首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
Summary A method for determination of trace amounts of the pesticides tebufenpyrad and oxadiazon, previous solid-phase microextraction (SPME), was developed using gas chromatographymass spectrometry and selected ion monitoring (GC-MS; SIM). Both pesticides were extracted with a fused silica fiber coated with 100 μm polydimethylsiloxane. The effects of pH ionic strength, sample volume, extraction and desorption times as well as extraction temperature were studied. The linear concentration range of application was 0.5–250 ng mL−1 for both compounds, with a detection limit of 0.06 ng mL−1 for tebufenpyrad and 0.02 ng mL−1 for oxadiazon. SPME-GC-MS analysis yielded good reproducibility (RSD between 7.5–10.1%). It was used to check the eventual existence of tebufenpyrad and oxadiazon above this limit in water and soil samples from Granada (Spain) as well as in human urine samples. The method validation was completed with spiked matrix samples. It can be applied as a monitoring tool for water, soil and urine in the investigation of environmental and occupational exposure to tebufenpyrad and oxadiazon.  相似文献   

2.
A method for the determination of the organic acids directly in the urine employing derivatization with trimethyloxonium tetrafluoroborate as a methylating agent and sequential extraction by head space and direct immersion/solid phase microextraction is reported. Furoic acid, hippuric acid, methylhippuric acid, mandelic acid, phenylglyoxylic acid and trans, trans muconic acid contained in urine and proposed by the American Conference of Governmental Industrial Hygienists as biological exposure indices were determined after a fast and economically convenient preparation step and sensitive gas chromatography-ion trap-mass spectrometry/tandem mass spectrometry analysis. Urine is rather a complex sample and hence the acquisition method required specific GC-MS instrumentation capable of supporting the changeover, fully automated during a single chromatographic separation, from mass to tandem mass spectrometry and both chemical and electron ionization modes. The automation of the analytical method provides a number of advantages, including reduced analysis time for both routine analysis and method development, and greater reproducibility. The equilibrium and kinetics of this substances vs head space/direct immersion-solid phase microextraction were investigated and evaluated theoretically.  相似文献   

3.
This work describes a sensitive method for determining cholesterol in human hair using GC-MS. In this study, we used a very small amount of hair, only 1 mg, to quantify cholesterol. We also can achieve more effective purification and a good recovery over 92% with solid-phase extraction using an Oasis HLB cartridge. The intra-day and inter-day precision and accuracy values were less than 7.08%. Cholesterol was determined to be in the range of 355-1693 microg/g in healthy human hair. We tested the concentration correlation between the serum and hair to examine the feasibility of using the hair cholesterol level as an index of the serum cholesterol level. The correlation between the serum cholesterol was 0.86 (r-value) in patients with hypercholesterolemia. This finding indicates that, in the clinical field, hair could replace serum in cholesterol level measurement.  相似文献   

4.
A method using headspace solid-phase microextraction (HS-SPME) then gas chromatography–mass spectrometry with selected ion monitoring (GC–MS, SIM) has been developed for determination of trace amounts of the fungicides pyrimethanil and kresoxim-methyl in soil and humic materials. Both fungicides were extracted on to a fused-silica fibre coated with 85 m polyacrylate (PA). Response-surface methodology was used to optimise the experimental conditions. For soil samples the linear dynamic range of application was 0.004–1.000 g g–1 for pyrimethanil and 0.013–1.000 g g–1 for kresoxim-methyl. The detection limits were 0.001 g g–1 and 0.004 g g–1 for pyrimethanil and kresoxim-methyl, respectively. HP-SPME–GC–MS analysis was highly reproducible—relative standard deviations (RSD) were between 6.7 and 12.2%. The method was validated by analysis of spiked matrix samples and used to investigate the presence of pyrimethanil and kresoxim-methyl above the detection limits in soil and humic materials.  相似文献   

5.
Zhou Y  Xu D  Chen D  Zhang Z  Zheng X  Fang E 《色谱》2011,29(7):656-661
基于固相微萃取-气相色谱(SPME-GC)建立了检测茶叶中氟虫腈及其代谢物(脱亚硫酰基氟虫腈、硫化氟虫腈、氟虫腈砜、酰胺氟虫腈)残留的分析方法。实验中采用85 μm聚丙烯酸酯(PA)萃取头,萃取温度为60 ℃,萃取缓冲体系的pH值为9。当添加水平为2~10 μg/kg时,回收率在71.2%~109.3%之间,相对标准偏差(RSD)在1.2%~7.1%之间。方法的检出限(LOD)和定量限(LOQ)分别在0.3~1.2 μg/kg和1.0~4.0 μg/kg之间。对所建立的方法采用气相色谱-质谱(GC-MS)进行确证,结果令人满意。本方法灵敏度、精密度和LOD均符合残留分析要求,具有快速、灵敏度高的特点,适合于茶叶中氟虫腈及其代谢物残留的痕量分析。  相似文献   

