首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
A highly sensitive and accurate method based on the precolumn derivatization of bile acids (BA) with a high ionization efficiency labeling reagent 1,2-benzo-3,4-dihydrocarbazole-9-ethyl-benzenesulfonate (BDEBS) coupled with LC/MS has been developed. After derivatization, BA molecules introduced a weak basic nitrogen atom into the molecular core structure that was readily ionized in commonly used acidic HPLC mobile phases. Derivatives were sufficiently stable to be efficiently analyzed by atmospheric pressure chemical ionization (APCI)-MS/MS in positive-ion mode. The MS/MS spectra of BA derivatives showed an intense protonated molecular ion at m/z [M + H]+. The collision-induced dissociation of the molecular ion produced fragment ions at [MH-H2O]+, [MH-2H2O]+, [MH-3H2O]+. The characteristic fragment ions were at m/z 320.8, 262.8, and 243.7 corresponding to a cleavage of N-CO, O-CO, and C-OCO, respectively, and bonds of derivatized molecules. The selected reaction monitoring, based on the m/z [M+H]+ --> [MH-H2O]+, [MH-2H2O]+, [MH-3H2O]+, 320.8, 262.8, and 243.7 transitions, was highly specific for the BA derivatives. The LODs for APCI in a positive-ion mode, at an S/N of 5, were 44.36-153.6 fmol. The validation results showed high accuracy in the range of 93-107% and the mean interday precision for all standards was <15% at broad linear dynamic ranges (0.0244-25 nmol/mL). Good linear responses were observed with coefficients of > 0.9935 in APCI/MS detection. Therefore, the facile BDEBS derivatization coupled with mass spectrometric analysis allowed the development of a highly sensitive and specific method for the quantitation of trace levels of the free and glycine-conjugated BA from human serum samples.  相似文献   

2.
Anatoxin-a (AN) and homoanatoxin-a (HMAN) are potent neurotoxins produced by a number of cyanobacterial species. A new, sensitive liquid chromatography/multiple tandem mass spectrometry (LC/MS(n)) method has been developed for the determination of these neurotoxins. The LC system was coupled, via an electrospray ionisation (ESI) source, to an ion-trap mass spectrometer in positive ion mode. The [M+H](+) ions at m/z 166 (anatoxin-a) and m/z 180 (homoanatoxin-a) were used as the precursor ions for multiple MS experiments. MS(2)bond;MS(4) spectra displayed major fragment ions at m/z 149 (AN), 163 (HMAN), assigned to [Mbond;NH(3)+H](+); m/z 131 (AN), 145 (HMAN), assigned to [Mbond;NH(3)bond;H(2)O+H](+), and m/z 91 [C(7)H(7)](+). Although the chromatographic separation of these neurotoxins is problematic, reversed-phase LC, using a C(18) Luna column, proved successful. Calibration data for anatoxin-a using spiked water samples (10 mL) in LC/MS(n) modes were: LC/MS (25-1000 microg/L), r(2) = 0.998; LC/MS(2) (5-1000(microg/L), r(2) = 0.9993; LC/MS(3) (2.5-1000 microg/L), r(2) = 0.9997. Reproducibility data (% RSD, N = 3) for each LC/MS(n) mode ranged between 2.0 at 500 microg/L and 7.0 at 10 microg/L. The detection limit (S/N = 3) for AN was better than 0.03 ng (on-column) for LC/MS(3) which corresponded to 0.6 microg/L.  相似文献   

3.
The utility of liquid chromatography combined with time-of-flight mass spectrometry (LC/TOFMS) was demonstrated for studies on chiral unsaturated epoxy compounds, sex pheromones produced mainly by female moths in the family Geometridae. By electrospray ionization (ESI), each synthetic epoxyalkadiene derived from (Z,Z,Z)-3,6,9-triene with a C(18)-C(23) straight chain showed three ion series, [M + NH(4)](+), [M + H](+) and [M - OH](+), with high resolution and good sensitivity, indicating its molecular formula. In addition to these, characteristic fragment ions at m/z M - 57 and M - 71 for the 3,4-epoxides and at m/z M - 123 and 123 for the 9,10-epoxides were detected, whereas the 6,7-epoxides did not produce fragment ions that reflected their structures. Monitoring these diagnostic ions during the LC/MS analysis of a gland extract, the natural sex pheromone of the mulberry looper was confirmed to be (Z,Z)-cis-9,10-epoxy-3,6-octadecadiene, which was separable from the other positional isomers on an ODS column. Furthermore, (Z,Z)-cis-3,4-epoxy-6,9-nonadecadiene secreted by the Japanese giant looper was analyzed with a chiral column, and the stereochemistry was determined directly.  相似文献   

