首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A procedure for the determination of three phosphoric acid diesters, eight triesters and triphenylphosphine oxide (TPPO) in water samples is presented. Analytes were simultaneously concentrated using a mixed-mode (reversed-phase and anionic-exchange) solid-phase extraction (SPE) sorbent and then sequentially eluted with methanol (triesters and TPPO) followed by a 20 mM tetrabutylammonium hydrogen sulphate (TBAHS) methanolic solution, case of diesters. After that, they were determined, in two different runs, by liquid chromatography–electrospray ionization–tandem mass spectrometry (LC–ESI–MS/MS), operating the ESI source in the positive (triesters and TPPO) and negative (diesters) ionization modes. The efficiency of the extraction step varied between 70 and 105%, except in the case of tris(2-ethylhexyl) phosphate (TEHP), and it was barely affected by the type of water sample. Moreover, low signal suppression effects were noticed in the ESI ionization of extracts obtained from different environmental water samples. As a result, the standard addition methodology was only required for the accurate quantification of tri-substituted organophosphorus (OPs) species in wastewater samples. Limits of quantification of the optimized method ranged from 0.2 to 10 ng L−1, depending on the sample matrix and the considered compound. The analysis of river and wastewater samples confirmed the occurrence of several tri- and di-substituted OPs in the aquatic environment, with the highest concentrations corresponding to tris(butoxyethyl) phosphate (TBEP) and tris(chloropropyl) phosphate (TCPP).  相似文献   

2.
3.
This paper describes the development of an optimized method based on solid-phase extraction (SPE) followed by liquid chromatography–electrospray ionization tandem mass spectrometry (LC–MS/MS) for the simultaneous analysis of ten antibiotic compounds including tetracyclines, sulfonamides, macrolides and quinolones. LC–MS/MS sensitivity has been optimized by alterations to both LC and MS operations. Of the two high resolution columns tested, Waters Symmetry C18 endcapped and Agilent Zorbax Bonus-RP, the latter was found to show better performance in producing sharp peaks and clear separation for most of the target compounds. Optimization of the MS fragmentation collision and cone energy enhanced the peak areas of the target analytes. The recovery of the target compounds from water samples was most efficient on Waters Oasis HLB SPE cartridge, while methanol was shown to be the most suitable solvent for desorbing the compounds from SPE. In addition, acidification of samples prior to SPE was shown to enhance the recovery of the compounds. To ensure a satisfactory recovery, the flow rate through SPE should be maintained at ≤10 mL min−1. The method was successfully applied to the analysis of antibiotics from environmental water samples, with concentrations being <LOD in tap water, between <LOD to 28 ng L−1 in river water and between <LOD to 230 ng L−1 in sewage effluent.  相似文献   

4.
A simple, rapid and efficient method, dispersive liquid–liquid microextraction (DLLME) in conjunction with high-performance liquid chromatography (HPLC), has been developed for the determination of three carbamate pesticides (methomyl, carbofuran and carbaryl) in water samples. In this extraction process, a mixture of 35 µL chlorobenzene (extraction solvent) and 1.0 mL acetonitrile (disperser solvent) was rapidly injected into the 5.0 mL aqueous sample containing the analytes. After centrifuging (5 min at 4000 rpm), the fine droplets of chlorobenzene were sedimented in the bottom of the conical test tube. Sedimented phase (20 µL) was injected into the HPLC for analysis. Some important parameters, such as kind and volume of extraction and disperser solvent, extraction time and salt addition were investigated and optimised. Under the optimum extraction condition, the enrichment factors and extraction recoveries ranged from 148% to 189% and 74.2% to 94.4%, respectively. The methods yielded a linear range in the concentration from 1 to 1000 µg L?1 for carbofuran and carbaryl, 5 to 1000 µg L?1 for methomyl, and the limits of detection were 0.5, 0.9 and 0.1 µg L?1, respectively. The relative standard deviations (RSD) for the extraction of 500 µg L?1 carbamate pesticides were in the range of 1.8–4.6% (n = 6). This method could be successfully applied for the determination of carbamate pesticides in tap water, river water and rain water.  相似文献   