6.
林兴桃  王小逸  赵靖强 《色谱》2016,34(5):528-532
建立了固相萃取-气相色谱-质谱测定尿液中邻苯二甲酸单酯和双酯的分析方法。尿液经 β-葡萄糖苷酸酶酶解后进行固相萃取净化,用乙腈、乙酸乙酯和乙醚-正己烷(1: 19, v/v)分别洗脱,合并洗脱液,氮气吹干后,用N,O-双三甲基硅基三氟乙酰胺(BSTFA)对邻苯二甲酸单酯进行硅烷化处理,使用气相色谱-质谱法检测。邻苯二甲酸单酯和双酯的线性范围为5~1000 μ g/L,检出限为0.3~1.1 μ g/L,回收率为77.9%~97.7%,相对标准偏差为3.7%~10.9%。应用该方法对50份尿液进行检测,检出邻苯二甲酸二(2-乙基己基)酯(DEHP)等7种邻苯二甲酸单酯和双酯类物质,平均质量浓度为6.0~142.7 μ g/L。该方法准确、可靠、灵敏度高,适用于尿液中邻苯二甲酸单酯和双酯的同时测定。  相似文献   

7.
In the present work, a method was developed and optimized aiming at the determination of anatoxin-a in environmental water samples. The method is based on the direct derivatization of the analyte by adding hexylchloroformate in the alkalinized sample (pH = 9.0). The derivatized anatoxin-a was extracted by a solid-phase microextraction (SPME) procedure, submersing a PDMS fiber in an amber vial for 20 min under magnetic stirring. GC-MS was used to identify and quantify the analyte in the SIM mode. Norcocaine was used as internal standard. The following ions were chosen for SIM analyses (quantification ions in italics): anatoxin-a: 191, 164, 293 and norcocaine: 195, 136, 168. The calibration curve showed linearity in the range of 2.5-200 ng/mL and the LOD was 2 ng/mL. This method of SPME and GC-MS analysis can be readily utilized to monitor anatoxin-a for water quality control.  相似文献   

8.
Wang G  Tang H  Chen D  Feng J  Li L 《色谱》2012,30(2):135-140
建立了香水中5种合成麝香的顶空固相微萃取-气相色谱-质谱联用分析方法。实验选用65 μm的聚二甲基硅氧烷-二乙烯基苯(PDMS-DVB)萃取纤维,在磁力搅拌600 r/min条件下,考察了萃取温度、平衡时间、萃取时间、解吸时间、进样口温度和盐效应6个方面对实验结果的影响。优化后的条件为: 10 mL顶空瓶中加入适量用水稀释过的样品,于60 ℃平衡3 min后,顶空萃取20 min,随即插入气相色谱进样口,于250 ℃解吸3 min进行定性、定量分析。5种合成麝香在0.05~1.00 μg/g范围内线性关系良好,检出限(LOD)为0.6~2.1 ng/g。空白样品在3个浓度加标水平下(0.05, 0.50, 1.00 μg/g)的回收率为82.0%~103.3%,相对标准偏差(RSD)为1.8%~9.4%。本方法简便、准确、快速、灵敏,适用于香水中合成麝香的分析检验工作。  相似文献   

