首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 343 毫秒
1.
A liquid chromatography–tandem mass spectrometry method for the simultaneous quantification of buprenorphine (BUP), norbuprenorphine (NBUP), buprenorphine glucuronide (BUP-Gluc), and norbuprenorphine glucuronide (NBUP-Gluc) in human urine was developed and fully validated. Extensive endogenous and exogenous interferences were evaluated and limits of quantification were identified empirically. Analytical ranges were 5–1,000 ng/mL for BUP and BUP-Gluc and 25–1,000 ng/mL for NBUP and NBUP-Gluc. Intra-assay and interassay imprecision were less than 17% and recovery was 93–116%. Analytes were stable at room temperature, at 4 °C, and for three freeze–thaw cycles. This accurate and precise assay has sufficient sensitivity and specificity for urine analysis of specimens collected from individuals treated with BUP for opioid dependence.  相似文献   

2.
A liquid chromatographic/electrospray ionization tandem mass spectrometric method for the quantification of the synthetic opiate buprenorphine (BUP), norbuprenorphine (NBUP), buprenorphine-3-beta-D-glucuronide (BUP-3-G) and norbuprenorphine-3-beta-D-glucuronide (NBUP-3-G) in human plasma was developed and validated. Identification and quantification were based on the following transitions: m/z 468 to 396 and 414 for BUP, m/z 414 to 326 and 340 for NBUP, m/z 644 to 468 for BUP-3-G and m/z 590 to 414 for NBUP-3-G. Calibration by linear regression analysis utilized deuteratated internal standards and a weighting factor of 1/x. The method was accurate and precise across a linear dynamic range of 0.6-50.0 ng ml(-1). Pretreatment of plasma samples using solid-phase extraction was sufficient to limit matrix suppression to <30% for all four analytes. The method proved to be suitable for the quantification of BUP and the related metabolites in plasma samples collected from BUP-maintained study participants.  相似文献   

3.
A liquid chromatography tandem mass spectrometry method for buprenorphine (BUP), norbuprenorphine (NBUP), methadone, 2-ethylidene-1,5-dimethyl-3,3-diphenylpyrrolidine (EDDP), cocaine, benzoylecgonine, ecgonine methyl ester (EME), morphine, codeine, 6-acetylmorphine, heroin, 6-acetylcodeine, cotinine, and trans-3′-hydroxycotinine quantification in sweat was developed and comprehensively validated. Sweat patches were mixed with 6 mL acetate buffer at pH 4.5, and supernatant extracted with Strata-XC-cartridges. Reverse-phase separation was achieved with a gradient mobile phase of 0.1% formic acid and acetonitrile in 15 min. Quantification was achieved by multiple reaction monitoring of two transitions per compound. The assay was a linear 1–1,000 ng/patch, except EME 5–1,000 ng/patch. Intra-, inter-day and total imprecision were <10.1%CV, analytical recovery 87.2–107.7%, extraction efficiency 35.3–160.9%, and process efficiency 25.5–91.7%. Ion suppression was detected for EME (−63.3%) and EDDP (−60.4%), and enhancement for NBUP (42.6%). Deuterated internal standards compensated for these effects. No carryover was detected, and all analytes were stable for 24 h at 22 °C, 72 h at 4 °C, and after three freeze/thaw cycles. The method was applied to weekly sweat patches from an opioid-dependent BUP-maintained pregnant woman; 75.0% of sweat patches were positive for BUP, 93.8% for cocaine, 37.5% for opiates, 6.3% for methadone and all for tobacco biomarkers. This method permits a fast and simultaneous quantification of 14 drugs and metabolites in sweat patches, with good selectivity and sensitivity.  相似文献   

