首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 750 毫秒
1.
Thionins belong to a family of cysteine‐rich, low‐molecular‐weight (~5 KDa) biologically active proteins in the plant kingdom. They display a broad cellular toxicity against a wide range of organisms and eukaryotic cell lines. Thionins protect plants against different pathogens, including bacteria and fungi. A highly selective solid‐phase extraction method for plant thionins is reported deploying aluminum silicate (3:2 mullite) powder as a sorbent in extraction columns. Mullite was shown to considerably improve selectivity compared to a previously described zirconium silicate embedded poly(styrene‐co‐divinylbenzene) monolithic polymer. Due to the presence of aluminum(III), mullite offers electrostatic interactions for the selective isolation of cysteine‐rich proteins. In comparison to zirconium(IV) silicate, aluminum(III) silicate showed reduced interactions towards proteins which resulted into superior washings of unspecific compounds while still retaining cysteine‐rich thionins. In the presented study, European mistletoe, wheat and barley samples were subjected to solid‐phase extraction analysis for isolation of viscotoxins, purothionins and hordothionins, respectively. Matrix‐assisted laser desorption/ionization time of flight mass spectroscopy was used for determining the selectivity of the sorbent toward thionins. The selectively retained thionins were quantified by colorimetric detection using the bicinchoninic acid assay. For peptide mass‐fingerprint analysis tryptic digests of eluates were examined.  相似文献   

2.
We report on a new method for the selective extraction of the antibiotic sulfamethoxazole (SMO) in milk that is making use of a molecularly imprinted polymer (MIP) monolith as the sorbent. The monolith was synthesized in the tip of a micropipette using SMO as the template and a combination of acrylamide and 4-vinylpyridine as the co-functional monomers. The monolith was connected to syringes in different sizes and used for microextraction without any other treatment and showed high selectivity and enrichment ability for SMO. It was applied to the selective extraction and sensitive determination of SMO in milk. The linear range is from 5–600?μg?L?1, the correlation coefficient (r2) is 0.9984, and the detection limit (at S/N?=?3) is 1?μg?L?1. Recoveries range from 93.6 to 101.7?%, with relative standard deviations of <6.1?%.
Figure
A method for the selective extraction of sulfamethoxazole (SMO) in milk based on molecularly imprinted polymer (MIP) monolith as the sorbent was developed. The linear ranges were 5–600?μg/L for SMO in milk. High recoveries of 93.6?~?101.7?% from milk were obtained with relative standard deviations less than 6.1?%.  相似文献   

3.
We have developed two methods for the quantitation of gabapentin in human plasma. They are based on capillary electrophoresis with laser-induced fluorescence detection (CE-LIF) with and without solid-phase extraction (SPE) and the derivatizing reagent 5-(4,6-dichlorotriazinyl)amino fluoresencin. The conditions for derivatization, separation and extraction were investigated in detail, and the optimal labeling conditions include a temperature of 40?°C, a reaction time of 30?min, and the use of a borate buffer of pH 9.0 as the reaction medium. A borate buffer of pH 9.2 served as a background electrolyte for CE separations. The CE-LIF and SPE-CE-LIF methods have linear ranges of 5–200?nmol?L?1 and 0.2–10?nmol?L?1, respectively, and the limits of detection are 0.5 and 0.02?nmol?L?1, respectively. The SPE-CE-LIF method was successfully applied to the determination of gabapentin in blood plasma samples.
Figure
Two methods have been developed for the quantization of gabapentin (GBP) in human plasma. They are based on capillary electrophoresis-laser induced fluorescence detection (CE-LIF) with and without solid-phase extraction (SPE) and the derivatizing reagent 5-(4,6-dichlorotriazinyl)aminofluorescein.  相似文献   

4.
A comprehensive method for the analysis of 11 target pharmaceuticals representing multiple commonly used therapeutic classes was developed for biological tissues (fish), reclaimed water, and the surface water directly affected by irrigation with reclaimed water. One gram of fish tissue homogenate was extracted by accelerated solvent extraction with methylene chloride followed by mixed-mode cation exchange solid phase extraction (SPE) cleanup and analyzed by liquid chromatography-tandem mass spectrometry. Compared to previously reported methods, the protocol produces cleaner extracts resulting in lower method detection limits. Similarly, an SPE method based on Oasis HLB cartridges was used to concentrate and cleanup reclaimed and surface water samples. Among the 11 target compounds analyzed, trimethoprim, caffeine, sulfamethoxazole, diphenhydramine, diltiazem, carbamazepine, erythromycin, and fluoxetine were consistently detected in reclaimed water. Caffeine, diphenhydramine, and carbamazepine were consistently detected in fish and surface water samples. Bioaccumulation factors for caffeine, diphenhydramine, and carbamazepine in mosquito fish (Gambusia holbrooki) were calculated at 29?±?26, 821?±?422, and 108?±?144, respectively. This is the first report of potential accumulation of caffeine in fish from a water body directly influenced by reclaimed water.
Figure
The pharmaceuticals detected in reclaimed water and the fresh water directly affected by reclaimed water.  相似文献   

