首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A sensitive and selective high-performance liquid chromatography/atmospheric pressure chemical ionisation tandem mass spectrometry (HPLC/APCI-MS/MS) method for the simultaneous detection of 18 benzodiazepines and metabolites in human blood is described. The procedure utilises butyl chloride extraction at alkaline pH followed by reversed-phase liquid chromatography. The technique is suitable for screening analyses and confirmation of identity of the benzodiazepines at their lowest reported therapeutic concentrations using 500 microL of blood. The method has been successfully applied in forensic cases involving low concentrations of benzodiazepines.  相似文献   

2.
Benzodiazepines are among the most frequently prescribed drugs due to their sedative, hypnotic, anxiolytic, muscle relaxant and antiepileptic properties. Because of the high consumption of benzodiazepines worldwide, this class of drugs and their metabolites are frequently present in both clinical and forensic cases. For these reasons, the analysis of benzodiazepines and their metabolites in biological fluids is of great interest to clinicians and forensic toxicologists. This paper reviews procedures for multi-analyte single-stage (LC-MS) and liquid chromatography-tandem mass spectrometry (LC-MS/MS) using different mass analyzers for the screening, identification and/or quantification of drugs, poisons and/or their metabolites in blood, plasma, serum or urine published since 2001. Basic information about the biosamples assayed, work-up, LC column, mobile phase, ionization type, mass spectral detection mode, matrix effects and validation data for each procedure is summarized. The feasibility of using LC-MS(/MS) techniques to identify and quantify benzodiazepines and their metabolites is also discussed.  相似文献   

3.
Hydroxylated polycyclic aromatic hydrocarbons are metabolites of persistent organic pollutants which are formed during the bioactivation process of biological matrices and whose toxicity is being studied. The aim of this work was the development of a novel analytical method for the determination of these metabolites in human tissues, known to have bioaccumulated their parent compounds. Samples were treated by salting-out assisted liquid-liquid extraction and the extracts were analyzed by ultra-high performance liquid chromatography coupled to mass spectrometry with a hybrid quadrupole-time-of-flight analyzer. The proposed method achieved limits of detection in the 0.15–9.0 ng/g range for the five target analytes (1-hydroxynaphthalene, 1-hydroxypyrene, 2-hydroxynaphthalene, 7-hydroxybenzo[a]pyrene, and 9-hydroxyphenanthrene). The quantification was achieved by matrix-matched calibration using 2,2´-biphenol as internal standard. For all compounds, relative standard deviation, calculated for six successive analyses, was below 12.1%, demonstrating good precision for the developed method. None of the target compounds was detected in the 34 studied samples. Moreover, an untargeted approach was applied to study the presence of other metabolites in the samples, as well as their conjugated forms and related compounds. For this objective, a homemade mass spectrometry database covering 81 compounds was created and none of them was detected in the samples.  相似文献   

4.
A new ultra high performance liquid chromatography with electrospray ionization time of flight mass spectrometry method for the selective and sensitive separation, identification, and determination of selected designer benzodiazepines (namely, pyrazolam, phenazepam, etizolam, flubromazepam, diclazepam, deschloroetizolam, bentazepam, nimetazepam, and flubromazolam) in human serum was developed. The separation of the studied designer benzodiazepines was achieved on C18 chromatographic column using gradient elution within 6 min without any significant matrix interferences. Liquid–liquid extraction with butyl acetate was applied for serum samples cleanup and preconcentration of studied designer benzodiazepines. The method was validated in terms of linearity, limit of detection, limit of quantification, matrix effects, specificity, precision, accuracy, recovery, and sample stability. The limit of detection values were 0.10–0.15 ng/mL. The method was applied to a spiked serum sample to demonstrate its applicability for systematic toxicology analysis. Furthermore, a capillary chromatographic method with micellar electrokinetic chromatography was used for the estimation of partition coefficients of studied designer benzodiazepines as important parameters to evaluate their pharmacological and toxicological properties.  相似文献   

5.
We developed a simple and rapid method for the simultaneous determination of phosphorus-containing amino acid herbicides (glyphosate, glufosinate, bialaphos) and their major metabolites, aminomethylphosphonic acid (AMPA) and 3-methylphosphinicopropionic acid (MPPA), in human serum. Serum samples were filtrated through an ultrafiltration membrane to remove proteins. The filtrate was then washed with chloroform, and injected into a liquid chromatography-tandem mass spectrometry (LC-MS/MS) system. Chromatographic separation was achieved on a hydrophilic interaction chromatography (HILIC) column. Determination of the target herbicides and metabolites was successfully carried out without derivatization or solid phase extraction (SPE) cartridge clean-up. The recoveries of these compounds, added to human serum at 0.2μg/mL, ranged from 94% to 108%, and the relative standard deviations (RSDs) were within 5.9%. The limits of detection (LODs) were 0.01μg/mL for MPPA, 0.02μg/mL for AMPA, 0.03μg/mL for both glyphosate and glufosinate, and 0.07μg/mL for bialaphos, respectively.  相似文献   

