首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 359 毫秒
1.
BDE-209 is the predominant constituent of the commercial mixture decabromodiphenyl ether which is used as brominated flame retardant (BFR). Owing to difficulties associated with the high mass (thermal instability and low vapour pressure), short GC columns (≤15?m) have been suggested for its analysis while longer columns (30–50?m) are suggested for other polybrominated diphenyl ether (PBDE) congeners. To overcome this considerable expenditure in the analysis of PBDEs, we aimed at increasing the sensitivity of BDE-209 analysis by gas chromatography coupled with electron-capture negative ion mass spectrometry (GC/ECNI-MS) on a 30?m column. The chromatographic performance of BDE-209 on the 30?m GC column was improved by increasing the carrier gas flow from initially 1.2?mL?min?1 to 5 or 10?mL?min?1 after the last octabromo diphenyl ether (Br8DE) congener was eluted. With this high carrier gas flow, the column residence time of BDE-209 was shortened by ~25%, the peak height was increased and, consequently, the limit of detection by GC/ECNI-MS in selected ion monitoring (SIM) mode was improved. When this high-flow GC/ECNI-MS-SIM method was applied to a sediment sample, we realized that gel permeation chromatography (GPC) – used for the removal of lipids and/or sulphur – provided low recovery rates for BDE-209. The large molecule BDE-209 eluted late and only 50% was recovered by our previous standard protocol for polyhalogenated compounds. Application of a modified GPC procedure with a longer collection time increased the recovery of BDE-209 in the GPC step to ~90%.  相似文献   

2.
建立了食品中8种多溴联苯醚(PBDEs) 残留的气相色谱-串联质谱分析方法,初步解析了PBDEs的电子轰击串联质谱(EI MS/MS)图,为各种目标物的准确定性分析提供依据.以BDE-28、BDE-47、BDE-66、BDE-85、BDE-99、BDE-100、BDE-153、BDE-154为研究对象,对EI MS/MS各分析参数进行了优化.用超声提取-酸性硅胶层析柱净化的前处理方法制备样品,当空白样品的加标水平为10.0、25.0 μg/kg时,8种PBDEs的平均加标回收率为82% ~112%,相对标准偏差为3.1% ~15%,方法检出限均低于1.5 μg/kg;8种PBDEs的线性范围为10.0 ~500 μg/kg,相关系数均大于0.994 7.  相似文献   

3.
A large volume injection fast-GC-MS method has been developed, optimized and evaluated for the determination of polybrominated diphenyl ethers, including the decabrominated diphenyl ether (BDE-209). The programmed-temperature vaporiser injection parameters, temperature programming of the GC oven, and the physical dimensions of the narrow bore GC column were investigated to find the optimal operating conditions for the analysis. Depending on parameter settings the yield of the PBDEs and particularly BDE-209, varies significantly. Volumes up to 125 microl were successfully injected and a fast GC separation was performed, with retention times as short as 6.4 min for the last eluting compound, BDE-209. In a pilot study an air sample, collected at an electronics dismantling facility, was analyzed. Low-resolution mass spectrometry in electron capture negative ion mode was used for detection. Nine BDE congeners, including BDE-209, were identified and quantified.  相似文献   

4.
A rapid analytical method has been developed for the determination of polybrominated diphenyl ethers (PBDEs) in human hair. PBDEs were determined by gas chromatography with electron ionization mass spectrometric detection in the selected ion monitoring mode (GC-MS-SIM). A 200 mg amount of hair samples was overnight digested in 3N HCl and then PBDEs extracted with n-hexane. After clean up of extracts in a Florisil column, PBDEs were analyzed by GC-MS. The method has been validated by spiking human hair at five concentration levels, in the range from 5 to 25 ng/g for most compounds, and PBDEs were quantified using labelled compounds as internal standards. Recoveries of PBDEs were higher than 90%, repeatability was equal or lower than 12.5%, and reproducibility lower than 14%, expressed as relative standard deviation (RSD). Limits of detection (LOD) were in the range 0.08-0.9 ng/g and limits of quantification (LOQ) were between 0.27 and 3.0 ng/g. This method was applied to the determination of PBDEs in hair samples from 16 individuals and 5 PBDE congeners were detected in most of the samples. BDE-209 was the dominant compound found, followed by BDE-47, BDE-99, BDE-100, and BDE-190. BDE-209 was found in 12 out of 16 hair samples, and the total levels of PBDEs ranged from 1.4 to 19.9 ng/g.  相似文献   

