首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
In this paper, a heuristic approach based on Slavic's peak searching method has been employed to estimate the width of peak regions for background removing. Synthetic and experimental data are used to test this method. With the estimated peak regions using the proposed method in the whole spectrum, we find it is simple and effective enough to be used together with the Statistics-sensitive Nonlinear Iterative Peak-Clipping method.  相似文献   

2.
在中子检测爆炸物的研究中,利用14 MeV中子与原子序数大于5的原子核相互作用可产生特征射线的特性,采用伴随粒子法结合D-T中子飞行时间技术,使用尺寸为12.5 cm20 cm的大体积NaI(Tl)探测器,对爆炸物所含元素C,N,O以及一些模拟炸药样品进行了瞬发谱测量。获得了几种典型样品的特征谱,并对其进行了分析。实验结果与欧盟同期结果进行了比较,表明本实验研究达到了目前国际同类实验的水平,可以为中子检测爆炸物识别技术提供实验支持。  相似文献   

3.
The spectral distributions of external bremsstrahlung (EB) excited by beta particles from a 90Sr/90Y source in thick target compounds PbCl2, PbF2, Pb(NO3)2 and CdO were measured using a 3.8 cm × 3.8 cm NaI(Tl) crystal. The spectra, unfolded using the Liden-Starfelt procedure, showed fairly good agreement with theory (Tseng and Pratt) at low energies and some deviation (less than 15%) at higher energies. The discrepancy between theory and experiment increases with modified atomic number of the target compound and photon energy. The application of the measured/theoretical spectrum to estimate the bremsstrahlung dose is also discussed.  相似文献   

4.
The unfolding of neutron spectra from the pulse height distribution measured by a BC501A scintillation detector is accomplished by the application of artificial neural networks (ANN). A simple linear neural network without biases and hidden layers is adopted. A set of monoenergetic detector response functions in the energy range from 0.25 MeV to 16 MeV with an energy interval of 0.25 MeV are generated by the Monte Carlo code O5S in the training phase of the unfolding process. The capability of ANN was demon...  相似文献   

5.
6.
The variation in environmental scattering background is a major source of systematic errors in X-ray inspection and measurement systems.As the energy of these photons consisting of environmental scattering background is much lower generally,the Cerenkov detectors having the detection threshold are likely insensitive to them and able to exclude their influence.A thickness measurement experiment is designed to verify the idea by employing a Cerenkov detector and an ionizing chamber for comparison.Furthermore,it is also found that the application of the Cerenkov detectors is helpful to exclude another systematic error from the variation of low energy components in the spectrum incident on the detector volume.  相似文献   

7.
The variation in environmental scattering background is a major source of systematic errors in X- ray inspection and measurement systems. As the energy of these photons consisting of environmental scattering background is much lower generally, the Cerenkov detectors having the detection threshold are likely insensitive to them and able to exclude their influence. A thickness measurement experiment is designed to verify the idea by employing a Cerenkov detector and an ionizing chamber for comparison. Furthermore, it is also found that the application of the Cerenkov detectors is helpful to exclude another systematic error from the variation of low energy components in the spectrum incident on the detector volume.  相似文献   

8.
The aims of our work were: i) to measure selected normalized X-ray beam spectra with the commercially available cadmium telluride detector based spectrometry system; ii) to construct the approximate response matrix of the detector using a simple algebraic model approach; iii) to reconstruct the physical energy spectra from the measured instrumental spectra using the detector response matrix; iv) to compare the obtained spectra parameters with the published and reference data in order to verify the model and to optimize the measurement setup if necessary. In particular, the spectra of five “narrow-spectrum series” beams, namely N60 to N150, were measured with a spectrometry system consisting of the Amptek XR-100T X-ray semiconductor detector and the PX5 multichannel analyser. Two different measuring geometries were used. The response matrix R(E, E′) of the detector was constructed which quantifies the energy dependence of the relative detection efficiency of the detector, the probabilities of the escape effects, and the probability of the Compton effect. A single matrix operation was applied to recover the physical energy spectra from the measured instrumental ones. The parameters of the corrected spectra were compared with the published and reference data. Despite the fact that the effect of incomplete charge collection was not implemented in the detector model, a fully satisfying quantitative correspondence was observed between the measured corrected spectra and the available reference data.  相似文献   