5.
A reliable multiclass method has been developed and validated for the determination of eight antibiotics from distinct classes (sulfonamides, macrolides, fluoroquinolones, tetracyclines, cephalosporins and dihydrofolate reductase inhibitors) in wastewater – influent and effluent – and surface water from Porto Alegre, Brazil. The pre-concentration and clean-up was conducted with a simple and fast protocol using solid-phase extraction allowing a 100-fold concentration factor. The proposed method was validated by using spiked blank wastewater samples in terms of linearity, repeatability, reproducibility, recovery, matrix effects and limits of detection and quantification. Recovery was obtained in the range of 66–149%. Method limit of quantification ranged between 1.6 and 61.7 ng L?1. Samples (n = 16) were taken from January to August 2011 in one wastewater treatment plant, which uses conventional biological treatment. Sulfamethoxazole and trimethoprim show higher concentration, ranging from >10 to <6500 ng L?1, whereas erythromycin presented the lower amount. Differences between influent and effluent profiles were discussed. Surface water samples (n = 8) were collected in Arroio Diluvio, in four sampling points, in February 2012. From the eight antibiotics analysed, five were detected: sulfamethoxazole, trimethoprim, azythromicyn, ciprofloxacin and norfloxacin, in a concentration range of 376–572 ng L?1, 27–94 ng L?1, 24–40 ng L?1, 16–66ng L?1 and 30–54 ng L?1, respectively.  相似文献   

6.
In the present work, a high-performance liquid chromatography–tandem mass spectrometry method has been developed for the residue analysis of chloramphenicol (CAP) in several food matrices. Following the addition of D5-CAP as internal standard, egg, honey, and milk were extracted and cleaned by means of solid-phase extraction, utilizing multi-walled carbon nanotubes as sorbent. The extracts were separated on a Halo fused-core C18 column (50 mm × 2.1 mm, 2.7 μm) and quantified by a 4000 Q-trap mass spectrometer equipped with a TurboIonSpray™ interface using electrospray ionization and multiple-reaction monitoring mode. The method validation was performed according to the criteria of Commission Decision 2002/657/EC. The decision limit (CCα) and detection capability (CCβ) of CAP in milk were calculated for m/z 320.8 > 151.9. Due to the existence of slight signal suppression, quantification was performed by matrix-matched calibration curves, ranging from 0.1 to 100 ng mL−1, with regression coefficients of 0.9993, 0.9998, and 0.9997 for egg, honey, and milk, respectively. Mean recoveries of the CAP ranged from 95.8% to 102.3%, with the corresponding intra- and inter-day variation (relative standard deviation) less than 7.13% and 8.89%, respectively. The limit of detection and limit of quantification of the method were also reported. This method successfully applied to several food matrixes (egg, honey, and milk) and can serve as a monitoring tool to avoid unacceptable levels of residues of CAP entering the food chain.  相似文献   

7.
Dispersive solid-phase extraction (DSPE) combined with dispersive liquid–liquid microextraction (DLLME) has been developed as a new approach for the extraction of four sulfonylurea herbicides (metsulfuron-methyl, chlorsulfuron, bensulfuron-methyl and chlorimuron-ethyl) in soil prior to high-performance liquid chromatography with diode array detection (HPLC-DAD). In the DSPE-DLLME, sulfonylurea herbicides were first extracted from soil sample into acetone–0.15 mol L−1 NaHCO3 (2:8, v/v). The clean-up of the extract by DSPE was carried out by directly adding C18 sorbent into the extract solution, followed by shaking and filtration. After the pH of the filtrate was adjusted to 2.0 with 2 mol L−1 HCl, 60.0 μL chlorobenzene (as extraction solvent) was added into 5.0 mL of it for DLLME procedure (the acetone contained in the solution also acted as dispersive solvent). Under the optimum conditions, the enrichment factors for the compounds were in the range between 102 and 216. The linearity of the method was in the range from 5.0 to 200 ng g−1 with the correlation coefficients (r) ranging from 0.9967 to 0.9987. The method detection limits were 0.5–1.2 ng g−1. The relative standard deviations varied from 5.2% to 7.2% (n = 5). The relative recoveries of the four sulfonylurea herbicides from soil samples at spiking levels of 6.0, 20.0 and 60.0 ng g−1 were in the range between 76.3% and 92.5%. The proposed method has been successfully applied to the analysis of the four target sulfonylurea herbicides in soil samples, and a satisfactory result was obtained.  相似文献   

