首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 24 毫秒
1.
We evaluated a novel strategy for high-sensitivity DNA fragment analysis in a conventional glass double-T microfluidic chip. The microchip allows for a DNA on-channel concentration based on base stacking (BS) with a microchip capillary gel electrophoretic (MCGE) separation step in a poly(vinylpyrrolidone) (PVP) sieving matrix. Depending if low conductivity caused a neutralization reaction between the hydroxide ions and the run buffer component Tris+, the stacking of DNA fragments were processed in the microchip. Compared to a conventional MCGE separation with a normal electrokinetic injection, the peak heights of 50-2650-base pair (bp) DNA fragments on the MCGE-BS separation were increased 3.9-8.0-fold. When we applied the MCGE-BS method to the analysis of a clinical sample of bovine theileria after PCR reaction, the peak height intensity of the amplified 816-bp DNA fragment from the 18S rRNA of T. buffeli was enhanced 7.0-fold compared to that of the normal injection method.  相似文献   

2.
Microchip electrophoresis has become a powerful tool for DNA separation, offering all of the advantages typically associated with miniaturized techniques: high speed, high resolution, ease of automation, and great versatility for both routine and research applications. Various substrate materials have been used to produce microchips for DNA separations, including conventional (glass, silicon, and quartz) and alternative (polymers) platforms. In this study, we perform DNA separation in a simple and low-cost polyester-toner (PeT)-based electrophoresis microchip. PeT devices were fabricated by a direct-printing process using a 600 dpi-resolution laser printer. DNA separations were performed on PeT chip with channels filled with polymer solutions (0.5% m/v hydroxyethylcellulose or hydroxypropylcellulose) at electric fields ranging from 100 to 300 V cm(-1). Separation of DNA fragments between 100 and 1000 bp, with good correlation of the size of DNA fragments and mobility, was achieved in this system. Although the mobility increased with increasing electric field, separations showed the same profile regardless of the electric field. The system provided good separation efficiency (215,000 plates per m for the 500 bp fragment) and the separation was completed in 4 min for 1000 bp fragment ladder. The cost of a given chip is approximately $0.15 and it takes less than 10 minutes to prepare a single device.  相似文献   

3.
Sun M  Lin JS  Barron AE 《Electrophoresis》2011,32(22):3233-3240
Double-stranded (ds) DNA fragments over a wide size range were successfully separated in blended polymer matrices by microfluidic chip electrophoresis. Novel blended polymer matrices composed of two types of polymers with three different molar masses were developed to provide improved separations of large dsDNA without negatively impacting the separation of small dsDNA. Hydroxyethyl celluloses with average molar masses of ~27 kDa and ~1 MDa were blended with a second class of polymer, high-molar mass (~7 MDa) linear polyacrylamide. Fast and highly efficient separations of commercially available DNA ladders were achieved on a borosilicate glass microchip. A distinct separation of a 1-kb DNA extension ladder (200-40,000 bp) was completed in 2 min. An orthogonal design of experiments was used to optimize experimental parameters for DNA separations over a wide size range. We find that the two dominant factors are the applied electric field strength and the inclusion of a high concentration of low-molar mass polymer in the matrix solution. These two factors exerted different effects on the separations of small dsDNA fragments below 1 kbp, medium dsDNA fragments between 1 and 10 kbp, and large dsDNA fragments above 10 kbp.  相似文献   

4.
宋立国  陈洪  张乐  程介克 《色谱》1999,17(4):379-382
通过理论推导和实验验证表明;适当稀释DNA样品溶液,采用流体力学进样或电动进样都不会较大地减低峰高,而DNA片段毛细管电泳的分离效率和分离度还能有所提高。采用稀释样品的方法可提高DNA样品的使用效率。采用羟乙基纤维素无胶筛分介质分离了DNA片段。用激光诱导荧光(氩离子激光器,488nm)电荷耦合器件检测。用低浓度的筛分介质(0.4%)分离了分子质量较大的ADNA-HindⅢ全部8个片段(12bp~23130bP)。用高浓度的筛分介质(1.6%)分离分子质量较小的pBR322-HaeⅢ22个片段(18bp~587bp)。  相似文献   

