首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
This article reports the synthesis of N‐vinylimidazole/divinylbenzene resins by suspension polymerization. Several polymerization conditions were tested to achieve a quantitative incorporation of the N‐vinylimidazole monomer into the final polymer while a high specific surface area was maintained. The retention properties of several copolymers with different nitrogen contents were evaluated with the solid‐phase extraction of polar compounds from water samples, and the best results were obtained for a polymer containing 6.3% N with a surface area of 627 m2 g?1. The sorption properties of the resins were compared to those of styrene–divinylbenzene and other copolymers containing nitrogen, and the results were best for the new sorbents with N‐vinylimidazole as the polar monomer. © 2004 Wiley Periodicals, Inc. J Polym Sci Part A: Polym Chem 42: 2019–2025, 2004  相似文献   

2.
Sulfonated poly(styrene‐divinylbenzene) modified with five kinds of amine functional groups was applied to the determination of carbendazim in apple samples with a pipette‐tip solid‐phase extraction method. The structures of the polymers were characterized by scanning electron microscopy, Fourier transform infrared spectroscopy, and thermogravimetric analysis. Five different modifications of the solid‐phase extraction sorbent based on sulfonated poly(styrene‐divinylbenzene) were tested under static and pipette‐tip solid‐phase extraction conditions. The polymer modified with p‐methoxyaniline showed the best recognition capacity and adsorption amount for carbendazim. Under the optimum conditions, 3.00 mg of the adsorbent, 1.00 mL of ethyl acetate as washing solvent, and 1.00 mL of ammonia/acetonitrile (5:95, v/v) as elution solvent were used in the pretreatment procedure of apple samples. The calibration graphs of carbendazim in methanol were linear over 5.00–200.00 μg/mL, and the limits of detection and quantification were 0.01 and 0.03 μg/mL, respectively. The method recoveries of carbendazim were in the range of 91.31–98.13% with associated intraday relative standard deviations of 0.76–2.13% and interday relative standard deviations of 1.10–1.85%. Sulfonated poly(styrene‐divinylbenzene) modified with p‐methoxyaniline showed satisfactory results (recovery: 97.96%) and potential for the rapid purification of carbendazim in apple samples combined with the pipette‐tip solid‐phase extraction.  相似文献   

3.
A new mesoporous silica based on the sol–gel material cyanopropyltriethoxysilane (CNPrTEOS) was successfully synthesized by the hydrolysis and condensation of CNPrTEOS in the presence of ammonium solution as catalyst and methanol as solvent. It was used as a solid‐phase extraction sorbent for the simultaneous extraction of three organophosphorus pesticides, namely, polar dicrotophos and non‐polar diazinon and chlorpyrifos. Analysis was performed using high‐performance liquid chromatography with UV detection. CNPrTEOS was characterized by FTIR spectroscopy, field‐emission scanning electron microscopy and nitrogen gas adsorption. The surface area and average pore diameter of the optimum sol–gel CNPrTEOS are 379 m2/g and 4.7 nm (mesoporous), respectively. The proposed solid‐phase extraction based on CNPrTEOS exhibited good linearity in the range of 0.8–100 μg/L, satisfactory precision (1.15–3.82%), high enrichment factor (800) and low limit of detection (0.072–0.091 μg/L). The limits of detection obtained using the proposed solid‐phase extraction method are well below the maximum residue limit set by European Union and are also lower (13.6–48.5×) than that obtained by using a commercial CN‐SPE cartridge (0.98–4.41 μg/L). The new mesoporous sol–gel CNPrTEOS showed promising alternative as SPE sorbent material for the simultaneous extraction of polar and non‐polar organophosphorus pesticides.  相似文献   