4.
Niu L  Xie Z  Cai T  Wu P  Xue P  Chen X  Wu Z  Ito Y  Li F  Yang F 《Journal of separation science》2011,34(9):987-994
High‐speed counter‐current chromatography (HSCCC) was successfully applied for the preparative separation and purification of alkaloids from Corydalis bungeana Turcz. (Kudiding in Chinese) for the first time. After the measurement of partition coefficient of seven target alkaloids in the nine two‐phase solvent systems composed of CHCl3–MeOH–(0.1 M; 0.2 M; 0.3 M) HCl (4:1.5:2; 4:2:2; 4:3:2, v/v), CHCl3–MeOH–0.2 M HCl (4:2:2, v/v) and CHCl3–MeOH–0.3 M HCl (4:3:2, v/v) were finally selected for the HSCCC separation using the first upper phase as the stationary phase and the stepwise elution of the two lower mobile phases. Consequently, sanguinarine (10 mg), corynoline (25 mg), protopine (20 mg), corynoloxine (18 mg), and 12‐hydroxycorynoline (8 mg) were obtained from 200 mg of crude alkaloid extracts with purities of 94–99% as determined by HPLC. Their chemical structures were characterized on the basis of 1H‐NMR, 13C‐NMR, and LC‐ESI‐Q‐TOF‐MS/MS analyses.  相似文献   

5.
Ceramides are important intracellular second messengers that play a role in the regulation of cell growth, differentiation and programmed cell death. Analysis of these second messengers requires sensitive and specific analytical method to detect individual ceramide species and to differentiate between them. Eight molecular species of ceramide were identified from the marine sponge Haliclona cribricutis using electrospray ionization tandem mass spectrometry (ESI-MS/MS). From this marine sponge N-hencicosanoyl (N21:0) to N-hexasanoyl (N26:0) Octadecasphing-4 (E)-enine have been reported for the first time. The ESI-MS spectra gave several strong protonated molecular ion [M+H](+) with the corresponding bis (2-ethyl hexyl) phthalate adduct [M+H+DHEP](+). The collision induced dissociation (CID) on ceramides at m/z 622.7337, 636.7645, 650.7789, 664.7925 and 678.8130 conducted at low-collision energy produced well characteristic product ions at m/z 252.31, 264.32, 278.33, 282.33 and 296 .35 for d18:1 sphingosine regardless of the length of the fatty chain. The MS/MS of the Phthalate adduct [M+H+DHEP](+) at m/z 1013.1820, 1027.1971, 1041.2176, 1055.2394 and 1069.2573 also yielded characterizing product ions for sphingosine and confirmed the molecular ion at m/z 391 for bis (2-ethyl hexyl) phthalate. The major ions in the [M+H](+) and [M+H+DHEP](+) were due to neutral loss of [M+H-H(2)O](+) and [M+H(H(2)O)(2)](+).  相似文献   

6.
Di-n-butyl sulfate (DNBS) has been studied by electrospray (ESI) and chemical (CI) ionization mass spectrometry. The use of methanol as solvent in electrospray ionization allows observation of relatively abundant [DNBS + CH(3)OH + H](+) ions (m/z 243) which upon collision dissociate to [DNBS + H](+) ions (m/z 211). In both ESI and CI experiments, it is found that [DNBS + H](+) ions lead to m/z 113 daughter ions. The composition of this m/z 113 fragment ion and its mechanism of formation have been established by high resolution measurements and CID-MIKE experiments. An 'internal substitution' reaction involving an ion-neutral intermediate is proposed to explain the formation of a [C(8)H(17)](+) ion (m/z 113) by loss of a H(2)SO(4) molecule. Finally, a LC/ESI-MS/MS quantification method is proposed in which a detection limit of di-n-butyl sulfate in the ppm range is obtained. It is suggested that the quantification method might be extended to higher dialkyl sulfates. Copyright 2000 John Wiley & Sons, Ltd.  相似文献   