5.
A high‐speed DNA fragment separation system based on an on‐line combination of capillary ITP with CZE (CITP‐CZE) and using UV detection at 260 nm was developed. A novel CITP‐CZE buffer system of pH 6.1 was designed for the separation of ten DNA fragments with sizes ranging from 100 to 1000 bp. An effect of underivatized α‐, β‐ and γ‐cyclodextrins on the resolution of DNA fragments in the CZE step of the CITP‐CZE combination was systematically investigated. Methylhydroxyethylcellulose present in the BGE was used to eliminate the EOF. DNA ladder fragments were separated within 10 min with LODs in the range of 1–5 ng/μL (S/N = 3). The RSDs of the migration time and peak area of individual DNA fragments were in the range of 1–3 and 3–9%, respectively. The developed CITP‐CZE system was further applied to the analysis of digest plasmid DNA samples.  相似文献   

6.
聚环氧乙烷无胶筛分毛细管电泳分离宽分子量范围DNA片段   总被引:1,自引:0,他引:1  
在无胶筛分毛细管电泳中,以聚环氧乙烷为筛分介质,用硅烷化处理的毛细管柱(31.2 cm×75 μm有效长度21.0 cm)分离DL5000 DNA Marker(DNA长度为100~5000 bp),研究筛分介质浓度、缓冲液pH、分离电压和溴化乙锭浓度对分离双链DNA片段的影响,优化出分离100~5000 bp DNA片段的最佳条件。毛细管电泳的最佳条件为PEO浓度0.5%、缓冲液pH值8.0、电压12 kV、溴化乙锭浓度3.0 μg/mL。此条件下,对山梨醇脱氢酶基因(SDH)和乙烯受体基因(ETR1)的聚合酶链式反应(PCR)扩增产物同时检测,分离、鉴定效果良好。  相似文献   

7.
Sun K  Li Z  Ueno K  Juodkazis S  Noji S  Misawa H 《Electrophoresis》2007,28(10):1572-1578
We report the high fidelity, on-chip fractionation of selected segments from an electrophoretic flow of separated fragments. dsDNA fragments (10-330 base pairs (bp)) were initially separated using a 6.5 cm long channel with an electric field strength of 150 V/cm. As an example of the fractionation process, a target fragment of 20 bp was selected and extracted from the separation channel. The extraction was confirmed and evaluated by fluorescence imaging. High resolution and extraction fidelity were achieved by introducing new procedures for (i) extraction channel-blocking and (ii) segment transfer with cleaning. These procedures are necessary for the development of a practical, fully automated multitarget fractionation electrophoretic chip. A kind of CCD image processing method was introduced to monitor, control, and evaluate the procedure of fractionation. The resolution limits of the separation and extraction are discussed.  相似文献   

8.
A methodology has been developed which significantly reduces the linear dimension necessary for the electrophoretic separation of DNA fragments and oligonucleotides. DNA fragments are rapidly separated into compact, resolvable microscopic banding patterns which can be detected using a high-resolution electronic imaging system. Separations can be carried out in either capillary tube or thin-layer (slab) microgel formats of one centimeter or less in length. The complete separation of all eleven fragments (1353 to 72 base pairs) of the pi X174 DNA/HaeIII restriction ladder was achieved in a total running distance of less than 2 mm and in less than 2 min. The observed band widths for the larger fragments (1353-603 bp) ranged from 18 to 25 microns, with the intermediate and smaller fragments (310 to 72 bp) ranging from 30 microns to 60 microns. The ethidium bromide-stained microgels were analyzed using an epifluorescent microscope combined with an intensified charged coupled device imaging system. In other experiments, single-base resolution of fluoresceinated oligonucleotides in the 20-30 nucleotide range was demonstrated. DNA sequencing may be possible with further optimization. This new methodology departs from the conventional gel formulations and electrophoretic procedures used for the separation DNA fragments. High voltage gradients and the use of highly concentrated and crosslinked homogeneous polyacrylamide gels effects the rapid separation of DNA fragments in very short distances. Analysis of the microgels with proteins of known size (Stokes radius) indicates that separations are occurring in gels with pore sizes close to the diameter of double-stranded DNA.(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

9.
The research adopted a single-channel microchip as the probe, and focused electrokinetic injection combined with transient isotachophoresis preconcentration technique on capillary electrophoresis microchip to improve the analytical sensitivity of DNA fragments. The channel length, channel width and channel depth of the used microchip were 40.5 mm, and 110 and 50 μm, respectively. The separation was detected by CCD (charge-coupled device) (effective LENGTH=25 mm, 260 nm). A 1/100 diluted sample (0.2 mg/l of each DNA fragment) of commercially available stepladder DNA sample could be baseline separated in 120 s with S/N=2–5. Compared with conventional chip gel electrophoresis, the proposed method is ideally suited to improve the sensitivity of DNA analysis by chip electrophoresis.  相似文献   

