首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 484 毫秒
1.
A rapid and quantitative method for the extraction, derivatization, and liquid chromatography with fluorescence detection of ivermectin (IVM) and doramectin (DOM) residues in porcine liver was developed and validated. IVM and DOM were extracted from the liver samples with acetonitrile, the supernatant was evaporated to dryness at 37 degrees C under nitrogen, and the residue was reconstituted in 1-methylimidazole solution. After 2 min at room temperature, IVM and DOM were converted to a fluorescent derivative and then separated on a Hypersil ODS column. The derivatives of IVM and DOM were detected and quantitated with high specificity by fluorescence (excitation: 365 nm, emission: 475 nm). Abamectin was used as an internal standard. The mean extraction efficiencies from fortified samples (15 ng/g) were 75% for IVM and 70% for DOM. The limit of detection was 0.8 ng/g for both IVM and DOM.  相似文献   

2.
A liquid chromatographic (LC) method with 2 detection systems for determining atropine (hyoscyamine) sulfate in commercial products was tested in a multilaboratory study. Depending on the type of product, sample solutions are prepared in methanol or methanol-water (1 + 1). The standard solution contains about 1.0 mg atropine sulfate/100 mL and is prepared in the same solvent used in sample preparation. LC separations are performed on a 7.5 cm Novapak silica column. The mobile phase is prepared by mixing 970 mL methanol with 30 mL of a 1% aqueous solution of 1-pentanesulfonic acid, sodium salt. Detection is by 2 systems, UV absorbance detection at 220 nm and fluorescence detection with excitation at 255 nm and emission at 285 nm. The injection volume is 100 or 200 microL. The following materials were used for the study: 2 separate samples of tablets labeled to contain 0.4 mg atropine sulfate, 2 separate samples of extended-release tablets labeled to contain 0.375 mg hyoscyamine sulfate, one sample of atropine sulfate injection labeled to contain 2 mg/mL, and one sample of 1% (v/v) atropine sulfate ophthalmic. Eight participants analyzed 2 separate portions of the 6 samples by both detection systems. A ninth participant analyzed the samples in duplicate but only by UV absorbance detection because of the unavailability of a fluorescence detector. The relative standard deviation (RSD) between laboratories ranged from 1.4 to 3.3% for samples of tablets and injections but higher for ophthalmic solutions (5.1-5.2%). A linearity study was conducted in the originating laboratory before the multilaboratory study with 5 solutions ranging in concentration from 0.80 to 1.20 mg atropine sulfate in 100 mL. Average recoveries were 100.0% by UV absorbance detection and 99.9% by fluorescence detection; the RSDs were 1.1 and 1.2%, respectively.  相似文献   

3.
A new liquid chromatography/atmospheric pressure chemical ionization-tandem mass spectrometry (LC/APCI-MS/MS) method with on-line sample clean-up for the determination of telmisartan in human blood plasma is presented. This technique is compared to a previously introduced enzyme-linked immunosorbent assay (ELISA), where fluorescence is used as detection method. For the LC/MS method applying an internal calibration via a deuterated internal standard, the limit of detection was 0.3 ng/mL, the limit of quantification was 0.9 ng/mL and the linear range extended from 0.9 to 1000 ng/mL. Forty-eight plasma samples from four healthy volunteers were analyzed in a pharmacokinetic study to obtain data for the method comparison. As a result, these two new and independent analytical methods for the determination of telmisartan in human blood plasma proved to yield comparable results for the amount of analyte.  相似文献   

