 共查询到20条相似文献,搜索用时 17 毫秒
1.
2.
3.
The use of isotope ratio infrared spectroscopy (IRIS) for the stable hydrogen and oxygen isotope analysis of water is increasing. While IRIS has many advantages over traditional isotope ratio mass spectrometry (IRMS), it may also be prone to errors that do not impact upon IRMS analyses. Of particular concern is the potential for contaminants in the water sample to interfere with the spectroscopy, thus leading to erroneous stable isotope data. Water extracted from plant and soil samples may often contain organic contaminants. The extent to which contaminants may interfere with IRIS and thus impact upon data quality is presently unknown. We tested the performance of IRIS relative to IRMS for water extracted from 11 plant species and one organic soil horizon. IRIS deviated considerably from IRMS for over half of the samples tested, with deviations as large as 46‰ (δ2H) and 15.4‰ (δ18O) being measured. This effect was reduced somewhat by using activated charcoal to remove organics from the water; however, deviations as large as 35‰ (δ2H) and 11.8‰ (δ18O) were still measured for these cleaned samples. Interestingly, the use of activated charcoal to clean water samples had less effect than previously thought for IRMS analyses. Our data show that extreme caution is required when using IRIS to analyse water samples that may contain organic contaminants. We suggest that the development of new cleaning techniques for removing organic contaminants together with instrument‐based software to flag potentially problematic samples are necessary to ensure accurate plant and soil water analyses using IRIS. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

4.
As an alternative to isotope ratio mass spectrometry (IRMS), the isotope ratio infrared spectroscopy (IRIS) approach has the advantage of low cost, continuous measurement and the capacity for field‐based application for the analysis of the stable isotopes of water. Recent studies have indicated that there are potential issues of organic contamination of the spectral signal in the IRIS method, resulting in incorrect results for leaf samples. To gain a more thorough understanding of the effects of sample type (e.g., leaf, root, stem and soil), sample species, sampling time and climatic condition (dry vs. wet) on water isotope estimates using IRIS, we collected soil samples and plant components from a number of major species at a fine temporal resolution (every 2 h for 24–48 h) across three locations with different climatic conditions in the Heihe River Basin, China. The hydrogen and oxygen isotopic compositions of the extracted water from these samples were measured using both an IRMS and an IRIS instrument. The results show that the mean discrepancies between the IRMS and IRIS approaches for δ18O and δD, respectively, were: –5.6‰ and ?75.7‰ for leaf water; –4.0‰ and ?23.3‰ for stem water; –3.4‰ and ?28.2‰ for root water; ?0.5‰ and –6.7‰ for xylem water; –0.06‰ and ?0.3‰ for xylem flow; and ?0.1‰ and 0.3‰ for soil water. The order of the discrepancy was: leaf > stem ≈ root > xylem > xylem flow ≈ soil. In general, species of the same functional types (e.g., woody vs. herbaceous) within similar habitats showed similar deviations. For different functional types, the differences were large. Sampling at nighttime did not remove the observed deviations. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

5.
The stable isotopes of water (hydrogen and oxygen isotopes) are of utmost interest in ecology and the geosciences. In many cases water has to be extracted directly from a matrix such as soil or plant tissue before isotopes can be analyzed by mass spectrometry. Currently, the most widely used technique for water is cryogenic vacuum extraction. We present a simple and inexpensive modification of this method and document tests conducted with soils of various grain size and tree core replicates taken on four occasions during 2010. The accuracies for sandy soils are between 0.4‰ and 3‰ over a range of 21‰ and 165‰ for δ18O and δ2H, respectively. Spiking tests with water of known isotope composition were conducted with soil and tree core samples; they indicate reliable precision after an extraction time of 15 min for sandy soils. For clayey soils and tree cores, the deviations were up to 0.63‰ and 4.7‰ for δ18O and δ2H, respectively. This indicates either that the extraction time should be extended or that mechanisms different from Rayleigh fractionation play a role. The modified protocol allows a fast and reliable extraction of large numbers of water samples from soil and plant material in preparation for stable isotope analyses. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