5.
We have developed a new method for solid phase extraction (SPE) and preconcentration of trace amounts of cadmium and zinc using cross linked chitosan that was functionalized with 2-aminopyridine-3-carboxy acid. Analytical parameters, sample pH, effect of flow rate, sample volume, and concentration of eluent on column SPE were investigated. The effect of matrix ions on the recovery of cadmium and zinc has been investigated and were found not to interfere with preconcentration. Under the optimum experimental conditions, the preconcentration factors for Cd(II) and Zn(II) were found to be 90. The two elements were quantified via atomic absorption spectrometry. The detection limits for cadmium and zinc are 21 and 65?ng?L?1, respectively. The method was evaluated by analyzing a certified reference material (NIST 1643e; water) and has been successfully applied to the analysis of cadmium and zinc in environmental water samples.
Figure
A simple and sensitive solid phase extraction method for the preconcentration of Cd(II) and Zn(II) in environmental samples using cross linked chitosan functionalized with 2-aminopyridine-3-carboxylic acid was developed. The metal ions enriched by functionalized chitosan were eluted with acid and determined by AAS.  相似文献   

6.
This work describes the characterization of a solid-phase extraction (SPE) and liquid-chromatography-tandem mass spectrometry-based method for the analysis of acrylamide (AA) in complex environmental waters. The method involved the SPE of AA using activated carbon, and the AA was detected with tandem mass spectrometry after separating on an ion exclusion high-performance liquid chromatography column. The method incorporated two labeled AA standards for quantification using isotope dilution and to assess absolute extraction recovery. The method was evaluated for inter- and intra-day precision and accuracy. The method was both accurate (i.e., <30 % error) and precise (i.e., <20 % relative standard deviation), with absolute extraction recoveries averaging 37 %. The mass spectrometry provided excellent sensitivity, with instrumental limits of detection and quantitation values of 23 and 75 pg, respectively. The method detection limit was determined to be 0.021 μg/L. The analysis of AA was successfully performed in real-world samples that contained total dissolved solids concentrations ranging from 23,600 to 297,000 mg/L and AA concentrations ranging from 0.082 to 1.0 μg/L.
Figure
Product ion spectra of, from top to bottom, acrylamide, acrylamide-1-13C, and acrylamide-2,3,3-d3. The predominant peak in each spectrum was used for quantitation  相似文献   

7.
We have modified gold nanoparticles (AuNPs) with triazole acetamide to obtain a material for the sensitive and selective colorimetric determination of iodide. The functionalized AuNPs were prepared by a reductive single chemical step using a Cu(I)-catalyzed click reaction. The presence of iodide ions induces the aggregation of these AuNPs and results in a color change from wine-red to purple. The iodide-induced aggregation can be detected visually with bare eyes, but also by photometry. The detection limit is as low as 15 nM. The method displays excellent selectivity for iodide over other anions due to the selective interaction with the amido groups of the triazole. The method was applied to the determination of iodide in spiked lake waters.
Figure
New triazole acetamide functionalized gold nanoparticles (ATTP-AuNPs) for sensitive and selective colorimetric detection of I? were developed. ATTP-AuNPs showed excellent selectivity toward I? due to the interaction between the amide groups of ATTP and I?.  相似文献   