4.
A rapid, sensitive and selective liquid chromatography/electrospray mass spectrometry (LC/ES-MS) method was developed for the quantitative determination of the anaesthetic benzodiazepine midazolam (MID) in human saliva and plasma from patients undergoing anesthesia procedures. Biological samples spiked with diazepam-d5, the internal standard, were extracted into diethyl ether. Compounds were separated on a Xterra RP18 column using a mobile phase of acetonitrile/formic acid 0.1% at a flow rate of 0.25 mL/min under a linear gradient. Column effluents were analyzed using MS with an ES source in the positive ionization mode. Calibration curves were linear in the concentration ranges of 1-250 and 0.2-25 ng/mL in plasma and saliva, respectively. The limits of detection were 0.5 ng/mL in plasma and 0.1 ng/mL in saliva, using a 0.5-mL sample volume. The recoveries of the spiked samples were above 65%. The method was applied to ten real samples from patients undergoing midazolam treatment.  相似文献   

5.
Carotenoids and vitamins A and E in multivitamin tablets can be determined simultaneously by reversed-phased liquid chromatography (LC) with a programmable UV detector. Samples were dissolved in dimethyl sulfoxide and then extracted with hexane. A portion was injected onto a Symmetry C18, 150 x 4.6 mm id, 5 microns column and chromatographed with a mobile phase of acetonitrile--0.25% ammonium acetate in methanol and 0.05% triethylamine in dichloromethane. A step gradient was used. The system was operated at 25 degrees C with a flow rate of 1.5 mL/min. UV detection was at 325 nm for retinols, 285 nm for tocopherols, and 450 nm for carotenoids. Detection limits were less than 0.3 ng for retinol and retinyl acetate; 2 ng for alpha-tocopherol acid succinate; 10 ng for alpha-tocopherol, gamma-tocopherol, and alpha-tocopherol acetate; and 0.4 ng for alpha-carotene and beta-carotene. Intraday and interday coefficients of variation ranged from 1.40 to 5.20%. The sample preparation method and LC assay are practical for quality control and routine analysis of multivitamin tablets.  相似文献   

6.
A method using an online solid-phase extraction (SPE) and ion-pairing liquid chromatography with electrospray tandem mass spectrometry (LC/ES-MS/MS) was developed for determination of amphetamine (Amp), methamphetamine (mAmp), 3,4-methylenedioxyamphetamine (MDA), 3,4-methylenedioxyethylamphetamine (MDEA), and 3,4-methylenedioxymethamphetamine (MDMA) in urine samples. A SPE cartridge column with both hydrophilic and lipophilic functions was utilized for online extraction. A reversed-phase C18 LC column was employed for LC separation and MS/MS was used for detection. Trifluoroacetic acid was added to the mobile phase as an ion-pairing reagent. This method was fully automated and the extraction and analysis procedures were controlled by a six-port switch valve. Recoveries ranging from 85-101% were measured. Good linear ranges (10-500 ng/mL) for Amp and mAmp were determined. For MDA, MDMA and MDEA, dual linear ranges were obtained from 5-100 and 100-500 ng/mL, respectively. The detection limit of each analytical compound, based on a signal-to-noise ratio of 3, ranged from 1-3 ng/mL. The applicability of this newly developed method was examined by analyzing several urine samples from drug users. Good agreement was obtained between the results from this method and a literature GC/MS method.  相似文献   

7.
The aims were to develop a liquid chromatographic (LC) method with ultraviolet detection (UVD) for O-(2,3,4,5,6-pentafluorobenzyl)hydroxylamine hydrochloride (PFBHA) O-oximes of common aldehydes and ketones, and to define the steric limits of the synthetic reaction used to make the PFBHA O-oxime standards for gas chromatographic (GC) and LC methods. Ten new O-oximes were synthesized with the new optimized method, and their purities were demonstrated by GC/electron-capture detection (ECD), GC/mass spectrometry (MS), ultraviolet spectroscopy, infrared spectroscopy, and proton and 13C-nuclear magnetic resonance spectroscopy. Ketones substituted at both beta-carbons relative to the carbonyl carbon, like diisobutyl ketone and 2,4-hexanedione, showed lower synthetic yields by wet chemistry methods. A new C18 reverse-phase LC method with UVD at 200 nm and acetonitrile-water in both the isocratic and gradient-elution modes was then developed to sensitively resolve a mixture of 13 pure PFBHA O-oximes. The detection limit was near 100 ng O-oxime/mL or about 14-50 ng aldehyde/mL and the least quantifiable limits were near 500 ng/mL or about 70-250 ng aldehyde/mL, with lower limits for glyoxal, methylglyoxal, benzaldehyde, and acetophenone. Carbonyl compounds in 500 mL water samples were then determined in distilled water and tap water by gradient elution. Vapors of n-valeraldehyde and acrolein generated in gas bags at concentrations near occupational guidelines were also sampled, desorbed, and then determined by either isocratic or gradient elution at 200 or 254 nm within 30-45 min.  相似文献   