8.
Pre-concentration and determination of 8 phenolic compounds in water samples has been achieved by in situ derivatization and using a new liquid–liquid microextraction coupled GC–MS system. Microextraction efficiency factors have been investigated and optimized: 9 μL 1-undecanol microdrop exposed for 15 min floated on surface of a 10 mL water sample at 55 °C, stirred at 1200 rpm, low pH level and saturated salt conditions. Chromatographic problems associated with free phenols have been overcome by simultaneous in situ derivatization utilizing 40 μL of acetic anhydride and 0.5% (w/v) K2CO3. Under the selected conditions, pre-concentration factor of 235–1174, limit of detection of 0.005–0.68 μg/L (S/N = 3) and linearity range of 0.02–300 μg/L have been obtained. A reasonable repeatability (RSD ≤ 10.4%, n = 5) with satisfactory linearity (0.9995 ≥ r2 ≥ 0.9975) of results illustrated a good performance of the present method. The relative recovery of different natural water samples was higher than 84%.  相似文献   

9.
A restricted access media–molecularly imprinted polymer (RAM–MIP) for cyclobarbital has been developed for selective extraction of antiepileptics in river water samples. The RAM–MIP was prepared using 4-vinylpyridine and ethylene glycol dimethacrylate as a functional monomer and cross-linker, respectively, by a multi-step swelling and polymerization method followed by a surface modification technique. The RAM–MIP for cyclobarbital showed molecular recognition abilities for phenobarbital, amobarbital and phenytoin as well as cyclobarbital. Thus, selective analysis of antiepileptics in river water samples was attained with RAM–MIP extraction followed by column-switching liquid chromatography–tandem mass spectrometry. The concentrations of phenobarbital and phenytoin in river water samples were about 15 and 4 ng/L, respectively, while that of amobarbital was below the limit of quantitation.  相似文献   

10.
Cytokinins (CTKs) are a class of growth-regulating hormones involved in various physiological and developmental processes. More novel analytical methods for the accurate identification and quantitative determination of trace CTKs in plants have been desired to better elucidate the roles of CTKs. In this work, a novel method based on monolithic molecularly imprinted solid-phase extraction followed by liquid chromatography–electrospray tandem mass spectrometry (mMI-SPE-LC-MS/MS) was developed for accurate determination of four CTKs in plant samples. The molecularly imprinted polymer monolith was prepared by using kinetin as the template in syringes and exhibited specific recognition ability for the four CTKs in comparison with that of non-imprinted polymer monolith. Several factors affecting the extraction performance of mMI-SPE, including the pH of loading sample solution, the nature and volume of elution solvent, the flow rate of sample loading, and sample volume, were investigated, respectively. Under the optimized conditions, the proposed mMI-SPE-LC-MS/MS method was successfully applied in the selective extraction and determination of four CTKs in plant tissues, and it offers detection limits (S/N?=?3) of 104, 113, 130, and 89 pg/mL and mean recoveries of 85.9%, 79.3%, 73.5%, and 70.1% for kinetin, kinetin glucoside, trans-zeatin, and meta-topolin (mT), respectively, with the corresponding RSDs less than 15%.
Figure
Trace determination of cytokinins in different plant samples by monolithic molecularly imprinted solid-phase extraction and liquid chromatography–mass spectrometry  相似文献   

