Critical heat flux and turbulent mixing in hexagonal tight rod bundles   总被引:3,自引:0,他引:3  
Experimental and theoretical investigations have been performed on critical heat flux (CHF) and turbulent mixing in tight, hexagonal, 7-rod bundles. Freon-12 was used as working fluid due to its low latent heat, low critical pressure and well known properties. It has been found that the two-phase mixing coefficient depends mainly on mass flux. It increases with decreasing mass flux and ranges from 0.01 to 0.04 for the test conditions considered. More than 900 CHF data points have been obtained in a large range of parameters: pressure 1.0–3.0 MPa and mass flux 1.0–6.0 Mg/m2s. The effect of different parameters on CHF has been analysed. It has been found that the effect of pressure, mass flux and vapour quality on CHF is similar to that observed in circular tubes. Nevertheless, the CHF in the tight rod bundle is much lower than that in a circular tube of the same equivalent hydraulic diameters. The effect of wire wraps on CHF is mainly dependent on local vapour qualities and subsequently on flow regimes. Based on subchannel flow conditions, the effect of radial power distribution on CHF is small. Comparison of the test results with CHF prediction methods underlines the need for further work.  相似文献   

2.
Experimental and theoretical investigations have been performed on critical heat flux (CHF) and turbulent mixing in tight, hexagonal, 7-rod bundles. Freon-12 was used as working fluid due to its low latent heat, low critical pressure and well known properties. It has been found that the two-phase mixing coefficient depends mainly on mass flux. It increases with decreasing mass flux and ranges from 0.01 to 0.04 for the test conditions considered. More than 900 CHF data points have been obtained in a large range of parameters: pressure 1.0–3.0 MPa and mass flux 1.0–6.0 Mg/m2s. The effect of different parameters on CHF has been analysed. It has been found that the effect of pressure, mass flux and vapour quality on CHF is similar to that observed in circular tubes. Nevertheless, the CHF in the tight rod bundle is much lower than that in a circular tube of the same equivalent hydraulic diameters. The effect of wire wraps on CHF is mainly dependent on local vapour qualities and subsequently on flow regimes. Based on subchannel flow conditions, the effect of radial power distribution on CHF is small. Comparison of the test results with CHF prediction methods underlines the need for further work.  相似文献   

3.
The transient critical heat flux (CHF) experiments with forced sinusoidal inlet flow oscillation (oscillation period in 1–11 s, normalized amplitude of inlet flow oscillation in 0–3.0) were conducted in a vertical tube under low pressure condition. To analyze the triggering mechanism and aftermath of periodic dryout, the wall temperature fluctuation characteristics at the onset of periodic dryout and during post-periodic dryout were investigated. Under inlet flow oscillation condition, periodic dryout would be triggered at the wave trough of liquid film oscillation as wall heat flux far below the stable-flow CHF. The transient periodic dryout would give rise to temperature fluctuations on the tube wall, the amplitude of which increased with oscillation period and heat flux. The large wall temperature fluctuation during long-playing periodic dryout could significantly pre-trigger continuous dryout. The changing trends of the periodic dryout heat flux show a reasonable agreement with Okawa’s theoretical model, in which the liquid film oscillation was supposed be weakened by the axial mixing of liquid film. Moreover, the droplet entrainment at the oscillatory interface also has noticeable influence on the oscillation characteristics of liquid film. Based on the analysis of parameter effects on periodic dryout, a semi-empirical correlation was proposed to predict the periodic dryout heat flux under inlet flow oscillation condition.  相似文献   

4.
The influence of test section orientation and diameter on flow boiling crisis occurring in tubes has been studied experimentally using Freon-12 as a coolant. At low mass flux the critical heat flux (CHF) was lower in horizontal flow than in vertical. As either the liquid or vapour velocity, or both, were increased the vertical and horizontal CHF results converged. Above a mass flux of 4Mg · m−2 · s−1 the results were essentially identical.