5.
Xiao Z  Feng J  Shi Z  Li J  Zhao Y  Wu Y 《色谱》2011,29(12):1165-1172
建立了固相萃取同时提取、净化血清中四溴双酚A(TBBPA)、α, β, γ-六溴环十二烷(HBCD)和8种多溴联苯醚(PBDEs)同系物的样本前处理方法,并结合色谱-质谱分离分析技术检测人血清样本中该类化合物的含量。试样在加入各自的同位素内标物后以甲基叔丁基醚/正己烷(1:1, v/v)混合溶剂进行萃取,再经浓硫酸去除脂肪后,以LC-Si固相萃取柱分离HBCD/TBBPA和PBDEs。采用分步检测的方式,在50 mm长BEH C18反相色谱柱上以超高效液相色谱-串联质谱(UPLC-MS/MS)的多反应监测模式(MRM)检测HBCD和TBBPA,在15 m长的毛细管柱上以气相色谱-负化学源质谱(GC-NCI/MS)的选择离子监测模式(SIM)检测PBDEs。以胎牛血清为空白基质,当HBCD、TBBPA和BDE-209的加标水平为0.5 ng/g和5 ng/g、三溴至七溴联苯醚的加标水平为0.05 ng/g和0.5 ng/g时,它们的平均加标回收率为80.3%~108.8%,相对标准偏差为1.02%~11.42%(n=5);以信噪比(S/N)为3计算,方法的检出限(LOD)为1.81~42.16 pg/g。采用该方法对实际样品进行测定,结果表明,本方法快速、准确、灵敏度高,能够满足血清中HBCD、TBBPA和PBDEs残留的同时提取及测定的要求。  相似文献   

6.
将超声辅助碱液分解杂质与溶剂萃取相结合,采用气相色谱-电子捕获检测(GC-ECD)建立了一种快速高效净化、萃取海洋沉积物中8种常见多溴联苯醚(PBDEs)的分析方法。样品在2.00 mol/L NaOH甲醇溶液中超声30 min,经正己烷萃取、单层硅胶净化、正己烷洗脱、旋蒸浓缩后定容至100 μL,采用GC-ECD分析。结果表明,PBDEs各单体的加标回收率为63.6%~110.3%,相对标准偏差(RSD)为1.7%~15.5%(n=5);十溴联苯醚(BDE-209)的检出限为0.097 ng/g,其他7种单体的检出限为0.002~0.011 ng/g(信噪比为3)。该方法的准确度和精密度较高,稳定性和回收率良好,可满足沉积物中PBDEs的分析要求。利用建立的方法测定了渤海表层沉积物中PBDEs的含量,8种PBDEs总含量在1.566~6.760 ng/g之间,其中BDE-209的含量为1.461~6.438 ng/g,总体呈现出由近岸向远岸递减的趋势,表明人为活动、表层冲刷和陆地河流的输入对渤海地区PBDEs的含量有重要影响。  相似文献   

7.
This paper reports the applicability of low-pressure gas chromatography-mass spectrometry operated in electron-capture negative ionization mode (LP-GC-ECNI-MS) for the analysis of decabrominated diphenyl ether (BDE-209). Particular attention was paid to find optimal injector and oven conditions for minimal thermal degradation of BDE-209. The analytical characteristics were compared for LP-GC columns (10 m x 0.53 mm) with different film thicknesses (d(f) 0.15 microm versus 0.25microm) and for a conventional GC column (15 m x 0.25 mm, 0.10 microm d(f)). Short residence times (6.5 and 9.8 min) of BDE-209 were found for the LP-GC systems with 0.15 and 0.25microm d(f), respectively, resulting in a low elution temperature and minimal degradation. Additionally, baseline separation of 22 polybrominated diphenyl ether (PBDE) congeners (major components of PBDE technical mixtures) was possible in less than 12 min using the LP-GC-ECNI-MS system with 0.15microm d(f). The optimized method was applied for the determination of PBDEs in Belgian indoor dust samples. The obtained concentrations of BDE-209 (range 8-292 ng/g dry weight) were in the same range or lower than concentrations in dust from other European countries.  相似文献   

8.
An analytical method for higher brominated congeners of polybrominated diphenyl ethers (PBDEs) was optimised using a gas chromatograph equipped with an electron impact ionisation-quadrupole mass spectrometer (GC-EI-qMS) and five native PBDEs and three 13C12-labelled congeners in biological and environmental samples (mussels, sediment, dust). In the optimised instrumental conditions, abundance and repeatability improved with increase in temperature of the ion source. The instrumental detection limits (IDLs) for BDE-196, BDE-197, BDE-206, BDE-207 and BDE-209 were 0.1, 0.1, 0.2, 0.3 and 0.6?pg, respectively. When compared to the previous reports, the IDLs were the same as for electron capture negative ionisation (ECNI) or EI-double focusing magnetic sector (EI-Sector) mass spectrometer, indicating that sensitive determination could be achieved using a conventional GC-EI-qMS. Validation of the method was carried out by the analysis of reference materials and mussel samples. We confirmed that the concentrations quantified using this method was in the range of reported values for reference materials. Similar concentrations were found in mussels, which were analysed previously by our group. Thus, we conclude that a conventional GC-EI-qMS can be applied for analysis of higher brominated PBDEs in various environmental and biota matrices.  相似文献   