6.
A new-multi residue method was developed for the environmental monitoring of 65 stimulants, opiod and morphine derivatives, benzodiazepines, antidepressants, dissociative anaesthetics, drug precursors, human urine indicators and their metabolites in wastewater and surface water. The proposed analytical methodology offers rapid analysis for a large number of compounds, with low limits of quantification and utilises only one solid-phase extraction-ultra performance liquid chromatography-positive electrospray ionisation tandem mass spectrometry (SPE-LC-MS/MS) method, thus overcoming the drawbacks of previously published procedures. The method employed solid phase extraction with the usage of Oasis MCX sorbent and subsequent ultra performance liquid chromatography-positive electrospray ionisation tandem mass spectrometry. The usage of a 1.7 μm particle size column (1 mm×150 mm) resulted in very low flow rates (0.04 mLmin(-1)), and as a consequence gave good sensitivity, low mobile phase consumption and short retention times for all compounds (from 2.9 to 23.1 min). High SPE recoveries (>60%) were obtained for the majority of compounds. The mean correlation coefficients of the calibration curves were typically higher than 0.997 and showed good linearity in the range 0-1000 μgL(-1). The method limits of detection ranged from 0.1 ngL(-1) for compounds including cocaine, benzoylecgonine, norbenzoylecgonine and 2-oxo-3-hydroxy-LSD to 100 ngL(-1) for caffeine. Method quantification limits ranged from 0.5 to 154.2 ngL(-1). Intra- and inter-day repeatabilities were on average less than 10%. The method accuracy range was within -33.1 to 30.1%. The new multi-residue method was used to analyse drugs of abuse in wastewater and river water in the UK environment. Of the targeted 65 compounds, 46 analytes were detected at levels above the method quantification limit (MQL) in wastewater treatment plant (WWTP) influent, 43 in WWTP effluent and 36 compounds in river water.  相似文献   

7.
A tandem mass spectrometric investigation of the collision-induced dissociation of five commonly prescribed psychoactive pharmaceuticals, risperidone, sertraline, paroxetine, trimipramine, and mirtazapine, and their metabolites has been carried out. Quadrupole ion trap mass spectrometry was employed to generate tandem mass spectrometric (MS/MS) data of the compounds under investigation and structural assignments of product ions were supported by quadrupole time-of-flight mass spectrometry. These fragmentation studies were then utilised in the development of a liquid chromatographic method to identify the drugs and their metabolites in human hair and saliva samples, thus providing relevant profiling information.  相似文献   

8.
A method for the analysis of thyroxine in human serum, utilising 'exact matching' isotope dilution mass spectrometry (IDMS) in combination with liquid chromatography/tandem mass spectrometry (LC/MS/MS), has been developed with a limit of quantification of 0.5 ng g(-1) of thyroxine in human serum. The extraction and clean-up of thyroxine from serum involves an efficient protein-precipitation stage followed by a solid-phase extraction procedure to produce an extract essentially free from interfering compounds. The method is reproducible, with expanded uncertainties of less than 2%, and is relatively fast to perform.  相似文献   

9.
Prostanoids are potent biologically active lipid molecules demanding for analysis methods combining precision, sensitivity and high-throughput for pharmacological and clinical applications. The present research describes the development and validation of an on-line automated method based on solid-phase extraction liquid chromatography-tandem mass spectrometry (SPE-LC-MS/MS) for the quantification of prostanoids in human serum. This approach overcomes the main limitation of previous methods involving manual protocols, such as analyte losses, metabolites degradation and time-consuming protocols, are minimized. Human serum (100 μL) was directly injected into an automatic solid-phase extraction workstation for cleanup and preconcentration of the target metabolites. The eluate was on-line transferred to a reversed-phase analytical column for chromatographic separation prior to mass spectrometry detection in selected reaction monitoring mode. The detection limits for the target analytes ranged from 2.3 to 63.3 pg on column. The precision (expressed as relative standard deviation) was within 3.30 and 6.15% for repeatability and from 4.16 to 11.11% for within-laboratory reproducibility. Accuracy was evaluated with spiked and non-spiked serum samples to estimate concentration differences that could be affected by matrix effects or inefficient SPE performance. Accuracy, estimated as recovery factor, was from 87.7 to 100% for the target compounds. The proposed method is reliable and has an excellent potential for high-throughput use in both clinical and research laboratories by minimizing analyst intervention.  相似文献   