7.
A sensitive, rapid and specific method for the simultaneous quantification of oxysophocarpine (OSC) and its active metabolite sophocarpine (SC) in rat plasma was developed and validated, using a liquid-liquid extraction procedure followed by liquid chromatography/electrospray ionization mass spectrometric (LC/ESI-MS) analysis. The separation was performed on a Zorbax Extend-C(18) column (2.1 mm i.d. x 50 mm, 5 microm) with a C(18) guard column using methanol-water containing 5 mm ammonium acetate (15:85, v/v) as mobile phase. Analysis was performed in selected ion monitoring (SIM) mode with an electrospray ionization (ESI) interface. [M + H](+) at m/z 263 for OSC, [M + H](+) at m/z 247 for SC and [M + H](+) at m/z 249 for matrine (internal standard) were selected as detecting ions, respectively. The method was linear in the concentration ranges 10-1000 ng/mL for OSC and 5-500 ng/mL for SC. The intra- and inter-day precisions (coefficient of variation) were within 7% for both analytes. Their accuracy (relative error) ranged from -6.4 to 1.5%. The limits of detection for OSC and SC were 3 and 1.5 ng/mL, respectively. The limits of quantitation for OSC and SC were 10 and 5 ng/mL, respectively. Recoveries of both analytes were greater than 85% at the low, medium and high concentrations. Both analytes were stable during all sample storage, preparation and analytic procedures. The method was successfully applied to a pharmacokinetic study after an oral administration of OSC to rats with a dose of 15 mg/kg.  相似文献   

8.
An isotopic modification of Sanger's method for identifying peptide N-termini has been developed to assist peptide sequencing by tandem mass spectrometry. Tryptic peptides, such as Val-His-Leu-Thr-Pro-Val-Glu-Lys, are derivatized with an equimolar mixture of 2,4-dinitrofluorobenzene and [2H3]2,4-dinitrofluorobenzene. Under optimized derivatization conditions, the alpha-amino group could be derivatized while the epsilon-amine of the lysine side chain and the imidazole of histidine remained underivatized. The alpha-dinitrophenyl modified peptides were characterized by electrospray ionization-tandem mass spectrometry (ESI-MS/MS) and liquid chromatography (LC)-ESI-MS. The [M + H]+ ions showed a doublet pattern with a delta m/z of 3 and the [M + 2H]2+ ions were recognized as doublets with a delta m/z of 1.5. MS/MS was employed where both isotopic [M + 2H]2+ ions were alternately subjected to collision-induced dissociation in the second quadrupole. Fragmentation in the ionization source generated identical product ion patterns that were observed during fragmentation in the second quadrupole. In the product ion mass spectra, the N-terminal a and b ions (no c ion observed) are doublets with a delta m/z of 3 or 1.5, while the C-terminal y and z ions (no x ion observed) are singlets appearing at identical masses. Thus, the product ions containing the N-terminus derivatized with a dinitrophenyl group are unequivocally distinguished from the product ions containing the C-terminus. The dinitrophenyl modification generally enhanced the production of a and b ions without diminishing y and z ion yields.  相似文献   

9.
A simple and robust method for quantification of zolpidem in human plasma has been established using liquid chromatography-electrospray ionization tandem mass spectrometry (LC-ESI MS/MS). Es-citalopram was used as an internal standard. Zolpidem and internal standard in plasma sample were extracted using solid-phase extraction cartridges (Oasis HLB, 1 cm3/30 mg). The samples were injected into a C8 reversed-phase column and the mobile phase used was acetonitrile-ammonium acetate (pH 4.6; 10 mm) (80:20, v/v) at a flow rate of 0.7 mL/min. Using MS/MS in the selected reaction-monitoring (SRM) mode, zolpidem and Es-citalopram were detected without any interference from human plasma matrix. Zolpidem produced a protonated precursor ion ([M+H]+) at m/z 308.1 and a corresponding product ion at m/z 235.1. The internal standard produced a protonated precursor ion ([M+H]+) at m/z 325.1 and a corresponding product ion at m/z 262.1. Detection of zolpidem in human plasma by the LC-ESI MS/MS method was accurate and precise with a quantification limit of 2.5 ng/mL. The proposed method was validated in the linear range 2.5-300 ng/mL. Reproducibility, recovery and stability of the method were evaluated. The method has been successfully applied to bioequivalence studies of zolpidem.  相似文献   