11.
We have developed a method using on-line solid-phase extraction–high-performance liquid chromatography–tandem mass spectrometry (SPE-HPLC-MS/MS) and isotope dilution quantification to measure atrazine and seven atrazine metabolites in urine. The metabolites measured were hydroxyatrazine, diaminochloroatrazine, desisopropylatrazine, desethylatrazine, desethylatrazine mercapturate, atrazine mercaturate and atrazine itself. Our method has good precision (relative standard deviations ranging from 4 to 20% at 5, 10 and 50 ng/mL), extraction efficiencies of 67 to 102% at 5 and 25 ng/mL, relative recoveries of 87 to 112% at 5, 25, 50 and 100 ng/mL limits of detection (LOD) ranging from 0.03 to 2.80 ng/mL. The linear range of our method spans from the analyte LOD to 100 ng/mL (40 ng/mL for atrazine and atrazine mercapturate) with R 2 values of greater than 0.999 and errors about the slope of less than 3%. Our method is rapid, cost-effective and suitable for large-scale sample analyses and is easily adaptable to other biological matrices. More importantly, this method will allow us to better assess human exposure to atrazine-related chemicals. Figure A schematic representation showing the elution of the analytes from the solid-phase extraction cartridge onto the analytical column for chromatographic separation prior to MS/MS analysis  相似文献   

12.
Primary aromatic amines (PAAs) have been broadly studied due to their high toxicity. In this work a method for the analysis of 22 PAAs in aqueous simulants has been developed. The method is based on a solid-phase extraction step using cation-exchange cartridges and the subsequent analysis of the extracts by ultra-high-performance liquid chromatography with mass spectrometric detection. The recoveries obtained for all the amines analyzed ranged between 81 and 109%, linear range was between 0.03 and 75 μg L−1, with the RSD values between 4.5 and 13.4% and an average value of 7.5% and limits of detection at μg L−1 level. The method has been applied to two real samples obtained from migration experiments of polyurethane based laminates to simulant B (water with 3% (w/v) acetic acid) which represents the worst case for the migration of aromatic amines. The main amines found in both samples were methylenedianiline isomers, obtained from the corresponding residual diisocyanates used during polyurethane adhesive polymerization. The total amine concentration found was 26 and 6.3 μg of aniline equivalents per kg of food simulant.  相似文献   

13.
A solid-phase extraction (SPE) using multi-walled carbon nanotubes (MWCNTs) as adsorbent coupled with gas chromatography–mass spectrometry (GC–MS) method was developed for the determination of 16 polycyclic aromatic hydrocarbons (PAHs) in environmental water samples. Several condition parameters, such as extraction adsorbents, elution solvents and volumes, and sample loading flow rate and volume were optimized to obtain high SPE recoveries and extraction efficiency. 150 mg MWCNTs as sorbent presented high extraction efficiency of 16 PAHs due to the large specific surface area and high adsorption capacity of MWCNTs compared with the commercial C18 column (250 mg/2 mL). The calibration curves of 16 PAHs extracted were linear in the range of 20–5000 ng L−1, with the correlation coefficients (r2) between 0.9848 and 0.9991. The method attained good precisions (relative standard deviation, RSD) from 1.2% to 12.1% for standard PAHs aqueous solutions; method recoveries ranged in 76.0–125.5%, 74.5–127.0%, and 70.0–122.0% for real spiked samples from river water, tap water and seawater, respectively. Limits of detection (LODs, S/N = 3) of the method were determined from 2.0 to 8.5 ng L−1. The optimized method was successfully applied to the determination of 16 PAHs in real environmental water samples.  相似文献   

14.
The performance of the dispersive liquid–liquid microextraction (DLLME) technique for the determination of eight UV filters and a structurally related personal care species, benzyl salicylate (BzS), in environmental water samples is evaluated. After extraction, analytes were determined by gas chromatography combined with mass spectrometry detection (GC-MS). Parameters potentially affecting the performance of the sample preparation method (sample pH, ionic strength, type and volume of dispersant and extractant solvents) were systematically investigated using both multi- and univariant optimization strategies. Under final working conditions, analytes were extracted from 10 mL water samples by addition of 1 mL of acetone (dispersant) containing 60 μL of chlorobenzene (extractant), without modifying either the pH or the ionic strength of the sample. Limits of quantification (LOQs) between 2 and 14 ng L−1, inter-day variability (evaluated with relative standard deviations, RSDs) from 9% to 14% and good linearity up to concentrations of 10,000 ng L−1 were obtained. Moreover, the efficiency of the extraction was scarcely affected by the type of water sample. With the only exception of 2-ethylhexyl-p-dimethylaminobenzoate (EHPABA), compounds were found in environmental water samples at concentrations between 6 ± 1 ng L−1 and 26 ± 2 ng mL−1.  相似文献   