9.
介绍了由K壳层谱线强度比估算等离子体状态参数的"碰撞-辐射"模型的基本原理.详细描述了自行研制的基于该模型的Z箍缩等离子体K壳层线辐射谱分析程序——ZSPEC的基本情况.给出了氖等离子体的计算结果,包括不同电离态离子的相对含量随电子温度的变化曲线和K壳层谱线强度比在"电子密度-电子温度"平面内的等高线分布图.该程序已在"阳"加速器Z箍缩实验结果分析中得到应用,将椭圆晶体谱仪测得的氖等离子体K壳层谱线强度比与ZSPEC程序计算结果相比较,得出在该发实验 关键词: 碰撞-辐射模型 K壳层线辐射谱')" href="#">K壳层线辐射谱 氖气喷气Z箍缩 阳加速器  相似文献   

10.
李鹏  章新华  付留芳  曾祥旭 《物理学报》2017,66(8):84301-084301
水面水下目标分辨与识别一直是被动声呐探测领域的难题.利用一种水平阵模态域波束形成算法获得己知方位目标声源的各阶模态强度,将其与不同深度的各阶参考模态强度进行匹配,最终实现了对声源的深度估计.仿真结果表明,该算法可以在信噪比为-10 dB的情况下,用300Hz带宽的信号样本,实现对声源深度的有效估计.系统分析了不同参数和不同波导条件对该方法目标深度估计性能的影响.其中,阵元数越多,模态样本数越多,计算频段越宽,方位估计精度越高,有效阵长越长,深度估计的性能越好.阵元间距和波导深度的变化不会影响该方法的深度估计性能,并且该方法的深度估计性能在声速剖面、海底参数等波导条件存在扰动时具有鲁棒性.  相似文献   

11.
12.
There is a lack of extensive data comprising energy spectra of therapeutic beams used in teleradiotherapy, generated by medical linear accelerators. In particular there is a lack of the data for energy spectra in water. However, the spectra in water differ from those in air significantly because of strong photon scattering processes. The aim of this paper was the presentation of the wide range of detailed data for the 6 MV X-ray therapeutic beams from a medical linear accelerator Clinac-2300 by Varian. The presented data were derived by the use of Monte Carlo computer simulations (GEANT4 code). The performed investigations indicate that shapes of the spectra, total number of photon registered in a bin as well as mean energy of the considered beam depend on a depth in water, on a distance from the central-axis of the beam and on a radiation field size. However, shapes of the spectra as well as the beam mean energy does not depend on a bin size, independently of a depth in water and a radiation field whereas total number of photon registered in a bin is related to a bin size. Majority of the presented results were obtained for a cylindrical 1.41 cm3 bin with the radius of 1.5 cm. The obtained data are very useful for the accurate absorbed depth-dose determination particularly outside the reference conditions, for advanced treatment planning systems, for constructors of medical accelerators etc.  相似文献   

13.
J N Das  A Dey  K Chakrabarti 《Pramana》1995,45(1):41-46
Schwinger variational principle has been used to calculate triple differential cross-sections for ionization of hydrogen atoms by positrons at intermediate and high energies for Ehrhardt type asymmetric geometry. The results agree in general with the calculations of Brauneret al [8] and with the second Born calculation.  相似文献   

14.
Evidential values of Raman spectra recorded for solid and metallic blue car paints were evaluated using visual comparison as well as a statistical approach, i.e. likelihood ratio (LR) test supported by Empirical Cross Entropy (ECE) results. Raman spectra were obtained using a Renishaw inVia spectrometer equipped with a confocal Leica microscope and a near infrared semiconductor laser (785 nm) as an excitation source. When a visual comparison was performed for solid paints, in 17.7% of comparisons (53 pairs out of 300) the samples were indistinguishable, whereas for metallic paints this value was 8.5% of such comparisons (37 pairs out of 435). Comparing the spectra using an LR approach was based on variables being the areas under the most significant Raman spectra bands of pigments present in the analysed samples. Proposed LR models delivered low false positive and false negative rates (for many models lower than 10%), and the ECE plots confirmed that their performance was much better than visual comparison. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