10.
Liquid chromatography/tandem mass spectrometry (LC/MS/MS) based on selected reaction monitoring (SRM) is the standard methodology in quantitative analysis of administered xenobiotics in biological samples. Utilizing two SRM channels during positive electrospray ionization (ESI) LC/MS/MS method development for a drug compound containing two basic functional groups, we found that the response ratio (SRM1/SRM2) obtained using an acidic mobile phase was dramatically different from that obtained using a basic mobile phase. This observation is different from the well-established phenomenon of mobile phase affecting the [M+H](+) response, which is directly related to the amount of the [M+H](+) ions produced during the ionization. Results from follow-up work reported herein revealed that the MS/MS fragmentation patterns of four drug or drug-like compounds are affected not only by the pH, but also by the aqueous-organic ratio of the mobile phase and the buffer concentration at a given apparent pH. The observed phenomenon can be explained by invoking that a mixture of [M+H](+) ions of the same m/z value for the analyte is produced that is composed of two or more species which differ only in the site of the proton attachment, which in turn affects their MS/MS fragmentation pattern. The ratio of the different protonated species changes depending on the pH, aqueous-organic ratio, or ionic strength of the mobile phase used. The awareness of the mobile phase dependency of the MS/MS fragmentation pattern of precursor ions of identical m/z value will influence LC/MS/MS-based bioanalytical method development strategies. Specifically, we are recommending that multiple SRM transitions be monitored during mobile phase screening, with the MS/MS parameters used for each SRM optimized for the composition of the mobile phase (pH, organic percentage, and ionic strength) in which the analyte elutes.  相似文献   

11.
When zotepine, an antipsychotic drug, was electrochemically oxidized using electrospray ionization mass spectrometry (ESI-MS) coupled with a microflow electrolytic cell, [M + 16 + H]+ (m/z 348), [M-H]+ (m/z 330) and [M-14 + H]+ (m/z 318) were observed as electrochemical oxidation product ions (M represents the zotepine molecule). Although a major fragment ion that was derived from the dimethyl aminoethyl moiety was observed only at m/z 72 in the collision-induced dissociation (CID) spectrum of zotepine, new fragments such as m/z 315 and 286 ions could be generated in the CID spectrum by combining electrochemical oxidation and CID. Since these fragments were relatively specific with high ion strength, it was thought that they would be useful for developing a sensitive LC-MS/MS assay. The S-oxide and N-demethylated products were detected by electrolysis assuring that a portion of P450 metabolites of zotepine could be mimicked by the electrochemistry/electrospray ionization mass spectrometry (EC/ESI-MS) system.  相似文献   

12.
The relationships between the ionization profile, sensitivity, and structures of 64 exogenous anabolic steroids (groups I–IV) was investigated under electrospray ionization (ESI) conditions. The target analytes were ionized as [M + H]+ or [M + H–nH2O]+ in the positive mode, and these ions were used as precursor ions for selected reaction monitoring analysis. The collision energy and Q3 ions were optimized based on the sensitivity and selectivity. The limits of detection (LODs) were 0.05–20 ng/mL for the 64 steroids. The LODs for 38 compounds, 14 compounds and 12 compounds were in the range of 0.05–1, 2–5 and 10–20 ng/mL, respectively. Steroids including the conjugated keto‐functional group at C3 showed good proton affinity and stability, and generated the [M + H]+ ion as the most abundant precursor ion. In addition, the LODs of steroids using the [M + H]+ ion as the precursor ion were mostly distributed at low concentrations. In contrast, steroids containing conjugated/unconjugated hydroxyl functional groups at C3 generated [M + H ? H2O]+ or [M + H ? 2H2O]+ ions, and these steroids showed relatively high LODs owing to poor stability and multiple ion formation. An LC‐MS/MS method based on the present ionization profile was developed and validated for the determination of 78 steroids (groups I–V) in human urine. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