15.
This study reports a promising method of solid-phase extraction for determining the toluene, ethylbenzene, p-xylene, m-xylene, o-xylene, 1,3,5-trimethylbenzene, and 1,2,4-trimethylbenzene in water samples by gas chromatography–mass spectrometry (GC–MS). Prior to this procedure, the magnesium–aluminum bimetallic hydroxides modified with sodium dodecylbenzenesulfonate (Mg/Al-SDBS-LDH) were prepared and served as the novel solid-phase extractant. The Mg/Al-SDBS-LDH has advantage of good hydrophobicity and larger spacing which facilitates the monoaromatic hydrocarbons (MAHCs) into the interlayer for adsorption. As a result, the seven MAHCs in 500 mL water samples were enriched greatly, and the theoretical enrichment factor reached to 125 times. Under the optimized conditions of solid-phase extraction (SPE) and GC–MS, the mass concentration of each MAHC (0.005–10, 0.01–10, or 0.05–10 ng/mL) had a fine linear relationship with peak area. The correlation coefficients were more than 0.995. The detection limits were between 0.001 and 0.01 ng/mL, and the RSD were between 3.1% and 6.6%. The method had been applied to determine the seven MAHCs in the Dongfengqu river water and laboratory wastewater of Chengdu University of Technology successfully.  相似文献   

16.
A method involving solid-phase extraction (SPE) and reversed-phase liquid chromatography–mass spectrometry (LC–MS) has been developed for determination, in groundwater, of nitrobenzoic acids associated with 2,4,6-trinitrotoluene production. Pre-concentration on a co-polymer-based SPE cartridge enabled quantitative extraction of the analytes from water. Investigation of negative ion electrospray and atmospheric-pressure chemical ionization mass spectrometry indicated the sensitivity of APCI was more than twice that of ESI. An 15N-labeled internal standard was used to achieve more accurate quantitation and mass assignment. Recovery was better than 80% when 10 mL water was extracted with the SPE cartridge. Combination of SPE with LC–MS analysis resulted in method detection limits of less than 5 μg L−1. The method has been used for analysis of groundwater samples collected from a site of a former ammunition plant. Contamination with nitrobenzoic acids was determined at μg L−1 levels.  相似文献   

17.
An in-syringe demulsified dispersive liquid–liquid microextraction (ISD–DLLME) technique was developed using low-density extraction solvents for the highly sensitive determination of the three trace fungicides (azoxystrobin, diethofencarb and pyrimethanil) in water samples by high performance liquid chromatography–mass spectrometry chromatography–diode array detector/electrospray ionisation mass spectrometry. In the proposed technique, a 5-mL syringe was used as an extraction, separation and preconcentration container. The emulsion was obtained after the mixture of toluene (extraction solvent) and methanol (dispersive solvent) was injected into the aqueous bulk of the syringe. The obtained emulsion cleared into two phases without centrifugation, when an aliquot of methanol was introduced as a demulsifier. The separated floating organic extraction solvent was impelled and collected into a pipette tip fitted to the tip of the syringe. Under the optimal conditions, the enrichment factors for azoxystrobin, diethofencarb and pyrimethanil were 239, 200, 195, respectively. The limits of detection, calculated as three times the signal-to-noise ratio (S N−1), were 0.026 μg L−1 for azoxystrobin, 0.071 μg L−1 for diethofencarb and 0.040 μg L−1 for pyrimethanil. The repeatability study was carried out by extracting the spiked water samples at concentration levels of 0.02 μg mL−1 for all the three fungicides. The relative standard deviations varied between 4.9 and 8.2% (n = 5). The recoveries of all the three fungicides from tap, lake and rain water samples at spiking levels of 0.2, 1, 5 μg L−1 were in the range of 90.0–105.0%, 86.0–114.0% and 88.6–110.0%, respectively. The proposed ISD–DLLME technique was demonstrated to be simple, practical and efficient for the determination of different kinds of fungicide residues in real water samples.  相似文献   

