首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 312 毫秒
1.
The feasibility of solid-phase microextraction (SPME) for the determination of several organophosphorus flame retardants and plastizicers in water samples by gas chromatography-nitrogen phosphorous detection (GC-NPD) is evaluated. These compounds have a wide range of polarities and volatilities and require a thorough optimisation of the different SPME parameters. Considering also possible contamination and carryover sources, the best compromise microextraction conditions were found to be direct extraction of 22 ml samples, containing 300 mg/ml of NaCl, with a PDMS-DVB coated fibre at room temperature. Although equilibrium was not achieved, an extraction time of 40 min allowed obtaining a good sensitivity (quantification limits between 0.010 and 0.025 ng/ml), comparable to that achieved by solid-phase extraction (SPE) of 1l samples, producing both similar values of precision and accuracy. Furthermore, the SPME method has shown to be free of matrix effects, avoiding the need of employing the standard addition procedure for quantification, and was suitable for the determination of eight of the nine considered compounds. Only tris-(2-ethylhexyl)-phosphate was neither determinable by SPME nor by SPE. Finally, the application of the developed methodology to the analysis of wastewater samples, showed that important concentrations of these compounds (up to 10 ng/ml) have been detected in treated sewage water, being discharged into the aquatic environment.  相似文献   

2.
Despite the continuing development of SPME (solid-phase microextraction) fibre coatings, their selection presents some difficulties for analysts in choosing the appropriate fibre for a certain application. There are two distinct types of SPME coatings available commercially. The most widely used are poly(dimethylsiloxane) (PDMS) and poly(acrylate) (PA). Supelco has developed new mixed phases consisting of porous polymer particles, either poly(divinylbenzene) (DVB) or Carboxen suspended in a matrix of PDMS or Carbowax for extracting analytes via adsorption. In addition to the nature of the extracting phase, the thickness of the polymeric film must be taken into account and, surprisingly, the construction of the fibres when apparently they bear the same coating, as it is the case of the three PDMS-DVB fibres available. Other fibre structure properties not well explored were identified and must be taken into consideration. To elucidate their extraction efficiency, three PDMS-DVB fibres, namely 60 microm for HPLC use, 65 microm for GC use and 65 microm StableFlex for GC use, were compared with regard to the extraction of 36 compounds included in four pesticide groups. The first was particularly suited for the extraction of organophosphorus pesticides and triazines whereas the StableFlex exhibited advantages in the analysis of organochlorine pesticides and pyrethroids. An explanation for the extraction differences is suggested based on the different structure of the fibres. Detection limits in the range of 1-10 ng/l for organochlorine pesticides, 1-30 ng/l for organophosphorus pesticides, 8-50 ng/l for triazines and 10-20 ng/l for pyrethroids were attained in a method using the 60 microm PDMS-DVB fibre. The fibre maintains its performance at well above 100 extractions with between-day precision below 10%.  相似文献   

3.
A simple and fast method based on solid-phase microextraction (SPME) followed by fast gas chromatography (Fast GC) has been developed for the analysis of volatile compounds in Asturian apple juices employed in the cider production. Three different fiber coatings have been checked (PDMS, PDMS-DVB and CAR-PDMS) and PDMS-DVB has been presented to be the most suitable one. Experimental design has been employed in the optimization of extraction factors and robustness assessment. The use of Fast GC allowed the separation of 14 compounds (esters, aldehydes and alcohols) in approximately 4 min, clearly reducing the analysis time when compared to conventional GC. Good linearity, recoveries and repeatability of the solid-phase microextraction were obtained with r(2) values, recoveries and relative standard deviations ranging from 0.9822 to 0.9998, 83.2 to 109.8% and 0.5 to 11.7%, respectively, using standard solution.  相似文献   

