首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
A deposition system capable of delivering picoliter quantities of solution in programmable arrays was investigated as a method for sample preparation for total reflection X-ray fluorescence (TXRF) spectroscopy. Arrays of trace metals in solution were deposited on Si wafers. The array deposits provide a capability of depositing closely spaced (100 μm or less), typically 5–20 μm diameter droplets in an area that can be matched to the analysis spot of the TXRF detector. The dried depositions were physically characterized and the effect of deposition type and matrix on the TXRF signal was investigated.  相似文献   

2.
A new technique for the deposition of standard solutions on particulate aerosol samples using pico-droplets for elemental determinations with total reflection X-ray fluorescence spectrometry (TXRF) is described. It enables short analysis times without influencing the sample structure and avoids time consuming scanning of the sample with the exciting beam in SR-TXRF analysis. Droplets of picoliter volume (∼ 5–130 pL) were generated with commercially available and slightly modified inkjet printers operated with popular image processing software. The size of the dried droplets on surfaces of different polarity namely silicone coated and untreated quartz reflectors, was determined for five different printer types and ten different cartridge types. The results show that droplets generated by inkjet printers are between 50 and 200 μm in diameter (corresponding to volumes of 5 to 130 pL) depending on the cartridge type, which is smaller than the width of the synchrotron beam used in the experiments (< 1 mm at an energy of 17 keV at the beamline L at HASYLAB, Hamburg). The precision of the printing of a certain amount of a single element standard solution was found to be comparable to aliquoting with micropipettes in TXRF, where for 2.5 ng of cobalt relative standard deviations of 12% are found. However, it could be shown that the printing of simple patterns is possible, which is important when structured samples have to be analysed.  相似文献   

3.
Pinhole-free palladium/nickel (Pd/Ni) alloy membranes deposited on a porous stainless steel (SUS) support have been fabricated. The deposition was made by vacuum electrodeposition technique which could produce the alloy film less than 1 μm thick. This technique allows for the Pd/Ni alloy by employing Pd/Ni complex reagent, and typical Pd/Ni plating had compositions of 78% Pd and 22% Ni. In order to make the surface smooth and enhance the adhesive bond between the top layer and the substrate, a nascent porous SUS disk was treated sequently with submicron nickel powder and CuCN solution. The important parameters that can affect deposition were pore size, defects, and surface roughness of substrate. The membranes were characterized by permeation experiments with hydrogen and nitrogen at temperatures ranging from 623 to 823 K and pressures from 10.3 to 51.7 cmHg. The composite membranes prepared in this technique yielded excellent separation performance for hydrogen: hydrogen permeance of 5.79×10−2 cm3/cm2 cmHg s and hydrogen/nitrogen (H2/N2) selectivity was 4700 at 823 K.  相似文献   

4.
A cost-effective successive ionic layer adsorption and reaction (SILAR) method was used to deposit copper (I) thiocyanate (CuSCN) thin films on glass and steel substrates for this study. The deposited thin films were characterized for their structural, morphological, optical and electrochemical properties using X-ray diffraction (XRD), scanning electron microscopy (SEM), UV–visible spectroscopy and VersaSTAT potentiostat. A direct band gap of 3.88 eV and 3.6 eV with film thickness of 0.7 μm and 0.9 μm was obtained at 20 and 30 deposition cycles respectively. The band gap, microstrain, dislocation density and crystal size were observed to be thickness dependent. The specific capacitance of the CuSCN thin film electrode at 20 mV/s was 760 F g−1 for deposition 20 cycles and 729 F g−1 for deposition 30 cycles.  相似文献   