15.
Using a high-resolution tunable diode laser photoacoustic spectrometer, self-, N2 and O2 pressure broadening coefficients for the first 11 transitions of 12C16O2 in the R branch of the (30012) ← (00001) overtone band at the 6348 cm−1 have been revisited at room temperature (∼298 K). Air-broadening parameters have also been calculated from the N2 and O2 measurements. The dependence of the broadening on rotational quantum number m is discussed. The recorded lineshapes are fitted with standard Voigt line profiles in order to determine the collisional broadening coefficients of carbon dioxide transitions. The results are compared to our previous measurements and to the values reported in the HITRAN04 database and by other research group with a different spectroscopic technique.  相似文献   

16.
P. Arulmozhivarman 《Optik》2006,117(2):82-87
A wavelet-based method of moment calculation with a set of basis functions is presented for centroid estimation in a Shack-Hartmann Wavefront Sensor. The method has been compared with other algorithms such as statistical averaging, FFT and least-squares method. A comparative analysis shows that wavelet method has a high accuracy and processing speed, and better suited for wavefront reconstruction applications. Further, the wavelet method presented here has a variable accuracy and resolution, and can be optimized for a particular application under consideration.  相似文献   

17.
A simple theoretical method is introduced for studying the interrelation between electronic and molecular structures.By diagonalizing the 120 × 120 complete energy matrices,the relationships between zero-field splitting(ZFS) parameter D and local distortion parameter △θ for Cr 3+ ions doped,separately,in α-and β-alums are investigated.Our results indicate that there exists an approximately linear relationship between D and △θ in a temperature range 4.2-297 K and the signs of D and △θ are opposite to each other.Moreover,in order to understand the contribution of spin-orbit coupling coefficient ζ to ZFS parameter D,the relation between D and ζ is also discussed.  相似文献   

18.
The curvilinear coordinate method is an efficient theoretical tool for analysing rough surfaces. It consists on solving Maxwell’s equations written in a nonorthogonal coordinate system. The C method leads to eigenvalue systems and the scattered fields can be expanded as a linear combination of eigensolutions. The boundary conditions allow the combination coefficients to be determined. The dominant computational cost for the C method is the eigenvalue problem solution which is of order of N3 where N is the size of eigenvalue systems. In this paper, we propose a new approach based on the association of the C method with the beam simulation method (BSM) in order to reduce the computational time. The BSM is based on decomposing a large incident beam into narrower subbeams and then synthesizing the large beam by coherent superposition. The adopted procedure consists of two stages. First, the surface fields are obtained by the C method associated with each elementary beam illuminating smaller surfaces. Second, the total surface field is deduced from a coherent superposition of elementary surface current densities. The far-field and the scattering coefficients are derived from the Huygens principle applied to the total surface fields. We confirm the efficiency and the validity of the approach and show that the BSM applied with the C method allows a significant saving in computation time.  相似文献   

19.
In this paper, the relationships between the optical spectra and local lattice structure for Mn5+ in a Sr10(VO4)6F2 crystal are established by the crystal- and ligand-field theory. The effect of spin–orbital coupling between the central 3d2 ions and ligand ions has been considered in the full energy matrix. Using the matrix and superposition model formula, we have calculated the optical spectra and local lattice structure parameters of Mn5+ in Sr10(VO4)6F2 with a C3v system. The calculated results are in good agreement with the observed values. In addition, the trigonal compressed distortions of the (MnO4)3? centers in Sr10(VO4)6F2 crystals are also obtained from the calculations.  相似文献   

20.
We analyze the time evolution of mixed state ρ0 in a dissipative channel, characteristic of a decay constant κ, by virtue of the elegant properties of entangled state representation 〈η|. We find that the matrix element of the mixed state ρ(t) at time t in 〈η| representation is proportional to that of the initial ρ0 in the decayed entangled state 〈ηe-κt| representation, accompanying with a Gaussian damping factor . Thus we have a new insight about the nature of the dissipative process.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号