首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Wojtczak and Viemeister [J. Acoust. Soc. Am. 106, 1917-1924 (1999)] demonstrated a close relationship between intensity difference limens (DLs) and 4-Hz amplitude modulation (AM) detection thresholds in normal-hearing acoustic listeners. The present study demonstrates a similar relationship between intensity DLs and AM detection thresholds in cochlear-implant listeners, for gated stimuli. This suggests that acoustic and cochlear-implant listeners make use of a similar decision variable to perform intensity discrimination and modulation detection tasks. It can be shown that the absence of compression in electric hearing does not preclude this possibility.  相似文献   

2.
Intensity difference limens (DLs) were measured over a wide intensity range for 200-ms, 1-kHz gated tones and for 200-ms increments in continuous 1-kHz tones. Magnitude estimates also were obtained for the gated tones over a comparable intensity range. The discrimination data are in general agreement with those from earlier studies but they extend them by showing: (1) good discrimination for gated tones over at least a 115-dB dynamic range; (2) a slight increase in the relative DL (delta I/I) as intensity increases above 95 dB SPL; (3) smaller DLs for increments than for gated tones, with the difference approximately independent of intensity; (4) negligible "negative masking" when thresholds are expressed as intensity differences (delta I). For two of the three subjects, magnitude estimates do not conform to a single-exponent power law for suprathreshold intensities. Over the middle range of intensities where a single exponent is appropriate, the value of the exponent is less than 0.1 for all subjects.  相似文献   

3.
Forward-masked psychophysical spatial tuning curves (fmSTCs) were measured in twelve cochlear-implant subjects, six using bipolar stimulation (Nucleus devices) and six using monopolar stimulation (Clarion devices). fmSTCs were measured at several probe levels on a middle electrode using a fixed-level probe stimulus and variable-level maskers. The average fmSTC slopes obtained in subjects using bipolar stimulation (3.7 dBmm) were approximately three times steeper than average slopes obtained in subjects using monopolar stimulation (1.2 dBmm). Average spatial bandwidths were about half as wide for subjects with bipolar stimulation (2.6 mm) than for subjects with monopolar stimulation (4.6 mm). None of the tuning curve characteristics changed significantly with probe level. fmSTCs replotted in terms of acoustic frequency, using Greenwood's [J. Acoust. Soc. Am. 33, 1344-1356 (1961)] frequency-to-place equation, were compared with forward-masked psychophysical tuning curves obtained previously from normal-hearing and hearing-impaired acoustic listeners. The average tuning characteristics of fmSTCs in electric hearing were similar to the broad tuning observed in normal-hearing and hearing-impaired acoustic listeners at high stimulus levels. This suggests that spatial tuning is not the primary factor limiting speech perception in many cochlear implant users.  相似文献   

4.
Sensitivity to acoustic cues in cochlear implant (CI) listening under natural conditions is a potentially complex interaction between a number of simultaneous factors, and may be difficult to predict. In the present study, sensitivity was measured under conditions that approximate those of natural listening. Synthesized words having increases in intensity or fundamental frequency (F0) in a middle stressed syllable were presented in soundfield to normal-hearing listeners and to CI listeners using their everyday speech processors and programming. In contrast to the extremely fine sensitivity to electrical current observed when direct stimulation of single electrodes is employed, difference limens (DLs) for intensity were larger for the CI listeners by a factor of 2.4. In accord with previous work, F0 DLs were larger by almost one order of magnitude. In a second experiment, it was found that the presence of concurrent intensity and F0 increments reduced the mean DL to half that of either cue alone for both groups of subjects, indicating that both groups combine concurrent cues with equal success. Although sensitivity to either cue in isolation was not related to word recognition in CI users, the listeners having lower combined-cue thresholds produced better word recognition scores.  相似文献   

5.
The study measured listener sensitivity to increments in the inter-onset interval (IOI) separating pairs of successive 20-ms 4000-Hz tone pulses. A silent interval between the tone pulses was adjusted across conditions to create reference tonal IOI values of 25-600 ms. For each condition, a duration DL for increments of the tonal IOI was measured in listeners comprised of young normal-hearing adults and two groups of older adults with and without high-frequency hearing loss. Discrimination performance of all listeners was poorest for the shorter reference IOIs, and improved to stable levels for longer reference intervals exceeding about 200 ms. Temporal sensitivity of the young listeners was significantly better than that of the elderly listeners in each condition, with the largest age-related differences observed for the shortest reference interval. Age-related differences were also observed for duration DLs measured using single 4000-Hz tone bursts set to three reference durations in the range 50-200 ms. The tone DLs of all listeners were smaller than the corresponding tone-pair IOI DLs, particularly for the shorter reference stimulus durations. There were no significant performance differences observed between the older listeners with and without hearing loss for either discrimination task.  相似文献   

