酚A(BPA)的吸附率分别高达99.01%和98.21%。作用90 min时对双酚Z(BPZ)、BPA、BPM的吸附率近100%。在吸附过程中,BPs与CoNi@NGC之间的整个吸附过程主要受氢键、静电作用和π-π共轭作用共同控制。整个吸附过程符合Freundlich吸附等温线模型和准二级动力学方程,吸附自发进行。进一步将CoNi@NGC作为萃取介质制备成磁性泡腾片,利用泡腾分散微萃取技术高效富集和提取6种盒装饮料中的BPs,优化了影响富集效果的泡腾片的存在与否、洗脱剂种类、洗脱时间、洗脱体积等关键因子,在最佳萃取条件下(pH=7,投加5 mg CoNi@NGC, 2 mL丙酮洗脱6 min),结合HPLC-FLD,新开发的泡腾分散微萃取方法提供的检出限为0.06~0.20 μg/L,定量限为0.20~0.66 μg/L,日内和日间精密度分别为1.44%~4.76%和1.69%~5.36%,在实际样品中不同水平下的加标回收率为82.4%~103.7%,在桃汁中检测到BPA和双酚B(BPB)分别为2.09 μg/L和1.37 μg/L。再生试验表明该吸附材料至少可以重复使用5次以上,显著降低了分析的试验成本。与其他方法相比,该方法具有灵敏度高、萃取速度快、环境友好等优点,在常规食品污染监测中具有较强的应用价值。  相似文献   

13.
The bisphenol A (BPA) imprinted polymer microspheres were prepared by simple Pickering emulsion polymerization. Compared to traditional bulk polymerization, both high yields of polymer and good control of particle sizes were achieved. The characterization results of scanning electron microscopy and nitrogen adsorption–desorption measurements showed that the obtained molecularly imprinted polymer microsphere (MIPMS) particles possessed regular spherical shape, narrow diameter distribution (30–60 μm), a specific surface area (SBET) of 281.26 m2 g−1 and a total pore volume (Vt) of 0.459 cm3 g−1. Good specific adsorption capacity for BPA was obtained in the sorption experiment and good class selectivity for BPA and its seven structural analogs (bisphenol F, bisphenol B, bisphenol E, bisphenol AF, bisphenol S, bisphenol AP and bisphenol Z) was demonstrated by the chromatographic evaluation experiment. The MIPMS as solid-phase extraction (SPE) packing material was then evaluated for extraction and clean-up of these bisphenols (BPs) from human urine samples. An accurate and sensitive analytical method based on the MIPMS-SPE coupled with HPLC-DAD has been successfully established for simultaneous determination of eight BPs from human urine samples with detection limits of 1.2–2.2 ng mL−1. The recoveries of BPs for urine samples at two spiking levels (100 and 500 ng mL−1 for each BP) were in the range of 81.3–106.7% with RSD values below 8.3%.  相似文献   

14.
刘洪媛  金静  郭崔崔  陈吉平  胡春 《色谱》2021,39(8):835-844
双酚类化合物作为一类内分泌干扰物广泛存在于环境介质中,经过多种途径迁移至人体后,可对人体产生内分泌毒性、细胞毒性、基因毒性、生殖毒性、二噁英毒性和神经毒性,已被加拿大政府风险评估识别为进一步优先控制名录。随着环境领域对双酚类化合物的广泛关注,相关研究工作逐渐向水、沉积物、灰尘和生物样品等多介质开拓。但是,由于不同环境样品在基质复杂性和污染物浓度水平等方面存在显著差异,开发提取效率高、净化选择性好、普适性强、操作简单、高通量的提取和净化方法,有助于实现环境介质中双酚类化合物的高灵敏、批量检测。近年来,新型前处理技术发展迅速,尤其是固相萃取技术,在双酚类化合物提取与净化方面取得了长足的发展,不仅在一定程度上克服了传统提取净化方法存在的耗时、耗力和耗溶剂等不足,而且为新型污染物分析提供了更多的技术支持。该文简述了典型双酚类化合物的理化性质、用途用量和环境危害,重点围绕新型固相萃取吸附剂开发和固相萃取模式转变两个方面,总结了固相萃取在双酚类化合物提取净化方法方面取得的进展。商品化固相萃取产品普适性强,在环境监测领域应用范围较广,适用于双酚类化合物的产品种类有限;新型吸附剂研发聚焦吸附容量(如介孔硅材料、碳纳米材料、金属-有机框架材料、环糊精)和选择性(如分子印迹聚合物和混合模式离子交换聚合物)两个方面,种类多样化可满足不同检测需求;越来越多的高灵敏分析仪器不断推向市场,为适应新的发展形势,固相萃取模式正逐渐向微型化、自动化、简易化等方向发展,如QuEChERS、固相微萃取、磁固相萃取等。  相似文献   