4.
《Electrophoresis》2018,39(14):1808-1815
Poly(styrene‐co‐divinylbenzene)‐coated magnetic multiwalled carbon nanotube composite synthesized by in‐situ high temperature combination and precipitation polymerization of styrene‐co‐divinylbenzene has been employed as a magnetic sorbent for the solid phase extraction of antidepressants in human urine samples. Fluoxetine, venlafaxine, citalopram and sertraline were, afterwards, separated and determined by capillary electrophoresis with diode array detection. The presence of magnetic multiwalled carbon nanotubes in native poly(styrene‐co‐divinylbenzene) not only simplified sample treatment but also enhanced the adsorption efficiencies, obtaining extraction recoveries higher than 89.5% for all analytes. Moreover, this composite can be re‐used at least ten times without loss of efficiency and limits of detection ranging from 0.014 to 0.041 μg/mL were calculated. Additionally, precision values ranging from 0.08 to 7.50% and from 0.21 to 3.05% were obtained for the responses and for the migration times of the analytes, respectively.  相似文献   

5.
Fully crosslinked, stable poly(styrene‐co‐divinylbenzene) microspheres, which are composed of various concentrations of divilylbenzene from 5 to 75 mol % based on styrene monomer, were prepared without a significant particle coagulation by the precipitation polymerization. The number‐average particle diameter ranged from 3.5 to 2.8 μm and decreased with an increasing concentration of divinylbenzene in monomer. In addition, the coefficient of variation of the microspheres was slightly reduced with the increasing concentration of divinylbenzene. The circularity and the measured specific surface area indicated that lesser particles are coagulated because of the improved stability of individual particles at a high divinylbenzene concentration and that the resulting particles have a smooth surface without micropores. The glass‐transition temperature was not observed for all microspheres formed from the range of divinylbenzene concentrations. In addition, the onset of the thermal‐degradation temperature was increased from 339.8 to 376.9 °C upon higher contents of divinylbenzene. On the basis of the DSC and thermogravimetric data, the polymer microspheres prepared by the precipitation polymerization possessed a fully crosslinked structure and highly enhanced thermal stability. © 2004 Wiley Periodicals, Inc. J Polym Sci Part A: Polym Chem 42: 835–845, 2004  相似文献   

6.
Two different gel‐type resins have been prepared by suspension polymerization using 2 wt % divinylbenzene (DVB) with either p‐vinylbenzyl chloride (pVBC) or a mixture of VBC isomers (~ 70% m‐; ~ 30% p‐). Significant difference in the chlorine content was observed, which was attributed to a more favored hydrolysis process when p‐VBC was used. The presence of hydroxyl groups has been confirmed by elemental microanalytical data and solid‐state 13C cross‐polarization/magic angle spinning (CP‐MAS) nuclear magnetic resonance (NMR) spectra. Hypercrosslinked resins were prepared from both gel‐type precursors by treatment with FeCl3 in 1,2‐dichloroethane (DCE) at 80 °C. The resultant resins showed differences in specific surface area and degree of hydrophilicity. The performance of the hypercrosslinked resins was evaluated in solid‐phase extraction (SPE) of polar compounds, and better results were obtained for the hypercrosslinked resin prepared from p‐VBC that combines a relatively high specific surface area (908 m2 g?1) and somewhat higher oxygen content (3.96 wt % O). © 2005 Wiley Periodicals, Inc. J Polym Sci Part A: Polym Chem 43: 1718–1728, 2005  相似文献   

7.
Fully crosslinked, stable poly(styrene‐co‐divinylbenzene) microspheres were prepared by precipitation polymerization, and a new mechanism is proposed, based on the morphology, circularity, and specific surface area. Once the stable particles were generated by aggregation of the primary nucleus particles, they grew in size by absorbing oligomeric species without generating substantial pores. The investigation was carried out characterizing the particles in the polymerization time and in various concentrations of the polymerization ingredients. Particle size continuously grew, but the uniformity and circularity of the microspheres were reduced with polymerization time because of the higher reactivity of divinylbenzene. The measured specific surface areas of the microspheres all were less than 10 m2/g, which showed good agreement with calculated values under an assumption of no pores on the surface of the microspheres. Thus, the specific surface area of the microspheres supported the proposed mechanism. © 2004 Wiley Periodicals, Inc. J Polym Sci Part A: Polym Chem 42: 3967–3974, 2004  相似文献   