8.
We describe molecularly imprinted microspheres (MIMs) for the selective extraction of melamine from milk. The MIMs were made from melamine as the template molecule, methacrylic acid as the functional monomer, and ethylene glycol dimethacrylate as the linking agent. The MIMs were synthesized by suspension polymerization and characterized by rebinding experiments. They displayed high adsorption capacity, fast rebinding kinetics, and highly specific rebinding of melamine. The imprinting factor is 4.1. Scatchard analysis revealed a one-type rebinding behavior, the dissociation constant and maximum rebinding capacity being 37.59 g L?1 and 30.85 μmol g?1, respectively. The MIMs exhibited a 25% cross-reactivity towards atrazine, but less than 3.0% towards prometryn, clenbuterol and metronidazole. In addition, a MIM-based solid phase extraction (MISPE) column for melamine was prepared by packing MIMs into a common SPE cartridge. The MISPE extraction gave recoveries of 89.8 to 100.6% of melamine, with relative standard deviations of 5.9 to 7.5%. There was no significant loss of rebinding capacity after more than 60 repeated uses, thus demonstrating the high stability of the MISPE column. The MSPE column also was applied to the extraction of melamine from spiked liquid and powdered milk with satisfying accuracy and precision.
Figure
The melamine molecularly imprinted microsphere (MIMs) prepared by suspension polymerization displayed high adsorption capacity quick rebinding kinetic and highly specific rebinding. The MIMs-based solid phase extraction (MISPE) column was prepared by packing MIMs into a common SPE cartridge. The recoveries of MISPE for extracting melamine from milk samples were 76.26–90.95%.  相似文献   

9.
A solid phase extraction method is presented for the selective preconcentration and/or separation of trace Pb(II) on multiwalled carbon nanotubes modified with 2-aminobenzothiazole. Inductively coupled plasma optical emission spectrometry was used for detection. The effects of pH, shaking time, sample flow rate and volume, elution condition and interfering ions were examined using batch and column procedures. An enrichment factor of 100 was accomplished. Common other ions do not interfere in both the separation and determination. The maximum adsorption capacity of the sorbent at optimum conditions is 60.3?mg?g?1 of Pb(II), the detection limit (3??) is 0.27?ng?mL?1, and the relative standard deviation is 1.6% (n?=?8). The method was validated using a certified reference material, and has been applied to the determination of trace Pb(II) in water samples with satisfactory results.
Figure
2-Aminobenzothiazole modified multiwalled carbon nanotubes has been developed to separate and concentrate trace Pb(II) from aqueous samples. Parameters that affect the sorption and elution efficiency were studied in batch and column modes, and the new sorbent (MWCNTs-ABTZ) presents high selectivity and adsorption capacity for the solid phase extraction of trace Pb(II).  相似文献   

10.
We report on a method for selective extraction and backextraction for the ultra-sensitive determination of Pd(II). Magnetite nanoparticles modified with sodium dodecyl sulfate were used to extract Pd(II) as its green 1-(2-pyridylazo)-2-naphtholate complex prior to zero- and first-derivative spectrophotometric determination at 659 and 681?nm, respectively. A sample volume of 70?mL was backextracted with 0.50?mL of n-butanol in a 3-phasic system. The effects of reaction time and the other variables were optimized. The enrichment factor is 134 and the calibration plots are linear in the range from 2 to 90?ng?mL-1 of Pd(II). The detection limit is 0.3?ng?mL-1 and the relative standard deviations and recoveries at levels of 10 and 72?ng?mL-1 of Pd(II) are in the range from 1.1?C4.9%, and from 98.5?C102.6%, respectively. Most ions do not significantly interfere. The method was successfully applied to the determination of Pd(II) in water and urine samples, alloys, and palladium catalysts.
Figure
The new SPE method was developed for the preconcentration-spectrophotometric determination of palladium using dodecyl sulfate coated magnetite nanoparticles as adsorbrnt and then backextraction by a low volume of n-butanol in a novel 3-phasic backextraction. The established SPE method proved to be efficient for palladium determination and provided satisfactory recoveries and precisions.  相似文献   

11.
We have developed a rapid, selective and efficient method for dispersive solid-phase microextraction (DSPME) using microbeads of a molecularly imprinted polymer (MIP). It enables the pre-concentration of sulfamethazine and sample clean-up prior to capillary electrophoresis with UV detection. The microbeads were synthesized via precipitation polymerization using sulfamethazine, methacrylic acid and ethylene glycol dimethacrylate (EGDMA) as the template molecule, the functional monomer and the cross-linking monomer, respectively. Characterization by SEM displayed the high uniformity and dispersibility of the MIP microbeads. The adsorption and desorption of sulfamethazine and the parameters for CE were optimized to result in a limit of detection of 1.1?μg?L?1, which is 373-fold lower than that of direct CE detection. The equilibration time of extraction was reduced to 5?min, and the selectivity of the microbeads was significantly improved compared to the non-imprinted polymer. The method was successfully applied to the determination of trace sulfamethazine in several milk samples, with recoveries in the range of 89?% to 110?%.
Figure
A novel, rapid, selective and efficient dispersive solid-phase microextraction approach using molecularly imprinted polymer microbeads was developed for pre-concentration of sulfamethazine and sample clean-up prior to capillary electrophoresis detection.  相似文献   