9.
When cocaine is smoked, a pyrolytic product, methyl ecgonidine (anhydroecgonine methyl ester), is also consumed with the cocaine. The amount of methyl ecgonidine formed depends on the pyrolytic conditions and composition of the illicit cocaine. This procedure describes detection of cocaine and 10 metabolites--cocaethylene, nor-cocaine, nor-cocaethylene, methyl ecgonine, ethyl ecgonine, benzoylecgonine, nor-benzoylecgonine, m-hydroxybenzoylecgonine, p-hydroxybenzoylecgonine and ecgonine--in blood and urine. In addition, the detection of pyrolytic methyl ecgonidine and three metabolites--ecgonidine (anhydroecgonine), ethyl ecgonidine (anhydroecgonine ethyl ester) and nor-ecgonidine (nor-anhydroecgonine)--are included. The newly described metabolites, ethyl ecgonidine and nor-ecgonidine, were synthesized and characterized by gas chromatography-mass spectrometry (GC-MS). All 15 compounds were extracted from 3 mL of blood or urine by solid-phase extraction and identified by a GC-MS method. The overall recoveries were 49% for methyl ecgonine, 35% for ethyl ecgonine, 29% for ecgonine and more than 83% for all other drugs. The limits of detection were between 0.5 and 4.0 ng/mL except for ecgonine, which was 16 ng/mL. Linearity for each analyte was established and in all cases correlation coefficients were 0.9985-1.0000. The procedure was applied to examine the concentration profiles of analytes of interest in post-mortem (PM) blood and urine, and in urine collected from living individuals (LV). These specimens previously were shown to be positive for the cocaine metabolite, benzoylecgonine. Ecgonidine, the major metabolite of methyl ecgonidine, was present in 77% of PM and 88% of the LV specimens, indicating smoking as the major route of cocaine administration. The new pyrolytic metabolites, ethyl ecgonidine and nor-ecgonidine, were present in smaller amounts. The urine concentrations of nor-ecgonidine were 0-163 ng/mL in LV and 0-75 ng/mL in PM specimens. Ethyl ecgonidine was found only in PM urine at concentrations 0-39 ng/mL. Ethanol-related cocaine metabolites, ethyl ecgonine or cocaethylene, were present in 69% of PM and 53% of cocaine-positive LV specimens, implying alcohol consumption with cocaine use. The four major metabolites of cocaine--benzoylecgonine, ecgonine, nor-benzoylecgonine and methyl ecgonine--constituted approximately 88 and 97% of all metabolites in PM and LV specimens, respectively. The concentrations of nor-cocaine and nor-cocaethylene were consistently the lowest of all cocaine metabolites. At benzoylecgonine concentrations below 100 ng/mL, ecgonine was present at the highest concentrations. In 20 urine specimens, benzoylecgonine and ecgonine median concentrations (range) were 54 (0-47) and 418 ng/mL (95-684), respectively. Therefore, detection of ecgonine is advantageous when benzoylecgonine concentrations are below 100 ng/mL.  相似文献   

10.
As a part of our search for environmentally friendly solvents to extract the active components of medicinal plants, two sampling techniques, supercritical fluid extraction (SFE) using CO(2) and solid-phase microextraction (SPME) were compared for their efficacy in the analysis of volatiles rhizome components emitted from the medicinal herbs Angelica gigas NAKAI (Korean danggui), Angelica sinensis (Chinese danggui), and Angelica acutiloba (Japanese danggui). A total of 54 compounds released from all of these varieties of Angelica rhizomes were separated and identified by gas chromatography-mass spectrometry (GC-MS). The composition of supercritical extracts from these plants was very different from the solid-phase microextraction products. More compounds were detected by SPME-GC-MS (41) than by SFE-GC-MS (17). The results of these analyses suggest that SFE may be useful for detecting the main components, decursinol angelate and decursin in Korean danggui, and butylidene dihydro-phthalide in both Chinese and Japanese danggui, whereas the results for SPME did not. The SFE method required specialized instrumentation, required little time to prepare the sample, and had a small sample size and no organic solvent. In sum, these results suggest that SFE is useful for extracting the volatile main components of danggui cultivars. Its simplicity, low cost and speed may allow SPME to increase the recovery of volatile components in general without disturbing the main components of the plant.  相似文献   

11.
Summary A capillary gas chromatography method for the analysis of inositol isomers and arabitol (extendable to threitol and adonitol) is described and applied to urine after derivatization. The single ion monitoring technique allows a notable improvement in sensitivity and selectivity.  相似文献   