4.
A common sample preparation procedure capable of efficiently concentrating various groups of pesticides, taking advantage of universal detectors like the mass spectrometer or combined techniques of group selective detectors like gas chromatography-electron capture detection (ECD)/thermionic specific detection (TSD), is desirable in environmental analysis. Six solid-phase microextraction fibres available for analysis of semi-volatiles (7, 30 and 100 microm poly(dimethylsiloxane) (PDMS), 85 microm polyacrylate, 60 microm PDMS-divinylbenzene (PDMS-DVB) and 65 microm Carbowax-DVB) were evaluated and the 60 microm PDMS-DVB was selected for the simultaneous extraction of 34 compounds, included in the organochlorine (OCPs), organophosphorous (OPPs), pyrethroid and triazine pesticide groups. All parameters affecting the extraction efficiency from water samples, namely fibre coating, sample agitation, pH and ionic strength, extraction temperature and time, were optimised. The analytical procedure involves solid-phase microextraction extraction, gas chromatographic separation and subsequent ECD and TSD via a post-column splitter adjusted to a split ratio of 1:10, respectively. Detection limits in the range of 1-10 ng l(-1) for OCPs, 1-30 ng l(-1) for OPPs, 20-30 ng l(-1) for pyrethroids and 8-50 ng l(-1) for triazines are easily attainable with the optimised procedure. The method validated for ground and drinking waters has low cost of implementation and operation although it requires careful maintenance.  相似文献   

5.
The aroma profile of cocoa products was investigated by headspace solid-phase micro-extraction (HS-SPME) combined with gas chromatography–mass spectrometry (GC–MS). SPME fibers coated with 100 μm polydimethylsiloxane coating (PDMS), 65 μm polydimethylsiloxane/divinylbenzene coating (PDMS-DVB), 75 μm carboxen/polydimethylsiloxane coating (CAR-PDMS) and 50/30 μm divinylbenzene/carboxen on polydimethylsiloxane on a StableFlex fiber (DVB/CAR-PDMS) were evaluated. Several extraction times and temperature conditions were also tested to achieve optimum recovery. Suspensions of the samples in distilled water or in brine (25% NaCl in distilled water) were investigated to examine their effect on the composition of the headspace. The SPME fiber coated with 50/30 μm DVB/CAR-PDMS afforded the highest extraction efficiency, particularly when the samples were extracted at 60 °C for 15 min under dry conditions with toluene as an internal standard. Forty-five compounds were extracted and tentatively identified, most of which have previously been reported as odor-active compounds. The method developed allows sensitive and representative analysis of cocoa products with high reproducibility. Further research is ongoing to study chocolate making processes using this method for the quantitative analysis of volatile compounds contributing to the flavor/odor profile.  相似文献   

6.
Headspace solid-phase microextraction (HS-SPME) coupled to gas chromatography with ion trap mass spectrometric detection and with atomic emission detection (GC-AED) was employed to identify possible odor-impact volatile organic compounds in cupuassu (Theobroma grandiflorum Spreng) liquor, as well as to quantify alkylpyrazines present in these samples. SPME fibers coated with 100 microm polydimethylsiloxane (PDMS), 65 microm PDMS-divinylbenzene (DVB) and 75 microm Carboxen (CAR)-PDMS were tested, the later being chosen for the optimized extraction procedure. The principal compounds found in the sample headspace were 3-methylbutanal, dimethylsulfide, dimethyldisulfide, beta-linalool and several alkylpyrazines (notably tetramethylpyrazine). The procedure for quantitation of the alkylpyrazines, using GC-AED for their separation and detection, allowed the detection of microg g(-1) levels of the analytes in the samples, with acceptable precision (R.S.D. less than 10%).  相似文献   

7.
建立了一种快速简便地测定酱油中挥发性风味成分的顶空固相微萃取(HS-SPME)-气相色谱-质谱法(GC-MS)。以2-辛醇为内标,考察了萃取头、萃取时间、离子强度、萃取温度对酱油样品中挥发性风味物质萃取的影响。该方法对酱油中常见挥发性风味成分的测定有良好的重复性和回收率,对常见挥发性物质的定量比较准确。优化的HS-SPME条件为:涂层厚度为85 μm聚丙烯酸酯(PA)萃取纤维头,于45 ℃、NaCl质量浓度为250 g/L下对酱油样品顶空吸附40 min,于250 ℃下解吸2 min后进行GC-MS分离鉴定。酱油样品的分析结果表明,其挥发性风味物质中含量较高的是醇、酸、酯和酚类,此外还有一些羰基化合物和杂环化合物。  相似文献   