12.
Perfluorinated carboxylic acids (PFCAs) represent an important group of persistent perfluorinated organic compounds commonly determined in environmental and biological samples. A reversed-phase HPLC method was developed based on derivatization of the PFCAs with the commercially available fluorescent reagent 3-bromoacetyl coumarin. The method was optimized and this resulted in the efficient separation of PFCAs containing from 3 to 12 carbon atoms in molecule in 25 min run. To improve sensitivity, the preconcentration step has been optimized using Oasis-WAX and C18 sorbents for SPE. A 100-fold preconcentration is achieved by solid-phase extraction with the sorbent C18 Sep-PAK to result in limits of detection in the range from 43 to 75 ppt for the analytes examined, and in the application of the method of water analysis.
Figure
Chromatogram of mixture of perfluorinated carboxylic acids C3-PFCA – C12-PFCA with fluorescence detection after derivatization with 3-bromoacetyl coumarin (b), and blank (a)  相似文献   

13.
A technique for solid-phase extraction utilizing pyridine-functionalized nanoporous silica (MCM-41, MCM-48 and SBA-15) was developed for the determination of gold in different samples using flame atomic absorption spectrometry. The effects of concentration and volume of eluent, pH of the solution, flow rate of extraction, sample volume and of potentially interfering ions on the efficiency of preconcentration and recovery was investigated. The limit of detection is lower than 45 pg mL?1. Under optimal conditions, the accuracy and precision (RSD%) of the method were calculated to be >99.5% and <0.7% for the two MCMs (41 and 48) and >89.5%, and <1.5% for SBA-15, respectively. The SPE technique was used to determine the concentration of gold in natural and industrial wastewater with satisfactory results.
Figure
A schematic model of modified mesoporous (MCM-41, MCM-48, SBA-15) with pyridine, and adsorption of Au(III)  相似文献   

14.
Conventional N-glycoproteome analysis usually applies C18 reversed-phase (RP) adsorbent for sample purification, which will lead to unavoidable sample loss due to the high hydrophilicity of N-glycopeptides. In this study, a porous graphitized carbon (PGC) absorbent was combined with a C18 adsorbent for N-glycopeptide purification in comprehensive N-glycoproteome analysis based on the hydrophobic and polar interactions between carbon and N-glycans. It was observed that the small hydrophilic N-glycopeptides that cannot retain onto C18 adsorbent can be captured by the graphitized carbon, while the large hydrophobic N-glycopeptides that cannot retain onto the graphitized carbon can be feasibly captured by the C18 adsorbent. Comparing with sample purification by using C18 adsorbent only, 28.5 % more N-glycopeptides were identified by combining both C18 and PGC adsorbents. The C18-PGC strategy was further applied for both sample purification and pre-fractionation of a complex protein sample from HeLa cell. After hydrophilic interaction chromatography enrichment, 1,484 unique N-glycopeptides with 1,759 unique N-glycosylation sites were finally identified.
Online Abstract Figure
The overlap of identified N-glycosylation sites by different SPE strategies  相似文献   

15.
We describe a molecularly imprinted electrochemical sensor for selective and sensitive determination of β2-agonists. It is making use of a combination of single-wall carbon nanotubes (SWNTs) with a molecularly imprinted sol–gel. The SWNTs were introduced in order to enhance electron transport and sensitivity. The imprinted sol–gel film with its specific binding sites acts as a selective recognition element and as a preconcentrator for β2-agonists. The morphology of the imprinted film was characterized by scanning electron microscopy. The optimized sensor displays high sensitivity and excellent selectivity for the β2-agonists as shown for their determination in human serum samples.
Figure
A molecularly imprinted electrochemical sensor was constructed for selective and sensitive determination of β2-agonists. The optimized sensor displays high sensitivity and excellent selectivity for the β2-agonists as shown for their determination in human serum samples.  相似文献   