12.
高吭  刘雅珣  柯威  刘凯  倪浏阳  陶涛 《色谱》2020,38(11):1348-1354
公安机关用胶体金尿检法对海洛因滥用者的检测常常受到阿片类镇咳药的干扰,使用传统液-液提取法进行实验室检验,操作效率低,灵敏度不高,无法满足公安机关打击涉毒案件的需要。为此,该研究建立了尿液中吗啡、O6-单乙酰吗啡、可待因和乙酰可待因4种阿片类物质的固相萃取和衍生化技术结合气相色谱-质谱联用(GC-MS)同时检测方法。尿样用磷酸盐缓冲液调节至pH=6后,经MCX固相萃取柱净化,用N-甲基-N-(三甲基硅烷基)三氟乙酰胺(MSTFA)对吗啡、O6-单乙酰吗啡、可待因进行衍生化,供GC-MS检测。考察了上样和洗脱流速、淋洗液中甲酸体积分数、洗脱液中氨水体积分数、3%(v/v)甲酸甲醇淋洗液体积和固相萃取柱吹干时间对萃取效果的影响。确定上样和洗脱流速1.0 mL/min,淋洗液中甲酸体积分数3%,洗脱液中氨水体积分数5%, 3%(v/v)甲酸甲醇淋洗液体积1 mL,吹干时间1 min为最佳条件。在此条件下,4种阿片类物质在0.02~0.8μg/mL范围内线性关系良好(r2≥0.998),检出限(LOD)为0.001 6~0.00...  相似文献   

13.
采用顶空固相微萃取和气相色谱 质谱单离子监测技术,以己二酸二(1 丁基戊基)酯为内标,对水中的己二酸二乙酯、己二酸二异丁酯、己二酸二丁酯、己二酸二(2 丁氧基乙基)酯、己二酸二(乙基己基)酯进行了测定,考察了盐效应、萃取温度、萃取时间和热解吸时间等因素对方法灵敏度的影响。该方法对5种己二酸酯的检测限量为0.0220~5.49μg L,回收率为86.9%~102.0%,相对标准偏差为1.5%~7.3%。  相似文献   

14.
研究了固相微萃取(SPME) 气相色谱 质谱联用(GC MS)同时测定环境水样中二嗪农、甲基对硫磷、对硫磷和水胺硫磷4种有机磷农药(OPPs)的分析方法。选择聚丙烯酸酯(PA)萃取纤维,对SPME的条件如萃取时间、萃取溶液的pH值和离子强度、解吸温度、解吸时间和GC MS的条件进行了优化。对二嗪农和水胺硫磷方法线性范围为0.001~10μg L,对甲基对硫磷和对硫磷方法线性范围为0.001~100μg L。二嗪农、甲基对硫磷、对硫磷、水胺硫磷的检出限分别为0.015,0.020,0.013和0.039μg L。分析加标自来水、矿泉水和湖水样品,回收率在89.0%~102%之间,RSD在2.1%~14.1%之间。适合于环境水样中痕量OPPs的快速分析。  相似文献   

15.
A simple and sensitive method was developed for the simultaneous separation and determination of trace earthy-musty compounds including geosmin, 2-methylisoborneol, 2-isobutyl-3-methoxypyrazine, 2-isopropyl-3-methoxypyrazine, 2,3,4-trichloroanisole, 2,4,6-trichloroanisole, and 2,3,6-trichloroanisole in water samples. This method combined headspace solid-phase microextraction (HS-SPME) with gas chromatography-mass spectrometry and used naphthalene-d(8) as internal standard. A divinylbenzene/carboxen/polydimethylsiloxane fiber exposing at 90°C for 30 min provided effective sample enrichment in HS-SPME. These compounds were separated by a DB-1701MS capillary column and detected in selected ion monitoring mode within 12 min. The method showed a good linearity from 1 to 100 ng L(-1) and detection limits within (0.25-0.61 ng L(-1)) for all compounds. Using naphthalene-d(8) as the internal standard, the intra-day relative standard deviation (RSD) was within (2.6-3.4%), while the inter-day RSD was (3.5-4.9%). Good recoveries were obtained for tap water (80.5-90.6%), river water (81.5-92.4%), and lake water (83.5-95.2%) spiked at 10 ng L(-1). Compared with other methods using HS-SPME for determination of odor compounds in water samples, this present method had more analytes, better precision, and recovery. This method was successfully applied for analysis of earthy-musty odors in water samples from different sources.  相似文献   

16.
A method for the determination of trace amounts of the insecticide fipronil was developed using solid-phase microextraction-gas chromatography-mass spectrometry and selected ion monitoring. Fipronil was extracted with a fused-silica fiber coated with 85 microm polyacrylate. The effects of pH, ionic strength, sample volume, extraction and desorption times as well as the extraction temperature were studied. Lindane was used as an internal standard. The linear concentration range of application was 0.3-100 ng ml(-1) of fipronil, with a relative standard deviation of 9.5% (for a level of 50 ng ml(-1)) and a detection limit of 0.08 ng ml(-1). The method was applied to check the eventual existence of fipronil above this limit in water and soil samples from Granada (Spain) as well as in human urine samples. The method validation was completed with spiked matrix samples. The method can be applied as a monitoring tool for water, soil and urine, in the investigation of environmental and occupational exposure to fipronil.  相似文献   