8.
Optimum conditions for headspace solid-phase microextraction (HS-SPME) in the analysis of monomethylmercury (MeHg) have been determined. Sodium tetra(n-)propylborate (NaBPr(4)) is used as derivatization reagent to promote volatility. A simple aluminium bar was used to cool the SPME fiber to about 2 degrees C during the equilibration phase just before extraction. HS-SPME was performed using different fibers. The 100 microm polydimethylsiloxane (PDMS) and 65 microm polydimethylsiloxane-divinylbenzene (PDMS-DVB) fibers showed the best results. Although the extraction efficiency for MeHg derivative of the polydimethylsiloxane-Carboxen (PDMS-CAR) fiber is similar to the other fibers, desorption of MeHg derivative from a PDMS-CAR fiber is poor. Factors affecting the HS-SPME process such as adsorption and desorption times, ionic strength (salting-out) and extraction temperature have been evaluated and optimized thoroughly. The highest extraction efficiency for the PDMS fiber was obtained by extraction at a low temperature (2 degrees C) immediately after equilibration at 30 degrees C. With the PDMS-DVB and PDMS-CAR fiber improvement of extraction efficiency at lower temperatures is negligible. Repeated extraction out of the same vial revealed that about 30% of MeHg derivative is extracted from the headspace with a PDMS fiber at 2 degrees C and about 70% with a PDMS-DVB fiber. Repeated extraction with two different fiber coatings showed that the PDMS-CAR fiber also extracts about 70% but that the desorption is incomplete. Attempts to improve the desorption failed due to degradation of the MeHg derivate at high injection temperatures. The limit of detection (3sigma) was 16 pg/L MeHg. The relative standard deviation (n = 8) for 100 pg/L of MeHg was found to be 5%. Linearity of the HS-SPME-GC-atomic emission detection method was established over at least two orders of magnitude in the range 0-2000 pg/L. Recovery of a surface water sample spiked at 2 ng/L was 85%. The suitability of the procedure was demonstrated by analysis of a surface water sample that showed a concentration of 100 pg/L MeHg. The optimized method can be used with standard commercial equipment without further adaptations.  相似文献   

9.
Synthetic musks are extensively used as fragrance components in a wide range of consumer and personal care products such as detergents, shampoos, perfumes and other cosmetic products. Amongst them, galaxolide and tonalide have become ubiquitous pollutants due to their continuous releasing into the environment. Because of their nature as artificial fragrances, inhalation should be considered as an important exposure pathway, especially in indoor environments. However, up to now very few studies have been carried out to determine these emergent pollutants indoors. In this work, a simple and highly sensitive methodology for the analysis of synthetic musk fragrances in indoor air samples is presented. The proposed methodology combines solid-phase extraction (SPE) and solid-phase microextraction (SPME), followed by gas chromatography-mass spectrometry (GC/MS). To the best of our knowledge, this is the first method based on SPME for the analysis of musks in air. By active sampling, musks present in air were adsorbed onto 25mg Tenax and then transferred to a SPME fiber in the headspace mode (HS). An experimental design strategy was used to optimize main factors potentially affecting the microextraction process such as fiber coating, temperature and the addition of a microvolume of organic solvent to the solid sorbent prior to SPME. Breakthrough of the SPE sorbent was studied from 1 to 10m(3) without significant losses. Recovery studies were performed at two concentration levels (2 and 20ngm(-3)), obtaining quantitative recoveries (>/=85%) by external calibration. A comprehensive study was performed in order to estimate the limits of detection taking into account the contamination risks and laboratory blanks. Values at the sub ngm(-3) level were achieved for all the target compounds sampling 5m(3) air. External calibration, not requiring the complete sampling process, demonstrated to be suitable for the quantification of all musk compounds. Finally, several indoor environments were analyzed using the proposed method.  相似文献   

10.
This study develops a method for the analysis of biocides Irgarol 1051 and Sea Nine 211 in environmental water samples, using solid-phase microextraction (SPME). Their determination was carried out using gas chromatography with flame thermionic (FTD), electron-capture (ECD) and mass spectrometric detection. The main parameters affecting the SPME process such as adsorption-time profile, salt additives and memory effect were studied for five polymeric coatings commercially available for solid-phase microextraction: poly(dimethylsiloxane) (100 and 30 microm), polyacrylate, poly(dimethylsiloxane)-divinylbenzene (PDMS-DVB 65 microm) and Carbowax-divinylbenzene (65 microm). The method was developed using spiked natural waters such as tap, river, sea and lake water in a concentration range of 0.5-50 microg/l. All the tested fiber coatings have been evaluated with regard to sensitivity, linear range, precision and limits of detection. Typical RSD values (triplicate analysis) in the range of 3-10% were obtained depending on the fiber coating and the compound investigated. The recoveries of biocides were in relatively high levels 60-118% and the calibration curves were reproducible and linear (R2>0.990) for both analytes. The SPME partition coefficients (Kf) of both compounds were also calculated experimentally in the proposed conditions for all fibers using direct sampling. Finally the influence of organic matter such as humic acids on extraction efficiency was studied, affecting mostly Sea Nine 211 uptake by the fiber. Optimum analytical SPME performance was achieved using the PDMS-DVB 65 microm fiber coating in ECD and FTD systems for Sea Nine 211 and Irgarol 1051, respectively.  相似文献   