16.
We have developed a gold ion-imprinted polymer (GIP) by incorporating a dipyridyl ligand into an ethylene glycol dimethacrylate matrix which then was coated onto porous silica particles. The material was used for the selective extraction of ultratrace quantities of gold ion from mine stones, this followed by its quantitation by FAAS. The effects of concentration and volume of eluent, pH of the solution, flow rates of sample and eluent, and effect of potentially interfering ions, especially palladium and platinum, was investigated. The limit of detection is <0.2 ng?mL?1, the precision (RSD%) is 1.03 %, and recoveries are >99 %. In order to show the high selectivity and efficiency of the new sorbent, the results were compared to those obtained with more simple sorbents possessing the same functional groups. The accuracy of the method was demonstrated by the accurate determination of gold ions in a certified reference material. To the best of our knowledge, there is no report so far on an imprint for gold ions that has such a selectivity over Pd(II) and Pt(II) ions.
Figure
Coating of gold ion imprinted polymer on nanoporous silica  相似文献   

17.
We describe a nanometer sized composite material made from titanium dioxide and silica that was chemically modified with 4-aminophenylarsonic acid and used for selective solid-phase extraction, separation and preconcentration of of aluminum(III) prior to its determination by ICP-OES. Under optimized conditions, the static adsorption capacity is 56.58?mg?g?1, the enrichment factor is 150, the relative standard deviation is 1.6% (for n?=?11), and the detection limit (3?s) is 60?pg?mL?1. The method was validated by analyzing the reference materials GBW 09101 (hair) and GBW 10024 (scallop) and successfully applied to the determination of trace Al(III) in spiked water samples and human urine, with recoveries ranging from 96% to 101%.
Figure
4-aminophenylarsonic acid modified nanometer TiO2/SiO2 composite material has been developed to separate and concentrate trace Al(III) from aqueous samples. Parameters that affect the sorption and elution efficiency were studied in column mode, and the new adsorbent presents high selectivity and adsorption capacity for the solid phase extraction of trace Al(III).  相似文献   

18.
Saponins are widely distributed in the plant kingdom and have been shown to be active components of many medicinal herbs. In this study, a two-dimensional purification method based on reversed-phase liquid chromatography coupled with hydrophilic interaction liquid chromatography was successfully applied to purify saponins from leaves of Panax notoginseng. Nine saponin reference standards were used to test the separation modes and columns. The standards could not be resolved using C18 columns owing to their limited polar selectivity. However, they were completely separated on a XAmide column in hydrophilic interaction liquid chromatography mode, including two pairs of standards that were coeluted on a C18 column. The elution order of the standards on the two columns was sufficiently different, with a correlation coefficient between retention times on the C18 and XAmide columns of 0.0126, indicating good column orthogonality. Therefore, the first-dimension preparation was performed on a C18 column, followed by a XAmide column that was used to separate the fractions in the second dimension. Fifty-four fractions were prepared in the first dimension, with 25 fractions rich in saponins. Eight saponins, including two pairs of isomeric saponins and one new saponin, were isolated and identified from three representative fractions. This procedure was shown to be an effective approach for the preparative isolation and purification of saponins from leaves of P. notoginseng. Moreover, this method could possibly be employed in the purification of low-content and novel active saponins from natural products.
Figure
Separation of saponins using 2-D RPLC/HILIC  相似文献   

19.
Nanoporous gold (NPG) with uniform pore sizes and ligaments was prepared by using a simple dealloying method. NPG electrodes exhibit excellent electrocatalytic activity towards the oxidation of CySH and the mechanism for the electrochemical reaction of CySH on NPG has been discussed. Interestingly, if the operating potential is fixed at 0.65 V, a strong current is observed and interferences by tryptophan and tyrosine are avoided. The calibration plot is linear in the concentration range from 1 μM to 400 μM (R2?=?0.994), and the quantification limit is as low as 50 nM. The NPG-modified electrode has good reproducibility, high sensitivity and selectivity, can be used to sense CySH in aqueous solution.
Figure
Nanoporous gold with uniform pore sizes and ligaments was employed as sensitive and selective electrochemical sensor for detection of Lcysteine, and the quantification limit is as low as 50 nM.  相似文献   

20.
The fluorescence quenching of quantum dots by hemoglobin has been demonstrated to depend on surface functionalization, and this property has been utilized to construct a novel fluorescent method for rapid, sensitive, and selective detection of trace hemoglobin in urine at microgram level. This method shows low interference and high selectivity for hemoglobin with a limit of detection of 4.3 μg L?1 in water and 66.1 μg L?1 in urine, which are lower than those of currently used methods in labs and clinics. Spike and recovery tests in raw, acidified, and alkalized urine samples exhibit good recovery rates for the spiked concentrations close to the limit of detection.
Figure
Fluorescence spectra and photographs of MPA-QD solution before and after the addition of Hb taken under 365-nm irradiation.  相似文献   