首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 203 毫秒
1.
2.
In the present work we report the results obtained with a methodology based on direct coupling of a headspace generator to a mass spectrometer for the identification of different types of petroleum crudes in polluted soils. With no prior treatment, the samples are subjected to the headspace generation process and the volatiles generated are introduced directly into the mass spectrometer, thereby obtaining a fingerprint of volatiles in the sample analysed. The mass spectrum corresponding to the mass/charge ratios (m/z) contains the information related to the composition of the headspace and is used as the analytical signal for the characterization of the samples. The signals obtained for the different samples were treated by chemometric techniques to obtain the desired information. The main advantage of the proposed methodology is that no prior chromatographic separation and no sample manipulation are required. The method is rapid, simple and, in view of the results, highly promising for the implementation of a new approach for oil spill identification in soils. Figure PCA score plots illustrate clear discrimination of types of crude oil in polluted soil samples (e.g. results are shown for vertisol)  相似文献   

3.
Figure Schematic diagram of a typical arrangement used for hyphenating chemical microseparations (e.g. capillary HPLC, CE, or CEC) with microcoil NMR detection  相似文献   

4.
SPME in environmental analysis   总被引:1,自引:0,他引:1  
Recent advances in the use of solid-phase microextraction (SPME) in environmental analysis, including fiber coatings, derivatization techniques, and in-tube SPME, are reviewed in this article. Several calibration methods for SPME, including traditional calibration methods, the equilibrium extraction method, the exhaustive extraction method, and several diffusion-based calibration methods, are presented. Recent developed SPME devices for on-site sampling and several applications of SPME in environmental analysis are also introduced.   相似文献   

5.
A method has been developed for rapidly separating and detecting strychnine and brucine using a poly(dimethysiloxane) (PDMS) microchip and electrochemical (EC) detection. PDMS microchannels dynamically modified by Brij35 are shown to be more efficient than native ones. The two analytes are well separated within 90 s in 70 mmol/L acetate buffer (pH 5.5) containing 0.01% (v/v) Brij35. Detection limits were found to be 1.0 μmol/L for strychnine and 0.2 μmol/L for brucine at S/N=3. The method was used to determine trace strychnine and brucine in rat serum, and the results obtained correlate well with those obtained via high-performance liquid chromatography (HPLC).   相似文献   

6.
We have developed a concise tool for the investigation of the transition of humic substances in environmental water. The separation of water-soluble humic substances was achieved rapidly and effectively by capillary electrophoresis using a polyacrylamide-coated capillary and a phosphate electrophoretic buffer solution (pH 7.0) containing hydroxyethyl cellulose. The separation mechanism was assessed using the ultrafiltration technique. The effect of the complexation of humic substances with metal ions was studied by using the proposed method. When Fe(III) ions or EDTA was added to the sample solution of fulvic acid, a distinct change in the electropherogram pattern based on the conformational change of fulvic acid was observed. The successful application of the proposed method to the characterization of humic substances in a river water sample was also demonstrated. Figure Addition of Fe(III) ions or EDTA to a solution containing fulvic acid (FA) results in a distinct change in the electropherogram pattern, which reflects the conformational change of FA: this forms the basis for the characterization of humic substances in river water samples  相似文献   

7.
In this study a new spectrofluorimetric method for the direct determination of metoprolol in human plasma is presented and discussed. It is based on the use of fluorescence excitation–emission matrices (EEMs) and second-order calibration performed with parallel factor analysis (PARAFAC) or alternating trilinear decomposition (ATLD). This methodology enables accurate and reliable discrimination of the analyte signal, even in the presence of unknown and uncalibrated fluorescent component(s), which is often referred to as the second-order advantage. No separation or sample pretreatment steps were required. Satisfactory results were obtained. Metoprolol recoveries in plasma were determined as 87±2% and 90±4% with PARAFAC and ATLD, respectively. All RSD values of intra- and interday assays were below 5%. Figure A three-dimensional plot of EEMs for a plasma sample and metoprolol solution  相似文献   