11.
This paper deals with comparison of efficiency of extraction techniques (solid-phase extraction, SPE and solid-phase microextraction, SPME) used for extraction of nitrate esters (ethyleneglycoldinitrate, EGDN and nitroglycerin, NG), representing the first step of the method of quantitative determination of trace concentrations of nitrate esters in water samples. EGDN and NG are subsequently determined by means of high-performance liquid chromatography with ultraviolet detection (HPLC-UV). Optimization of SPE and SPME conditions was carried out using model water samples. Seven SPE cartridges were tested and the conditions were optimized (type of sorbent, type and volume of solvent to be used as eluent). For both nitrate esters the limit of detection (LOD) and the limit of quantification (LOQ) obtained using SPE/HPLC-UV were 0.23 microg mL(-1) and 0.70 microg mL(-1), respectively. Optimization of SPME conditions: type of SPME fibre (four fibres were tested), type and time of sorption/desorption, temperature of sorption. PDMS/DVB (polydimethylsiloxane/divinylbenzene) fibre coating proved to be suitable for extraction of EGDN and NG. For this fibre the LOD and the LOQ for both nitrate esters were 0.16 microg mL(-1) and 0.50 microg mL(-1), respectively. Optimized methods SPE/HPLC-UV and SPME/HPLC-UV were then used for quantitative determination of nitrate esters content in real water samples from the production of EGDN and NG.  相似文献   

12.
Coupling headspace solid-phase microextraction (HS-SPME) and low-pressure gas chromatography-tandem mass spectrometry (LP-GC-MS-MS) has been used for determining 20 volatile compounds present in flowers. HS-SPME coupled with LP-GC-MS-MS acts in a synergic way allowing a fast extraction and analysis of the target compounds. The method has been optimised studying the influence of the adsorption temperature and adsorption time. The best results were obtained heating the SPME vials at 60 degrees C for 5 min using 65 microm poly(dimethylsiloxane-divinylbenzene) fibers. The validation of the method ensures the fitness for the purpose of the analytical method, achieving appropriate lower limits, recoveries and precision. The analytical method has been applied to the characterisation of zucchini flowers fragrances in air using passive sampling, in order to improve our knowledge on zucchini fragrances and to better pollination technique in future steps.  相似文献   

13.
The preparation and characteristics of solid-phase microextraction (SPME) fibers coated with Carbowax 20M ormosil (organically modified silica) are described here. Raw fused silica fibers were coated with Carbowax 20M-modified silica using sol-gel process. Scanning electron micrographs of fibers revealed a highly porous, sponge-like coating with an average thickness of (8 +/- 1) microm. The sol-gel Carbowax fibers were compared to commercial fibers coated with 100 microm polydimethylsiloxane (PDMS) and 65 microm Carbowax-divinylbenzene (DVB). Shorter equilibrium times were possible with the sol-gel Carbowax fiber: for headspace extraction of the test analytes, they ranged from less than 3 min for benzene to 15 min for o-xylene. Extraction efficiencies of the sol-gel Carbowax fiber were superior to those of conventional fibers: for o-xylene, the extracted masses were 230 and 540% of that obtained with 100 microm PDMS and 65 microm Carbowax-DVB fibers, respectively.  相似文献   

14.
Blended Scotch whisky was analysed by solid-phase microextraction (SPME) and stir bar sorptive extraction (SBSE) to study the composition of the volatiles. For SPME analysis, three different fibres were compared, poly(dimethylsiloxane) (PDMS) (100 microm). poly(acrylate) (PA) (85 microm) and divinylbenzene-Carboxen on poly(dimethylsiloxane) (DVB-CAR-(PDMS) (50/30 microm). It was found that the PDMS and DVB-CAR-PDMS fibres showed a higher enrichment capacity than PA as well as a better reproducibility. The influence of sampling time, temperature and salt addition on the enrichment of volatiles as well as the difference between liquid and headspace SPME were studied. An optimum SPME method was developed. Finally a more recent sample preparation technique, namely SBSE was evaluated to extract whisky volatiles.  相似文献   