5.
Selenium is essential for many aspects of human health and, thus, the object of intensive medical research. This demands the use of analytical techniques capable of analysing selenium at low concentrations with high accuracy in widespread matrices and sometimes smallest sample amounts.In connection with the increasing importance of selenium, there is a need for rapid and simple on-site (or near-to-site) selenium analysis in food basics like wheat at processing and production sites, as well as for the analysis of this element in dietary supplements. Common analytical techniques like electrothermal atomic absorption spectroscopy (ETAAS) and inductively-coupled plasma mass spectrometry (ICP-MS) are capable of analysing selenium in medical samples with detection limits in the range from 0.02 to 0.7 μg/l. Since in many cases less complicated and expensive analytical techniques are required, TXRF has been tested regarding its suitability for selenium analysis in different medical, food basics and dietary supplement samples applying most simple sample preparation techniques.The reported results indicate that the accurate analysis of selenium in all sample types is possible. The detection limits of TXRF are in the range from 7 to 12 μg/l for medical samples and 0.1 to 0.2 mg/kg for food basics and dietary supplements. Although this sensitivity is low compared to established techniques, it is sufficient for the physiological concentrations of selenium in the investigated samples.  相似文献   

6.
The present area of study is located in the Upper Course of the Lerma River (UCLR). The Lerma is one of the most important rivers of Mexico, where it drains highly populated and industrialized regions. The aim of the present study is to determine the heavy metal concentration of Cr, Mn, Fe, Cu and Pb in dissolved and total phases of the UCLR by means of Total Reflection X-ray Fluorescence Spectrometry (TXRF). The surface water samples were collected at 8 sites distributed following the stream flow direction of the river. Four sampling campaigns were carried out in each site in a 1-year period. A sample preparation method was applied in order to obtain the total and dissolved fraction and to destroy the organic matter. The total heavy metal average concentration decrease in the following order: Fe (2566 μg/L) > Mn (300 μg/L) > Cu (66 μg/L) > Cr (21 μg/L) > Pb (15 μg/L). In general, the heavy metal concentrations in water of the UCLR are below the maximum permissible limits.  相似文献   

7.
Aerosol flame pyrolysis deposition method was applied to deposit the oxide glass electrolyte film and LiCoO2 cathode for thin film type Li-ion secondary battery. The thicknesses of as-deposited porous LiCoO2 and Li2O–B2O3–P2O5 electrolyte film were about 6 μm and 15 μm, respectively. The deposited LiCoO2 was sintered for 2 min at 700 °C to make partially densified cathode layer, and the deposited Li2O–P2O5–B2O3 glass film completely densified by the sintering at 700 °C for 1 h. After solid state sintering process the thicknesses were reduced to approximately 4 μm and 6 μm, respectively. The cathode and electrolyte layers were deposited by continuous deposition process and integrated into a layer by co-sintering. It was demonstrated that Aerosol flame deposition is one of the good candidates for the fabrication of thin film battery.  相似文献   

8.
Hyaluronic acid (HYH) films were prepared from aqueous sodium hyaluronate (HYNa) solutions by anodic electrodeposition. The film thickness was varied in the range of 0–20 μm by the variation of the deposition time and HYNa concentration. The deposition rate was low at HYNa concentration below 1 g L−1 and increased significantly in the range of 3–5 g L−1. The addition of bovine serum albumin (BSA) to the HYNa solutions resulted in increased deposition yield, which was attributed to the formation of composite HYH–BSA films. The thickness of the HYH–BSA films deposited by anodic electrodeposition was varied in the range of 0–80 μm. The HYH and composite HYH–BSA films were studied by scanning electron microscopy, thermogravimetric analysis, differential thermal analysis, Fourier transform infrared spectroscopy and circular dichroism spectroscopy. The deposition mechanism and kinetics of deposition are discussed.  相似文献   

9.
A tantalum electrode is reported as an alternative electrode for electrochemical stripping analysis for the first time. Several key operational parameters that influenced the electroanalytical signals were optimized, such as pH of the electrolyte, deposition potential and deposition time. The tantalum electrode yields well-defined and sharp stripping signals for trace cadmium analysis when combined with differential pulse anodic stripping voltammetry. Under the optimized condition the electrode shows good linear behavior in the examined concentration in the range of 20–200 μg L?1 for cadmium, with a detection limit (3σ) of 0.57 μg L?1 followed a 5-min deposition step under ? 1.3 V. It also shows good reproducibility with a relative standard deviation of 2.56% for ten consecutive measurements. The sensor was also employed for real sample determination and exhibited excellent performance compared with the result of inductively coupled plasma-mass spectrometry.  相似文献   