4.
Opioid use during pregnancy can result in the newborn being physically dependent on the substance, thus experiencing drug withdrawal, termed neonatal abstinence syndrome (NAS). Buprenorphine and methadone are two drugs used to treat opioid withdrawal and are approved for use in pregnancy. Quantification of these compounds in umbilical cord plasma would help assess in utero exposure of neonates in cases of buprenorphine or methadone use during pregnancy. An LC‐MS/MS method using solid‐phase extraction sample preparation was developed and validated for the simultaneous quantification of methadone, buprenorphine, norbuprenorphine, and glucuronide metabolites in umbilical cord plasma. The average accuracy (percentage error) and precision (relative standard deviation) were <15% for each validated concentration. Our data establishes a 2 week maximum freezer storage window in order to achieve the most accurate cord plasma concentrations of these analytes. Additionally, we found that the umbilical cord tissue analysis was less sensitive compared with analysis with umbilical cord blood plasma, indicating that this may be a more appropriate matrix for determination of buprenorphine and metabolite concentrations. This method was successfully applied to the analysis of cord blood from women with known buprenorphine or methadone use during pregnancy. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

5.
A novel sensitive and selective liquid chromatography-tandem mass spectrometry (LC-MS-MS) method simultaneously determined buprenorphine (BUP) and its active metabolite, norbuprenorphine (NBUP), and a coformulant, naloxone was developed, validated and applied successfully in humans. Buprenorphine-d 4 and norbuprenorphine-d 3 were used as the internal standard. The analysis was performed on a silica column, and the mobile phase was isocratic and composed of acetonitrile:2 mM ammonium formate in H2O (82:18, v/v). Mass spectrometry employed multiple reaction monitoring modes with transitions of m/z 468.1?C55.2 for BUP, 414.2?C101.2 for NBUP, 328.3?C310.3 for naloxone, 472.1?C59.2 for buprenorphine-d 4 and 417.2?C101.2 for norbuprenorphine-d 3. Lower limit of quantification (LLOQ) of the analytical method was 0.05 ng mL?1 for BUP, 0.1 ng mL?1 for NBUP and 0.025 ng mL?1 for naloxone, respectively. The standard calibration curves of BUP, NBUP and naloxone were linear over the concentration range of 0.05?C20 ng mL?1, 0.1?C20 ng mL?1 and 0.025?C20 ng mL?1, respectively. The precisions (RSD) and accuracies (RE) of LLOQ and other QC samples were in acceptable range, with RSD < 20% and RE ± 20% for LLOQ and RSD < 15% and RE within ±15% for QC samples. The method was accurate, precise and specific, and was applied to the pharmacokinetic study of buprenorphine in healthy volunteers.  相似文献   

6.
A rapid and sensitive LC–MS/MS method was developed and validated for the simultaneous determination of buprenorphine and its three metabolites (buprenorphine glucuronide, norbuprenorphine and norbuprenorphine glucuronide) as well as naloxone and its metabolite naloxone glucuronide in the rat plasma. A hydrophilic interaction chromatography column and a mobile phase containing acetonitrile and ammonium formate buffer (pH 3.5) were used for the chromatographic separation. Mass spectrometric detection was achieved by an electrospray ionization source in the positive mode coupled to a triple quadrupole mass analyzer. The calibration curves for the six analytes displayed good linearity over the concentration range 1.0 or 5.0–1000 ng/mL. The intra and inter‐day precision (CV) ranged from 2.68 to 16.4% and from 9.02 to 14.5%, respectively. The intra‐ and inter‐day accuracy (bias) ranged from −14.2 to 15.2% and from −9.00 to 4.80%, respectively. The extraction recoveries for all the analytes ranged from 55 to 86.9%. The LC–MS/MS method was successfully applied to a pharmacokinetic study of buprenorphine–naloxone combination in rats.  相似文献   