The effect of tube diameter on boiling crisis in general depends crucially on the parameters which are maintained constant when the comparison is made.  相似文献   


5.
An experimental study was conducted to measure the critical axial heat flux in countercurrent two phase flow of liquid and its vapour in a closed-end vertical tube. The experimental results for four different fluids; carbon-tetrachloride, normal hexane, ethyl alcohol and water, were reduced to give a correlation for evaluation of the flooding critical heat flux. Results of other investigators on vertical heated tubes and vertical thermosyphons were also reduced and compared with the present experimental results. The effect of the density ratio of liquid to its vapour on the critical heat flux was shown. The length to diameter ratio of the test section was shown to have an influence on the flooding critical heat flux and was included in the correlation obtained.  相似文献   

6.
Critical heat flux (CHF) experiments using deionized water as working fluid have been conducted in a range of pressure from 0.6 to 4.2 MPa, mass flow velocity from 60 to 130 kg/ms and wall heat flux from 10 to 90 kW/m2 for vertical narrow annuli with annular gap sizes of 0.95 and 1.5 mm. We found that the CHF, occurring only on the inside tube, or on the outside tube or on both tubes of the annular channel, depends on the heat flux ratio between surfaces of the outside and inside tubes. The CHF, occurring on the surface of the inside tube, reaches the maximum value under the pressure of 2.3 MPa while it occurring on the surface of the outside tube keeps increasing with the increase of the pressure. The CHF, occurring on the inside or outside tubes, increases with the increase of the mass flow velocity and the annular gap size; and decreases with the increase of critical quality and the other tube wall heat flux. Empirical correlations, which agree quite well with the experimental data, have been developed to predict the CHF occurring on surfaces of the inside or outside tubes of the narrow annular channel on the conditions of low pressure and low flow.  相似文献   

7.
Experimental study of critical heat flux in open two-phase thermosyphon   总被引:1,自引:0,他引:1  
Critical heat flux in an open two-phase thermosyphon has been measured employing water, R113 and R22 for a wide range ofL/D=4.8 to 960 and density ratio ofρ L G =6.17 to 1602. The CHF data measured, are found to be in fairly good agreement with those calculated from a criterion that the CHF takes place when reaches a maximum liquid falling rate in counter-current annular flow of liquid and vapor. Normal operation of the thermosyphon cannot be obtained at any liquid of water, R113 and R22 for a small tube diameter of less than 2 mm.  相似文献   

8.
An improved version of the author's earlier correlation for CHF in vertical tubes is presented. It is compared with data that include 23 fluids (water, refrigerants, cryogens, chemicals, and liquid metals), tube diameters 0.315 to 37.5 mm, tube length 1.3 to 940 times diameter, mass flux 4 to 29051 kg/m2s, reduced pressures 0.0014 to 0.96, inlet quality −4 to +0.85, and critical quality −2.6 to +1. These data, from 62 independent sources, are also compared with Katto's general correlation and those of Bowring for water and Subbotin for helium. The present correlation shows much better agreement with data.  相似文献   

9.
An analytical study is made of the critical axial heat flux in heated closed end vertical tubes in the case of small length to diameter ratios. An expression for the critical heat flux is obtained and its dependency on the dimensionless diameter is shown. Results are compared with the previous analysis for large length to diameter ratios and the available experimental data on vertical closed end tubes, vertical thermosyphons and wickless heat pipes. A high degree of consistancy between the present analysis and these experiments is obtained.  相似文献   

10.
11.
Critical heat flux during pool boiling on a vertical heater of wire or plate has been measured employing water and R113. The experiment was made for a wire of 0.5 to 2 mm in diameter and for a plate of 5, 7 and 30 mm in width and from 20 to 300 mm in height. The pressure was 1 and 2 bar for water and 1, 2, 3 and 4 bar for R113. The experiment shows that for the case of both wire and plate of 5, 7 mm, a large coalesced bubble entirely surrounds the vertical heater and rises surrounding it, while for the case of w = 30 mm, a large bubble cannot surround and rises along its surface. The characteristic of CHF can be divided into two regimes depending on the flow condition when CHF takes place. Correlations are proposed for the CHF of the wire and the plate of w = 5, and 7 mm, yielding good accuracy. The CHF for the plate of w = 30 mm has a similar tendency to that in one side headed surface and can be predicted reasonably by existing correlation for one side heated surface.  相似文献   

12.
The fact that heat is transferred into a heat pipe through the liquid-saturated evaporator wick gives rise to the so-called boiling limit on the heat pipe capacity. The composite nature of the double-wall artery heat pipe (DWAHP) wick structure makes the prediction of the evaporator superheat (Δ Tcrit) and the critical radial heat flux (qr) very difficult. The effective thermal conductivity of the wick, the effective radius of critical nucleation cavity, and the nucleation superheat, which are important parameters for double-wall wick evaporator heat transfer, have been evaluated based on the available theoretical models. Empirical correlations are used to corroborate the experimental results of the 2 m DWAHP. A heat choke mounted on the evaporator made it possible to measure the evaporator external temperatures, which were not measured in the previous tests. The high values of the measured evaporator wall temperatures are explainable with the assumption of a thin layer of vapor blanket at the inner heating surface. It has been observed that partial saturation of the wick (lean evaporator) causes the capillary limit to drop even though it may be good for efficient convective heat transfer through the wick. The 2 m long copper-water heat pipe had a peak performance of 1850 W at 23 W/cm2 with a horizontal orientation.  相似文献   