15.
A solid-phase microextraction method (SPME) for determining trace levels of synthetic musk fragrances in residual waters has been developed. Six polycyclic musks (cashmeran, phantolide, celestolide, traseolide, galaxolide and tonalide), and a macrocyclic musk (ambrettolide) have been analysed. A detailed study of the different parameters affecting the extraction process is presented. The main important factors affecting the microextraction process have been studied and optimised by means of a categorical factorial design. Two extraction modes (direct SPME and headspace SPME) were tried at different extraction temperatures using four different fiber coatings [polydimethylsiloxane (PDMS), Carboxen (CAR)-PDMS, PDMS-divinylbenzene (DVB) and Carbowax (CW)-DVB]. An extraction temperature of 100 degrees C sampling the headspace over the sample using CAR-PDMS or PDMS-DVB as fiber coatings were found to be the experimental conditions that lead to a more effective extraction. The method proposed is very simple and yields high sensitivity, with detection limits in the low pg/ml, good linearity and repeatability for all the target compounds. The total analysis time, including extraction and GC analysis, was only 45 min. The optimised method performed well when it was applied to waste water from an urban treatment plant.  相似文献   

16.
A solid-phase microextraction method has been developed for the determination of 19 chlorophenols (CPs) in environmental samples. The analytical procedure involves direct sampling of CPs from water using solid-phase microextraction (SPME) and determination by liquid chromatography with electrochemical detection (LC-ED). Three kinds of fibre [50 microm carbowax-templated resin (CW-TPR), 60 microm polydimethylsiloxane-divinylbenzene (PDMS-DVB) and 85 microm polyacrylate (PA)] were evaluated for the analysis of CPs. Of these fibres, CW-TPR is the most suitable for the determination of CPs in water. Optimal conditions for both desorption and absorption SPME processes, such as composition of the desorption solvent (water-acetonitrile-methanol, 20:30:50) and desorption time (5 min), extraction time (50 min) and temperature (40 degrees C) as well as pH (3.5) and ionic strength (6 g NaCl) were established. The precision of the SPME-LC-ED method gave relative standard deviations (RSDs) of between 4 and 11%. The method was linear over three to four orders of magnitude and the detection limits, from 3 to 8 ng l(-1), were lower than the European Community legislation limits for drinking water. The method was applied to the analysis of CPs in drinking water and wood samples.  相似文献   

17.
Pontes M  Marques JC  Câmara JS 《Talanta》2007,74(1):91-103
The volatile composition from four types of multifloral Portuguese (produced in Madeira Island) honeys was investigated by a suitable analytical procedure based on dynamic headspace solid-phase microextraction (HS-SPME) followed by thermal desorption gas chromatography-quadrupole mass spectrometry detection (GC-qMS). The performance of five commercially available SPME fibres: 100 μm polydimethylsiloxane, PDMS; 85 μm polyacrylate, PA; 50/30 μm divinylbenzene/carboxen on polydimethylsiloxane, DVB/CAR/PDMS (StableFlex); 75 μm carboxen/polydimethylsiloxane, CAR/PDMS, and 65 μm carbowax/divinylbenzene, CW/DVB; were evaluated and compared. The highest amounts of extract, in terms of the maximum signal obtained for the total volatile composition, were obtained with a DVB/CAR/PDMS coating fibre at 60 °C during an extraction time of 40 min with a constant stirring at 750 rpm, after saturating the sample with NaCl (30%). Using this methodology more than one hundred volatile compounds, belonging to different biosynthetic pathways were identified, including monoterpenols, C13-norisoprenoids, sesquiterpenes, higher alcohols, ethyl esters and fatty acids. The main components of the HS-SPME samples of honey were in average ethanol, hotrienol, benzeneacetaldehyde, furfural, trans-linalool oxide and 1,3-dihydroxy-2-propanone.  相似文献   