9.
超声辅助萃取气相色谱-质谱法测定松针中的多溴联苯醚   总被引:3,自引:0,他引:3  
陈长二  赵洪霞  谢晴  陈景文 《色谱》2009,27(1):59-62
建立了测定松针样品中多溴联苯醚(PBDEs)的分析方法。松针样品经过正己烷-丙酮(体积比为1∶1)混合溶液超声萃取、浓硫酸和氧化铝柱净化后,采用气相色谱-负化学电离源质谱(GC-NCI-MS)选择离子监测(SIM)模式检测,内标法定量。结果表明,方法的加标回收率为83.8%~107.5%,三溴~七溴代联苯醚的仪器检出限为0.152~ 0.770 pg,十溴代联苯醚(BDE-209)的检出限为11.1 pg;三溴~七溴代联苯醚的方法检出限(湿重)为3~15 pg/g,BDE-209的方法检出限(湿重)为222 pg/g。方法具有良好的重现性、较高的灵敏度和良好的回收率。实际样品分析表明,松针中BDE-209是主要的同类物,约占8种PBDEs总量的82.3%,低溴代联苯醚以2,2′,4,4′-四溴联苯醚(BDE-47)为主。  相似文献   

10.
王梦梦  谢琳娜  朱英  陆一夫 《色谱》2022,40(4):354-363
建立了同位素内标-气相色谱-高分辨双聚焦磁质谱(GC-HRMS)同时测定人体血清中14种多溴联苯醚(PBDEs)的方法.血清样品解冻后,取0.5 mL与13 C标记的内标物进行混合,加入甲醇沉淀样品中的蛋白质,比较了3种酸化条件下的去脂效果和回收率,结果显示硫酸去脂效果最好;使用液液萃取法提取样品中的目标物,比较了不同...  相似文献   

11.
Atmospheric pressure photoionization (APPI) was assessed for the mass spectrometric analysis of polybromodiphenyl ethers (PBDEs) on the basis of a set of 17 standard compounds. Positive and negative ionization modes were both investigated. M(+.) ions were formed under positive ion conditions whereas the negative ion mode yielded [M-Br+O](-) ions. The behavior of these APPI-produced ions towards collisional activation was studied using an ion trap mass spectrometer. In positive ion mode, the loss of Br(2) was one of the major fragmentation pathways, and was favored for ortho-substituted PBDEs. Conversely, the loss of COBr(.) occurred only for non-ortho-substituted congeners. The collisional excitation of [M-Br+O](-) ions in the ion trap also led to the loss of Br(2), to the elimination of HBr, and to the formation of product ions by cleavage of the ether bond. The formation of para-quinone radical anions was observed for PBDEs ranging from penta- to hepta-congeners, whereas brominated aromatic carbanions were formed preferentially for the most brominated PBDEs studied in this work (hepta- or deca-BDEs). M(+.) ions did not undergo this fragmentation process.  相似文献   

12.
To improve the insulating properties of polybrominated diphenyl ethers(PBDEs), we studied the molecular structures and energy gap(Eg) values of 209 PBDEs using a three-dimensional quantitative structure-activity relationship(3D-QSAR) model, molecular docking, and molecular dynamics. We also analyzed the interaction mechanisms of PBDEs using a 2D-QSAR model, molecular substitution characteristics, and molecular docking. The 3D-QSAR model showed that the 2-, 4-, 5-, and 6-positions significantly influenced the PBDE insulating properties. Using BDE-34 as a template molecule, we designed six derivatives with 0.47%-28.44% higher insulation tlian BDE-34. Compared with BDE-34, the stability and flame retardancy of the above six derivatives were not adversely affected. These derivatives, except for 2,6-cyanomethyl-BDE, 2-cyanomethyl-BDE, and 2-aniinomethyl-BDE, were more toxic and biodegradable than BDE-34, but showed weaker bioaccumulation and migration abilities than BDE-34. Mechanism analysis showed that the highest occupied orbital energy, the most negative charge, and the dipole moment were the main quantitative parameters that aflected the PBDE insulating properties. PBDE insulation gradually decreased as the number of Br atoms increased. The level of similarity between the substitution patterns on the two benzene rings was significantly correlated with PBDE insulation, with hydrophobic groups having a more significant efiect on PBDE insulation.  相似文献   