7.
A liquid chromatography/electrospray ionization tandem mass spectrometry (LC/ESI-MS/MS) method has been developed for the analysis of buprenorphine (BUP) and nor-buprenorphine (NBUP) in biological fluids. Analytes are isolated from urine and blood, after addition of d4-buprenorphine (d4-BUP) as internal standard, by solid-phase extraction. Preparation of hair involves external decontamination, mechanical pulverization, overnight incubation in acidic medium, and neutralization prior to extraction. Enzymatic hydrolysis with beta-glucuronidase may be performed to distinguish between free and total BUP. Chromatographic separation is accomplished by gradient elution on a cyanopropyl 2.1 x 150 mm column. Positive ion ESI and MS analyses are carried out in an ion trap mass spectrometer. The use of this mass analyzer allows effective collisional experiments to be performed on ESI-generated MH+ species. Abundant product ions are produced, which can be monitored together with precursor ions without losing sensitivity. Thus, assay selectivity is definitely increased with respect to LC/ESI-MS/MS methods in which only precursor ions are monitored. The method has good linearity (calibration curves were linear in the range 0.1-10 ng/mL in urine and blood, in the range 10-160 pg/mg in hair) and limits of detection of 0.05 ng/mL for both BUP and NBUP in blood and urine samples, of 4 pg/mg for both analytes in hair. Both intra- and inter-assay precision and accuracy were satisfactory at three concentrations studied: relative standard deviations were <13.7% in urine, <17.3% in blood, <17.8% in hair; percent deviation of the mean from the true value was always <10.5% in urine and blood, <16.1% in hair. The method can be used to determine both analytes in the urine and hair of drug addicts on replacement therapy, and in post-mortem blood specimens when there is suspicion of drug-related death.  相似文献   

8.
A method for simultaneous determination of buprenorphine (BUP), norbuprenorphine (NBUP), methadone, 2-ethylidene-1,5-dimethyl-3,3-diphenylpyrrolidine (EDDP), cocaine, benzoylecgonine (BE), ecgonine methyl ester (EME), anhydroecgonine methyl ester (AEME), morphine, codeine, 6-acetylmorphine (6AM), heroin, 6-acetylcodeine (6AC), nicotine, cotinine, and trans-3′-hydroxycotinine (OH-cotinine) by liquid chromatography tandem mass spectrometry in oral fluid (OF) was developed and extensively validated. Acetonitrile (800 μL) and OF (250 μL) were added to a 96-well Isolute-PPT+protein precipitation plate. Reverse-phase separation was achieved in 16 min and quantification was performed by multiple reaction monitoring. The assay was linear from 0.5 or 1 to 500 μg/L. Intraday, interday, and total imprecision were less than 13% (n?=?20), analytical recovery was 92–114% (n?=?20), extraction efficiencies were more than 77% (n?=?5), and process efficiencies were more than 45% (n?=?5). Although ion suppression was detected for EME, cocaine, morphine, 6AC, and heroin (less than 56%) and enhancement was detected for BE and nicotine (less than 316%), deuterated internal standards compensated for these effects. The method was sensitive (limit of detection 0.2–0.8 μg/L) and specific (no interferences) except that 3-hydroxy-4-methoxyamphetamine interfered with AEME. No carryover was detected, and all analytes were stable for 24 h at 22 °C, for 72 h at 4 °C, and after three freeze–thaw cycles, except cocaine, 6AC, and heroin (22–97% loss). The method was applied to 41 OF specimens collected throughout pregnancy with a Salivette® OF collection device from an opioid-dependent BUP-maintained pregnant woman. BUP ranged from 0 to 7,400 μg/L, NBUP from 0 to 71 μg/L, methadone from 0 to 3 μg/L, nicotine from 32 to 5,020 μg/L, cotinine from 125 to 508 μg/L, OH-cotinine from 11 to 51 μg/L, cocaine from 0 to 419 μg/L, BE from 0 to 351 μg/L, EME from 0 to 286 μg/L, AEME from 0 to 7 μg/L, morphine from 0 to 22 μg/L, codeine from 0 to 1 μg/L, 6AM from 0 to 4 μg/L, and heroin from 0 to 2 μg/L. All specimens tested negative for EDDP and 6AC. This method permits a fast and simultaneous quantification of 16 drugs and metabolites in OF, with good selectivity and sensitivity.  相似文献   