6.
Previous studies have demonstrated the potential for large errors to occur when analyzing waters containing organic contaminants using isotope ratio infrared spectroscopy (IRIS). In an attempt to address this problem, IRIS manufacturers now provide post-processing spectral analysis software capable of identifying samples with the types of spectral interference that compromises their stable isotope analysis. Here we report two independent tests of this post-processing spectral analysis software on two IRIS systems, OA-ICOS (Los Gatos Research Inc.) and WS-CRDS (Picarro Inc.). Following a similar methodology to a previous study, we cryogenically extracted plant leaf water and soil water and measured the δ(2)H and δ(18)O values of identical samples by isotope ratio mass spectrometry (IRMS) and IRIS. As an additional test, we analyzed plant stem waters and tap waters by IRMS and IRIS in an independent laboratory. For all tests we assumed that the IRMS value represented the "true" value against which we could compare the stable isotope results from the IRIS methods. Samples showing significant deviations from the IRMS value (>2σ) were considered to be contaminated and representative of spectral interference in the IRIS measurement. Over the two studies, 83% of plant species were considered contaminated on OA-ICOS and 58% on WS-CRDS. Post-analysis, spectra were analyzed using the manufacturer's spectral analysis software, in order to see if the software correctly identified contaminated samples. In our tests the software performed well, identifying all the samples with major errors. However, some false negatives indicate that user evaluation and testing of the software are necessary. Repeat sampling of plants showed considerable variation in the discrepancies between IRIS and IRMS. As such, we recommend that spectral analysis of IRIS data must be incorporated into standard post-processing routines. Furthermore, we suggest that the results from spectral analysis be included when reporting stable isotope data from IRIS.  相似文献   

7.
8.
Isotope dilution is a useful technique to measure the labile metal pool, which is the amount of metal in soil in rapid equilibrium (<7 days) with the soil solution. This is normally performed by equilibrating soil with a metal isotope, and sampling the labile metal pool by using an extraction (E value), or by growing plants (L value). For Cu, this procedure is problematic for E values, and impossible for L values, due to the short half-life of the 64Cu radioisotope (12.4 h), which makes access and handling very difficult. We therefore developed a technique using enriched 65Cu stable isotope and measurement of 63Cu/65Cu ratios by quadrupole inductively coupled plasma mass spectrometry (ICP-MS) to measure labile pools of Cu in soils using E value techniques. Mass spectral interferences in detection of 63Cu/65Cu ratios in soil extracts were found to be minimal. Isotope ratios determined by quadrupole ICP-MS compared well to those determined by high-resolution (magnetic sector) ICP-MS. E values determined using the stable isotope technique compared well to those determined using the radioisotope for both uncontaminated and Cu-contaminated soils.  相似文献   

9.
10.
A new technique for stable lead (Pb) isotope extraction from seawater is established using Toyopearl AF-Chelate 650 M® resin (Tosoh Bioscience LLC). This new method is advantageous because it is semi-automated and relatively fast; in addition it introduces a relatively low blank by minimizing the volume of chemicals used in the extraction. Subsequent analyses by HR ICP-MS have a good relative external precision (2σ) of 3.5‰ for 206Pb/207Pb, while analyses by MC-ICP-MS have a better relative external precision of 0.6‰. However, Pb sample concentrations limit MC-ICP-MS analyses to 206Pb, 207Pb, and 208Pb. The method was validated by processing the common Pb isotope reference material NIST SRM-981 and several GEOTRACES intercalibration samples, followed by analyses by HR ICP-MS, all of which showed good agreement with previously reported values.  相似文献   

11.
Journal of Radioanalytical and Nuclear Chemistry - The influence of extraction process on Cs isotope ratios was investigated by thermal ionization mass spectrometry (TIMS) for nitric-acid (HNO3)...  相似文献   

