共查询到20条相似文献,搜索用时 15 毫秒
1.
Manjeet Kumar D. P. S. Rathore Ajai K. Singh 《Analytical and bioanalytical chemistry》2001,370(4):377-382
Amberlite XAD-2 has been functionalized by coupling it to quinalizarin [1,2,5,8-tetrahydroxyanthraquinone] by means of an -N = N- spacer. Elemental analysis, thermogravimetric analysis, and infrared spectra were used to characterize the resulting new polymer matrix. The matrix has been used to preconcentrate Cu(II), Cd(II), Co(II), Pb(II), Zn(II), and Mn(II) before their determination by flame atomic absorption spectrometry (FAAS). UO2(II) has been preconcentrated for fluorimetric determination. The optimum pH values for maximum adsorption of the metals are between 5.0 and 7.0. All these metal ions are desorbed (recovery 91–99%) with 4 mol L–1 HNO3. The adsorptive capacity of the resin was found to be in the range 0.94–5.28 mg metal g–1 resin and loading half-life (t1/2) between 5.3 and 15.0 min. The effects of NaF, NaCl, NaNO3, Na2SO4, Na3PO4, Ca(II), and Mg(II) on the adsorption of these metal ions (0.2 μg mL–1) are reported. The lower limits of detection for these metal ions are between 1 and 15.0 μg L–1. After enrichment on this matrix flame AAS has been used to determine these metal ions (except the uranyl ion) in river water samples (RSD ≤ 6.5%); fluorimetry was used to determine uranyl ion in well water samples (RSD ≤ 6.3%). Cobalt from pharmaceutical vitamin tablets was preconcentrated by use of this chelating resin and estimated by FAAS (RSD ~ 4%). 相似文献
2.
Four chelating matrices prepared by coupling Amberlite XAD-2 with chromotropic acid (AXAD-2-CA or 1), pyrocatechol (AXAD-2-PC or 2) and thiosalicylic acid (AXAD-2-TSA or 3) through azo spacer and impregnation of Amberlite XAD-7 with xylenol orange (AXAD-7-XO or 4) have been studied for enrichment of lead(II). All the four resins quantitatively sorb Pb(II) at pH 3.0-8.0 when the flow rate is maintained between 2 and 10 mlmin(-1). HNO(3) (0.5-4.0 M) instantaneously elutes Pb(II) from all the four chelating resins. The sorption capacity is in the range 16.0-186.0 mumolg(-1) and loading half time (t(1/2)) between 3.2 and 15.5 min. The tolerance limits of electrolytes (NaCl, NaBr, NaNO(3), Na(2)SO(4), Na(3)PO(4)) and cations (Ca and Mg) are reported. Phosphate interferes in the sorption with 3 and 4. The limit of detection and limit of quantification have been found to be in the ranges 2.44-7.87 and 2.76-8.64 ngml(-1), respectively. Lead has been determined in river (RSD approximately 2.6-12.8%) and tap (RSD approximately 1.8-7.2%) water samples. 相似文献
3.
Thiosalicylic acid (TSA)-modified Amberlite XAD-2 (AXAD-2) was synthesized by coupling TSA with the support matrix AXAD-2 through an azo spacer. The resulting chelating resin was characterized by elemental analyses, thermogravimetric analysis (TGA) and infrared spectra. The newly designed resin quantitatively sorbs CdII, CoII, CuII, FeIII, NiII and ZnII at pH 3.5-7.0 when the flow rate is maintained between 2 and 4 ml min-1. The HCl or HNO3 (2 mol l-1) instantaneously elutes all the metal ions. The sorption capacity is 197.5, 106.9, 214.0, 66.2, 309.9 and 47.4 mumol g-1 of the resin for cadmium, cobalt, copper, iron, nickel and zinc, respectively, whereas their preconcentration factor is between 180-400. The breakthrough volume of HCl or HNO3 for elution of these metal ions was found to be 4-8 ml. The limit of detection (LOD) for CdII, CoII, CuII, FeIII, NiII and ZnII was 0.48, 0.20, 4.05, 0.98, 1.28 and 3.94 micrograms l-1, respectively, and the limit of quantification (LOQ) was found to be 0.51, 0.29, 4.49, 1.43, 1.58 and 4.46 micrograms l-1, respectively. The loading half time, t1/2, for the cations was found to be less than 2.0 min, except for nickel for which the value was 13.1 min. The determination of each of these six cations is possible in the presence of other five, if their concentration is up to 4 times. All six metals were determined in river water (RSD approximately 0.7-7.7%) and tap water samples (RSD approximately 0.3-5.7%). The estimation of Co was made in the samples of multivitamin tablets (RSD < 2.3%). The results agree with those quoted by manufacturers. 相似文献
4.