9.
A 63Ni electron-capture gas chromatographic assay is described for buprenorphine, a potent narcotic agonist--antagonist. In addition, the assay is useful for the measurement of the metabolite norbuprenorphine and demethoxybuprenorphine, a rearrangement product resulting when buprenorphine is exposed to acid and heat. An extraction procedure was developed which optimized recovery of buprenorphine from biological samples and produced minimal background interferences and emulsion problems. Extract residues were derivatized with pentafluoropropionic anhydride and assayed by gas chromatography. Samples were analyzed with and without enzyme hydrolysis, thus providing a selective and sensitive assay for both free and conjugated buprenorphine, norbuprenorphine and demethoxybuprenorphine. The lower limits of detection following extraction of a 1-ml sample were ca. 10 ng/ml for buprenorphine and demethoxybuprenorphine and 5 ng/ml for norbuprenorphine. Application of the assay to human samples following a 40-mg oral dose of buprenorphine produced no evidence for the presence of demethoxybuprenorphine in urine or feces. Norbuprenorphine (free and conjugated) was present in urinary and fecal samples; buprenorphine (free and conjugated) was found in high amounts only in feces and in trace amounts in urine as conjugated buprenorphine. The urinary and fecal excretion pattern observed for a human subject following oral dosing of buprenorphine suggests enterohepatic circulation of buprenorphine.  相似文献   

10.
A rapid, simple and inexpensive spectrofluorimetric method has been developed for the simultaneous identification and quantification of anthracene (ANT), 9,10-dimethylanthracene (DIM), 2-aminoanthracene (AMI) and dibenz[ah]anthracene (DIB). A well-resolved spectrum for the mixture of these four compounds is obtained based on a single non-linear variable-angle synchronous scanning. The linear concentration ranges are 10–1000, 5–500, 50–1000 and 10–200 ng mL–1 for ANT, DIM, AMI and DIB, respectively, at λexem = 358/380, 399/408, 414/465 and 298/394 nm, respectively. The analyses are performed in cyclohexane. Recoveries of 90.0–111.0% in synthetic mixtures are obtained. The detection limits are 2.0 ng mL–1 for DIM, 2.7 ng mL–1 for ANT, 15.8 ng mL–1 for AMI and 4.2 ng mL–1 for DIB. The method has also been applied to several real water samples with satisfactory results. Received: 29 March 2000 / Revised: 30 June 2000 / Accepted: 4 July 2000  相似文献   

11.
A selected-ion monitoring method was developed for determination of buprenorphine and its N-dealkylated metabolite (norbuprenorphine) in human plasma and urine. N-Propylnorbuprenorphine was added as internal standard to 2-3 ml of sample and the alkaloids were extracted with toluene-2 butanol at pH 9.4. After back-extraction in dilute sulphuric acid, the compounds were heated at 110 degrees C. This procedure led to quantitative loss of methanol followed by ring formation between the 6-methoxy group and the branched side-chain of all compounds. The derivatives were extracted into dichloromethane-2-butanol and treated with pentafluoropropionic anhydride. The resulting derivatives were suitable for selected-ion monitoring analysis. The coefficient of variation was found to be 4.5% at 5 ng/ml and 8.9% at 50 ng/ml in urine. The corresponding values for plasma were 6.2% and 5.3%, respectively. The lower limit of detection in plasma was 150 pg/ml, permitting analysis of plasma levels of buprenorphine for 24 h and urine levels of buprenorphine and norbuprenorphine for more than seven days after a therapeutic dose of buprenorphine. This method is the first with sufficient specificity and sensitivity for characterization of the clinical pharmacokinetics of buprenorphine.  相似文献   

12.
The sublingual combination of buprenorphine and naloxone (Suboxone®) and Methadone Maintenance Therapy have been found effective in treating heroin addiction. A new analytical method suitable for the simultaneous determination of buprenorphine, norbuprenorphine, methadone and naloxone in human plasma by means of liquid chromatography with coulometric detection has been developed. The chromatographic separation was achieved with a phosphate buffer–acetonitrile mixture as the mobile phase on a cyano column. The monitoring cell of the coulometric detector was set at an oxidation potential of +0.600 V. A rapid clean-up procedure of the biological samples using a microextraction by packed sorbent technique has been implemented, employing a C8 sorbent inserted into a syringe needle. The extraction yield values were satisfactory for all analytes (>85%). The calibration curves were linear over a range of 0.25–20.0 ng mL−1 for buprenorphine and norbuprenorphine, 3.0–1000.0 ng mL−1 for methadone and 0.13–10.0 ng mL−1 for naloxone. The sensitivity was also high with limits of detection of 0.08 ng mL−1 for both buprenorphine and norbuprenorphine, 0.9 ng mL−1 for methadone and 0.04 ng mL−1 for naloxone. The intraday and interday precision data were always satisfactory.The method was successfully applied to plasma samples obtained from former heroin addicts treated with opioid replacement therapy.  相似文献   