18.
A rapid, accurate and sensitive method for simultaneous determination of 15 steroidal hormones including four estrogens (estrone, 17β-estradiol, 17α-ethynylestradiol, estriol) and eleven progestogens (17β-estradiol-3-benzoate, 19-norethindrone, gestodene, levonorgestrel, medroxyprogesterone, cyproterone acetate, megestrol-17-acetate, progesterone, norethindrone acetate, chlormadinone-17-acetate, and hydroxy progesterone caproate) in environmental waters was developed by coupling solid-phase disk extraction (SPDE) to ultra performance liquid chromatography–tandem mass spectrometry (UPLC–MS/MS) with electrospray ionization. Among three types of extraction tested (C8 SPDE, C18 SPDE and C18 SPE), the most satisfactory result was achieved using C18 SPDE for its satisfactory recovery (75.6 to 101.4%) and short extraction time (15 min for 1 L deionised water). The validity of this method was investigated and good analytical performance for all the analytes was obtained, including low limits of method detection (0.5–3.4 ng/L) and excellent linear dynamic range (1.0–50.0 ng/L). The method was applied to determine the steroidal hormones in 10 environmental waters including tap water, river water, lake water and waste water in Beijing. No progestogen was detected in all samples and estrone, estriol, 17α-ethynylestradiol were found in most samples at levels between 1.8 and 127.9 ng/L.  相似文献   

19.
This paper demonstrates, for the first time, the great potential of using Zn/Al layered double hydroxide intercalated sodium dodecyl benzene sulfonate (Zn/Al-SDBS-LDH) as a solid-phase extraction (SPE) material in the extraction of persistent organic pollutants prior to the determination of gas chromatography-mass spectrometry in environmental water samples. Zn/Al-SDBS-LDH, a relatively inexpensive and simply prepared material, was synthesized and used as a SPE adsorbent to quantitatively determine the concentration of five polycyclic aromatic hydrocarbons (PAHs) in environmental water samples. Factors affecting extraction efficiency, such as, eluent type, eluent volume, flow rate of sample, sample volume, and amount of adsorbent, were investigated and optimized in detail. Experimental results indicate that there is an excellent linear relationship between peak area and the concentration of PAHs over the range of 5-500 ng L(-1), and the precisions (relative standard deviation (RSD)) were 2.5-6.3% under the optimum conditions. Based on the ratio of chromatographic signal-to-base line noise (S/N = 3), the limits of detection could reach 1.2-3.2 ng L(-1). This novel method was successfully applied to the analysis of PAHs in environmental water samples. As such, we show here that the use of Zn/Al-SDBS-LDH as SPE adsorbent materials, coupled with gas chromatography-mass spectrometry, is an excellent improvement in the routine analysis of PAHs at trace levels in the environment.  相似文献   

20.
The aqueous instability of pyrethroids and other compounds usually found in commercial pesticide formulations has been demonstrated in this work. Several types of sample treatment have been studied to avoid analyte losses during sample manipulation and storage. Analysis was performed by SPME–GC–MS. Addition of sodium thiosulfate to tap water prevented pyrethroid degradation as a result of oxidation by free chlorine. The amount added was optimized to minimize the effect of the salt on the analytical results. Analysis of samples that had been stored at 4 °C for several days revealed loss of some of the pyrethroids in the first period of storage. The effect of freezing the samples was studied and it was confirmed that samples could be stabilized for at least one week by freezing. Finally, addition of a miscible organic solvent, for example acetone, led to improvement of the analytical precision. The quality of the SPME–GC–MS method was studied. Linearity (R > 0.993), repeatability (RSD < 15%), and sensitivity (detection limits between 0.9 and 35 pg mL−1) were good. When the procedure was applied to real samples including run off and waste water some of the target compounds were identified and quantified.   相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号