12.
A universal method for pyrolysis and elemental analysis, suitable for the online determination of deuterium, carbon, nitrogen and oxygen isotopes for organic and inorganic substances, is presented. The samples are pyrolytically decomposed in a high-temperature pyrolysis (HTP) system, at a temperature exceeding 1400 degrees C, in the presence of reactive carbon. The method is suitable for the analysis of stable isotope ratios from hydrogen, carbon, nitrogen and oxygen. The instrumentation and experimental procedure are simple and cost-effective. The reproducibility of the delta values for D/H is better than 3 per thousand, and for (18)O, (13)C (organic) and (15)N (inorganic) it is approximately 0.2 per thousand. The HTP system is suitable for solid and liquid samples and can use an autosampler for the samples. Results are presented for the isotopic composition of international reference materials and selected laboratory reference materials, which demonstrate the precision and accuracy of the method. Possible problems in the measurement of nitrates and their solutions are particularly discussed. The analyses of oxygen isotopes in selected geological samples (carbonates, silicate, biotite) are demonstrated.  相似文献   

13.
14.
Application of microwave assisted extraction for the decomposition and dissolution of plant samples for trace metal determination by ICP-AES was examined. Dried onion, leaves of spinach beet and three reference materials CTA-OTL-1, CTA-VTL-2 and CL-1 were analyzed. Water, EDTA and hydrochloric acid (0.01, 0.10 and 1.0 M, respectively) were used as leaching solutions. The extraction efficiency was investigated by comparison of the results with those obtained after microwave wet digestion. HCl was found to be very suitable for quantitative extraction of B, Ba, Cd, Cu, Mn, Ni, Pb, Sr and Zn from the samples. For reference materials, the measured concentrations are well consistent with the certified values. The use of EDTA led to a complete extraction of B, Cd, Ni, Pb, Sr and Zn. Water was found to be a good leaching solution for boron. For extraction with HCl and EDTA, the RSD values for the concentrations measured were below 8% for most of the elements.  相似文献   

15.
Application of microwave assisted extraction for the decomposition and dissolution of plant samples for trace metal determination by ICP-AES was examined. Dried onion, leaves of spinach beet and three reference materials CTA-OTL-1, CTA-VTL-2 and CL-1 were analyzed. Water, EDTA and hydrochloric acid (0.01, 0.10 and 1.0 M, respectively) were used as leaching solutions. The extraction efficiency was investigated by comparison of the results with those obtained after microwave wet digestion. HCl was found to be very suitable for quantitative extraction of B, Ba, Cd, Cu, Mn, Ni, Pb, Sr and Zn from the samples. For reference materials, the measured concentrations are well consistent with the certified values. The use of EDTA led to a complete extraction of B, Cd, Ni, Pb, Sr and Zn. Water was found to be a good leaching solution for boron. For extraction with HCl and EDTA, the RSD values for the concentrations measured were below 8% for most of the elements. Received: 4 May 2000 / Revised: 20 June 2000 / Accepted: 22 June 2000  相似文献   

16.
The propagation of uncertainties associated with the stable oxygen isotope reference materials through a multi-point normalisation procedure was evaluated in this study using Monte Carlo (MC) simulation. We quantified the normalisation error for a particular selection of reference materials and their number of replicates, when the choice of standards is restricted to either nitrates, sulphates or organic reference materials alone, and in comparison with when this restriction was relaxed. A lower uncertainty in stable oxygen isotope analyses of solid materials performed using High-Temperature Pyrolysis (HTP) can be readily achieved through an optimal selection of reference materials. Among the currently available certified reference materials the best performing pairs minimising the normalisation errors are USGS35 and USGS34 for nitrates; IAEA-SO-6 and IAEA-SO-5 for sulphates; and IAEA-601 and IAEA-602 for organic materials. The normalisation error can be reduced further--by approximately half--if each of these two analysed reference materials is replicated four times. The overall optimal selection among all nine considered reference materials is the IAEA-602 and IAEA-SO-6 pair. If each of these two reference materials is replicated four times the maximum predicted normalisation error will equal 0.22‰, the minimum normalisation error 0.12‰, and the mean normalisation error 0.15‰ over the natural range of δ(18)O variability. We argue that the proposed approach provides useful insights into reference material selection and in assessing the propagation of analytical error through normalisation procedures in stable oxygen isotope studies.  相似文献   