10.
The mobilities of normal and anomalously migrating DNA fragments were determined in polyacrylamide gels of different acrylamide concentrations, polymerized with 3% N,N'-methylenebisacrylamide as the crosslinker. The DNA samples were a commercially available 123-bp ladder and two molecular weight ladders containing multiple copies of two 147-base pair (bp) restriction fragments, obtained from the MspI digestion of plasmid pBR322. One of the 147 bp fragments is known to migrate anomalously slowly in polyacrylamide gels. Ferguson plots were constructed for all multimer ladders, using both absolute mobilities and relative mobilities with respect to the smallest DNA molecule in each data set. If the retardation coefficients were calculated from the relative mobilities, and the rms radius of gyration was used as the measure of DNA size, the Ogston equations were obeyed and the gel fiber parameters could be calculated. The effective pore sizes of the gels were estimated from the gel concentration at which the mobility of a given DNA molecule was reduced to one-half its mobility at zero gel concentration. The estimated pore radii ranged from approximately 130 nm for 3.5% gels to approximately 70 nm for 10.5% gels. These values are much larger than the pore sizes previously determined for the polyacrylamide matrix.  相似文献   

11.
This study reports improved pulsed field capillary electrophoresis (PFCE) for separation of large DNA ladders. Important analytical conditions, including gel polymer concentration, ratio of forward to backward pulse duration, and separation potential, were investigated for their effects on the separation performance of DNA ranging in size from 0.1 to 10.0 kilo base pairs (kbp). Results show that DNA fragments from 0.1 to 8.0 kbp can be resolved with high resolution, simultaneously, in a short time. The ratio of forward to backward pulse duration affects the separation performance for DNA fragments greater than 1.5 kbp, and 3 or 4 is the optimum value of the ratio for separation of DNA up to 10 kbp. Furthermore, the separations that were obtained with 74–19,329 bp λ-DNA restriction fragments clearly demonstrate a dramatic improvement in the separation time and resolution over the conventionally used square-wave PFCE. The inversion field capillary electrophoresis reported here may help enable future DNA analysis studies to be performed quickly and effectively.  相似文献   

12.
Poly(dimethylsiloxane) (PDMS) membrane valves were utilized for diaphragm pumping on a PDMS-glass hybrid microdevice in order to couple infrared-mediated DNA amplification with electrophoretic separation of the products in a single device. Specific amplification products created during non-contact, infrared (IR) mediated polymerase chain reaction (PCR) were injected via chip-based diaphragm pumping into an electrophoretic separation channel. Channel dimensions were designed for injection plug shaping via preferential flow paths, which aided in minimizing the plug widths. Unbiased injection of sample could be achieved in as little as 190 ms, decreasing the time required with electrokinetic injection by two orders of magnitude. Additionally, sample stacking was promoted using laminar or biased-laminar loading to co-inject either water or low ionic strength DNA marker solution along with the PCR-amplified sample. Complete baseline resolution (Res = 2.11) of the 80- and 102-bp fragments of pUC-18 DNA marker solution was achieved, with partially resolved 257- and 267-bp fragments (Res = 0.56), in a separation channel having an effective length of only 3.0 cm. This resolution was deemed adequate for many PCR amplicon separations, with the added advantage of short separation time-typically complete in <120 s. Decreasing the amount of glass surrounding the PCR chamber reduced the DNA amplification time, yielding a further enhancement in analysis speed, with heating and cooling rates as high as 13.4 and -6.4 degrees C s(-1), respectively. With the time requirements greatly reduced for each step, it was possible to seamlessly couple IR-mediated amplification, sample injection, and separation/detection of a 278-bp fragment from the invA gene of <1000 starting copies of Salmonella typhimurium DNA in approximately 12 min on a single device, representing the fastest PCR-ME integration achieved to date.  相似文献   