Six chelating matrices have been prepared by anchoring 2,3-dihydroxypyridine (DHP) and 2-{[1-(3,4-dihydroxyphenyl)methylidene]amino}benzoic
acid (DMABA) onto Amberlite XAD-2 and XAD-16 and 3,4-dihydroxybenzaldehyde (DHB), and iminodiacetic acid (IDA) onto silica
gel. The materials were explored for enrichment of palladium followed by its determination with flame AAS. The optimum pH
ranges for quantitative solid phase extraction by these matrices are from 4.0–5.5 to 5.5–7.0. The flow rates (column procedure)
and concentration of HCl required for desorption have been optimized. Thiourea (∼3%) is essential for quantitative recovery
of Pd. The t1/2 values are between 5 and 15 min. The sorption capacity varies from 38 to 192 μmol g−1 (highest for silica gel loaded with iminodiacetic acid). The preconcentration factors were found in the range 20–150. Tolerance
limits of foreign species in the enrichment are reported. The enrichment procedures coupled with FAAS determinations were
applied to synthetic solutions corresponding to standards GBW07293 and NIST SRM 2557 successfully. 相似文献
5.
A method of silver preconcentration by using a column containing Amberlite XAD-16 resin and this future determination by a flame AAS after elution is proposed. The effect of the factors such as pH, the nature of complexing agent, sample volume, flow rate, the type and concentration of elution solution on the preconcentration efficiency have been investigated. The influence of some matrix elements on the recovery of silver were also examined. It was found, that the quantitative recovery of thiocyanate complex of silver was obtained from nitric acid solution (pH 2) as 99.20+/-0.07% at the 95% confidence level. A preconcentration factor up to 75 could be obtained. The detection limit of silver was 0.047 mg l(-1). The adsorption of silver onto Amberlite XAD-16 can be formally described by a Langmuir equation with maximum adsorption capacity 4.66 mg g(-1) (0.043 mmol g(-1)). The proposed method was applied to determination of silver in standard alloy with relative error 6.25%. 相似文献
6.
A new procedure has been developed for chromium speciation in aqueous solution by the use of micellar, ion-association, solid-phase extraction techniques (SPE) followed by flame atomic absorption spectrometry. The method was based on the use of C-18 bonded phase silica SPE disks for retention of ion-associated Cr(VI) with cetyl trimethyl ammonium bromide (CTAB), elution of the retained species and subsequent detection by flame atomic absorption spectrometry (FAAS). Cr(III) was oxidized by potassium persulfate to Cr(VI), then the total chromium was retained on the disk and determined by FAAS. The amount of Cr(III) was calculated by the difference between the total and Cr(VI) values. The calculated limit of detections (LOD) (based on 3sigma) are 15 microg L(-1) and 20 microg L(-1) for Cr(VI) and Cr(III) respectively. No considerable interferences have been observed from other investigated anions and cations and the method has been successfully applied to water samples taken from the Karoon River in Khuzestan province. 相似文献
7.