8.
A determination method has been optimized and validated for the simultaneous analysis of tetracycline (TC), oxytetracycline (OTC), chlortetracycline (CTC) and doxycycline (DC) in honey. Tetracyclines (TCs) were removed from honey samples by chelation with metal ions bound to small Chelating Sepharose Fast Flow columns and eluted with Na2EDTA-Mcllvaine pH 4.0 buffers. Extracts were further cleaned up by Oasis HLB solid-phase extraction (SPE), while other solid-phase extraction cartridges were compared. Chromatographic separation was achieved using a polar end-capped C 18 column with an isocratic mobile phase consisting of oxalic acid, acetonitrile and methanol. LC with ultraviolet absorbance at 355 nm resulted in the quantitation of all four tetracycline residues from honey samples fortified at 15, 50, and 100 ng/g, with liner ranges for tetracyclines of 0.05 to 2 μg/mL. Mean recoveries for tetracyclines were greater than 50% with R.S.D. values less than 10% (n= 18). Detection limits of 5, 5, 10, 10 ng/g for oxytetracycline, tetracycline, chlortetracycline and doxycycline, respectively and quantitation limits of 15 ng/g for all the four tetracyclines were determined. Direct confirmation of the four residues in honey (2-50 ng/g) was realized by liquid chromatography-tandem mass spectrometry (LC/MS/MS). The linear ranges of tetracyclines determined by LC/MS/MS were between 5 to 300 ng/mL, with the linear correlation coefficient r〉 0.995. The limits of detection of 1 to 2 ng/g were obtained for the analysis of the TCs in honey.  相似文献   

9.
Electrospray ionization (ESI) mass spectra of 15 anti-estrogenic substances, beta2-agonists and mesocarb were investigated in terms of fragmentation patterns. On the basis of this product ion information, a simultaneous screening method for anti-estrogenic substances, beta2-agonists and mesocarb was developed for doping control purposes. After hydrolysis, liquid-liquid extraction was adopted for the sample preparation. The recoveries for all compounds were 30 and 96%. A single liquid chromatography/tandem mass spectrometry (LC/MS/MS) analysis could be performed in 13 min for the analysis of 15 anti-estrogenic substances, beta2-agonists and mesocarb. A quantitative analysis was also validated. Inaccuracies were below +/-12% and precisions varied from 0 to 15.8%. The limit of detection was below 10 ng/mL except formestane (300 ng/mL) and aminoglutethimide (100 ng/mL). The validated method was applied for the analysis of excretion samples.  相似文献   