13.
In this work, it was demonstrated that on-line pre-concentration and separation of DNA fragments within bared silica column by dynamic coating capillary electrophoresis and UV detection. The DNA fragments were pre-concentrated with long electrokinetic injecting time (99 s), peak height increased dramatically as a function of injection time, especially for shorter length DNA. The concentration sensitivity of DNA fragments can be improved from 20- to 100-fold relative to a normal injection (5 s). The electro-osmotic flow (EOF) and DNA-wall interactions within the capillary were eliminated effectively by dynamic coating method. Employing 0.5% poly(ethylene oxide) (PEO) in Tris-phosphate-EDTA (TBE) buffer as sieving matrix, DNA fragments, ranging from 11 to 657 bp, were separated within 20 min. The linear coefficient of linear relation between the migration and DNA length is 0.999. The DNA fragments amplified from transgenic oilseed rape by polymerase chain reaction (PCR) were separated and detected by this method, demonstrating the potential use of this method for effective DNA analysis and detection of genetically modified organisms (GMO).  相似文献   

14.
We developed a method for the analysis of multiplexed double-stranded DNA (dsDNA) samples complexed to various intercalating dyes using entangled polymer solution. A commercial single-column capillary electrophoresis (CE) instrument with diode array detection was used for multiplexed detection of DNA samples by addition of intercalating fluorescent molecules. A Phi X174HinfI and a pGEM DNA ladder (1 mg/mL) were used for the electrophoretic separation of dsDNA fragments ranging in size from 24 to 726 and 36 to 2645 bp, respectively. The results suggested that simultaneous electrophoretic separation of different DNA ladders multiplexed with different dyes could be performed in the same capillary yielding fast DNA sizing separations. CE analysis, which is often overpowered by slab gel in sample throughput, could now overcome this disadvantage by allowing multiplexed sample analysis in a fraction of the time needed for slab gel analysis. The separation efficiency of stained DNA molecules with both dyes were dramatically improved with buffers containing a large cation such as tetrapentylammonium ion (Npe(4) (+)) as the only cation in the buffer.  相似文献   

15.
Rapid separation of nucleic acids by microchip electrophoresis could streamline many biological applications, but conventional chip injection strategies offer limited sample stacking, and thus limited sensitivity of detection. We demonstrate the use of photopatterned polyacrylamide membranes in a glass microfluidic device, with or without fixed negative charges, for preconcentration of double-stranded DNA prior to electrophoretic separation to enhance detection limits. We compared performance of the two membrane formulations (neutral or negatively charged) as a function of DNA fragment size, preconcentration time, and preconcentration field strength, with the intent of optimizing preconcentration performance without degrading the subsequent electrophoretic separation. Little size-dependent bias was observed for either membrane formulation when concentrating dsDNA > 100 bp in length, while the negatively charged membrane more effectively blocks passage of single-stranded oligonucleotide DNA (20-mer ssDNA). Baseline resolution of a six-band dye-labeled ladder with fragments 100-2000 bp in size was obtained in <120 s of separation time, with peak efficiencies in the range of 2000-15,000 plates/cm, and detection limits as low as 1 pM per single dye-labeled fragment. The degree of preconcentration is tunable by at least 49-fold, although the efficiency of preconcentration was found to have diminishing returns at high field and/or long times. The neutral membrane was found to be more robust than the negatively charged membrane, with approximately 2.5-fold larger peak area during the subsequent separation, and less decrease in resolution upon increasing the preconcentration field strength.  相似文献   

16.
王前许旭  戴立信 《中国化学》2006,24(12):1766-1772
Quasi-interpenetrating network of polyacrylamide (PAA) and polyvinylpyrrolidone (PVP) had been successfully used for single-base resolution of double-stranded DNA (0.76 for 123 bp/124 bp) and single-stranded DNA fragments (0.97 for 123 b/124 b) with UV detection. This quasi-IPN (interpenetrating network) sieving matrix showed low viscosity (23.5 mPa·s at 25 ℃) and decreased with increasing temperature. This polymer also exhibited dynamically coating capacity and could be used in the uncoated capillary. The effects of temperature and electric field strength on the DNA separation of quasi-IPN matrix were also investigated and found that the temperature and electric field strength could markedly affected the mobility behavior of DNA fragments. This polymer matrix has also applied to separate the bigger DNA fragments by capillary electrophoresis with UV detection. Under the denaturing conditions, this matrix separated the samples with last fragment of 1353 base in 40 rain, in which the doublet of 309/310 base was partial separated and the resolution was 0.88.  相似文献   