10.
A method is proposed for the detection and confirmation of the presence of beta-blockers and their metabolites in fivefold diluted human urine samples by ultra performance liquid chromatography coupled with electrospay ionization tandem mass spectrometry. The limits of detection for most of compounds are 5–10 ng/mL. A substantial effect of ionization suppression was observed. The determination of metabolites and glucuronides of beta-blockers without additional derivatization and extraction is described for the first time.  相似文献   

11.
Girisopam possesses selective anxiolytic action without muscle relaxant and anticonvulsive activity. After a 100-mg oral dose of 14C-labelled girisopam to seven male subjects, the mean recovery of 14C radioactivity was 51% in urine and 33% in faeces. A high-performance liquid chromatographic method has been developed for studying girisopam in single-dose pharmacokinetic studies. The serum extract was chromatographed on a normal-phase column using a mobile phase of hexane-ethanol-diethyl ether (66:9:25, v/v) and ultraviolet detection at 235 nm. The recovery was 60% and the detection limit was 3 ng/ml, using 1 ml of serum. After a 20-min delay, girisopam is rapidly absorbed. After reaching a mean serum level of 178 ng/ml at a mean time of 2.0 h, the serum concentration of girisopam decreased with a mean elimination half-time of 22.2 h. The metabolites were separated by high-performance liquid chromatography, radio thin-layer chromatography and gas chromatography. Their structures were determined by liquid chromatography-mass spectrometry, mass spectrometry and gas chromatography-mass spectrometry. Their chemical structures were confirmed by comparison with synthesized reference compounds. The major urinary metabolites were 7-demethylgirisopam (I), 4'-hydroxygirisopam (II) and 4-hydroxymethyl-4-demethylgirisopam (III), which were in conjugated form, and 4-carboxy-4-demethylgirisopam (V), a compound with an open-chain structure (VII) and traces of 4-demethyl-4-oxogirisopam (VIII) and 4-hydroxymethyl-4-demethylgirisopam (III), which were in non-conjugated form. The metabolic profile in the serum consisted predominantly of the glucuronides of I, II and III. The non-conjugated metabolites were the metabolite with the open-chain structure (VII), III and V. Besides the parent compound, the faeces sample contained conjugates of I and II.  相似文献   

12.
张秀尧  蔡欣欣  张晓艺 《色谱》2010,28(1):23-33
针对公共卫生突发事件和临床毒物学检测实践中亟待解决的问题,建立了血浆和尿液中42种精神药物及其代谢产物的超高效液相色谱-串联质谱(UPLC-MS/MS)快速确证分析方法。样品经乙腈沉淀后,以乙酸铵和甲醇-乙腈(1:1, v/v)混合液作为流动相进行梯度洗脱,在Acquity UPLC BEH C18色谱柱上分离后用电喷雾串联质谱法检测,采用正、负离子快速切换多反应监测模式监测,基质标准同位素内标法定量。血浆样品中待测组分的加标回收率除了奋乃静、硫利哒嗪和氯丙嗪的分别为37.6%~57.5%, 36.3%~48.3%和52.4%~67.4%外,尿液样品中待测组分的加标回收率除了曲唑酮和地西泮的分别为100%~142%和108%~177%外,血浆和尿液中其余待测组分的加标回收率分别为60.2%~125%和64.5%~126%,相对标准偏差分别为0.8%~26%和2.6%~18%(n=6);除了巴比妥类药物的检出限为20~100 mg/L外,其余药物的检出限均为0.05~2.0 mg/L。该方法简单、快速、特异性强、灵敏度高。  相似文献   

13.
An analytical procedure for the simultaneous determination in human serum of 43 common drugs of abuse and their metabolites belonging to the different chemical and toxicological classes of amphetamines, benzodiazepines, dibenzazepines, cocaine, lysergic acid diethylamide, opioids, phencyclidine, tricyclic antidepressants, and zolpidem, using 33 deuterated standards, is presented. The sample treatment was developed to be a very simple protein precipitation and filtration. All analyses were performed with a high-performance liquid chromatography-electrospray ionization-tandem mass spectrometry in positive ionization mode. All analytes were calibrated up to 550 μg/L. The limit of detection ranged from 0.6 ng/mL (EDDP) to 13.7 ng/mL (flunitrazepam). The method has been validated according to the guidelines of the Gesellschaft für Toxikologische und Forensische Chemie, using three multiple reaction mode (MRM) transitions and retention time for positive compound identification, instead of two MRMs, in anticipation of the new guidelines for January 2011.  相似文献   