13.
Eight polybrominated diphenyl ether (PBDE) congeners of primary interest to the US EPA were separated using reverse-phase liquid chromatography on an octadecylsilane column. BDE-28, BDE-47, BDE-99, BDE-100, BDE-153, BDE-154, BDE-183, and BDE-209 were baseline-resolved under isocratic conditions in 92:8 methanol/water (v/v). Negative-ion atmospheric pressure photoionization (NI-APPI) with a toluene dopant produced precursor ions corresponding to [M–Br+O] for the eight congeners studied. Each congener was quantified by tandem mass spectrometry through a unique multiple reaction monitoring (MRM) transition. On-column limits of detection were between 2.4 and 27.8 pg for the eight congeners studied, with an intra-day method precision of 9%. The LC/NI-APPI/MS/MS method was validated for the analysis of the eight PBDE congeners in NIST SRM 2585 (Organics in House Dust). Pressurized liquid extraction (PLE) with subsequent LC/NI-APPI/MS/MS analysis afforded quantitative recovery for all eight PBDE congeners with recoveries ranging from 92.7 to 113%. The liquid-phase separation of the LC/NI-APPI/MS/MS method is not prone to the thermal degradation issues that plague splitless GC based analyses of highly brominated PBDEs such as BDE-209.  相似文献   

14.
建立了气相色谱-质谱法(GC-MS)分析土壤中的18种多溴联苯(PBBs)和多溴联苯醚类(PBDEs)化合物的方法.利用快速溶剂萃取(ASE)技术和凝胶净化系统(GPC)进行土壤样品的前处理,(13)C标记物作为进样内标和替代标,采用电子轰击源气相色谱质谱法(GC-EI/MS )分析-溴至七溴代PBBs和PBDEs,负...  相似文献   

15.
鱼肉组织中多溴联苯醚的定量分析   总被引:9,自引:0,他引:9  
多溴联苯醚(PBDEs)是一类广泛用于家用电器、电子产品、塑料泡沫、家居装饰材料等行业的添加型阻燃剂[1],使用量最多的是五溴联苯醚(penta-BDE),八溴联苯醚(octa-BDE)和十溴联苯醚(deca-BDE)3种[2]。最近的研究表明[4-6],多溴联苯醚已广泛地存在于各种环境介质、生物体及人体中  相似文献   

16.
Methods for environmental analysis of higher brominated diphenyl ethers (PBDEs), in particular decabromodiphenyl ether (BDE209), and the recently discovered environmental contaminant decabromodiphenyl ethane (deBDethane) are reviewed. The extensive literature on analysis of BDE209 has identified several critical issues, including contamination of the sample, degradation of the analyte during sample preparation and GC analysis, and the selection of appropriate detection methods and surrogate standards. The limited experience with the analysis of deBDethane suggests that there are many commonalities with BDE209. The experience garnered from the analysis of BDE209 over the last 15 years will greatly facilitate progress in the analysis of deBDethane.  相似文献   

17.
Huang F  Zhao Y  Li J  Wu Y 《色谱》2011,29(8):743-749
采用OasisHLB固相萃取柱萃取血清中的多溴联苯醚(PBDEs),经浓硫酸柱上除脂后,利用气相色谱-负化学源质谱法测定BDE-17、28、47、66、99、100、153、154、183和209共10种PBDEs组分。BDE-209的测定采用DB-5 ms色谱柱(15 m×0.25 mm×0.1 μm),其他组分采用VF-5 ms色谱柱(30 m×0.25 mm×0.25 μm)。对样品中蛋白质的去除溶剂和固相萃取条件(如洗脱溶剂及其用量)进行了优化。胎牛血清中的加标回收试验结果显示,各PBDEs单体相对于内标的平均回收率为78.5%~109.7%,日内测定的相对标准偏差(RSD)为0.3%~7.4%,日间测定的RSD为1.4%~14.1%。胎牛血清中三溴~七溴联苯醚的检出限(信噪比为3)为0.10~0.27 ng/L;定量限(信噪比为10)除了BDE-209为7.91 ng/L外,其他PBDEs为0.35~0.91 ng/L。采用本方法测定标准参考物质SRM1957和SRM1958,结果在参考值范围内。实验结果表明,本方法灵敏度高、准确度和精密度好,简便快速,溶剂消耗量少,适用于人体血清中三至十位溴取代联苯醚的测定。  相似文献   