13.
A novel simple, sensitive, selective, and rapid high-performance liquid chromatography coupled with tandem mass spectrometry method was developed and validated for quantification of riluzole in human plasma. The chromatography was performed by using a Zorbax-SB-C18 (4.6 × 75 mm, 3.5 μm) column , isocratic mobile phase 0.1% formic acid/acetonitrile (10:90 v/v), and an isotope-labeled internal standard (IS), [13C,15N2]riluzole. The extraction of drug and internal standard was performed by liquid–liquid extraction and analyzed by MS in the multiple reaction monitoring (MRM) mode using the respective [M+H]+ ions, m/z 235.0/165.9 for riluzole and m/z 238.1/169.0 for the IS. The calibration curve was linear over the concentration range 0.5–500.0 ng/ml for riluzole in human plasma. The limit of quantification (LOQ) was demonstrated at 0.5 ng/ml. The within-batch and between-batch precision were 0.6–2.3% and 1.4–5.7%, and accuracy was 97.1–101.1% and 98.8–101.2% for riluzole respectively. Drug and IS were eluted within 3.0 min. The validated method was successfully applied in a bioequivalence study of riluzole in human plasma.  相似文献   

14.
A rapid, sensitive, and simple HPLC–MS–MS method, with electro-spray ionization and cetirizine as internal standard (IS), has been developed and validated for simultaneous quantification of fexofenadine and pseudoephedrine in human plasma. The analytes were isolated from plasma by solid-phase extraction (SPE) on Oasis HLB cartridges. The compounds were chromatographed on an RP 18 column with a mixture of ammonium acetate (10 mm, pH 6.4) and methanol as mobile phase. Quantification of the analytes was based on multiple reaction monitoring (MRM) of precursor-to-product ion pairs m/z 502 → 466 for fexofenadine, m/z 166 → 148 for pseudoephedrine, and m/z 389 → 201 for cetirizine. The linear calibration range for both analytes was 2–1,700 ng mL−1 (r = 0.995), based on analysis of 0.1 mL plasma. Extraction recovery was 91.5 and 80.88% for fexofenadine and pseudoephedrine, respectively. The method was suitable for analysis of human plasma samples obtained 72 h after administration of a drug containing both fexofenadine and pseudoephedrine.  相似文献   

15.
The amount of volatile dimethylselenide (DMSe) in breath has been monitored after ingestion of sub-toxic amounts of selenium (300 μg 77Se, as selenite) by a healthy male volunteer. The breath samples were collected in Tedlar bags every hour in the first 12 h and then at longer intervals for the next 10 days. The samples were subjected to speciation analysis for volatile selenium compounds by use of cryotrapping–cryofocussing–GC–ICP–MS. Simultaneously, all urine was collected and subjected to total selenium determination by use of ICP–MS. By monitoring m/z 82 and 77, background or dietary selenium and selenium from the administered selenite were simultaneously determined in the urine and in the breath—dietary selenium only was measured by monitoring m/z 82 whereas the amount of spiked 77Se (99.1% [enriched spike]) and naturally occurring selenium (7.6% [natural abundance]) were measured by monitoring m/z 77. Quantification of DMSe was performed by using DMSe gas samples prepared in Tedlar bags (linear range 10–300 pg, R 2=0.996, detection limit of Se as DMSe was 10 pg Se, or 0.02 ng L−1, when 0.5 L gas was collected). Dimethylselenide was the only selenium species detected in breath samples before and after the ingestion of 77Se-enriched selenite. Additional DM77Se was identified as early as 15 min after ingestion of the isotopically-labelled selenite. Although the maximum concentration of 77Se in DMSe was recorded 90 min after ingestion, the natural isotope ratio for selenium in DMSe (77/82) was not reached after 20 days. The concentration of DMSe correlated with the total Se concentration in the urine during the experiment (R 2=0.80). Furthermore, the sub-toxic dose of 300 μg selenium led to a significant increase of DMSe and renal excretion of background selenium, confirming that selenium ingested as selenite is homeostatically controlled by excretion. The maximum concentration of DMSe resulting from the spiked selenite was 1.4 ng Se L−1 whereas the dietary background level was less than 0.4 ng Se L−1. Overall excretion as DMSe was calculated to be 11.2% from the ingested selenite within the first 10 days whereas urinary excretion accounts for nearly 18.5%.  相似文献   