6.
The experiments examined age-related changes in temporal sensitivity to increments in the interonset intervals (IOI) of components in tonal sequences. Discrimination was examined using reference sequences consisting of five 50-ms tones separated by silent intervals; tone frequencies were either fixed at 4 kHz or varied within a 2-4-kHz range to produce spectrally complex patterns. The tonal IOIs within the reference sequences were either equal (200 or 600 ms) or varied individually with an average value of 200 or 600 ms to produce temporally complex patterns. The difference limen (DL) for increments of IOI was measured. Comparison sequences featured either equal increments in all tonal IOIs or increments in a single target IOI, with the sequential location of the target changing randomly across trials. Four groups of younger and older adults with and without sensorineural hearing loss participated. Results indicated that DLs for uniform changes of sequence rate were smaller than DLs for single target intervals, with the largest DLs observed for single targets embedded within temporally complex sequences. Older listeners performed more poorly than younger listeners in all conditions, but the largest age-related differences were observed for temporally complex stimulus conditions. No systematic effects of hearing loss were observed.  相似文献   

7.
Psychophysical pulse-train forward-masking (PTFM) recovery functions were measured in fifteen subjects with the Nucleus mini-22 cochlear implant and six subjects with the Clarion cochlear implant. Masker and probe stimuli were 500-Hz trains of 200- or 77-micros/phase biphasic current pulses. Electrode configurations were bipolar for Nucleus subjects and monopolar for Clarion subjects. Masker duration was 320 ms. Probe duration was either 10 ms or 30 ms. Recovery functions were measured for a high-level masker on a middle electrode in all 21 subjects, on apical and basal electrodes in 7 of the Nucleus and 3 of the Clarion subjects, and for multiple masker levels on the middle electrode in 8 Nucleus subjects and 6 Clarion subjects. Recovery functions were described by an exponential process in which threshold shift (in microA) decreased exponentially with increasing time delay between the offset of the masker pulse train and the offset of the probe pulse train. All but 3 of the 21 subjects demonstrated recovery time constants on a middle electrode that were less than 95 ms. The mean time constant for these 18 subjects was 54 ms (s.d. 17 ms). Three other subjects tested on three electrodes exhibited time constants larger than 95 ms from an apical electrode only. Growth-of-masking slopes depended upon time delay, as expected from an exponential recovery process, i.e., progressively shallower slopes were observed at time delays of 10 ms and 50 ms. Recovery of threshold shift (in microA) for PTFM in electrical hearing behaves inthe same way as recovery of threshold shift (in dB) for pure-tone forward masking in acoustic hearing. This supports the concept that linear microamps are the electrical equivalent of acoustic decibels. Recovery from PTFM was not related to speech recognition in a simple manner. Three subjects with prolonged PTFM recovery demonstrated poor speech scores. The remaining subjects with apparently normal PTFM recovery demonstrated speech scores ranging from poor to excellent. Findings suggest that normal PTFM recovery is only one of several factors associated with good speech recognition in cochlear-implant listeners. Comparisons of recovery curves for 10- and 30-ms probe durations in two subjects showed little or no temporal integration at time delays less than 95 ms where recovery functions have steep slopes. The same subjects exhibited large amounts of temporal integration at longer time delays where recovery slopes are more gradual. This suggests that probe detection depends primarily on detection of the final pulses in the probe stimulus and supports the use of offset-to-offset time delays for characterizing PTFM recovery in electric hearing.  相似文献   

8.
This paper examines how intensity discrimination depends on the test frequency, the level, and the subjects's high-frequency hearing. Three experiments were performed. In the first experiment, intensity discrimination of pulsed tones was measured as a function of level at 1 and 14 kHz in five listeners. Results show less deviation from Weber's law at 14 kHz than at 1 kHz. In the second experiment, intensity discrimination was measured for a 1-kHz tone at 90-dB SPL as a function of the cutoff frequency of a high-pass masking noise in two listeners. Results show that the audibility of very high frequencies is important for frequency discrimination at 1 kHz. The DL increased by a factor between 1.5 and 2.0 as the cutoff frequency of the noise was lowered from 19 to 6 kHz. In the third experiment, thresholds from 6 to 20 kHz and intensity discrimination for a 1-kHz tone was measured in 12 listeners. Results show that the DLs at 80-dB SPL are correlated with the ability to hear very high frequencies. Results of all three experiments are consistent with the multiband version of the excitation-pattern model for intensity discrimination [Florentine and Buus, J. Acoust. Soc. Am. 70, 1646-1654 (1981)].  相似文献   