8.
It is shown that organo-aqueous separation buffers show much promise when used in capillary electrophoresis separations with photothermal (thermal lens) detection systems. Acetonitrile–water and methanol–water mixtures were selected, as conventionally used in capillary electrophoresis. It is shown that, despite more sophisticated experimental conditions (significant heat outflow from the capillary body) and peak detection, the theoretical ratio of the thermal lens signal for a binary mixture to the thermal lens signal for an aqueous solution (or the corresponding ratio obtained experimentally under bulk batch conditions) can be used to predict the sensitivity of thermal lens detection in capillary electrophoresis. The limits of detection for 2-, 3-, and 4-nitrophenols selected as model compounds in 70% v/v acetonitrile separation buffers are 1×10−6 M, 1×10−6 M and 3×10−7 M, respectively, and are therefore decreased by a factor of six compared to thermal lens detection in aqueous separation buffers. The overall increase in the thermal lens detection sensitivity in a 100% ACN buffer is a factor of 13.   相似文献   

9.
A simple method based on capillary electrophoresis with potential gradient detection was developed to separate and detect neomycin components within 4 min without a derivatization step. Satisfactory separation and good repeatability were obtained using a separation buffer composed of 1 mM ammonium citrate (pH 3.5). The linearity of the method ranged from 10 to 1000 ppm with a limit of detection for neomycin B of about 7 ppm. After a simple dilution and filtering pretreatment step, neomycin components in three real samples were successfully analyzed without any major interference. Due to its simplicity and reliability, this method could provide an excellent alternative to the assays currently listed in U.S. and European Pharmacopoeia. The experiments were performed on a portable capillary electrophoresis system and, hence, the method can be readily applied to field analysis and point-of-care testing. Figure Photo of portable CE-P2-PGD system  相似文献   

10.
Because variability exists within populations of cells, single-cell analysis has become increasingly important for probing complex cellular environments. Capillary electrophoresis (CE) is an excellent technique for identifying and quantifying the contents of single cells owing to its small volume requirements and fast, efficient separations with highly sensitive detection. Recent progress in both whole-cell and subcellular sampling has allowed researchers to study cellular function in the areas of neuroscience, oncology, enzymology, immunology, and gene expression.   相似文献   

11.
The analytical methodology for speciation of metals and metalloids associated with alkyl groups and biomacromolecules is critically reviewed. Alkylated metals and metalloids are not only known to be produced by microbial methylation within most anaerobic compartments in the environment, but also in the course of enzymatic transformations during human metabolism. Because of the toxicological relevance of these compounds present in trace to ultratrace concentrations, firm species identification and exact quantification are essential. While many instrumental techniques coupling chromatography (GC, HPLC, CE, GE) with plasma mass spectrometry (ICP-MS) are available for quantification, methods used for structural identification often suffer from inadequate sensitivity (EI-MS, ESI-MS, MALDI-MS, FT-ICRMS). Other problems encountered are sample derivatisation artefacts, lack of suitable standards for quantification, lack of equilibrium between spikes and sample, and the integrity of metal–protein association during separation, in particular during SDS-PAGE. Selected application examples with respect to mercury and arsenic speciation will be discussed critically.   相似文献   

12.
A fast and sensitive approach that can be used to detect norfloxacin in human urine using capillary electrophoresis with end-column electrochemiluminescence (ECL) detection of is described. The separation column was a 75-μm i.d. capillary. The running buffer was 15 mmol L−1 sodium phosphate (pH 8.2). The solution in the detection cell was 50 mmol L−1 sodium phosphate (pH 8.0) and 5 mmol L−1 The ECL intensity varied linearly with norfloxacin concentration from 0.05 to 10 μmol L−1. The detection limit (S/N=3) was 0.0048 μmol L−1, and the relative standard deviations of the ECL intensity and the migration time for eleven consecutive injections of 1.0 μmol L−1 norfloxacin (n=11) were 2.6% and 0.8%, respectively. The method was successfully applied to the determination of norfloxacin spiked in human urine without sample pretreatment. The recoveries were 92.7–97.9%.   相似文献   