17.
徐仿敏  李海波  魏万里  刘凌云  李强 《色谱》2018,36(10):1067-1072
建立一种基于可变亲水性溶剂的液液微萃取-气相色谱-质谱联用法,快速检测尿液中2′-氯地西泮。对影响萃取效率的可变亲水性溶剂的种类、用量、转换条件、萃取时间等因素进行考察和优化。在最佳实验条件下,尿液中2′-氯地西泮的线性范围为0. 025~2. 5 mg/L,检出限为0. 007 mg/L,日内和日间回收率为76. 5%~90. 3%,日内和日间精密度为3. 3%~6. 5%。该方法具有良好的线性、检出限、回收率和精密度,有较好的应用价值,可应用于尿液中2′-氯地西泮的分析。  相似文献   

18.
气相色谱-质谱法分析化妆品中16种香精香料   总被引:4,自引:0,他引:4  
王超  王星  季美琴 《分析试验室》2006,25(11):118-122
建立了用毛细管气相色谱质谱测定化妆品中16种香精香料的方法.样品用甲醇超声提取,经高速冷冻离心,清液经干燥脱水过0.5 μm滤膜过滤,直接注入气相色谱质谱进行分析.经过GC-MS分析,用选择离子和保留时间定性,外标法定量.16种香精香料的回收率为:82.3%~108.2%,精密度为(以相对标准偏差表示):1.6%~4.7%,检出限均为10 mg/kg.该方法准确度和灵敏度高,样品用量少,前处理简单,可同时测定化妆品中16种香精香料.  相似文献   

19.
The aroma profile of cocoa products was investigated by headspace solid-phase micro-extraction (HS-SPME) combined with gas chromatography–mass spectrometry (GC–MS). SPME fibers coated with 100 μm polydimethylsiloxane coating (PDMS), 65 μm polydimethylsiloxane/divinylbenzene coating (PDMS-DVB), 75 μm carboxen/polydimethylsiloxane coating (CAR-PDMS) and 50/30 μm divinylbenzene/carboxen on polydimethylsiloxane on a StableFlex fiber (DVB/CAR-PDMS) were evaluated. Several extraction times and temperature conditions were also tested to achieve optimum recovery. Suspensions of the samples in distilled water or in brine (25% NaCl in distilled water) were investigated to examine their effect on the composition of the headspace. The SPME fiber coated with 50/30 μm DVB/CAR-PDMS afforded the highest extraction efficiency, particularly when the samples were extracted at 60 °C for 15 min under dry conditions with toluene as an internal standard. Forty-five compounds were extracted and tentatively identified, most of which have previously been reported as odor-active compounds. The method developed allows sensitive and representative analysis of cocoa products with high reproducibility. Further research is ongoing to study chocolate making processes using this method for the quantitative analysis of volatile compounds contributing to the flavor/odor profile.  相似文献   

20.
This paper describes a rapid and solvent-free method, microwave-assisted headspace solid-phase microextraction (MA-HS-SPME), for the extraction of six commonly used synthetic polycyclic musks: galaxolide (HHCB), tonalide (AHTN), celestolide (ADBI), traseolide (ATII), cashmeran (DPMI) and phantolide (AHMI) from water samples prior to their determination using gas chromatography-mass spectrometry (GC-MS). The effects of various extraction parameters for the quantitative extraction of these analytes by MA-HS-SPME were systematically investigated and optimized. The analytes in a 20-mL water sample (in a 40-mL sample-vial containing 4 g of NaCl) were efficiently extracted by a polydimethylsiloxane-divinylbenzene (PDMS-DVB) fiber placed in the headspace when the system was microwave irradiated at 180 W for less than 4 min. The limits of detection (LODs) ranged from 0.05 to 0.1 ng/L, and the limits of quantification (LOQs) were less than 0.2 ng/L. A preliminary analysis of wastewater samples revealed that HHCB and AHTN were the two most commonly detected synthetic polycyclic musks; using a standard addition method, their concentration were determined to range from 1.2 to 37.3 ng/L with relative standard deviation (RSD) ranging from 2 to 6%. The results obtained using this approach are better than those from the conventional oil-bath HS-SPME.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号