10.
A rapid and sensitive automated coupled-column liquid chromatography/electrospray tandem mass spectrometry (LC/LC/ES-MS/MS) method has been developed for the quantitation of chlorpyrifos and 3,5,6-trichloro-2-pyridinol (TCP) in both human serum and urine. Human serum was first protein precipitated with acetonitrile, while urine was directly injected into the coupled-column system. A 10 microL aliquot was then analyzed using as first separation column a Discovery C18 5 microm 50 x 2.1 mm; the fraction containing the analyte was transferred on-line to the second column consisting of a ABZ+ 5 microm 100 x 2.1 mm, which was connected to the electrospray source (Z-spray) of a Quattro LC triple-quadrupole instrument. Chlorpyrifos was detected in positive ion mode using four multi reaction monitoring (MRM) transitions while TCP was measured in negative ion mode using three pseudo-MRM transitions. The clean-up performed by the coupled-column approach avoids the use of an internal standard for the correct quantitation of both analytes, and the highly automated procedure renders a sample throughput of more than 100 samples per day. Both compounds can be determined using the same set-up, the only difference in the procedure being the composition of the first mobile phase. The method has proved to be fast, reliable and sensitive, yielding calibration curves for both analytes with correlation coefficients greater than 0.9995. The repeatability and reproducibility at 5 and 50 ng/mL was lower than 8%. The accuracy and precision were evaluated by means of recovery experiments from fortified serum (5-50 ng/mL) and urine (1-10 ng/mL) samples, obtaining satisfactory recoveries for both compounds (87-113% in serum, and 98-109% in urine), with coefficients of variation (CVs) less than 10%. The detection limits were similar for chlorpyrifos and metabolite: 1.5 ng/mL in serum, and 0.5 ng/mL in urine, where no sample handling took place. The validated procedures provide excellent tools for the specific assessment of occupational exposure to the organophosphorus pesticide chlorpyrifos, throughout the analysis of both human serum and urine, and it is more selective and sensitive than the current assay based on the measurement of the decrease in the cholinesterase activity.  相似文献   

11.
Fluorotelomer alcohols (FTOHs) are important polyfluorinated raw materials that belong to the general category of perfluoroalkyl substances (PFAS). PFAS, including perfluoroalkyl carboxylates (PFCAs) and perfluoroalkyl sulfonates, have recently attracted considerable attention because they are persistent and found globally in the environment. FTOHs are precursors that may degrade in the environment to PFCAs. The development of analytical methods for determination FTOHs in environmental samples is necessary to determine the environmental presence of FTOHs. This work presents the development and validation of a liquid chromatography/tandem mass spectrometry (LC/MS/MS) method for the determination of FTOHs (6-2, 8-2, 10-2) in aqueous samples. Chromatographic conditions were optimized in order to obtain focused FTOH chromatographic peaks. The mobile phase and mass spectrometric conditions were optimized to enable formation of deprotonated FTOH molecules in the negative ion electrospray mode. Two extraction methods were investigated using acetonitrile and methyl tert-butyl ether (MTBE). These methods were validated for a range of environmental water samples fortified with FTOHs at three different levels. Both extraction methods resulted in recoveries from 70 to 120%. Detection limits of FTOHs were estimated to be approximately 0.09 ng/mL for LC/MS/MS detection. An LC/MS method was also developed for FTOH determination with an estimated 1.2 ng/mL limit of detection. Various sample storage scenarios were investigated. It was determined that the aqueous samples of FTOHs are best preserved by storing them frozen in sealed vials with aluminum foil lined septa.  相似文献   

12.
A simple, rapid and sensitive method for quantification of atomoxetine by liquid chromatography–tandem mass spectrometry (LC‐MS/MS) was developed. This assay represents the first LC‐MS/MS quantification method for atomoxetine utilizing electrospray ionization. Deuterated atomoxetine (d3‐atomoxetine) was adopted as the internal standard. Direct protein precipitation was utilized for sample preparation. This method was validated for both human plasma and in vitro cellular samples. The lower limit of quantification was 3 ng/mL and 10 nm for human plasma and cellular samples, respectively. The calibration curves were linear within the ranges of 3–900 ng/mL and 10 nm to 10 µm for human plasma and cellular samples, respectively (r2 > 0.999). The intra‐ and inter‐day assay accuracy and precision were evaluated using quality control samples at three different concentrations in both human plasma and cellular lysate. Sample run stability, assay selectivity, matrix effect and recovery were also successfully demonstrated. The present assay is superior to previously published LC‐MS and LC‐MS/MS methods in terms of sensitivity or the simplicity of sample preparation. This assay is applicable to the analysis of atomoxetine in both human plasma and in vitro cellular samples. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