14.
The authors have developed a gas chromatographic method for the simultaneous quantification of quazepam in plasma and its two main metabolites, 2-oxoquazepam and N-desmethylquazepam. This method involves an extraction from plasma using butyl acetate, and an analysis by electron-capture detection on a CP-Sil 5 WSCOT capillary column. Intra- and inter-day precision and accuracy were better than 10% for each of these three compounds, even near their detection limit estimated at 0.2 ng/ml. Linearity proved satisfactory between 0.2 and 60-70 ng/ml. For endogenous plasma components, adequate specificity was achieved. Despite some inconveniences, a long analysis time, a progressive saturation of the column owing to a low oven temperature, and a relatively short life-span of the CP-Sil 5 columns, this method was the only one available in the literature for the quantification of quazepam and its metabolites from the same plasma sample. It was successfully applied to phase I studies in healthy volunteers.  相似文献   

15.
Among the new psychoactive substances (NPS), so-called designer benzodiazepines have become of particular importance over the last 2 years, due to their increasing availability on the internet drug market. Therapeutically used nitrobenzodiazepines such as flunitrazepam are known to be extensively metabolized via N-dealkylation to active metabolites and via nitro reduction to the 7-amino compounds. The aim of the present work was to tentatively identify phase I and II metabolites of the latest members of this class appearing on the NPS market, clonazolam, meclonazepam, and nifoxipam, in human urine samples. Nano-liquid chromatography-high-resolution mass spectrometry was used to provide data about their detectability in urine. Data revealed that clonazolam and meclonazepam were extensively metabolized and mainly excreted as their amino and acetamino metabolites. Nifoxipam was also extensively metabolized, but instead mainly excreted as the acetamino metabolite and a glucuronic acid conjugate of the parent. Based on analysis of human urine samples collected in cases of acute intoxication within the Swedish STRIDA project, and samples submitted for routine drug testing, the most abundant metabolites and good targets for urine drug testing were 7-aminoclonazolam for clonazolam, 7-acetaminomeclonazepam for meclonazepam, and 7-acetaminonifoxipam for nifoxipam.  相似文献   

16.
An isotope dilution liquid chromatography/tandem mass spectrometry is proposed as a reference method to determine the level of tyrosine in human serum. The advantages of this method include simple sample preparation without derivatization, the selective detection of compounds of interest in complex matrices, and the use of an isotopically labeled analogue as an internal standard. Tyrosine and its isotopically labeled analogue were monitored at a transfer m/z of 182.1/136.2 and 188.1/142.2, corresponding to [M+H]+/[M+H-HCOOH]+ in a multiple reaction monitoring mode. The expanded uncertainty for the measurement of tyrosine in the serum was approximately 0.95% within a 95% confidence level. For the verification of this method, a standard reference material with a certified value was analyzed. The analyzed result was in good agreement with the certified value. The isotope dilution liquid chromatography/tandem mass spectrometry result of the human serum was also compared with results obtained from clinical laboratories, and showed inconsistent results. These inconsistent results suggest that standards certified by the proposed reference method are required in order to improve measurement reliability in clinical fields.  相似文献   

17.
This paper describes a method for the determination of eight sedative hypnotics (benzodiazepines and barbiturates) in sewage sludge using pressurized liquid extraction and liquid chromatography with tandem mass spectrometry. Pressurized liquid extraction operating conditions were optimized and maximum recoveries were reached using methanol under the following operational conditions: 100ºC, 1500 psi, extraction time of 5 min, one extraction cycle, flush volume of 60% and purge time of 120 s. Pressurized liquid extraction recoveries were higher than 88% for all the compounds except for carbamazepine (55%). The repeatability and reproducibility between days, expressed as relative standard deviation (n = 5), were lower than 6 and 10%, respectively. The detection limits for all compounds were lower than 12.5 μg/kg of dry weight. The method was applied to determine benzodiazepines and barbiturates in sewage sludge from urban sewage treatment plants, and carbamazepine showed the highest concentration (7.9–18.9 μg/kg dry weight).  相似文献   