10.
The dosimetric characteristics of γ-radiation-induced defects in magnesium lactate (ML) rods (3.5 mm×10 mm) formulated by mixing ML with molten mixtures of paraffin wax and EVA copolymer have been investigated using electron paramagnetic resonance (EPR). The EPR spectrum of irradiated ML rods was characterized by a quartet signal with the spectroscopic splitting g-factor of 2.0048±0.0003 at 0.4 mT. The useful dose range of the rod dosimeter was 100 Gy to 80 kGy. The mass attenuation coefficient, μ/ρ, and the mass energy-absorption coefficient, μen/ρ, versus energy in the range of 10 keV to 20 MeV indicate that the prepared ML dosimeter is typically adipose tissue equivalent overall this energy range. The overall combined uncertainties (at 2σ) associated with routine dose monitoring in the dose range of 0.1–10 kGy and 10–80 kGy were found to be 6.14% and 6.36%, respectively.  相似文献   

11.
Cu-deposited TiO2 films were prepared by photoreduction of Cu(II) in the presence of sodium formate. With the initial Cu(II) concentrations more than 100 mg L?1, induction periods were observed before the transmittance decreased. Scanning electron microscopy indicated that Cu particles of 2.6 ± 0.5 μm were deposited isolatedly with much open space in the induction periods. The films prepared by changing the irradiation time within the induction periods showed a higher photocatalytic activity than a pure TiO2 for the degradation of methylene blue under the reaction condition without purging air.  相似文献   

12.
The arrays of gold nanoparticles (AuNPs) were fabricated on flexible and transparent single-walled carbon nanotube (SWCNT) films using the electrochemical deposition method, and the patterned nanotubes were then used as electrodes for hydroxylamine detection. The sizes and densities of the AuNPs could easily be controlled by varying the amount of charge deposited, and the gold-deposited area showed a homogeneous distribution on the exposed SWCNT film surface. X-ray diffraction analysis of the AuNPs shows a face-centered cubic structure that is dominated by the lowest energy {111} facets. The oxidation of the hydroxylamine on the AuNP-deposited SWCNT films depended strongly on the solution pH, and the maximum catalytic current was observed at a pH of 9.0. A linear electrical response was observed for concentrations ranging from 0.016 to 0.210 mM, and the detection limit and the sensitivity were 0.72 μM and 165.90 μAmM?1 cm?2, respectively. Moreover, the amperometric response in hydroxylamine showed a stable response for a long time (300 s), during which time it retained 94% of its initial value. In the long-term storage stability test, the current response to hydroxylamine decreased slightly, with only 17% leakage after 30 days.  相似文献   

13.
The development of a mechanically stable, functionally graded Ti-doped a-C:H interface layer in combination with a functional a-C:H coating requires a reduction of the brittle phases which induce generally problems in the transitions from Ti to TiC/a-C:H. The core objective of this study was to develop an optimum interlayer between the substrate and the functional top layer for biomedical applications, namely for tooth implants. Since the interlayer may be exposed to the sliding process, in the case of local failure of the top layer it has to fulfil the same criteria: biocompatibility, high wear resistance and low friction.The functional Ti-C:H layers with thickness in the range 2.5–3.5 μm were deposited by a magnetron sputtering/PECVD hybrid process by sputtering a Ti-target in a C2H2 + Ar atmosphere in dc discharge regime. The sets of coating samples were prepared by varying the C and H concentrations controlled by the C2H2 flow during the deposition process. The tribological properties were evaluated on a pin-on-disc tribometer at room temperature (RT) and at 100 °C using 440C balls with a diameter of 6 mm. The tests at 100 °C were performed to investigate the effect of the sterilization temperature on the tribological properties and the coating lifetime as well. The tribological performance was examined with respect to the friction coefficient, the wear rates of the coating and the counter-parts and the analysis of the wear debris. The Ti/C ratio decreased almost linearly from 4.5 to 0.1 with increasing C2H2 flow; the hydrogen content showed a minimum of 5 at.% at C2H2 flow of 30 sccm, while for lower flows it was about 10 at.%. The coatings could be divided into three groups based on the C2H2 flow: (i) 10–15 sccm, exhibiting severe abrasive damage during the sliding tests, (ii) 20–45 sccm, showing the highest hardness and friction values, and (iii) 52–60 sccm, with moderate hardness and minimal values of the friction coefficient and the wear rate.  相似文献   