9.
The study measured listener sensitivity to increments in the inter-onset intervals (IOIs) of successive 20-ms 4000-Hz tone bursts in isochronous sequences. The stimulus sequences contained two-six tone bursts, separated equally by silent intervals, with tonal IOIs ranging from 25 to 100 ms. Difference limens (DLs) for increments of the tonal IOIs were measured to assess listener sensitivity to changes of sequence rate. Comparative DLs were also measured for increments of a single interval located within six-tone isochronous sequences with different tone rates. Listeners included younger normal-hearing adults and two groups of older adults with and without high-frequency sensorineural hearing loss. The results, expressed as Weber fractions (DL/IOI), revealed that discrimination improved as the sequence tone rate decreased and the number of tonal components increased. Discrimination of a single sequence interval also improved as the number of sequence components increased from two to six but only for brief intervals and fast sequence rates. Discrimination performance of the older listeners with and without hearing loss was equivalent and significantly poorer than that of the younger listeners. The discrimination results are examined and discussed within the context of multiple-look mechanisms and possible age-related differences in the sensory coding of signal onsets.  相似文献   

10.
Speech recognition was measured as a function of spectral resolution (number of spectral channels) and speech-to-noise ratio in normal-hearing (NH) and cochlear-implant (CI) listeners. Vowel, consonant, word, and sentence recognition were measured in five normal-hearing listeners, ten listeners with the Nucleus-22 cochlear implant, and nine listeners with the Advanced Bionics Clarion cochlear implant. Recognition was measured as a function of the number of spectral channels (noise bands or electrodes) at signal-to-noise ratios of + 15, + 10, +5, 0 dB, and in quiet. Performance with three different speech processing strategies (SPEAK, CIS, and SAS) was similar across all conditions, and improved as the number of electrodes increased (up to seven or eight) for all conditions. For all noise levels, vowel and consonant recognition with the SPEAK speech processor did not improve with more than seven electrodes, while for normal-hearing listeners, performance continued to increase up to at least 20 channels. Speech recognition on more difficult speech materials (word and sentence recognition) showed a marginally significant increase in Nucleus-22 listeners from seven to ten electrodes. The average implant score on all processing strategies was poorer than scores of NH listeners with similar processing. However, the best CI scores were similar to the normal-hearing scores for that condition (up to seven channels). CI listeners with the highest performance level increased in performance as the number of electrodes increased up to seven, while CI listeners with low levels of speech recognition did not increase in performance as the number of electrodes was increased beyond four. These results quantify the effect of number of spectral channels on speech recognition in noise and demonstrate that most CI subjects are not able to fully utilize the spectral information provided by the number of electrodes used in their implant.  相似文献   

11.
Frequency and intensity discrimination in humans and monkeys   总被引:1,自引:0,他引:1  
Frequency and intensity DLs were compared in humans and monkeys using a repeating standard "yes-no" procedure in which subjects reported frequency increments, frequency decrements, intensity increments, or intensity decrements in an ongoing train of 1.0-kHz tone bursts. There was only one experimental condition (intensity increments) in which monkey DLs (1.5-2.0 dB) overlapped those of humans (1.0-1.8 dB). For discrimination of both increments and decrements in frequency, monkey DLs (16-33 Hz) were approximately seven times larger than those of humans (2.4-4.8 Hz), and for discrimination of intensity decrements, monkey DLs (4.4-7.0 dB) were very unstable and larger than those of humans (1.0-1.8 dB). For intensity increment discrimination, humans and monkeys also exhibited similar DLs as SL was varied. However, for frequency increment discrimination, best DLs for humans occurred at a high (50 dB) SL, whereas best DLs for monkeys occurred at a moderate (30 dB) SL. Results are discussed in terms of various neural mechanisms that might be differentially engaged by humans and monkeys in performing these tasks; for example, different amounts of temporal versus rate coding in frequency discrimination, and different mechanisms for monitoring rate decreases in intensity discrimination. The implications of these data for using monkeys as models of human speech sound discrimination are also discussed.  相似文献   