13.
A simple, rapid and sensitive LC‐UV method was developed and validated for the determination of paclitaxel (PTX) in rabbit plasma and tissues. A 2 mL aliquot of acetonitrile and 10 μL ammonium acetate (pH 5.0, 6 m ) as extraction agents were used to markedly increase the extraction recoveries and greatly reduce the endogenous substances. The separation was achieved on a C18 column at 30 °C using an acetonitrile–ammonium acetate buffer (pH 5.0, 0.02 m ; 55:45, v/v) at a flow rate of 1.0 mL/min; UV detection was used at 227 nm. Good linearity was obtained between 0.025 and 10,000 µg/mL for plasma and between 0.025–200,000 µg/g for tissue samples (r > 0.999). The limit of detection was 6 ng/mL in plasma, 8 ng/g in heart and 12.5 ng/g in other tissues. The limit of quantitation was 25 ng/mL in plasma and heart, 125 ng/g in other tissues. The intra‐ and inter‐day assays of precision and accuracy for all bio‐samples ranged from 1.38 to 9.60% and from 83.6 to 114.5%, respectively. The extraction recoveries ranged from 70.1 to 109.5%. Samples were stable during three freeze–thaw cycles or stored in a freezer at ?20 °C for 30 days. The assay method was successfully applied to a study of the pharmacokinetics and tissue distribution of novel PTX lung targeting liposomes. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

14.
We present a method for the quantitation of motilin from rat plasma by protein precipitation and liquid chromatography/mass spectrometry (LC/MS). Using external calibration, the method was linear over the concentration range 10-1000 ng/mL with an initial sample volume of 150 microL. The LC system included a C(18) column with a 300 A pore size. A linear gradient was used with a mobile phase consisting of water and acetonitrile, each with 0.2% acetic acid and 0.02% trifluoroacetic acid. Motilin was detected with the mass spectrometer in positive ion mode monitoring the 4+ charge state at m/z 675.5. The approximated limit of detection was less than 1 ng/mL and the lower limit of quantitation (LLOQ) was 10 ng/mL. The method showed a high degree of precision and accuracy both within and between runs at five validation points, including the LLOQ.  相似文献   

15.
A method was developed for determination of St. John's wort marker compounds hypericin, pseudohypericin, hyperforin, and adhyperforin in functional foods. Solid-phase extraction provided analyte extraction and significant sample cleanup prior to analysis using liquid chromatography (LC) with UV and fluorescence detection. In addition to quantification using LC-UV, confirmation was made with electrospray ionization LC mass spectrometry (LC/MS). Several commercially available tea and drink products claiming to contain St. John's wort were tested. Recoveries ranged from 51 to 98% for the liquid samples. Comparison of the concentrations in 4 St. John's wort teas showed a variation in analyte concentration (1044-10 ng/mL marker compounds in brewed tea) and composition. No marker compounds were found in the beverages, indicating possible decomposition of the marker compounds caused by low pH and/or exposure to light. A solvent extraction procedure was developed for analysis of the marker compounds from solid samples. Analytes were detected at low parts per million, with an average recovery of 75%. No St. John's wort components were found in the 2 solid functional food samples analyzed.  相似文献   

16.
Quantitative determination of drug concentrations in tissue samples can provide critical information for drug metabolism, kinetics, and toxicity evaluations. For analysis of tissue samples using liquid chromatography/tandem mass spectrometric (LC/MS/MS) detection, homogenization is a critical step in achieving good assay performance. Assay performance can be closely evaluated by spiking the drug directly into tissue samples prior to homogenization. It is especially important to include this assay evaluation for the analysis of artery tissue samples because artery tissue is very elastic, making it quite a challenge to develop an effective procedure for homogenization. An LC/MS/MS assay in 96-well format using liquid-liquid extraction was developed for analyzing ABT-578 in rabbit artery samples. Tissue quality control samples were prepared by spiking ABT-578 stock solutions directly into the tissue before homogenization. The usage of the tissue control samples gives a thorough evaluation of the sample preparation process that includes both homogenization and sample extraction. A 20% blood in saline solution was used as a homogenization solution. Calibration standards were made by spiking ABT-578 into rabbit whole blood. Blood quality control samples were also prepared by spiking ABT-578 into rabbit whole blood. These blood QC samples were used to confirm the validity of the calibration curve. A lower limit of quantitation of 0.050 ng/mL was achieved. The linear dynamic range of blood standards was from 0.050-30.3 ng/mL with the correlation coefficient (r) ranging from 0.9969-0.9996. Overall %CV was between 1.3 and 7.0%, and analytical recovery was between 98.2 and 105.8% for blood QC samples. The %CVs for tissue QC samples were between 6.7 and 13.0%, and analytical recovery after correction was between 93.5 and 114.3%.  相似文献   

