首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
An on-line flow injection preconcentration-ETAAS method is developed for trace determination of cobalt in biological materials and natural samples by ion-pair sorption on the inner walls of a PTFE knotted reactor. The ion-pair is formed between the negatively charged cobalt-nitroso-R-salt complex and the tetrabutylammonium counter-ion. An enhancement factor of 15, a sampling frequency of 17 and a concentration efficiency of 4 are obtained for a preconcentration time of 60 s and a sample loading flow rate of 5 mL min–1. The detection limit (3σ) is 5 ng L–1. The relative standard deviation at the 0.2 μg L–1 level is 2.3%. The analytical results obtained for standard reference materials are in good agreement with the certified or indicated values and satisfactory recoveries of spiked cobalt in tap water are obtained.  相似文献   

2.
A novel method for cobalt preconcentration by cloud point extraction with on-line phase separation in a PTFE knotted reactor and further determination by electrothermal atomic absorption spectrometry (ETAAS) is proposed. The cloud point system was formed in the presence of non-ionic micelles of polyethyleneglycolmono-p-nonylphenylether (PONPE 7.5) and it was retained on the inner walls of a knotted reactor (KR). The surfactant rich-phase was removed from the knotted reactor with 75 microL of methanol acidified with 0.8 mol L(-1) nitric acid, directly into the dosing hole of the L'Vov graphite tube. An enrichment factor of 15 was obtained with a preconcentration time of 60 s, with respect to the direct determination of cobalt by ETAAS in aqueous solutions. The value of the detection limit for the preconcentration of 5 mL of sample solution was 10 ng L(-1). The precision, expressed as the relative standard deviation (R.S.D.), for 10 replicate determinations at 0.5 microg L(-1) Co level was 4.5%. Verification of the accuracy was carried out by analysis of a standard reference material (NIST SRM 1640e "Trace elements in natural water"). The method was successfully applied to the determination of cobalt in drinking water samples.  相似文献   

3.
Matos GD  Arruda MA 《Talanta》2008,76(2):475-478
An on-line derivatization strategy was developed for improving cobalt sensitivity using thermospray flame furnace atomic absorption spectrometry (TS-FF-AAS) as the analytical technique. This strategy involves the generation of a volatile cobalt compound, providing better sample vaporization efficiency. The effect of sodium diethyldithiocarbamate (DDTC) as complexing agent on the integrated absorbance signal was evaluated. Parameters including the pH of complex formation, complex concentration and volume, sample volume, flame gas composition and tube atomization configuration were optimized. A wide linear range (from 23 microg L(-1) to 3 mg L(-1); r(2)=0.9786) was obtained, with the best one (r(2)=0.9992) attained from 23 to 400 microg L(-1) with a sample throughput of 30 h(-1). The improvement in the detection power was 17-fold when compared to FAAS, which provides 7 microg L(-1) as the limit of detection when considered TS-FF-AAS technique. A relative standard deviation (n=10) of 4% for a cobalt solution containing 50 microg L(-1) was attained, and the accuracy of the procedure was evaluated through certified reference materials (IAEA-SL-1, lake sediment; and ISS-MURST-A1, Antarctic marine sediment). Good agreement between the results at the 95% confidence level was observed.  相似文献   

4.
S Taguchi  K Takahashi  N Hata  I Kasahara 《The Analyst》2001,126(11):2078-2081
Anionic surfactants containing sulfur in their structure were enriched on a mixed cellulose ester membrane filter (MF) by filtration as an ion-pair complex with a cationic surfactant. After their enrichment, the anionic surfactants were determined by X-ray fluorescence spectrometry of the sulfur enriched on the MF. A linear calibration was obtained over a concentration range from 0.05 to 0.8 mg L(-1) of sodium dodecyl sulfate as a standard material with less than 6% RSD. The detection limit based on 3s for the reagent blank was 2 microg L(-1). This method is very simple, rapid and highly selective for sulfur-containing surfactants, and does not require any organic solvent extraction. This method was applied to the determination of anionic surfactant in some urban river waters where domestic wastewater was discharged. The results were compared with those obtained by conventional solvent extraction-spectrophotometry. The distribution of the analyte complexes within the MF where the ion-pair was retained is also discussed.  相似文献   