13.
In this study, we benefit from the combination of liquid chromatography (LC)/time-of-flight (TOF) MS accurate mass measurements to generate elemental compositions of ions and LC/ion trap multiple MS (MSn) providing complementary structural information, which is useful for the elucidation of unknown organic compounds at trace levels in complex food extracts. We have applied this approach to investigate different citrus fruits extracts, and we have identified two post-harvest fungicides (imazalil and prochloraz), the main degradation product of imazalil ([M + H]+, m/z 257) and a non-previously reported prochloraz degradation product ([M + H]+, m/z 282). The database-mediated identification of the parent compounds was based on the generated elemental composition obtained from accurate mass measurements and additional qualitative information from the high resolution chlorine isotopic clusters of both the protonated molecules (imazalil, [M + H]+ 297.0556, <0.1 ppm error, 2-Cl; prochloraz, [M + H]+ 376.0381, 1.9 ppm error, 3-Cl) and their characteristic fragments ions (imazalil: m/z 255 and 159; prochloraz: m/z 308 and 266). The correlation between the structural information provided by ion trap MS/MS fragmentation pathways of the parent species and the TOF accurate mass elemental composition data of the degradation products were the key to elucidate the structures of the degradation products of both post-harvest fungicides. Finally, where standards were not available (prochloraz), further confirmation was obtained by synthesizing the proposed degradation product by acid hydrolysis of the parent standard and confirmation by LC/TOF-MS.  相似文献   

14.
Glycoalkaloids are naturally occurring nitrogen-containing compounds present in many species of the family Solanaceae, including cultivated and wild potatoes (Solanum spp.), tomatoes (Lycopersicon spp.), etc. These compounds have pharmacological and toxicological effects on humans due to their significant anticholinesterase activity and disruption of cell membranes. Herein is reported the development of a capillary electrophoresis (CE) method using nonaqueous (NA) separation solutions in combination with ion trap mass spectrometry (MS and MS/MS) detection for the identification and quantification of glycoalkaloids and their relative aglycones. A mixture 90:10 v/v of MeCN-MeOH containing 50 mM ammonium acetate and 1.2 M acetic acid (applied voltage of 25.5 kV) was selected as a good compromise for the separation and detection of these compounds. The electrospray MS measurements were carried out in the positive ionization mode using a coaxial sheath liquid, methanol-water (1:1) with 1% of acetic acid at a flow rate of 2.5 microL/min. Under optimized experimental conditions, the predominant ion was the protonated molecular ion ([M+H](+)) of solanidine (m/z = 398), tomatidine (m/z = 416), chaconine (m/z = 852), solanine (m/z = 868), and tomatine (m/z = 1034). MS/MS experiments were carried out systematically by changing the relative collisional energy and monitoring the intensities of the fragment ions that were not high enough to allow better quantification than with the mother ions. The method was used for analyzing glycoalkaloids in potato extracts.  相似文献   

15.
The analysis of 1-hexadecyl-2-acetyl-glycerophosphocholine (platelet activating factor, PAF) by negative ion and normal-phase liquid chromatography/tandem mass spectrometry (LC/MS/MS) was investigated as an alternative technique to the currently used gas chromatography/MS and positive ion LC/MS/MS procedures. The positive ion [M + H]+ derived from PAF and generated by electrospray ionization is abundant, but the potential presence of isobaric 1-octadecanoyl-2-lyso-glycerophosphocholine (stearoyl-lyso-GPC) and 1-hexadecanoyl-2-formyl-glycerophosphocholine (PFPC) in biological samples limits the use of the most abundant collision-induced decomposition (CID) transition (formation of the phosphocholine ion, m/z 524-->184) if chromatographic separation is not achieved. Less abundant CID product ions, such as loss of the neutral ketene molecule derived from the respective fatty acyl groups, provide the requisite specificity, but the intensity of these transitions yields a signal-to-noise ratio that greatly diminishes the analytical sensitivity. With negative ion LC/MS/MS, however, the molecular anions [M - 15]- derived from PAF, stearoyl-lyso-GPC and PFPC decompose to the carboxylate anions at m/z 59, 283 and 255, respectively, permitting discrimination of these isobaric molecules even without chromatographic separation. In addition, the CID of [M - 15]- was favorable, yielding ion currents of sufficient intensity to permit the measurement of PAF when isolated from small quantities of biological material. With the use of a stable isotopically labeled variant of PAF and isotope dilution, negative ion LC/MS/MS was found to measure PAF reliably even in the presence of the isobaric stearoyl-lyso-GPC and permitted the use of non-chlorinated mobile phases for normal-phase high-performance LC.  相似文献   