17.
Zhang L  Dang F  Baba Y 《Electrophoresis》2002,23(14):2341-2346
The stepwise gradient of linear polymer matrices in microchannel electrophoresis is proposed as a means of achieving high-resolution separation of DNA samples containing a wide range of fragment sizes. In this method, multiple discrete steps in terms of polymer type or concentration are created in the microchannel by injecting appropriate solutions in order. The mixing of the various steps is found to be negligible compared to the effective length of separation channel, confirming that a stepwise gradient of matrices is formed. This technique is successfully applied to the analysis of restriction digest fragments and DNA ladders, and is demonstrated to provide higher resolution than the isocratic method, for both small and large fragments simultaneously. Even though the stepwise gradient is created manually, the reproducibility of the migration times of fragments in DNA samples is found to be quite good. Taken the separation of 100 bp DNA ladder in three steps gradient pattern as an example, the relative standard deviations of migration times are respectively less than 0.53% and 3.1% in six consecutive injections in one channel and in different channels. The migration of DNA fragments in gradient mode is shown to be similar to that for the isocratic scheme, allowing the design of each step to be made in reference to existing knowledge. These promising results indicate the great potential of this stepwise gradient method for the analysis of DNA by microchip electrophoresis, offering both high resolution and good reproducibility.  相似文献   

18.
Fu LM  Lin CH 《Electrophoresis》2004,25(21-22):3652-3659
An experimental and numerical investigation into the use of high-resolution injection techniques to separate DNA fragments within electrophoresis microchips is presented. The principal material transport mechanisms of electrokinetic migration, fluid flow, and diffusion are considered, and several variable-volume injection methods are discussed. A detailed analysis is provided of a double-L injection technique, which employs appropriate electrokinetic manipulations to reduce sample leakage within the microchip. The leakage effect in electroosmotic flow (EOF) is investigated using a sample composed of rhodamine B and Cy3 dye. Meanwhile, the effects of sample leakage in capillary electrophoresis (CE) separation are studied by considering the separation of 100-base pairs (bp) DNA ladders and HaeIII-digested PhiX-174 DNA samples. The present experimental and simulation results indicate that the unique injection system employed in the current microfluidic chip has the ability to replicate the functions of both the conventional cross-channel and the shift-channel injection systems. Furthermore, applying the double-L injection method to these two injection systems is shown to reduce sample leakage significantly. The proposed microfluidic chip and double-L injection technique developed in this study have an exciting potential for use in high-resolution, high-throughput biochemical analysis applications and in many other applications throughout the micrototal analysis systems field.  相似文献   

19.
The impact of hexadecyltrimethylammonium bromide (CTAB) on the separation of ds-DNA by capillary electrophoresis in conjunction with laser-induced fluorescence (CE-LIF) detection using poly(ethylene oxide) (PEO) solution is described. The use of CTAB for improved separation reproducibility and efficiency of DNA has not been demonstrated although it is widely used for controlling the magnitude and direction of electroosmotic flow in CE. With increasing CTAB concentration, the interactions of DNA with ethidium bromide (EtBr) and with the capillary wall decrease. For the separation of DNA fragments with the sizes ranging from several base pairs (bp) to 2,176 bp, a polymer solution consisting of 0.75% poly(ethylene oxide), 100 mM TB buffer (pH 8.0), 25 microg/mL EtBr, and 0.36 microg/mL CTAB is proper. Using the PEO solution, we separated a mixture of DNA markers V (pBR 322/HaeIII digest) and VI (pBR 328/BglI digest and pBR 328/HinfI digest) within 8 min at -375 V/cm, with the limit of detection of 2.0 ng/mL based on the peak height for the 18-bp DNA fragment. The method is highly efficient (>10(6)plate/m), repeatable (RSD of the migration times <1.5%), and sensitive. In addition, it is convenient to fill a capillary (75 microm in diameter) with such a low-viscosity PEO solution by syringe pushing.  相似文献   

20.
For the requirement of a high, fast and sufficient technology to suit the needs of 21st century biotechnology, the separation range of a microchip electrophoresis system was studied. Two DNA fragments on the human Y-chromosome, SY594 (82 bp) and 12f2 (88 bp), were successfully separated with a reproducibility of 1.9% and an accuracy of 2.8%. Then, a mixture of 10 DNA markers ranging from 61 bp to 189 bp was successfully separated with high resolution. All of these results demonstrate the superiority of microchip electrophoresis as a tool for 21st century bioseparation.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号