5.
程晓昆  王娅莉  张惠敏  牛长群 《色谱》2012,30(12):1292-1294
建立了反相离子对色谱法分离测定脱氧精胍菌素药物中主成分的方法。分别考察了色谱柱类型、离子对试剂种类及浓度、缓冲盐浓度和流动相pH值等参数对实验结果的影响。确定了分离脱氧精胍菌素的最佳条件: C18色谱柱(250 mm×4.6 mm, 5 μm);以5 mmol/L磷酸氢二钾水溶液(含5 mmol/L戊烷磺酸钠,pH 3.6±0.3)-乙腈(90:10, v/v)为流动相,流速为1.0 mL/min;检测波长为210 nm;柱温为30 ℃;进样量为20 μL。该方法实现了对脱氧精胍菌素的良好分离,且线性关系良好,检出限可达0.5 mg/L。  相似文献   

6.
2-(2-Quinolinylazo)-5-dimethylaminobenzoic acid (QADMAB) is proposed as a new sensitive and selective chromogenic reagent for spectrophotometric determination of cobalt. The QADMAB reacts with cobalt in the presence of cetyl trimethylammonium bromide (CTMAB) medium to form a violet complex of molar ratio 1:2 (cobalt to QADMAB) in the pH range 3.2-5.2. The molar absorptivity of the complex is 1.28x10(5) L mol(-1) cm(-1) at 625 nm. Beer's law is obeyed in range 0.01-0.32 micro g mL(-1). The relative standard deviation for eleven replicate samples of 0.2 micro g mL(-1) is 0.76%. This method was applied to the determination of cobalt in biological samples, Vitamin B(12), alloys and water with good results.  相似文献   

7.
A method was developed for the generation of a "cold vapor" of cadmium by means of flow injection-chemical vapor generation from aqueous samples, the determination being conducted with an atomic absorption spectrometer (Pyrex glass T-cell). Several gas-liquid separator designs, atomizer designs, and the effect of several reagents previously reported as sensitivity enhancers (including cobalt, nickel, thiourea and didodecyl-dimethylammonium bromide) were investigated. The limit of detection, calculated as the concentration giving a signal equal to three times the standard deviation of the blank, was 16 ng L(-1), and the relative standard deviation was 1.4% for a concentration of 2 microg L(-1) and 3.8% for 0.1 microg L(-1). The addition of nickel and thiourea to the samples provided improved tolerance to the interference of coexisting ions. Two NIST certified reference materials, Montana Soil and Apple Leaves (respectively containing 41.7+/-0.25 mg kg(-1) Cd and 0.013+/-0.002 mg kg(-1) Cd) were accurately analyzed. The interference of lead was overcome by coprecipitation with barium sulfate, and the experimental values obtained were 41+/-1 mg kg(-1) Cd and 0.013+/-0.002 mg kg(-1) Cd, respectively.  相似文献   

8.
建立了反相离子对色谱-直接电导检测六氟磷酸根(PF6-)离子液体阴离子的分析方法。用DiamonsilC18反相色谱柱为分离柱,以离子对试剂-柠檬酸-乙腈混合水溶液为流动相,考察了离子对试剂、乙腈含量、pH值及色谱柱温度对六氟磷酸根保留的影响,并讨论了相关保留机理。在优化的色谱条件下,即流动相为0.05 mmol/L氢氧化四丁铵-0.038 mmol/L柠檬酸-35%乙腈(pH 5.5),流速1.0 mL/min,色谱柱温度40℃时,PF6-与其它常见阴离子(F-、Cl-、Br-、NO3-、SO24-、BF4-)达到基线分离且保留时间在15 min内。方法检出限(S/N=3)为0.25 mg/L,标准曲线的线性范围为0.5~100.0 mg/L,峰面积和保留时间的相对标准偏差(n=5)分别为0.17%和0.15%。该法用于1-丁基-3-甲基咪唑六氟磷酸盐和1-丙基-2,3-二甲基咪唑六氟磷酸盐两种离子液体中PF6-的测定,加标回收率分别为99%和104%。该方法简单、准确、可靠,实用性好。  相似文献   