Flow injection wetting-film extraction system for flame atomic absorption spectrometric determination of cadmium in environmental waters 总被引:1,自引:0,他引:1
Ibrahim S.I. Adam 《Talanta》2009,77(3):1160-1164
A newly simple flow injection wetting-film extraction system coupled to flame atomic absorption spectrometry (FAAS) has been developed for trace amount of cadmium determination. The sample was mixed on-line with sodium diethyl dithiocarbamate and the produced non-charged Cd(II)-diethyl dithiocarbamate (DDTC) chelate complex was extracted on the thin film of diisobutyl ketone (DIBK) on the inner wall of the PTFE extraction coil. The wetting-film with the extracted analyte was then eluted by a segment of the cover solvent, and transported directly to the FAAS for evaluation. All the important chemical and flow parameters were optimized. Under the optimized conditions an enhancement factor of 35, a sample frequency of 22 h−1 and a detection limit of cL = 0.7 μg l−1 Cd(II) were obtained for 60 s preconcentration time. The calibration curve was linear over the concentration range 1.5-45.0 μg l−1 Cd(II) and the relative standard deviation, R.S.D. (n = 10) was 3.9%, at 10.0 μg l−1 concentration level. The developed method was successfully applied to cadmium determination in a variety of environmental water samples as well as waste-water sample. 相似文献
8.
C. Herrero Latorre J. Álvarez MéndezAuthor VitaeJ. Barciela GarcíaAuthor Vitae S. García MartínAuthor VitaeR.M. Peña CrecenteAuthor Vitae 《Analytica chimica acta》2012
New materials have significant impact on the development of new methods and instrumentation for chemical analysis. From the discovery of carbon nanotubes in 1991, single and multi-walled carbon nanotubes – due to their high adsorption and desorption capacities – have been employed as sorption substrates in solid-phase extraction for the preconcentration of metal species from diverse matrices. Looking for successive improvements in sensitivity and selectivity, in the past few years, carbon nanotubes have been utilized as sorbents for solid phase extraction in three different ways: like as-grown, oxidized and functionalized nanotubes. In the present paper, an overview of the recent trends in the use of carbon nanotubes for solid phase extraction of metal species in environmental, biological and food samples is presented. The determination procedures involved the adsorption of metals on the nanotube surface, their quantitative desorption and subsequent measurement by means of atomic spectrometric techniques such as flame atomic absorption spectrometry, electrothermal atomic absorption spectrometry or inductively coupled plasma atomic emission spectrometry/mass spectrometry, among others. Synthesis, purification and types of carbon nanotubes, as well as the diverse chemical and physical strategies for their functionalization are described. Based on 140 references, the performance and general properties of the applications of solid phase extraction based on carbon nanotubes for metal species atomic spectrometric determination are discussed. 相似文献
9.
The silica gel modified with (3-aminopropyl-triethoxysilane) was reacted with 5-formyl-8-hydroxyquinoline (FHOQx) to anchor 8-quinolinol ligand on the silica gel. It was characterised with cross polarisation magic angle spinning (CPMAS) NMR and diffuse reflectance infrared Fourier transformation (DRIFT) spectroscopy and used for the preconcentration of Cu(II), Pb(II), Ni(II), Fe(III), Cd(II), Zn(II) and Co(II) prior to their determination by flame atomic absorption spectrometry. The surface area of the modified silica gel has been found to be 227 m2 g−1 and the two pKa values as 3.8 and 8.0. The optimum pH ranges for quantitative sorption are 4.0–7.0, 4.5–7.0, 3.0–6.0, 5.0–8.0, 5.0–8.0, 5.0–8.0 and 4.0–7.0 for Cu, Pb, Fe, Zn, Co, Ni and Cd, respectively. All the metals can be desorbed with 2.5 mol l−1 HCl or HNO3. The sorption capacity for these metal ions is in range of 92–448.0 μmol g−1 and follows the order Cd3, NaCl, NaBr, Na2SO4 and Na3PO4, glycine, sodium citrate, EDTA, humic acid and cations Ca(II), Mg(II), Mn(II) and Cr(III) in the sorption of all the seven metal ions are reported. The preconcentration factors are 150, 250, 200, 300, 250, 300 and 200 for Cd, Co, Zn, Cu, Pb, Fe and Ni, respectively and t1/2 values <1 min except for Ni. The 95% extraction by batch method takes ≤25 min. The simultaneous enrichment and determination of all the metals are possible if the total load of the metal ions is less than sorption capacity. In river water samples all these metal ions were enriched with the present ligand anchored silica gel and determined with flame atomic absorption spectrometer (R.S.D.≤6.4%). Cobalt contents of pharmaceutical samples (vitamin tablet) were preconcentrated with the present chelating silica gel and estimated by flame AAS, with R.S.D.1.4%. The results are in the good agreement with the certified value, 1.99 μg g−1 of the tablets. Iron and copper in certified reference materials (synthetic) SLRS-4 and SLEW-3 have been enriched with the modified silica gel and estimated with R.S.D.<5%. 相似文献
10.