12.
Thresholds of ongoing interaural time difference (ITD) were obtained from normal-hearing and hearing-impaired listeners who had high-frequency, sensorineural hearing loss. Several stimuli (a 500-Hz sinusoid, a narrow-band noise centered at 500 Hz, a sinusoidally amplitude-modulated 4000-Hz tone, and a narrow-band noise centered at 4000 Hz) and two criteria [equal sound-pressure level (Eq SPL) and equal sensation level (Eq SL)] for determining the level of stimuli presented to each listener were employed. The ITD thresholds and slopes of the psychometric functions were elevated for hearing-impaired listeners for the two high-frequency stimuli in comparison to: the listener's own low-frequency thresholds; and data obtained from normal-hearing listeners for stimuli presented with Eq SPL interaurally. The two groups of listeners required similar ITDs to reach threshold when stimuli were presented at Eq SLs to each ear. For low-frequency stimuli, the ITD thresholds of the hearing-impaired listener were generally slightly greater than those obtained from the normal-hearing listeners. Whether these stimuli were presented at either Eq SPL or Eq SL did not differentially affect the ITD thresholds across groups.  相似文献   

13.
This study investigated the benefits of adding unprocessed low-frequency information to acoustic simulations of cochlear-implant processing in normal-hearing listeners. Implant processing was simulated using an eight-channel noise-excited envelope vocoder, and low-frequency information was added by replacing the lower frequency channels of the processor with a low-pass-filtered version of the original stimulus. Experiment 1 measured sentence-level speech reception as a function of target-to-masker ratio, with either steady-state speech-shaped noise or single-talker maskers. Experiment 2 measured listeners' ability to identify two vowels presented simultaneously, as a function of the F0 difference between the two vowels. In both experiments low-frequency information was added below either 300 or 600 Hz. The introduction of the additional low-frequency information led to substantial and significant improvements in performance in both experiments, with a greater improvement observed for the higher (600 Hz) than for the lower (300 Hz) cutoff frequency. However, performance never equaled performance in the unprocessed conditions. The results confirm other recent demonstrations that added low-frequency information can provide significant benefits in intelligibility, which may at least in part be attributed to improvements in F0 representation. The findings provide further support for efforts to make use of residual acoustic hearing in cochlear-implant users.  相似文献   

14.
This study examines the relationship between a temporal masking effect and cochlear hearing impairment. The threshold level of a long-duration broadband masker needed to mask a short-duration tonal signal was measured for signals presented 2 ms (short-delay) or 202 ms (long-delay condition) after masker onset. The difference between these thresholds is the temporal effect. In two previous studies with normal-hearing listeners, estimates of gain of the cochlear active process derived from such data suggested a decrease in gain during the course of the masker. This hypothesis was further examined in the present study by testing listeners with mild to moderate cochlear hearing impairment. Results are consistent with a decrease in gain in the short-delay condition with increasing hearing impairment, and also less change in gain with increasing hearing impairment.  相似文献   

15.
Frequency and intensity DLs were measured in 26 human infants (ages 7-9 months) and six young adults using a repeating standard "yes-no" operant headturning technique and an adaptive staircase (tracking) psychophysical procedure. Subjects were visually reinforced for responding to frequency increments, frequency decrements, intensity increments, or intensity decrements in an ongoing train of 1.0-kHz tone bursts, and stimulus control was monitored using randomly interleaved probe and catch trials. Infants were easily conditioned to respond to both increments and decrements in frequency, and DLs ranged from 11-29 Hz, while adult DLs ranged from 3-5 Hz. Infants also easily discriminated intensity increments, and DLs ranged from 3-12 dB, while adult DLs ranged from 1-2 dB. No infants successfully discriminated intensity decrements, although adults experienced no difficulty with this task and produced DLs similar to those for increments. The apparent inability of infants to discriminate intensity decrements suggests that the infant CNS may not be well adapted to monitor rate decreases in populations of peripheral auditory neurons.  相似文献   

16.
Many hearing-impaired listeners suffer from distorted auditory processing capabilities. This study examines which aspects of auditory coding (i.e., intensity, time, or frequency) are distorted and how this affects speech perception. The distortion-sensitivity model is used: The effect of distorted auditory coding of a speech signal is simulated by an artificial distortion, and the sensitivity of speech intelligibility to this artificial distortion is compared for normal-hearing and hearing-impaired listeners. Stimuli (speech plus noise) are wavelet coded using a complex sinusoidal carrier with a Gaussian envelope (1/4 octave bandwidth). Intensity information is distorted by multiplying the modulus of each wavelet coefficient by a random factor. Temporal and spectral information are distorted by randomly shifting the wavelet positions along the temporal or spectral axis, respectively. Measured were (1) detection thresholds for each type of distortion, and (2) speech-reception thresholds for various degrees of distortion. For spectral distortion, hearing-impaired listeners showed increased detection thresholds and were also less sensitive to the distortion with respect to speech perception. For intensity and temporal distortion, this was not observed. Results indicate that a distorted coding of spectral information may be an important factor underlying reduced speech intelligibility for the hearing impaired.  相似文献   