9.
用流动相离子色谱法(MPIC),以两性化合物与离子对试剂的混合溶液为流动相,在C18柱上抑制电导检测分析气溶胶中常规无机阴离子和有机酸。实验采用氢氧化四丁基铵(TBAOH)为离子对试剂,与两性化合物3-(N-吗啉)-1-丙磺酸(MOPS)混合,加入Na2CO3无机添加剂作流动相,其浓度为1mmol/L TBAOH/5mmol/LMOPS/0.5mmol/LNa2CO3。分离柱采用硅质C18柱,抑制电导检测。可以较好地分离和检测常见的无机和有机阴离子。该方法具有较好的重现性和线性关系,F^-、Cl^-、NO2^-、Br^-、C3H3O3^-、NO3^-的回收率分别为102.0%、104.6%、102.4%、97.8%、97.75%和102.5%;检出限分别为0.017、0.014、0.0048、0.036、0.16和0.017mg/L。  相似文献   

10.
A solid ion-pair material produced from tetradecyldimethylbenzylammonium chloride (TDBA) and ammonium thiocyanate on naphthalene provides a simple, rapid and selective technique of preconcentrating cobalt from up to 200 ml of aqueous solution. Cobalt reacts with sodium 1-nitroso-2-naphthol-3,6-disulphonate (nitroso-R salt) to form a brown, water-soluble chelate anion. The chelate anion forms a water-insoluble Co-nitroso-R salt-TDBA complex on naphthalene packed in a column and trace cobalt is quantitatively retained on the naphthalene in the pH range 2.7–11.0 at a flow-rate of 2 ml min?1. The solid mass is stripped from the column with 5 ml of dimethylformamide (DMF) and cobalt is measured by atomic absorption spectrometry (AAS) at 241 nm. The calibration graph is linear over the concentration range 0.5–15μg Co in 5 ml of dimethylformamide solution. Seven replicate determinations of 9 μg of cobalt gave a mean absorbance of 0.095 with a relative standard deviation of 1.7%. The sensitivity for 1% absorption was 0.0834μg ml?1 (0.240 μg ml?1 for direct AAS on the aqueous solution). The proposed method was utilized for the determination of cobalt in standard aluminium alloys and steel samples.  相似文献   

11.
Cobalt and chromium release in patients undergone a metal-on-metal total hip replacement (THR) is a matter recently discussed and whose we do not have enough information about it yet. In literature there is little data and not completely indicative, in the biological fluids and organs the amounts of released metals are different. This is also due to the fact that cobalt and chromium blood levels can change depending on physical and working activity, individual feeding and metabolism. The results obtained confirm the presence of an increase of cobalt inthe blood of patients after total hip replacement, while the chromium levels are almost alike: average values in patients operated are 4.1 +/- 1.5 microg/L for cobalt (0.3 +/- 0.1 microg/L in the control group) and 4.5 +/- 2.9 microg/L for chromium (4.7 +/- 2.4 microg/L in the control group). In spite of the cobalt values stand below the concentration generally considered dangerous, the difference between the two examined groups points out that a risk exists for the health of these patients. These results must be confirmed by further studies, providing better information and more reliable and biocompatible materials.  相似文献   

12.
Yu ZY  Teshima N  Nakano S  Kawashima T 《Talanta》1996,43(9):1519-1525
A catalytic flow-injection photometric method was developed for the determination of levels of cobalt as low as 10(-10) mol 1(-1). The method is based on the catalytic action of cobalt(II) on the oxidative coupling of 3-methyl-2-benzothiazolinone hydrazone with N,N-dimethylaniline to form a colored dye (lambda(max) = 590 nm) in the presence of hydrogen peroxide. The extremely activating effect was obtained in the presence of 1,2-dihydroxybenzene-3,5-disulfonate (Tiron) and sodium hydrogencarbonate as activators. Furthermore, the sensitivity of the method was enhanced by adding sodium dodecylsulfate as a surfactant. Linear calibration graphs were obtained over the range 0.04-0.2 ng ml(-1) and 0.1-0.5 ng ml(-1) cobalt(II). respectively, at a sampling rate of 30 per hour. The detection limit (signal/noise = 3) was 5 pg ml(-1) and the relative standard deviations for 0.1 and 0.04 ng ml(-1) cobalt (n = 10) were 1.0 and 2.3%, respectively. The method was applied to the determination of cobalt in pepperbush.  相似文献   