8.
With the explosive growth of the bioscience and biopharmaceuticals, the demand for high efficient analysis and separation of proteins is urgent. High‐performance liquid chromatography is an appropriate technology for this purpose, and the stationary phase is the kernel to the separation efficiency. In this study, flow‐through poly(styrene‐co‐divinylbenzene) microspheres characteristic of the binary pores, i.e. flow‐through pores and mesopores, were synthesized; this special porous structure would benefit the convective mass transfer while guarantee the high specific surface area. Owing to the hydrophobic nature, poly(styrene‐co‐divinylbenzene) microspheres were suitable as the reversed‐phase stationary phase for separation of proteins. For the high permeability of the poly(styrene‐co‐divinylbenzene) microspheres packed column, fast separation of the studied six proteins in ~2 min was achieved. The recoveries of studied proteins were acceptable in the range of 79.0–99.4%. The proposed column had good pH stability of 1–13 and repeatability. Moreover, the column was applied for egg white fast separation, further demonstrating its applicability for complex bio‐sample separation. The flow‐through poly(styrene‐co‐divinylbenzene) microspheres were promising for fast separation of large molecules.  相似文献   

9.
Relative polarity values and retention indices for a mixture of normal paraffins C5–C10 and alkylbezenes C6–C9 are determined for four types of monolithic capillary columns based on divinylbenzene, ethylene glycol dimethacrylate, pentaerythritol tetraacrylate, and pentaerythritol triacrylate. It is established that the retention of polar sorbates increases with a rise in stationary phase polarity, while the retention of nonpolar compounds grows with a reduction in stationary phase polarity.  相似文献   

10.
LC retention data have been measured using various stationary phases with an emphasis on highly polar to moderately polar neutral organic compounds having octanol‐water partition coefficients (Kow) in log units between 0 and 3. The relationships between the retention factor measured in water and the octanol‐water partition coefficient are linear but with different slopes for octadecyl (C18) silicas, and two polystyrene divinylbenzene (PS‐DVB) phases with low and high surface areas. These relationships confirm that highly cross‐linked polymers can provide more than 1000‐times higher retention values than C18 silicas for moderately polar analytes but close values for highly polar ones. They also explain why C18 silicas and polymers are equivalent for the separation of very polar analytes. In contrast, due to a different retention mechanism, no relation exists between the retention shown by porous graphitic carbons (PGC) and analyte hydrophobicity, but highly polar analytes are in general much more strongly retained than by any other sorbent. The potential of PGC for both the extraction and the separation of analytes is shown. Due to the difference in separation mechanism, PGC is the analytical phase that should be used for confirmation of the identity of analytes instead of a cyanopropylsilica column as recommended in some environmental procedures. Applications are presented for the trace‐determination of triazines and polar degradation products in ground and surface water with detection limits below the 0.1 μg/L level.  相似文献   

11.
The polymerization of 4‐vinylpyridine was conducted in the presence of a cyclic trithiocarbonate (4,7‐diphenyl‐[1,3]dithiepane‐2‐thione) as a reversible addition–fragmentation transfer (RAFT) polymerization agent, and a multiblock polymer with narrow‐polydispersity blocks was prepared. Two kinds of multiblock copolymers of styrene and 4‐vinylpyridine, that is, (ABA)n multi‐triblock copolymers with polystyrene or poly(4‐vinylpyridine) as the outer blocks, were prepared with multiblock polystyrene or poly(4‐vinylpyridine) as a macro‐RAFT agent, respectively. GPC data for the original polymers and polymers cleaved by amine demonstrated the successful synthesis of amphiphilic multiblock copolymers of styrene and 4‐vinylpyridine via two‐step polymerization. © 2007 Wiley Periodicals, Inc. J Polym Sci Part A: Polym Chem 45: 2617–2623, 2007  相似文献   