13.
14.
Enhancement of the critical heat flux in pool boiling by the attachment of a honeycomb-structured porous plate on a heated surface is investigated experimentally using water under saturated boiling conditions. As the height of the honeycomb porous plate on the heated surface decreases, the CHF increases to 2.5 MW/m2, which is approximately 2.5 times that of a plain surface (1.0 MW/m2). Automatic liquid supply due to capillary action and reduction of the flow resistance for vapor escape due to the separation of liquid and vapor flow paths by the honeycomb-structure are verified to play an important role in the enhancement of the CHF. A simplified one-dimensional model for the capillary suction limit, in which the pressure drops due to liquid and vapor flow in the honeycomb porous plate balances the capillary force, is applied to predict the CHF. The calculated results are compared with the measured results.  相似文献   

15.
Porous media has been widely applied to enhance boiling heat transfer in industry, especially for increasing the value of critical heat flux (CHF). Two cases were considered in the paper: boiling within porous bed and boiling above on porous coatings. For boiling within porous bed, simplified Rayleigh–Taylor stability was analyzed and parametric effects of porous media on boiling critical heat flux were revealed. For boiling above on porous coatings, a simple new critical heat flux model was proposed basing on the analysis of liquid film stability and parametric effect of porous coatings on CHF was elaborated.  相似文献   

16.
The adaptation of a calculation method for critical heat flux using an annular flow model is described. If the swirl is assumed to deposit all the entrained drops onto the liquid film and to persist for a certain distance after the swirl device, good comparisons with experiment are obtained. A simple method for calculating the length over which the swirl persists is given.  相似文献   

17.
The effects of ultrasonic vibration on critical heat flux (CHF) have been experimentally investigated under natural convection condition. Flat bakelite plates coated with thin copper layer and distilled water are used as heated specimens and working fluid, respectively. Measurements of CHF on flat heated surface were made with and without ultrasonic vibration applied to working fluid. An inclination angle of the heated surface and water subcooling are varied as well. Examined water subcoolings are 5°C, 20°C, 40°C and the angles are 0°, 10°, 20°, 45°, 90°, 180°. The measurements show that ultrasonic wave applied to water enhances CHF and its extent is dependent upon inclination angle as well as water subcooling. The rate of increase in CHF increases with an increase in water subcooling while it decreases with an increase in inclination angle. Visual observation shows that the cause of CHF augmentation is closely related with the dynamic behaviour of bubble generation and departure in acoustic field.  相似文献   

18.
19.
The characteristics of the critical heat flux (CHF) for downward flow were studied experimentally with an Inconel 600 circular tube test section in a water test loop at low-flow rate (0 200 kg/m2s) and low-pressure (0.1 0.7 MPa) conditions. The attention was given to the effects of upstream conditions—upper plenum and inlet throttling. Two totally different kinds of CHF behaviors were observed. It seems appropriate to interpret them as flooding-type CHF and dryout in annular flow. The CHF in downward flow may vary from extremely unstable flow CHF as low as near the flooding CHF value to stable flow CHF as high as that of upflow, depending on the upstream conditions of the test section. The CHF correlation by Mishima and that by Weber were proposed for the presentation of the lower and upper limits of the CHF for downward flow in a vertical tube at low-flow rate and low-pressure conditions.  相似文献   

20.
 The laminar and parallel flow of a Newtonian fluid in a vertical cylindrical duct with circular cross section has been analysed. Both the viscous dissipation effect and the buoyancy effect have been taken into account. The momentum balance equation and the energy balance equation have been solved by means of a perturbation method, in the case of a uniform heat flux prescribed at the wall of the duct. The velocity distribution, the temperature distribution, the Nusselt number and the Fanning friction factor have been evaluated analytically. Moreover, the velocity and temperature of the fluid have been compared with those obtained in two special cases: forced convection with viscous dissipation (i.e. negligible buoyancy effect); mixed convection with negligible effects of viscous dissipation. Received on 26 June 2000  相似文献   