16.
Evodiamine and rutecarpine are two kinds of indole alkaloids contained in the fruit of Evodiae fructus, which have been shown to exhibit various bioactivities in humans. A liquid chromatography–tandem mass spectrometric method (LC–MS/MS) was developed for the determination of evodiamine and rutecarpine in human serum. The serum was extracted by solid-phase extraction (SPE) and analyzed using a C18 column and a mobile phase consisting of methanol–water (85:15) solution containing 5 mmol/L ammonium formate at a flow rate of 0.5 mL/min. The mass spectrometer was operated in positive mode, employing the extracted ion chromatogram (EIC) for detection and quantitation of evodiamine (m/z 288) and rutecarpine (m/z 304). Good linear relationships between the peak area and the concentration were obtained in the ranges of 5.2–1040 ng/mL and 10.2–1020 ng/mL, with correlation coefficients (r) of 0.999 and 0.998, for evodiamine and rutecarpine, respectively. The repeatabilities (RSD, n=6) of quantitation for evodiamine and rutecarpine were 2.18–4.00% and 2.99–5.67%, respectively, and the recovery ranged from 90.5% to 98.1%. A comparative study of the different ionization and quantitation modes, including ESI–MS, ESI–MS/MS, APCI–MS and APCI–MS/MS, was also accomplished. The MS/MS fragmentation mechanism of the base peak ([M+H]+, m/z 304) of evodiamine was investigated in order to identify the analytes in more complicated body fluid samples.   相似文献   

17.
To evaluate the pharmacokinetics of a novel analogue of ginkgolide B, 10-O-dimethylaminoethylginkgolide B (XQ-1) in rat plasma in pre-clinical studies, a sensitive and specific liquid chromatographic method with electrospray ionization mass spectrometry detection (LC–ESI–MS) was developed and validated. After a simple extraction with ethyl acetate, XQ-1 was analyzed on a Shim-pack C18 column with a mobile phase of a mixture of 1 μmol L−1 ammonium acetate containing 0.02% formic acid and methanol (55:45, v/v) at a flowrate of 0.3 mL min−1. Detection was performed in selected ion monitoring (SIM) mode using target ions at [M + H]+ m/z 496.05 for XQ-1 and m/z 432.10 for the internal standard (lafutidine). Linearity was established for the concentration range from 2 to 1,000 ng mL−1 . The extraction recoveries ranged from 86.0 to 89.9% in plasma at concentrations of 5, 50, and 500 ng mL−1. The lower limit of quantification was 2 ng mL−1 with 100 μL plasma. The validated method was successfully applied to a pharmacokinetic study after intragastic administration of XQ-1 mesylate in rats at a dose of 20 mg kg−1.  相似文献   