12.
13.
This paper discusses the development of a comprehensive method for the simultaneous analysis of personal care products (PCPs) based on SPE and GC‐MS. The method was developed on 29 target compounds to represent PCPs belonging to different chemical classes: surfactants in detergents (alkyl benzenes), fragrances in cosmetics (nitro and polycyclic musks), antioxidants and preservatives (phenols), plasticizers (phthalates) displaying a wide range of volatility, polarity, water solubility. In addition to the conventional C18 stationary phase, a surface modified styrene divinylbenzene polymeric phase (StrataTM X SPE cartridge) has been investigated as suitable for the simultaneous extraction of several PCPs with polar and non‐polar characteristics. For both sorbents different solvent compositions and eluting conditions were tested and compared in order to achieve high extraction efficiency for as many sample components as possible. Comparison of the behavior of the two cartridges reveals that, overall, Strata‐X provides better efficiency with extraction recovery higher than 70% for most of the PCPs investigated. The best results were obtained under the following operative conditions: an evaporation temperature of 40°C, elution on Strata‐X cartridge using a volume of 15 mL of ethyl acetate (EA) as solvent and operating with slow flow rate (–10 KPa). In addition to the conventional method based on peak integration, a chemometric approach based on the computation of the experimental autocovariance function (EACVFtot) was applied to the complex GC‐MS signal: the percentage recovery and information on peak abundance distribution can be evaluated for each procedure step. The PC‐based signal processing proved very helpful in assisting the development of the analytical procedure, since it saves labor and time and increases result reliability in handling GC complex signals.  相似文献   

14.
This article describes the synthesis and characterization of [polystyrene‐b‐poly(2‐vinylpyridine)]n star‐block copolymers with the poly(2‐vinylpyridine) blocks at the periphery. A two‐step living anionic polymerization method was used. Firstly, oligo(styryl)lithium grafted poly(divinylbenzene) cores were used as multifunctional initiators to initiate living anionic polymerization of styrene in benzene at room temperature. Secondly, vinylpyridine was polymerized at the periphery of these living (polystyrene)n stars in tetrahydrofuran at ?78 °C. The resulting copolymers were characterized using size exclusion chromatography, multiangle laser light scattering, 1H NMR, elemental analysis, and intrinsic viscosity measurements. © 2007 Wiley Periodicals, Inc. J Polym Sci Part A: Polym Chem 45: 3949–3955, 2007  相似文献   

15.
New restricted access materials based on microporous hypercrosslinked polystyrene have been developed. The materials are aimed to use as packings for solid‐phase extraction cartridges to isolate low‐molecular‐weight analytes from biological fluids (for instance, blood plasma or serum). Two features distinguish these polymers from all known restricted access materials. The first one consists of the microporous hypercrosslinked polystyrene that not only exclude proteins from the sorbent phase but also do not adsorb them on the bead outer surface, and so they do not cause coagulation of blood protein components. Therefore, these materials do not require any chemical modification. The second distinguishing feature is the ability of hypercrosslinked sorbents to take up a wide variety of polar and nonpolar organic compounds. The sorbents were obtained in the form of beads of 60–70 μm in diameter by cross‐linking styrene copolymers with 1, 2, and 3% divinylbenzene with monochlorodimethyl ether to 100, 150, and 200% cross‐linking degree. The sorbents exhibit all typical properties of hypercrosslinked networks. They do not take up albumin, the major blood protein, and cytochrome C, representative of smaller protein molecules, but are capable of adsorbing drugs, vitamins, and phenyl carboxylic acids (markers of sepsis) from model aqueous solutions.  相似文献   

16.
Experimental evidence is presented that describes the mechanism of formation of macroreticular styrene–divinylbenzene copolymers in which phase separation occurs during a suspension polymerization. The mode of formation of the macroreticular structure is described as a three-stage process in which each droplet of the organic phase behaves as an individual in a bulk polymerization that results in a bead of copolymer. Macroreticular structure formation is described by changes in copolymer swelling ratios, infrared absorption spectra of vinyl groups pendent to the polymeric matrices, surface area, total porosity, and pore-size distribution. The proposed mechanism of formation is also substantiated by electron micrographs of the copolymers during various stages of the copolymerization.  相似文献   

17.
A range of silanylene‐spaced divinylbenzene copolymers ( 1 ) and the corresponding monomers ( 2 ) have been synthesized by the rhodium‐catalyzed hydrosilylation of the corresponding bisalkynes with bissilyl hydrides, and the photophysical properties of 1 and 2 have been investigated. The silicon moiety in 1 serves as an insulating tetrahedral spacer that makes 1 highly folded. The two chromophores may be in close proximity such that a ground‐state intrachain interaction between two conjugated moieties through space might occur. © 2003 Wiley Periodicals, Inc. J Polym Sci Part A: Polym Chem 41: 2218–2231, 2003  相似文献   