17.
The measurement of the carbon isotope composition of starch and cellulose still relies on chemical isolation of these water-insoluble plant constituents and subsequent elemental analysis by isotope ratio mass spectrometry (EA/IRMS) of the purified fractions, while delta(13)C values of low-molecular-weight organic compounds are now routinely measured by gas chromatography/combustion/isotope ratio mass spectrometry (GC/C/IRMS). Here we report a simple and reliable method for processing milligram quantities of dried plant material for the analysis of the carbon isotope composition of lipids, soluble sugars, starch and cellulose from the same sample. We evaluated three different starch preparation methods, namely (1) enzymatic hydrolysis by alpha-amylase, (2) solubilization by dimethyl sulfoxide (DMSO) followed by precipitation with ethanol, and (3) partial hydrolysis by HCl followed by precipitation of the resulting dextrins by ethanol. Starch recovery for three commercially available native starches (from potato, rice and wheat) varied from 48 to 81% for the techniques based on precipitation, whereas the enzymatic technique exhibited yields between 99 and 105%. In addition, the DMSO and HCl techniques introduced a significant (13)C fractionation of up to 1.9 per thousand, while the carbon isotope composition of native starches analyzed after enzymatic digestion did not show any significant difference from that of untreated samples. The enzymatic starch preparation method was then incorporated into a protocol for determination of delta(13)C signatures of lipids, soluble carbohydrates, starch and crude cellulose. The procedure is based on methanol/chloroform/water extraction of dried and ground leaf material. After recovery of the chloroform phase (lipid fraction), the methanol/water phase was deionized by ion exchange (soluble carbohydrate fraction) and the pellet treated with heat-stable alpha-amylase (starch fraction). The remaining insoluble material was subjected to solvolysis by diglyme (cellulose fraction). The method was shown to be applicable to foliar tissues of a variety of different plant species (spruce, erect brome, maize and soybean).  相似文献   

18.
Stable oxygen isotope compositions (δ18O values) of two commercial and one synthesized silver orthophosphate reagents have been determined on the VSMOW scale. The analyses were carried out in three different laboratories: lab (1) applying off‐line oxygen extraction in the form of CO2 which was analyzed on a dual inlet and triple collector isotope ratio mass spectrometer, while labs (2) and (3) employed an isotope ratio mass spectrometer coupled to a high‐temperature conversion/elemental analyzer (TC/EA) where Ag3PO4 samples were analyzed as CO in continuous flow mode. The δ18O values for the proposed new comparison materials were linked to the generally accepted δ18O values for Vennemann's TU‐1 and TU‐2 standards as well as for Ag3PO4 extracted from NBS120c. The weighted average δ18OVSMOW values for the new comparison materials UMCS‐1, UMCS‐2 and AGPO‐SCRI were determined to be + 32.60 (± 0.12), + 19.40 (± 0.12) and + 14.58 (± 0.13)‰, respectively. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

19.
Micromilling is a conventional technique used in the analysis of the isotopic composition of geological materials, which improves the spatial resolution of sample collection for analysis. However, a problem still remains concerning the recovery ratio of the milled sample. We constructed a simple apparatus consisting of a vacuum pump, a sintered metal filter, electrically conductive rubber stopper and a stainless steel tube for transferring the milled powder into a reaction vial. In our preliminary experiments on carbonate powder, we achieved a rapid recovery of 5 to 100 µg of carbonate with a high recovery ratio (>90%). This technique shortens the sample preparation time, improves the recovery ratio, and homogenizes the sample quantity, which, in turn, improves the analytical reproducibility. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

20.
Referencing strategies and techniques in stable isotope ratio analysis   总被引:7,自引:0,他引:7  
Stable isotope ratios are reported in the literature in terms of a deviation from an international standard (delta-values). The referencing procedures, however, differ from instrument to instrument and are not consistent between measurement facilities. This paper reviews an attempt to unify the strategy for referencing isotopic measurements. In particular, emphasis is given to the importance of identical treatment of sample and reference material ('IT principle'), which should guide all isotope ratio determinations and evaluations. The implementation of the principle in our laboratory, the monitoring of our measurement quality, the status of the international scales and reference materials and necessary correction procedures are discussed.  相似文献   