18.
This study presents a high-performance liquid chromatography–electrospray ionization–mass spectrometric (LC–ESI–MS) method for the simultaneous determination of tramadol and acetaminophen in human plasma using phenacetinum as the internal standard. After alkalization with saturated sodium bicarbonate, both compounds were extracted from human plasma with ethyl acetate and were separated by HPLC on a Hanbon LiChrospher CN column with a mobile phase of 10 mM ammonium acetate buffer containing 0.5% formic acid–methanol (40:60, v/v) at a flow rate of 1 mL min−1. Analytes were determined using electrospray ionization in a single quadrupole mass spectrometer. LC–ESI–MS was performed in the positive selected-ion monitoring (SIM) mode using target ions at [M+H]+ m/z 264.3 for tramadol, [M+H]+ m/z 152.2 for acetaminophen and [M+H]+ m/z 180.2 for phenacetinum. Calibration curves were linear over the range of 5–600 ng mL−1 for tramadol and 0.03–16 μg mL−1 for acetaminophen. The inter-run relative standard deviations were less than 14.4% for tramadol and 12.3% for acetaminophen. The intra-run relative standard deviations were less than 9.3% for tramadol and 7.9% for acetaminophen. The mean plasma extraction recovery for tramadol and acetaminophen were in the ranges of 82.7–85.9 and 83.6–85.3%. The method was applied to study the pharmacokinetics of a new formulation of tramadol/acetaminophen tablet in healthy Chinese volunteers.  相似文献   

19.
Liu AC  Lin TY  Su LW  Fuh MR 《Talanta》2008,75(1):198-204
An online solid-phase extraction (SPE) liquid chromatography-electrospray tandem mass spectrometry (LC-ESI-MS/MS) method for the determination of buprenorphine (Bup), norbuprenorphine (nBup), buprenorphie-3-beta-d-glucuronide (Bup-3-G) and norbuprenorphie-3-beta-d-glucuronide (nBup-3-G) in human urine was developed and validated. A mixed mode SPE column with both hydrophilic and lipophilic functions was used for online extraction. A C18 column was employed for LC separation and ESI-MS/MS was utilized for detection. Buprenorphine-D(4) (Bup-D4) and norbuprenophine-D3 (nBup-D3) were used as internal standards for quantitative determination. The extraction, clean-up and analysis procedures were controlled by a fully automated six-port switch valve. Identification and quantification were based on the following transitions: m/z 468-->414 for Bup, m/z 414-->364 for nBup, m/z 644-->468 for Bup-3-G and m/z 590-->414 for nBup-3-G, respectively. Good recoveries from 93.6% to 102.2% were measured and satisfactory linear ranges for these analytical compounds were determined. Minimal ion suppression effect (approximately 7% response decrease) was determined. Intra-day and inter-day precision showed coefficients of variance, CV, ranged from 3.3% to 10.1% and 4.4% to 9.8%, respectively. Accuracy ranging from 97.0% to 104.0% was determined. The applicability of this newly developed method was demonstrated by analyzing human urine samples from the patients in Bup treatment program for therapeutic monitoring purpose.  相似文献   

20.
A new sensitive and fast quantitative analytical method for the simultaneous determination of clopidogrel, its main metabolite clopidogrel carboxylic acid, and the newly described acyl glucuronide metabolite, in human plasma samples, is presented. The analytical procedures (plasma storage, handling, and extract storage in the autosampler) were optimized in order to avoid back-conversion; a known drawback in measurements of clopidogrel. Clopidogrel acyl glucuronide was confirmed as a major source of back-conversion to the parent drug in the presence of methanol, and thorough stability experiments were carried out to find the most appropriate conditions for an accurate analysis of clopidogrel and the two metabolites. The method was validated by assessing selectivity, sensitivity, linearity, accuracy, and precision for all three analytes, in accordance to Food and Drug Administration guidelines. Spiked quality controls in plasma as well as incurred samples were used to verify back-conversion in the selected conditions, with results meeting European Medicines Agency acceptance criteria (concentrations within 80–120% of the first reading). The method was then applied to a pharmacokinetic study, and for the first time, a pharmacokinetic curve of clopidogrel acyl glucuronide in human plasma is presented. The concentrations ranged up to 1,048.684 ng/mL, with a mean of 470.268 ng/mL, while clopidogrel had a mean C max of 1.348 ng/mL; these orders of magnitude show how much the back-conversion of this metabolite may influence clopidogrel quantification if it is not properly controlled.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号