18.
Thionins belong to a family of cysteine‐rich, low‐molecular‐weight (~5 KDa) biologically active proteins in the plant kingdom. They display a broad cellular toxicity against a wide range of organisms and eukaryotic cell lines. Thionins protect plants against different pathogens, including bacteria and fungi. A highly selective solid‐phase extraction method for plant thionins is reported deploying aluminum silicate (3:2 mullite) powder as a sorbent in extraction columns. Mullite was shown to considerably improve selectivity compared to a previously described zirconium silicate embedded poly(styrene‐co‐divinylbenzene) monolithic polymer. Due to the presence of aluminum(III), mullite offers electrostatic interactions for the selective isolation of cysteine‐rich proteins. In comparison to zirconium(IV) silicate, aluminum(III) silicate showed reduced interactions towards proteins which resulted into superior washings of unspecific compounds while still retaining cysteine‐rich thionins. In the presented study, European mistletoe, wheat and barley samples were subjected to solid‐phase extraction analysis for isolation of viscotoxins, purothionins and hordothionins, respectively. Matrix‐assisted laser desorption/ionization time of flight mass spectroscopy was used for determining the selectivity of the sorbent toward thionins. The selectively retained thionins were quantified by colorimetric detection using the bicinchoninic acid assay. For peptide mass‐fingerprint analysis tryptic digests of eluates were examined.  相似文献   

19.
Molecularly imprinted microspheres containing binding sites for the extraction of 4‐cumylphenol have been prepared for the first time. The imprinted microspheres were synthesized by a precipitation method using 4‐cumylphenol as a template molecule, methacrylic acid as a functional monomer and divinylbenzene‐80 as a cross‐linker for polymer network formation. The formation and the morphology of molecularly imprinted microspheres were well characterized using infrared spectroscopy, thermogravimetric studies, and scanning electron microscopy. The Brunauer–Emmett–Teller analysis revealed the high surface area of the sorbent indicating formation of molecularly imprinted microspheres. The developed microspheres were employed as a sorbent for the solid‐phase extraction of 4‐cumylphenol and showed fast uptake kinetics. The sorption parameters were optimized to achieve efficient sorption of the template molecule, like pH, quantity of molecularly imprinted microspheres, time required for equilibrium set‐up, sorption kinetics, and adsorption isotherm. A standard method was developed to analyze the sorbed sample quantitatively at 279 nm using high‐performance liquid chromatography with diode array detection. It was validated by determining target analyte from synthetic samples, bottled water, spiked tap water, and soil samples. The prepared material is a selective and robust sorbent with good reusability.  相似文献   

20.
Nanosized spherical magnetic poly(vinylimidazole‐co‐divinylbenzene) particles were synthesized and used as a sorbent for the enrichment of trace fluoroquinolones (FQs) from environmental water samples. A suspension polymerization procedure was used to prepare the sorbent. The magnetic sorbent was characterized by SEM, transmission electron microscopy, elemental analysis, and FTIR spectroscopy. Analysis of enrofloxacin, marbofloxacin, fleroxacin, lomefloxacin, and sparfloxacin in environmental water samples by the combination of the magnetic sorbent and HPLC with diode array detection was selected as a paradigm for the practical application of the new adsorbent. Several extraction conditions, including desorption solvent, extraction and desorption time, pH value, and ionic strength in sample matrix, were optimized. Results showed that the new sorbent had high affinity for FQs and could be used to extract them effectively. Under the optimum conditions, low detection (S/N = 3) and quantification (S/N = 10) limits were achieved for the target analytes, within the ranges of 0.20–1.46 and 0.68–4.84 μg/L, respectively. Method repeatability was achieved in terms of intra‐ and interday precisions, indicated by the RSDs, which were both <10.0%. The method also showed good linearity, simplicity, practicality, and environmental friendliness for the extraction of FQs. Finally, the developed method was successfully applied to the determination of FQs in lake water, surface water, and reservoir water samples. Acceptable recoveries of spiked target compounds in these water samples were in the range of 52.1–104.5%.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号