L. Elçi M. Soylak A. Uzun E. Büyükpatır M. Doğan 《Analytical and bioanalytical chemistry》2000,368(4):358-361
A simple flame atomic absorption spectrometric (FAAS) procedure for the determination of lead, bismuth, gold, palladium and cadmium as impurities in Raney nickel and nickel oxide was developed using a preconcentration step on an Amberlite XAD-16 resin packed column. Lead, bismuth, gold, palladium and cadmium were quantitatively recovered and separated from a solution containing 1 M HCl and 0.3 M NaI by the column system. Effects of the various parameters such as reagent concentrations, sample volume, matrix effects, etc. have been investigated. Under optimized conditions, the relative standard deviation of the combined method of sample treatment, preconcentration and determination with FAAS (n = 7) is generally lower than 12%. The limit of detection (3s, n = 20) was between 10–270 ng/g. The results were used for separation and preconcentration of five trace elements from nickel matrices. 相似文献
11.
Rakesh K. Sharma Parul Pant 《International journal of environmental analytical chemistry》2013,93(7):503-514
A new chelating polymer has been developed using Amberlite XAD-16 anchored with Quercetin. The modified polymer was characterised by Fourier Transform Infra Red (FTIR) spectroscopy, thermogravimetric analysis, surface area analysis and elemental analysis. The Quercetin anchored polymer showed superior binding affinity for Cr(III), Mn(II), Fe(III), Co(II), Ni(II) and Cu(II) with greater than 95% adsorption under optimum conditions. The optimum pH conditions for the quantitative sorption of metal ions were studied. The developed method showed superior extraction qualities with high metal loading capacities of 387, 313, 195, 473, 210 and 320 µmol g?1 for Cu(II), Co(II), Cr(III), Fe(III), Mn(II) and Ni(II), respectively. The rate of metal ion uptake i.e. kinetics studies performed under optimum levels, showed t 1/2 for Co(II), Cu(II), Cr(III), Fe(III), Mn(II) and Ni(II) is 20, 15, 25, 10, 30 and 15 min, respectively. Desorption of metal ions was effective with 10 mL of 2 M HCl prior to analysis using flame atomic absorption spectrophotometer. The chelating polymer was highly ion selective in nature even in the presence of interferent ions, with a high preconcentrating ability for the metal ions of interest. The developed chelating polymer was tested on its utility with synthetic and real samples like river, tap water samples and also with multivitamin tablets. It showed relative standard deviation (R.S.D.) values of/less than 3.0% reflecting on the accuracy and reproducibility of data using the newly developed chelating polymer. 相似文献
12.
A new column, solid-phase extraction (SPE), preconcentration method was developed for determination of Cd, Co, and Cu ions
in natural water samples by flame atomic absorption spectrometry. The procedure is based on the retention of analytes in the
form of 2,4-dinitrophenyldiazoaminoazobenzene (DNDAA) complex on a mini column of DNDAA-XAD-2 resin. The effects of pH, eluent
type, eluent concentration, eluent volume, resin quantity, sample volume, sample flow rate, and matrix ions (Na, Ca, and Mg)
were investigated on the recovery of the metals using model solutions. The detection limit for Cd, Co, and Cu was 0.062, 0.084,
and 0.057 μg L−1 and the quantification limit was 0.17, 0.24, and 0.12 μg L−1 respectively. The method was validated by the analysis of a certified reference material with the results being in agreement
with those quoted by manufactures. The developed method was applied to the determination of trace metal ions in tap water,
river water samples with satisfactory results. 相似文献
13.