18.
Extraction of dry cured ham volatile compounds by solid-phase microextraction (SPME) was optimized. Different fiber coatings (carboxen/polydimethylsiloxane (CAR/PDMS), divinylbenzene/carboxen/polydimethylsiloxane (DVB/CAR/PDMS), polydimethylsiloxane (PDMS), polydimethylsiloxane/divinylbenzene (PDMS/DVB)), times of extraction (15, 30, 60 min) and sample preparation (ground samples and homogenates with NaCl saturated solution) were assayed. CAR/PDMS and DVB/CAR/PDMS fiber coatings extracted more than 100 volatile compounds and showed the highest area counts for most volatile compounds. CAR/PDMS coating extracted better those compounds whose Kovats index (KI) was lower than 980 (on average) and DVB/CAR/PDMS those with higher KI. Fifteen minutes of extraction provided a volatile compound profile with lower area counts for most compounds and qualitatively different to that obtained with 30 and 60 min of extraction. Homogenates gave a different profile compared to ground samples, with lower total counts for most compounds but higher proportion of aldehydes, and presence of several compounds not found in ground samples.  相似文献   

19.
Headspace solid-phase microextraction combined with gas chromatography-ion trap tandem mass spectrometry (HS-SPME-GC-ITMS-MS) method has been developed and studied for the simultaneous determination of 15 organochlorine pesticides (OCPs) and 20 polychlorinated biphenyls (PCBs) in aqueous samples. To perform the HS-SPME polydimethylsiloxane (PDMS) (7, 30 and 100 microm film thickness) and polydimethylsiloxane-divinylbenzene (PDMS-DVB) fibers were initially compared on the basis of their absorption capacities for the selected compounds, and PDMS 100 microm film thickness was selected to accomplish the rests of essays. The influence of various parameters on OCPs and PCBs extraction efficiency by HS-SPME was thoroughly studied using GC-electron capture detector (ECD). Parameters such as collision induced dissociation (CID) resonant excitation amplitude and RF storage level were optimized to increase specificity and sensibility for ITMS-MS analysis. The performance of proposed HS-SPME-GC-ITMS-MS methodology with respect to linearity, reproducibility and limit of detection (LOD) was evaluated by water spiked with target compounds. The linear range of most compounds was found to be between 0.01 and 1 ng mL(-1) and the limits of detection were between 0.4 and 26 pg mL(-1). The reproducibility of the method (n = 6), expressed as relative standard deviation (RSD), was between 5 and 21%. Finally, developed procedure was applied to determine selected OCPs and PCBs in river water samples in concentration below 0.1 ng mL(-1) can be easily carried out with ultra-selectivity and precision.  相似文献   

20.
In the present study, a simple and sensitive methodology based on dynamic headspace solid-phase microextraction (HS-SPME) followed by thermal desorption gas chromatography with quadrupole mass detection (GC-qMSD), was developed and optimized for the determination of volatile (VOCs) and semi-volatile (SVOCs) compounds from different alcoholic beverages: wine, beer and whisky. Key experimental factors influencing the equilibrium of the VOCs and SVOCs between the sample and the SPME fibre, as the type of fibre coating, extraction time and temperature, sample stirring and ionic strength, were optimized. The performance of five commercially available SPME fibres was evaluated and compared, namely polydimethylsiloxane (PDMS, 100 μm); polyacrylate (PA, 85 μm); polydimethylsiloxane/divinylbenzene (PDMS/DVB, 65 μm); carboxen™/polydimethylsiloxane (CAR/PDMS, 75 μm) and the divinylbenzene/carboxen on polydimethylsiloxane (DVB/CAR/PDMS, 50/30 μm) (StableFlex).An objective comparison among different alcoholic beverages has been established in terms of qualitative and semi-quantitative differences on volatile and semi-volatile compounds. These compounds belong to several chemical families, including higher alcohols, ethyl esters, fatty acids, higher alcohol acetates, isoamyl esters, carbonyl compounds, furanic compounds, terpenoids, C13-norisoprenoids and volatile phenols. The optimized extraction conditions and GC-qMSD, lead to the successful identification of 44 compounds in white wines, 64 in beers and 104 in whiskys. Some of these compounds were found in all of the examined beverage samples.The main components of the HS-SPME found in white wines were ethyl octanoate (46.9%), ethyl decanoate (30.3%), ethyl 9-decenoate (10.7%), ethyl hexanoate (3.1%), and isoamyl octanoate (2.7%). As for beers, the major compounds were isoamyl alcohol (11.5%), ethyl octanoate (9.1%), isoamyl acetate (8.2%), 2-ethyl-1-hexanol (5.9%), and octanoic acid (5.5%). Ethyl decanoate (58.0%), ethyl octanoate (15.1%), ethyl dodecanoate (13.9%) followed by 3-methyl-1-butanol (1.8%) and isoamyl acetate (1.4%) were found to be the major VOCs in whisky samples.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号