14.
Iron (Fe) and copper (Cu) are essential metals in physiological cell metabolism. While Fe is easy to determine biochemically in histological slices, Cu and zinc (Zn) distribution is frequently critical in confirming the presence of an overload in disturbed Fe/Cu metabolism. To analyze Fe, Cu and Zn in a near histological resolution, energy dispersive microscopic synchrotron radiation X-ray fluorescence was applied.In normal liver tissue, after fixation and imbedding in paraffin, mean Fe, Cu and Zn concentrations were 152 ± 54, 20.1 ± 4.3 and 88.919.5 μg/g sample weight, respectively. No substantial, characteristic differences in their distribution were found in the two-dimensional scans. In slices from patients with hemochromatosis mean Fe, Cu and Zn concentrations were 1102 ± 539, 35.9 ± 14.6 and 27.2 ± 6.7 μg/g sample weight, respectively. Additionally, a significant decrease in phosphorus and sulphur concentrations existed. An increased Cu around cirrhotic regenerations nodules is mostly associated with a lymphocytic infiltration in this region. Analyzing concentrations of Fe in different regions of the samples show a clear negative dependency between Fe and Cu, Cu and Zn, but a positive one between Fe and Zn.Conclusion: With a focal beam size of 15 μm in diameter a resolution of the elemental distribution was achieved which is widely comparable with stained histological slices (20× light microscope). The analysis of simultaneous determined elements reveals metabolic differences between Fe, Cu and Zn in liver tissue from patients with hemochromatosis.  相似文献   

15.
Ruthenium(0) composite hydrogenated amorphous carbon nitride (Ru/a-CNx:H) films were deposition on single crystal silicon (1 0 0) substrate by electrochemical deposition technique with acetonitrile as carbon source, and Ru3(CO)12 as dopant. In the deposited progress, the Si (1 0 0) acted as anode. The relative atomic ratio of Ru/N/C was about 0.28/0.33/1, and Ru nanocrystalline particles about 8 nm were homogeneously dispersed into the amorphous carbon matrix. After doping Ru into a-CNx:H films, the conductivity of the films were evidently improved and the resistivity drastically decrease from 108 Ω cm to about 100 Ω cm.  相似文献   

16.
The decomposition of volatile organic compounds (VOCs) using a pilot system of electron beam (EB)–catalyst coupling was investigated. Two aromatic VOCs, toluene (1800 ppmC) and o-xylene (1500 ppmC), were irradiated with a dose range of 0–10 kGy at room temperature. The removal efficiencies for toluene and o-xylene were 92.4% and 94.5%, respectively, under a 10 kGy absorbed dose condition, which were higher than the results of 45.7% and 52.3% when EB-only was used, respectively. The CO2 selectivity approached 100% for both toluene and o-xylene using the EB-catalyst coupling system, while the concentrations of O3 formed were 0.02 ppm (toluene) and 0.003 ppm (o-xylene) at 10 kGy. The aerosol concentration was also measured as 43.2 μg/m3 (toluene) and 53.4 μg/m3 (o-xylene) at 10 kGy absorbed dose.  相似文献   