L. El?i M. Soylak A. Uzun E. Büyükpatr M. Doan 《Fresenius' Journal of Analytical Chemistry》2000,368(4):358-361
A simple flame atomic absorption spectrometric (FAAS) procedure for the determination of lead, bismuth, gold, palladium and
cadmium as impurities in Raney nickel and nickel oxide was developed using a preconcentration step on an Amberlite XAD-16
resin packed column. Lead, bismuth, gold, palladium and cadmium were quantitatively recovered and separated from a solution
containing 1 M HCl and 0.3 M NaI by the column system. Effects of the various parameters such as reagent concentrations, sample
volume, matrix effects, etc. have been investigated. Under optimized conditions, the relative standard deviation of the combined
method of sample treatment, preconcentration and determination with FAAS (n = 7) is generally lower than 12%. The limit of detection (3s, n = 20) was between 10–270 ng/g. The results were used for separation and preconcentration of five trace elements from nickel
matrices.
Received: 8 February 2000 / Revised: 31 March 2000 / Accepted: 7 April 2000 相似文献
14.
15.
Mustafa Tuzen 《Analytica chimica acta》2004,504(2):325-334
A column solid-phase extraction method for the preconcentration and determination of cadmium(II), copper(II), cobalt(II), iron(III), lead(II), nickel(II) and zinc(II) dithizone chelates by atomic absorption spectrometry has been described. Diaion HP-2MG was used as adsorbent for column studies. The influences of the various analytical parameters including pH of the aqueous solutions, amounts of ligand and resin were investigated for the retentions of the analyte ions. The recovery values are ranged from 95 to 102%. The influences of alkaline and earth alkaline ions were also discussed. The preconcentration factor was 375, when the sample volume and final volume are 750 and 2 ml, respectively. The detection limits of the analyte ions (k=3, N=21) were varying 0.08 μg/l for cadmium to 0.25 μg/l for lead. The relative standard deviations of the determinations at the concentration range of 1.8×10−4 to 4.5×10−5 mmol for the investigated elements were found to be lower than 9%. The proposed solid-phase extraction procedure were applied to the flame atomic absorption spectrometric determinations of analyte ions in natural waters (sea, tap, river), microwave digested samples (milk, red wine and rice) and two different reference standard materials (SRM1515 apple leaves and NRCC-SLRS-4 riverine water). 相似文献
16.
A new preconcentration method was developed for the determination of trace amounts of Cu(II), Fe(III), Pb(II), Ni(II), and Cd(II) on a double-walled carbon nanotube disk. 4-(2-Thiazolylazo) resorcinol was used as a complexing reagent. The effects of parameters, including pH of the solutions, amounts of complexing reagent, eluent type, sample volume, flow rates of solutions, and matrix ions were examined for quantitative recoveries of the studied analyte ions. The retained metal ions were eluted by 2 M HNO3. The LOD values for the analytes were in the range of 0.7-4.4 microg/mL. Natural water samples and standard reference materials were analyzed by the presented method. 相似文献
17.
A flow injection system was developed for on-line sorbent extraction preconcentration and flame atomic absorption spectrometric
determination of cadmium in natural water samples. The non-charged cadmium complex with diethyl-dithiophosphate (DDPA) was
formed on-line in 0.1 mol L−1 HNO3 and retained on the hydrophobic poly-chlorotrifluoroethylene (PCTFE) sorbent material. The adsorbed complex was eluted with
isobutyl methylketone (IBMK) and injected directly into the nebulizer via a flow compensation unit. All major chemical and
flow parameters affecting the complex formation adsorption and elution as well as interference were studied and optimized.