18.
以人体血清中3种脂溶性维生素检测为例,探讨了一种针对人体内源性代谢物的分析方法。采用液相色谱-串联质谱(LC-MS/MS)对人体血清中维生素A、维生素D_3和维生素E进行检测,分别通过混合人血清基质加入标准品及内标再扣除内源性物质本底的方法,以及与牛血清白蛋白(BSA)模拟基质加标的方法建立标准曲线进行定量分析。结果表明,采用混合人血清基质所建方法对维生素A、维生素D_3和维生素E的检出限分别为4.2、0.8、67.2 ng/mL,定量下限分别为13.7、2.6、221.9 ng/mL。两种方法的线性相关系数均大于0.996;对于实际样品在低、高两个加标浓度下的回收率为90.7%~112%,相对标准偏差(RSD)为1.0%~4.5%,具有良好的准确性和重现性。对40组未知样本的检测结果表明,两种方法无统计学差异。因此,对于人体内源性代谢物采用混合人血清基质扣除本底的方法,可以实现标准品与待测样品基质匹配的准确分析,有利于临床相关疾病的便捷诊断。  相似文献   

19.
Designer benzodiazepines represent an emerging class of new psychoactive substances. While other classes of new psychoactive substances such as cannabinoid receptor agonists and designer stimulants are mainly consumed for hedonistic reasons, designer benzodiazepines may also be consumed as ‘self‐medication’ by persons suffering from anxiety or other psychiatric disorders or as stand‐by ‘antidote’ by users of stimulant and hallucinogenic drugs. In the present study, five benzodiazepines (adinazolam, cloniprazepam, fonazepam, 3‐hydroxyphenazepam and nitrazolam) and one thienodiazepine (metizolam) offered as ‘research chemicals’ on the Internet were characterized and their main in vitro phase I metabolites tentatively identified after incubation with pooled human liver microsomes. For all compounds, the structural formula declared by the vendor was confirmed by nuclear magnetic resonance spectroscopy, gas chromatography–mass spectrometry (MS), liquid chromatography MS/MS and liquid chromatography quadrupole time‐of‐flight MS analysis. The detected in vitro phase I metabolites of adinazolam were N‐desmethyladinazolam and N‐didesmethyladinazolam. Metizolam showed a similar metabolism to other thienodiazepines comprising monohydroxylations and dihydroxylation. Cloniprazepam was metabolized to numerous metabolites with the main metabolic steps being N‐dealkylation, hydroxylation and reduction of the nitro function. It has to be noted that clonazepam is a metabolite of cloniprazepam, which may lead to difficulties when interpreting analytical findings. Nitrazolam and fonazepam both underwent monohydroxylation and reduction of the nitro function. In the case of 3‐OH‐phenazepam, no in vitro phase I metabolites were detected. Formation of licensed benzodiazepines (clonazepam after uptake of cloniprazepam) and the sale of metabolites of prescribed benzodiazepines (fonazepam, identical to norflunitrazepam, and 3‐hydroxyphenazepam) present the risk of incorrect interpretation of analytical findings. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

20.
Presented is the first comprehensive study of drugs of abuse on suspended particulate matter (SPM) in wastewater. Analysis of SPM is crucial to prevent the under-reporting of the levels of analyte that may be present in wastewater. Analytical methods to date analyse the aqueous part of wastewater samples only, removing SPM through the use of filtration or centrifugation. The development of an analytical method to determine 60 compounds on SPM using a combination of pressurised liquid extraction, solid phase extraction and liquid chromatography coupled with tandem mass spectrometry (PLE-SPE-LC-MS/MS) is reported. The range of compounds monitored included stimulants, opioid and morphine derivatives, benzodiazepines, antidepressants, dissociative anaesthetics, drug precursors, and their metabolites. The method was successfully validated (parameters studied: linearity and range, recovery, accuracy, reproducibility, repeatability, matrix effects, and limits of detection and quantification). The developed methodology was applied to SPM samples collected at three wastewater treatment plants in the UK. The average proportion of analyte on SPM as opposed to in the aqueous phase was <5% for several compounds including cocaine, benzoylecgonine, MDMA, and ketamine; whereas the proportion was >10% with regard to methadone, EDDP, EMDP, BZP, fentanyl, nortramadol, norpropoxyphene, sildenafil and all antidepressants (dosulepin, amitriptyline, nortriptyline, fluoxetine and norfluoxetine). Consequently, the lack of SPM analysis in wastewater sampling protocol could lead to the under-reporting of the measured concentration of some compounds.  相似文献   