17.
In this study, well-ordered and vertically-aligned nickel nanowires (NiNWs) with a controllable length were grown inside the nanopores of anodic alumina oxide templates (AAOTs) using a simple electrochemical deposition (ECD) method. The electron field emission characteristics of the prepared NiNWs within AAOTs with two pore diameters (100 and 200 nm) and length in the range of 2.7–22 μm were measured and discussed. The turn-on field/the enhancement factor of 8.5 and 7-μm-long NiNWs prepared within 100 and 200 pore diameter AAOTs, respectively, were about 3.46 V/μm/17,621 and 4.8 V/μm/5001, respectively, according to I–V measurements.  相似文献   

18.
A sensitive and selective liquid chromatographic–tandem mass spectrometric (LC–MS–MS) method was developed to determine pantoprazole sodium (PNT) in human urine. After solid-phase extraction with SPE cartridge, the urine sample was analysed on a C18 column (symmetry 3.5 μm; 75 mm × 4.6 mm i.d) interfaced with a triple quadrupole tandem mass spectrometer. Positive electrospray ionization was employed as the ionization source. The mobile phase consisted of acetonitrile–water (90:10, v/v). The method was linear over a concentration range of 1–100 ng mL?1. The lower limit of quantitation was 1 ng mL?1. The intra-day and inter-day relative standard deviation across three validation runs over the entire concentration range was <10.5%. The accuracy determined at three concentrations (8.0, 50.0 and 85.0 ng mL?1 PNT) was within ±1.25% in terms of relative errors.  相似文献   

19.
A Re coil-filament in-torch vaporization (ITV) sample introduction system was interfaced to a sector field inductively coupled plasma-mass spectrometry (SFICP-MS) system. In this first report on an un-optimized ITV-SF-ICP-MS system, detection limits were established using 5 μL volumes of 100 pg mL 1 standard solutions, translating to 0.5 pg absolute. Such absolute amounts of a dried solution are near or below the detection limit of many ICP-based techniques. The absolute detection limits for Cd, Eu, Pb, Ti, U and Zn were in the 0.2–2 fg range (or, in the 10's of millions to millions of atoms for Pb, Cd, Zn and Ti, about one million atoms for U and about 800 thousand for Eu). These absolute detection limits along with the ability of ITV to handle minute amounts of discrete samples (thus eliminating memory effects from nanoparticles adhering to the walls of pneumatic nebulization sample introduction systems and from clogging of the mass spectrometer orifice), use of sonicated water-based slurries (that eliminated contamination from acid digestion reagents or from slurry stabilization reagents), and elimination of oxygen containing molecular ion interferences due to use of dry samples enabled concentration determinations of Ti (and consequently of TiO2) in pg mL 1 concentrations of slurries of manufactured, 20 nm diameter TiO2 nanoparticles.  相似文献   

20.
Graphene oxide (GO) was applied for construction of an effective biocathode based on bilirubin oxidase (BOD). Separation of small-sized GO sheets together with the BOD immobilisation protocol has detrimental effects on the bioelectrocatalytic reduction of oxygen. When BOD was deposited on electrochemically reduced GO (ErGO) only a negligible current density j = 2.6 μA cm 2 was observed. Current density dramatically increased to a value of 46 μA cm 2 once BOD was in-situ mixed with as-received GO directly on a glassy carbon electrode (GCE) with subsequent electrochemical reduction of the BOD/GO composite. When this protocol was tested with small-sized GO flakes separated simply using centrifugation, the fabricated biocathode exhibited j = 120 μA cm 2. A current density further increased to j = 280 μA cm 2 when BOD and purified GO were incubated ex-situ for 4 h, followed by the BOD/GO composite collection by centrifugation, its deposition on the GCE and electrochemical reduction. Moreover, oxygen reduction current increased steeply with a steady-state current density achieved at high potential (≈ 500 mV), close to the onset potential of oxygen reduction (≈ 580 mV).  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号