16.
The dietary sources of CoQ10 and the evaluation of CoQ10 in dairy products were characterized. For quantitation of CoQ10 in food samples, 2 liquid chromatography (LC) methods with UV and mass spectrometry (MS) detections were developed. LC with UV detection was performed at 25 degrees C on a Hyperclone ODS 5 microm 150 x 4.6 mm column with mobile phase consisting of methanol-ethanol-2-propanol (70 + 15 + 15, v/v/v). Flow rate was 1.0 mL/min. Retention time of CoQ10 was 10.9 +/- 0.1 min. The method was sensitive [limit of detection (LOD) = 0.2 mg/kg], reproducible [relative standard deviation (RSD) = 3:0%), and linear up to 25 mg/kg (R > 0.999). LC/MS analysis was performed on a LUNA C18 3 microm, 150 x 4.6 mm column, using mobile phase consisting of ethanol-dioxane-acetic acid (9 + 1 + 0.01, v/v/v), flow rate was 0.6 mL/min, and the retention time of CoQ10 was 4.1 +/- 0.1 min. Identification and quantitation were performed with a Finnigan-LCQ mass detector in positive atmospheric pressure chemical ionization mode. Mass spectra were obtained in selected-ion monitoring mode; molecular mass (M+H)+ m/z 863.4 +/- 1 was used for quantitative determination. MS detection is more sensitive than UV detection (LOD = 0.1 mg/kg), less reproducible (RSD = 4.0%), and linear in selected range. Analytical recoveries are 75-90% and depend on the ratio between the amount of fat in the matrix and the concentration of CoQ10 in the sample. Some soybean milk products were analyzed together with different cow, goat, and sheep milk products. Concentrations obtained with LC and LC/MS were compared with a few accessible results available from the literature. Concentrations varied from 0 ppm in soybean milk to nearly 2 ppm in fresh milk from local farms.  相似文献   

17.
The effects of liquid chromatography mobile phase buffer contents on the ionization and fragmentation of drug molecules in liquid chromatographic/ionspray tandem mass spectrometric (LC/MS/MS) determination were evaluated for simvastatin (SV) and its hydroxy acid (SVA). The objective was to improve further the sensitivity for SV by overcoming the unfavorable condition caused by the formation of multiple major adduct ions and multiple major fragment ions when using ammonium as LC mobile phase buffer. Mobile phases (70:30 acetonitrile-buffer, 2 mM, pH 4.5) with buffers made from ammonium, hydrazine or alkyl (methyl, ethyl, dimethyl or trimethyl)-substituted ammonium acetate were evaluated. Q1 scan and product ion scan spectra were obtained for SV in each of the mobile phases under optimized conditions. The results showed that, with the alkylammonium buffers, the alkylammonium-adducted SV was observed as the only major molecular ion, while the formation of other adduct ions ([M + H](+), [M + Na](+) and [M + K](+)) was successfully suppressed. On the other hand, product ion spectra with a single major fragment ion were not observed for any of the alkylammonium-adducted SVs. The affinity of the alkylammoniums to SV and the basicity of the alkylamines are believed to be factors influencing the formation and abundance of molecular and fragment ions, respectively. Methylammonium acetate provided the most favorable condition among all the buffers evaluated and improved the sensitivity several-fold for SV in LC/MS/MS quantitation compared with that obtained using ammonium acetate buffer. Better precision for SV in both Q1 and SRM scans was observed when using methylammonium buffer compared with those using ammonium buffer. The mobile phase buffer contents did not seem to affect the ionization, fragmentation and chromatography of SVA. The results of this evaluation can be applied to similar situations with other organic molecules in ionspray LC/MS/MS determination.  相似文献   