By processing 2.4 mL of sample, the enhancement factor was 39 and the sampling frequency was 50 h−1. For 30 s preconcentration time the detection limit was 0.3 μg L−1 and the relative standard deviation at 5.0 μg L−1 Cd concentration level was 2.9%. The calibration curve was linear in the range 0.8–40.0 μg L−1. The accuracy of the method was estimated by analyzing a certified reference material NIST-CRM 1643d (Trace elements in water).
Good recoveries were obtained for spiked natural-water and waste-water samples.
Correspondence: Aristidis N. Anthemidis, Laboratory of Analytical Chemistry, Department of Chemistry, Aristotle University,
GR-Thessaloniki 54124, Greece 相似文献
18.
A sensitive solid-phase extraction technique (SPE) for the enrichment of Fe(III), Co(II), Mn(II) and Cr(III) prior to atomic absorption spectrometric analysis is described. Escherichia coli immobilized on Amberlite XAD-4 was used as a solid-phase extractor. The effects of the pH, amount of solid-phase, eluent type and volume of the sample solution on the recovery of the metal ions were investigated. The effect of diverse ions was also investigated. The recoveries of Fe(III), Co(II), Mn(II) and Cr(III) under the optimum conditions were found to be 99 +/- 2, 99 +/- 3, 98 +/- 2, 98 +/- 3%, respectively, at the 95% confidence level. The detection limits of the metal ions were found as to be 2.4, 3.8, 1.3 and 1.7 ng ml(-1) for Fe(II), Co(II), Mn(II) and Cr(III) respectively, by applying a preconcentration factor of 25. The proposed enrichment method was applied to the determination of analytes in Atatürk Dam water samples, and alloy samples (RSD < 5%). The accuracy of the method was verified on certified alloy samples (NBS SRM 85b and NBS SRM 59a). The analytes were determined with a relative error lower than 5% in water and alloy samples. 相似文献
19.
A robust flow injection (FI) on-line liquid-liquid extraction (LLE) preconcentration/separation system associated with a newly designed gravitational phase separator, coupled to flame atomic absorption spectrometry (FAAS) was developed. The performance of the system was illustrated for cadmium determination at the μg l−1 level. The non-charged cadmium complex with ammonium pyrrolidine dithiocarbamate (APDC) was extracted on-line into isobutyl methyl ketone (IBMK). The organic phase was effectively separated from a large volume of aqueous phase and is led into a 100 μl loop of an injection valve before its introduction into the nebulizer. The system was optimized and offered good performance characteristics with unlimited life time of phase separator, greater flow rate ratios and improved flexibility, as compared with other solvent extraction preconcentration systems. With a sampling frequency of 33 h−1, the enhancement factor was 155, the detection limit was 0.02 μg l−1, the relative standard deviation was 3.2% at 2.0 μg l−1 Cd concentration level and the calibration curve was linear over the concentration range 0.06-6.0 μg l−1. The accuracy of the proposed method was evaluated by analyzing a certified reference material of water and by recovery measurements on spiked samples. Finally, it was successfully applied to the analysis of tapwater, river and seawater samples. 相似文献
20.
A preconcentration method for manganese determination by sequential injection cloud point extraction with subsequent detection by flame atomic absorption spectrometry (FAAS) has been developed. The enrichment of Mn was performed after a preliminary on-line cloud point extraction and entrapment of manganese-containing surfactant aggregated within a minicolumn packed with cotton. The laboratory-made reagent 4-(5′-bromo-2′-thiazolylazo)orcinol (Br-TAO) and the surfactant Triton X-114 were used for cloud point extraction. The manganese ions were eluted with sulphuric acid solution and directly introduced into the FAAS. Chemical and flow variables affecting the preconcentration were studied. Using a sample volume of 2.80 mL the limit of detection and enrichment factor were calculated to be 0.5 μg L−1 and 14, respectively. The sample frequency is 48 h−1, considering a total run cycle of 75 s. The accuracy of the proposed method has been demonstrated by the analysis of the certified reference biological materials rice flour and tomato leaves. The method has been applied to determination of manganese in food samples. 相似文献