15.
丘秀珍  郭会时  陈步青 《色谱》2013,31(8):809-812
建立了固相萃取-微乳液相色谱法同时测定环境水体中的苯酚、双酚A (BPA)、2,4-二氯苯酚3种酚类化合物的检测方法。水样加酸酸化后,经C18固相萃取小柱富集净化,用微乳液相色谱法测定3种目标物的含量。在Inertsil C18色谱柱(150 mm×4.6 mm, 5 μm)上以微乳(3.0%十二烷基硫酸钠(SDS)-6.0%正丁醇-0.8%正庚烷-90.2%(水+0.5%HAc))和乙腈作为流动相进行梯度洗脱,流速1.0 mL/min,检测波长280 nm。结果表明,苯酚、双酚A、2,4-二氯苯酚的检出限(S/N=3)依次为0.74、8.0、8.0 μg/L,线性范围在0.1~10 mg/L范围内,相关系数(r)均大于0.999。将3种酚类化合物定量加到空白水样中,苯酚、双酚A、2,4-二氯苯酚的加标回收率分别为82.7%、87.8%、82.6%,其RSD均小于5%(n=6)。对环境水样的酚类化合物分析也取得了良好的加标回收率,其值均在85.7%~113.2%之间。结果表明,该方法准确可靠、灵敏度高,适用于环境水体中酚类化合物的检测。  相似文献   

16.
建立了亚临界水萃取-高效液相色谱同时测定聚碳酸酯(PC)水杯中双酚A和苯酚迁移量的方法。选择萃取温度120 ℃、萃取压力6.89 MPa(1000 psi)、静态萃取时间1 h、萃取1次对11种样品进行测定。双酚A的迁移量为6.81~11.16 μg/g。5种样品中未检出苯酚,其余样品中苯酚迁移量为3.25~6.08 μg/g。在优化的测定条件下,双酚A和苯酚在8 min内达到基线分离。双酚A和苯酚分别在0.05~20 mg/L和0.02~20 mg/L范围内线性关系良好,相关系数(r)均大于0.9997,检出限分别为7.6 μg/L和2.0 μg/L。日内及日间的重复性(以RSD计)分别小于5.21%及11.63%。传统的浸提法结果表明长时间浸提会使PC材料发生微弱水解。相比传统的浸提法,该方法的萃取效率提高了49~106倍。该方法简便、快速、环保,可用来测定PC水杯中双酚A和苯酚的迁移量。  相似文献   

17.
建立了一种快速、灵敏、准确的同时测定牛蛙全血中双酚A、己烯雌酚、己二烯雌酚、己烷雌酚、4-叔辛基酚和4-壬基酚等6种酚类环境雌激素的分散固相萃取-超快速液相色谱-串联质谱(dSPE-UFLC-MS/MS)分析方法。牛蛙全血样品经含0.1%(v/v)甲酸的甲醇溶液沉淀蛋白后,利用自制的氨基功能化Fe3O4磁性高分子复合微粒(EDA-MPs)作为dSPE吸附剂进行净化,着重考察了沉淀剂、吸附净化时间、吸附剂用量等因素对6种酚类环境雌激素回收率的影响。采用Shim-pack XR-ODSII(100 mm×2.0 mm, 2.2 μm)反相液相色谱柱进行分离,在电喷雾离子源(ESI)负离子多反应监测(MRM)模式下进行检测。结果表明: 6种酚类环境雌激素在0.5~100.0 μg/L范围内具有良好的线性关系(r2≥0.9996),方法的定量限(信噪比大于10)为0.075~0.40 μg/L,方法的精密度为0.6%~6.3%,空白样品中3个不同水平的添加回收率为95.0%~110.0%。本方法适用于牛蛙全血中6种酚类环境雌激素的同时测定。  相似文献   