18.
A method for the determination of 14 polybrominated diphenyl ethers (PBDEs) in sludge from wastewater treatment plants is presented. PBDEs were extracted by matrix solid‐phase dispersion assisted by sonication and determined by isotope dilution gas chromatography with electron impact mass spectrometric detection in the selected ion monitoring mode, using labelled 13C‐PBDEs as internal standards. The limits of detection and quantification for the tri‐ to hepta‐BDEs were in the range of 0.05 to 0.5 ng/g dry weight and 0.15 to 1.8 ng/g dry weight, respectively, and 1.6 ng/g dry weight and 5.6 ng/g dry weight for deca‐BDE‐209. The proposed analytical method was applied to determine PBDE levels in sewage sludge samples collected from 19 water treatment plants located in the province of Madrid (Spain). In all of the examined samples, BDE‐100 and BDE‐154 were the main compounds found with a mean concentration of 3.9 and 2.0 ng/g, respectively. PBDEs were detected in all of the samples, and their total concentrations not considering BDE‐209 were between 3.9 and 23.0 ng/g dry weight. The dominant PBDE congener in sewage sludge was BDE‐209, which constituted 38.7 to 97.3% of the total, and showed concentration levels ranging from 8.1 to 717.2 ng/g dry weight.  相似文献   

19.
Analysis of 11 polybrominated diphenyl ethers (PBDEs), tetrabromobisphenol A bis 2,3-dibromopropylether (TBBPA-bis), tetrachlorobisphenol A (TCBPA), tetrabromobisphenol A (TBBPA) and hexabromocyclododecanes (HBCDs) was optimized by ultrahigh pressure liquid chromatography/tandem mass spectrometry (UPLC–MS/MS) operating in negative ion (NI) mode. Electrospray ionization (ESI), atmospheric pressure photoionization (APPI) and atmospheric pressure chemical ionization (APCI) sources were tested and for PBDEs APCI gave higher sensitivity than APPI while for TBBPA-bis APCI and APPI showed similar performance. ESI was the best option for TCBPA, TBBPA and HBCDs. Detection limits were between 20 and 59 fg for the compounds analyzed by ESI, 0.10 and 0.72 pg for PBDEs and 6 pg for TBBPA-bis. The matrix effect of sewage sludge extract was also tested showing negligible ion suppression for APCI and an increase of the background level of all investigated pollutants leading to a worsening of the limits of quantification by a factor between 1.2 and 3.3. The UPLC-APCI/MS/MS method for PBDEs, after pressurized liquid extraction (PLE), was validated by comparison with the concentration values from the NIST 1944 standard reference material. The advantages of the methods include low detection limits, PBDE congeners specificity using selected multiple reaction monitoring (MRM) transitions, and the absence of thermal degradation of higher PBDE congeners, especially BDE-209. The methods were applied for the determination of the above reported flame retardants in sewage sludge in order to get more information about the degradation on PBDEs (in particular BDE-209) during municipal wastewater treatments.  相似文献   

20.
Li Y  Hu J  Liu X  Fu L  Zhang X  Wang X 《Journal of separation science》2008,31(13):2371-2376
A simple, rapid, and efficient method, dispersive liquid-liquid microextraction (DLLME), has been developed for the extraction and preconcentration of decabrominated diphenyl ether (BDE-209) in environmental water samples. The factors relevant to the microextraction efficiency, such as the kind and volume of extraction and dispersive solvent, the extraction time, and the salt effect, were optimized. Under the optimum conditions (extraction solvent: tetrachloroethane, volume, 22.0 microL; dispersive solvent: THF, volume, 1.00 mL; extraction time: below 5 s and without salt addition), the most time-consuming step is the centrifugation of the sample solution in the extraction procedure, which is about 2 min. In this method, the enrichment factor could be as high as 153 in 5.00 mL water sample, and the linear range, correlation coefficient (r(2)), detection limit (S/N = 3), and precision (RSD, n = 6) were 0.001-0.5 microg/mL, 0.9999, 0.2 ng/mL, and 2.1%, respectively. This method was successfully applied to the extraction of BDE-209 from tap, East Lake, and Yangtse River water samples; the relative recoveries were 95.8, 92.9, and 89.9% and the RSD% (n = 3) were 1.9, 2.7, and 3.5%, respectively. Comparison of this method with other methods, such as solid-phase microextraction (SPME), and single-drop microextraction (SDME), indicates that DLLME is a simple, fast, and low-cost method for the determination of BDE-209, and thus has tremendous potential in polybrominated diphenyl ethers (PBDEs) residual analysis in environmental water samples.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号