13.
The general nanoprinting and nanoinjection of proteins on non-conducting or conducting substrates with a high degree of control both in terms of positional and timing accuracy is an important goal that could impact diverse fields from biotechnology (protein chips) to molecular electronics and from fundamental studies in cell biology to nanophotonics. In this paper, we combine capillary electrophoresis (CE), a separation method with considerable control of protein movement, with the unparalleled positional accuracy of an atomic force microscope (AFM). This combination provides the ability to electrophoretically or electroosmotically correlate the timing of protein migration with AFM control of the protein deposition at a high concentration in defined locations and highly confined volumes estimated to be 2 al. Electrical control of bovine serum albumin printing on standard protein-spotting glass substrates is demonstrated. For this advance, fountain pen nanolithography (FPN) that uses cantilevered glass-tapered capillaries is amended with the placement of electrodes on the nanopipette itself. This results in imposed voltages that are three orders of magnitude less than what is normally used in capillary electrophoresis. The development of atomic-force-controlled capillary electrophoretic printing (ACCEP) has the potential for electrophoretic separation, with high resolution, both in time and in space. The large voltage drop at the tip of the tapered nanopipettes allows for significant increases in concentration of protein in the small printed volumes. All of these attributes combine to suggest that this methodology should have a significant impact in science and technology.   相似文献   

14.
Detailed information on the geochemical behavior of radioactive and toxic metal ions under environmental conditions (in geological matrices and aquifer systems) is needed in order to assess the long-term safety of waste repositories. This includes knowledge of the mechanisms of relevant geochemical reactions, as well as associated thermodynamic and kinetic data. Several previous studies have shown that humic acid can play an important role in the immobilization or mobilization of metal ions due to complexation and colloid formation. In our project we investigate the complexation behavior of (purified Aldrich) humic acid and its influence on the migration of the lanthanides europium and gadolinium (homologs of the actinides americium and curium) in the ternary system consisting of these heavy metals, humic acid and kaolinite (KGa-1b) under almost natural conditions. Capillary electrophoresis (CE, Beckman Coulter P/ACE MDQ), with its excellent separation performance, was hyphenated with a homemade interface to inductively coupled plasma mass spectrometry (ICP–MS, VG Elemental PlasmaQuad 3) giving a system that is highly sensitive to the rare-earth element species of europium and gadolinium with humic acid. The humic acid used was also halogenated with iodine, which acted as an ICP–MS marker. To couple CE to ICP–MS, a fused silica CE capillary was flexibly fitted into a MicroMist 50 μl nebulizer with a Cinnabar cyclonic spray chamber in the external homemade interface. The chamber was chilled to a temperature of 4 °C to optimize the sensitivity. 200 ppb of cesium were added to the CE separation buffer so that the capillary flow could be observed. A make-up fluid including 4 ppb Ho as an internal standard was combined with the flow from the capillary within the interface in order to get a fluid throughput high enough to maintain continuous nebulization. Very low detection limits were achieved: 125 ppt for 153Eu and 250 ppt for 158Gd. Using this optimized CE–ICP–MS coupling system it was possible to quantify metal concentrations from the detection limit up to approximately 1 ppm (the linear range). This set-up was used to separate metal/humic acid-species in a 100 mM acetic acid/10 mM acetate buffer system. Using humic acid as the complexing ligand, uncomplexed metal ion species could be separated from metal–humate complexes on a time-resolved scale.   相似文献   

15.
We quantitatively modeled the volume phase transition of a hydrogel containing a crystalline colloidal array with a crown ether ligand which binds Pb2+. The hydrogel volume response and the wavelength diffracted depend on the Pb2+ concentration and on both the ionic strength and the valence of the nonbinding ionic species. We successfully modeled the response of this hydrogel Pb2+ sensor to ionic strength and the cation valence of the added salts. Figure Cation identity dependence of crown ether photonic crystal Pb+ sensing  相似文献   