18.
以双酚A为模板,4-乙烯基吡啶为单体,利用整体材料"原位"聚合技术制备分子印迹聚合物为基质的萃取饼,并与利用一次性注射器空管加工而成的萃取器相结合,建立了分子印迹搅拌饼固相萃取(MIP-SCSE)技术。考察了制备条件对MIP-SCSE选择吸附性能的影响。在此基础上,与高效液相色谱-二极管阵列检测器联用,探讨MIP-SCSE对环境水样中双酚A及其它酚类物质的选择萃取性能,考察萃取过程中基底离子强度、pH值以及吸附与解吸时间等萃取条件对萃取性能的影响。结果表明;在最佳萃取条件下,MIP-SCSE对模板分子及其它酚类物质具有一定选择性能和较高的富集能力,对双酚A的线性范围为1.0~200μg/L;检出限LOD(S/N=3)为0.67μg/L;定量限LOQ(S/N=10)为2.24μg/L。在实际水样分析中,模板分子加标回收率为86.2%~112.2%。在MIP-SCSE使用过程中,萃取饼不与容器壁接触,因此具有优良的使用寿命,至少可连续使用600 h。  相似文献   

19.
Cunha SC  Fernandes JO 《Talanta》2010,83(1):117-125
A novel method combining dispersive liquid-liquid microextraction (DLLME) and heart-cutting multidimensional gas chromatography coupled to mass spectrometry was developed for the determination of free and total bisphenol A (BPA) and bisphenol B (BPB) in human urine samples. The DLLME procedure combines extraction, derivatization and concentration of the analytes into one step. Several important variables influencing the extraction efficiency and selectivity such as nature and volume of extractive and dispersive solvents as well as the amount of acetylating reagent were investigated. The temperature and time to hydrolyze BPA and BPB conjugates with a β-glucuronidase and sulfatase enzyme preparation were also studied. Under the optimized conditions good efficiency extraction (71-93%) and acceptable total DLLME yields (56-77%) were obtained for both analytes. Matrix-matched calibration curves were linear with correlation coefficients higher than 0.996 in the range level 0.1-5 μg/l, and the relative standard deviations (%RSD) were lower than 20% (n = 6). The limits of detection were 0.03 and 0.05 μg/l for BPA and BPB, respectively. The applicability of the proposed method for determining urinary free and total BPA and BPB was assessed by analyzing the human urine of a group of 20 volunteers. Free BPA was detected in 45% of the sample whereas total BPA was detected in 85% of the samples at concentrations ranging between 0.39 and 4.99 μg/l. BPB was detected in conjugated form in two samples.  相似文献   

20.
Five thyreostats(TSs),namely tapazole,thiouracil,methylthiouracil,propylthiouracil,and phenylthiouracil,were determined in bovine urine using ultra-high performance liquid chromatography-tandem mass spectrometry(UHPLC-MS/MS)in positive electrospray ionization mode.Extraction and clean-up were achieved using a ChemElut cartridge with tert-butyl methyl ether,without a derivatization step.Separation was achieved on an Acquity UPLC SS T3 column.The mobile phase was acetonitrile and water containing 0.2%(v/v)formic acid.The mass spectrometer was operated in multiple reaction monitoring mode.Urine samples were spiked with TS solution at levels corresponding to 5,10,15,and 20μg/L.The accuracy(internal standard corrected)ranged from 92%to 107%,with a repeatability precision(relative standard deviation,RSD)less than 15%for all five analytes.The RSDs within-laboratory reproducibility was less than 26%.The decision limits(CCα)and detection capabilities(CCβ)were obtained from a calibration curve and were in the ranges of 3.1-6.1μg/L and 4.0-7.4μg/L,respectively.The CCαand CCβvalues were below the recommended concentration,which was set at 10μg/L.The results show that the described method is suitable for the direct detection of TSs in bovine urine.This method can also be used to determine TSs in porcine urine.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号