17.
18.
基于中性解吸-电喷雾萃取电离质谱(ND-EESI-MS)建立了无需样品预处理即可直接检测蜂蜜中四环素的方法. 测定结果表明, 加标蜂蜜四环素样品在20~1000 ng/mL浓度范围内线性关系良好(R2>0.997), 检出限为1.08 ng/mL; 加标浓度为50, 500和1000 ng/mL蜂蜜样品的回收率分别为94.26%, 98.38%和103.00%, 精密度(RSD)分别为3.28%, 1.39%和1.12%. 应用此方法对8种市售蜂蜜进行检测, 发现2种蜂蜜中含有痕量的四环素, 其余蜂蜜均未检出, 而应用高效液相色法在这8种市售蜂蜜中均未检出四环素. 本方法无需经过复杂的样品预处理, 灵敏度高、 精密度好、 分析速度快且特异性强, 能够承受蜂蜜中复杂基体的影响, 是一种快速检测蜂蜜中四环素的方法.  相似文献   

19.
An original analytical method has been developed for the determination of the antioxidants trans-resveratrol (t-RSV) and cis-resveratrol (c-RSV) and of melatonin (MLT) in red and white wine. The method is based on HPLC coupled to fluorescence detection. Separation was obtained by using a RP column (C8, 150 mm x 4.6 mm id, 5 mum) and a mobile phase composed of 79% aqueous phosphate buffer at pH 3.0 and 21% ACN. Fluorescence intensity was monitored at lambda = 386 nm while exciting at lambda = 298 nm, mirtazapine was used as the internal standard. A careful pretreatment of wine samples was developed, using SPE with C18 cartridges (100 mg, 1 mL). The calibration curves were linear over the following concentration ranges: 0.03-5.00 ng/mL for MLT, 3-500 ng/mL for t-RSV and 1-150 ng/mL for c-RSV. The LOD values were 0.01 ng/mL for MLT, 1 ng/mL for t-RSV and 0.3 ng/mL for c-RSV. Precision data, as well as extraction yield and sample purification results, were satisfactory. Thus, the method seems to be suitable for the analysis of MLT and resveratrol isomers in wine samples. Moreover, wine total polyphenol content and antioxidant activity were evaluated.  相似文献   

20.
A selective, sensitive and rapid liquid chromatography-tandem mass spectrometry method has been developed for the determination of caudatin-2,6-dideoxy-3-O-methy-beta-d-cymaropyranoside (CDMC) in rat plasma. This method involves a plasma clean-up step using liquid-liquid extraction, followed by LC separation and positive electrospray ionization mass spectrometry detection (LC/ESI-MS/MS). Chromatographic separation of the analytes was achieved using a C(18) column with a mobile phase of acetonitrile and water (70:30, v/v) at a flow rate of 1.0 mL/min. Low energy collision tandem mass spectrometric analysis (CID-MS/MS) using the multiple reaction monitoring (MRM) mode was used for analyte quantification. For the MRM analysis of CDMC, the following transition at m/z 658.4 --> 529.6 derived from the protonated molecule [M + Na](+). A calibration curve was linear in the 5-500 ng/mL range for CDMC, and the limit of detection was 5 ng/mL. The inter- and intra-day precisions (RSD) were 相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号