17.
In a recent study [S. Gordon-Salant, J. Acoust. Soc. Am. 80, 1599-1607 (1986)], young and elderly normal-hearing listeners demonstrated significant improvements in consonant-vowel (CV) recognition with acoustic modification of the speech signal incorporating increments in the consonant-vowel ratio (CVR). Acoustic modification of consonant duration failed to enhance performance. The present study investigated whether consonant recognition deficits of elderly hearing-impaired listeners would be reduced by these acoustic modifications, as well as by increases in speech level. Performance of elderly hearing-impaired listeners with gradually sloping and sharply sloping sensorineural hearing losses was compared to performance of elderly normal-threshold listeners (reported previously) for recognition of a variety of nonsense syllable stimuli. These stimuli included unmodified CVs, CVs with increases in CVR, CVs with increases in consonant duration, and CVs with increases in both CVR and consonant duration. Stimuli were presented at each of two speech levels with a background of noise. Results obtained from the hearing-impaired listeners agreed with those observed previously from normal-hearing listeners. Differences in performance between the three subject groups as a function of level were observed also.  相似文献   

18.
The purpose of this study is to specify the contribution of certain frequency regions to consonant place perception for normal-hearing listeners and listeners with high-frequency hearing loss, and to characterize the differences in stop-consonant place perception among these listeners. Stop-consonant recognition and error patterns were examined at various speech-presentation levels and under conditions of low- and high-pass filtering. Subjects included 18 normal-hearing listeners and a homogeneous group of 10 young, hearing-impaired individuals with high-frequency sensorineural hearing loss. Differential filtering effects on consonant place perception were consistent with the spectral composition of acoustic cues. Differences in consonant recognition and error patterns between normal-hearing and hearing-impaired listeners were observed when the stimulus bandwidth included regions of threshold elevation for the hearing-impaired listeners. Thus place-perception differences among listeners are, for the most part, associated with stimulus bandwidths corresponding to regions of hearing loss.  相似文献   

19.
This study tested the relationship between frequency selectivity and the minimum spacing between harmonics necessary for accurate fo discrimination. Fundamental frequency difference limens (fo DLs) were measured for ten listeners with moderate sensorineural hearing loss (SNHL) and three normal-hearing listeners for sine- and random-phase harmonic complexes, bandpass filtered between 1500 and 3500 Hz, with fo's ranging from 75 to 500 Hz (or higher). All listeners showed a transition between small (good) fo DLs at high fo's and large (poor) fo DLs at low fo's, although the fo at which this transition occurred (fo,tr) varied across listeners. Three measures thought to reflect frequency selectivity were significantly correlated to both the fo,tr and the minimum fo DL achieved at high fo's: (1) the maximum fo for which fo DLs were phase dependent, (2) the maximum modulation frequency for which amplitude modulation and quasi-frequency modulation were discriminable, and (3) the equivalent rectangular bandwidth of the auditory filter, estimated using the notched-noise method. These results provide evidence of a relationship between fo discrimination performance and frequency selectivity in listeners with SNHL, supporting "spectral" and "spectro-temporal" theories of pitch perception that rely on sharp tuning in the auditory periphery to accurately extract fo information.  相似文献   

20.
The ability to discriminate changes in the length of vowels and tonal complexes (filled intervals) and in the duration of closure in stop consonants and gaps in tonal complexes (unfilled intervals) was studied in three normally hearing and seven severely hearing-impaired listeners. The speech stimuli consisted of the vowels (i, I, u, U, a, A) and the consonants (p, t, k), and the tonal complexes consisted of digitally generated sinusoids at 0.5, 1, and 2 kHz. The signals were presented at conversational levels for each listener group, and a 3IFC adaptive procedure was used to estimate difference limens (DLs). The DLs for speech were similar to those for tonal complex stimuli in both the filled and unfilled conditions. Both normally and impaired-hearing listeners demonstrated greater acuity for changes in the duration of filled than unfilled intervals. Mean thresholds for filled intervals obtained from normally hearing listeners were smaller than those obtained from hearing-impaired listeners. For unfilled intervals, however, the difference between listener groups was not significant. A few hearing-impaired listeners demonstrated temporal acuity comparable to that of normally hearing listeners for several listening conditions. Implications of these results are discussed with regard to speech perception in normally and impaired-hearing individuals.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号