18.
The ionization and fragmentation behaviors of carbohydrate derivatives prepared by reaction with 2-aminobenzamide (AB), 1-phenyl-3-methyl-5-pyrazolone (PMP), and phenylhydrazine (PHN) were compared under identical mass spectrometric conditions. It has been shown that the intensities of signals in MS spectra depend on the kind of saccharides investigated and reducing end labels used. PMP sialyllactose, when ionized by ESI/MALDI, produced a mixture of [M + H]+, [M + Na]+, [M - H + 2Na]+ ions in the positive mode and [M - H]-, [M + Na - 2H]- ions in the negative mode. The AB and PHN derivatives formed abundant [M + H]+ and [M - H]- ions in ESI, and by matrix-assisted laser desorption/ionization (MALDI) produced abundant [M + Na]+ ions. PMP- and reduced AB-sialyllactose produced only Y-type fragment ions under both MS/MS sources. In the electrospray ionization (ESI)-MS/MS spectrum of PHN-sialyllactose, abundant ions corresponded to B, Z cleavages and in its MALDI-MS/MS spectrum, the abundant ions were consistent with Y glycosidic cleavages with the concurrence of B, C, and cross-ring fragment ions. In the MALDI-MS spectra of oligosaccharides acquired immediately after derivatization, it was possible to detect only PHN derivatives. After purification, spectra of all three types of derivatives showed high signal-to-noise ratios with the most abundant ions observed for AB reduced saccharides. [M + Na]+ ions were the dominant products and their fragmentation patterns were influenced by the type of the labeling and the kind of oligosaccharide considered. In the MALDI-PSD and -MS/MS spectra of AB-derivatized glycans, higher m/z fragment ions corresponded to B and Y cleavages and the loss of bisecting GlcNAc appeared as a weak signal or was not detected at all. Fragmentation patterns observed in the spectra of hybrid/complex PHN and PMP glycans were more comparable-higher m/z fragments corresponded to B and C glycosidic cleavages. For PHN glycans, the abundance of ions resulting from the loss of bisecting GlcNAc depended on the number of residues linked to the 6-positioned mannose. Also, PHN and PMP derivatives produced cross-ring cleavages with abundances higher than observed in the spectra of AB derivatized oligosaccharides. For high-mannose glycans, the most informative cleavages were provided by AB and PHN type of labeling. Here, PMP produced dominant Y-cleavages from the chitobiose while other ions produced weak signals.  相似文献   

19.
The bioactive compound syringin along with edgeworoside C were separated from the n-butanol extract of the stems and barks of Edgeworthia chrysantha Lindl (E. papyrifera) by high-speed counter-current chromatography (HSCCC) while it was difficult to purify each compound by silica gel column chromatography. Syringin was isolated from this plant for the first time. The two-phase solvent system used was composed of ethyl acetate-ethanol-water at an optimized volume ratio of 15:1:15 (v/v/v). Preparative HSCCC yielded, from 110mg of the partially purified extract, 28mg of syringin and 45 mg edgeworoside C each at over 96% purity by high-performance liquid chromatography analysis. Their structures were identified by electron impact ionization MS, 1H NMR and 13C NMR.  相似文献   

20.
A highly sensitive quantification method of aldosterone by liquid chromatography-electrospray ionization tandem mass spectrometry (LC-ESI-MS/MS) was investigated in a positive mode using recently developed picolinyl derivatization. Aldosterone was smoothly and quantitatively converted to the ethyl ether-picolinyl derivative by treatment with HCl-ethanol followed by the esterification with picolinic acid in the presence of 2-methyl-6-nitrobenzoic anhydride and 4-dimethylaminopyridine. The positive ion-ESI mass spectrum of the ethyl ether-picolinyl derivative was characterized by an appearance of protonated molecule ([M+H](+)) as a base peak. The ethyl ether-picolinyl derivatization gave a successful result in a separation of aldosterone from corticosterone, dehydrocorticosterone and cortexolone, and also provided an approximately 10-fold higher ESI response in the positive-LC-ESI-MS/MS (selected reaction monitoring; SRM) when compared to that of underivatized molecule (negative mode). The limit of quantification of aldosterone by SRM using ethyl ether-picolinyl derivatization (m/z 494-->m/z 448) was 1 pg/0.2 ml serum with accuracy and precision of 92.6% and 5.6%, respectively.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号