16.
An optical capillary waveguide fluoroimmunosensor based on glass capillaries internally coated with an ultrathin poly(dimethylsiloxane) (PDMS) film is presented. The evaluation of the capillaries developed was done in comparison with aminosilanized [3-(aminopropyl)triethoxysilane, APTES] glass and poly(methylpentene) (PMP) capillaries by immobilizing rabbit γ-globulins on the internal capillary wall. Following reaction with (R)-phycoerythrin-labelled antibody, the capillary was scanned with a laser beam and the fluorescence waveguided through the capillary wall was detected by a photomultiplier placed at one of its ends. The capillaries developed provided considerably improved protein coating homogeneity (intracapillary coefficients of variation 2.9–6.6%) and repeatability (intercapillary coefficients of variation 2.1–5.0%) compared with APTES-treated ones (7.9–13.4 and 8.5–15.2%, respectively). With use of these capillaries in a sandwich-type immunosensor for the determination of rabbit γ-globulins, the assay detection limit was improved eightfold (4.4 ng/mL) compared with that obtained using PMP capillaries (35.3 ng/mL), whereas the assay repeatability was improved threefold (intra-assay coefficients of variation 5.9–13.1%) compared with APTES-treated capillaries (15.6–36%). Optoelectronic set-up used to scan the capillaries (left) and representative fluorescence scannings of dual-band poly(methylpentene) (PMP), PDMS-modified glass and APTES treated glass capillaries  相似文献   

17.
18.
Reactive oxygen species (ROS) and reactive nitrogen species (RNS) play a crucial role in chemical signaling processes of biological cells. Electrochemistry is one of the rare methods able to directly detect these species. ROS and RNS can be monitored in the local microenvironment of cells in real time at the site where the actual signaling takes place. This review presents recent advances made with amperometric electrochemical techniques. Existing challenges for the quantification of ROS and RNS in biological systems are discussed to promote the development of innovative and reliable cell-based assays. Figure Reactive oxygen and nitrogen species (ROS & RNS) are produced biological cells. An amperometric sensor is placed in close proximity. The recorded current I is used to determine fluxes of certain species.
Sabine BorgmannEmail:
  相似文献   

19.
We investigated properties of cells affecting their optical trapping force and successfully established a novel cell separation method based on the combined use of optical trapping force and microfluidics on a microchip. Our investigations reveal that the morphology, size, light absorption, and refractive index of cells are important factors affecting their optical trapping force. A sheath flow of sample solutions created in a microchip made sample cells flow in a narrow linear stream and an optical trap created by a highly focused laser beam captured only target cells and altered their trajectory, resulting in high-efficiency cell separation. An optimum balance between optical trapping force and sample flow rate was essential to achieve high cell separation efficiency. Our investigations clearly indicate that the on-chip optical trapping method allows high-efficiency cell separation without cumbersome and time-consuming cell pretreatments. In addition, our on-chip optical trapping method requires small amounts of sample and may permit high-throughput cell separation and integration of other functions on microchips. Figure Optical trapping in a microchannel allows high-efficiency separation of cells, e.g., dead and live HeLa cells
Yukihiro OkamotoEmail:
  相似文献   

20.
Capillaries (25-and 50-μm inner diameter) coated with a double-alkyl-chain cationic surfactant N,N-didodecyl-N,N-dimethylammonium bromide (DDAB) were used for the separation of four basic standard proteins in buffers of pH 4 at various ionic strengths. The choice of buffer is critical for the analytical performance. Ammonium ions must be avoided in the buffer used in the non-covalent coating procedure owing to competition with the surfactant. Phosphate buffer gave a better separation performance than some volatile buffers; the reason seems to be a complex formation between the proteins and dihydrogenphosphate ions, which decreases tendencies for adsorption to the capillary surface. The DDAB coating was easy to produce and stable enough to permit, without recoating, consecutive separations of the proteins for up to 100 min with good precision in migration times and peak areas. A strong electroosmotic flow gives rapid separations, which is of special importance when commercial instruments are used, since the choice of the length of the capillary is restricted. Figure EOF stability in 25 micrometer i.d. capillaries. Consecutive injections of mesityloxide performed after an initial coating with 1.0  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号