13.
This work presents the development of an on-line pre-concentration system for simultaneous determination of Cd, Cu, Ni, V, Zn, Co and Pb in aqueous environmental samples and detection by inductively coupled plasma mass spectrometry. The system is based on cationic retention of the analytes onto a mini-column filled with silica gel modified with niobium(V) oxide. The effects of chemicals and flow variables have been investigated. The optimized operating conditions, selected as a compromise between sensitivity and analytical frequency were: sample pH 7.0, sample flow rate of 6.0mL min(-1), eluent flow rate of 2.0mL min(-1), and eluent (HNO(3)) concentration of 2.5mol L(-1). The relative standard deviation (n=7), enrichment factor and linear working range were 0.8-4.5%, 23.3-37.2 and 0.05-25.0microg L(-1), respectively. Limits of detection were between 0.01 and 0.03microg L(-1). The accuracy of the proposed method was checked with certified materials (NASS-4, NASS-5, CASS-4 and SRM 1643e). Values obtained were in accordance with those reported for the certified materials. Recovery was found to be in the range of 90-110% for a suit of water samples with variable matrices (seawater, tap water and ground water) collected in Florianopolis, Brazil.  相似文献   

14.
《Analytical letters》2012,45(12):2355-2366
Abstract

An indirect atomic absorption spectro-metric (AAS) method using electrothermal atomization (ETAAS) for the determination of cationic surfactants has been proposed. The method involves ion-pair formation between cationic surfactant and sodium hexanitro-cobaltate(III), extraction of the ion-pair into 1, 2-dichloroethane and determination of cobalt con centration in organic phase by ETAAS and hence indirectly relating to the cationic surfactant concentrations. Surfactants of the anionic and nonionic group do not interfere to a great extent, and matrix inter ferences from many other cations, anions and organics are also not observed. The method has been success fully applied to cationic surfactant determination in waste water and hair rinsers. Relative standard deviation values (RSD) of 3.2% for waste water samples and 4.3% for shampoo were observed in these analyses.  相似文献   

15.
A solid ion-pair material produced from 1,10-phenanthroline and tetraphenylborate on naphthalene provides a simple, rapid and fairly selective means of preconcentrating copper from up to 1000 ml of aqueous samples (about 200-fold concentration is possible). Copper is quantitatively adsorbed in the pH range 1.6–10.4 at a flow rate of 3 ml min?1. The solid mass (0.2 g) is dissolved from the column with 5 ml of dimethylformamide (DMF) and copper is measured by atomic absorption spectrometry at 324.7 nm. Linear calibration is obtained for 2–28 μg of copper in 5 ml of DMF solution. Replicate determination of 14 μg of copper gave a mean absorbance of 0.220 (n = 7) with a relative standard deviation of 1.5%. The sensitivity for 1% absorption was 0.093 μg ml?1. After optimization, the method was applied to determine trace copper in standard reference materials, natural waters, beverages and hair.  相似文献   

16.
魏峰  李文仙  黄建  霍军生  孙静 《色谱》2006,24(1):58-61
建立了用反相离子对高效液相色谱法分离和测定铁强化酱油中的铁营养强化剂乙二胺四乙酸铁钠(NaFeEDTA)的方法。样品经甲醇沉淀后,以Zorbax C8 色谱柱(150 mm×4.6 mm i.d.,5 μm)进行分离,以含12.5%甲醇、0.13%四丁基氢氧化铵(TBAOH)和0.052%甲酸的水溶液(pH 3.5)作为流动相,流速为1.00 mL/min,检测波长为254 nm,整个分离过程在30 min内完成。考察了NaFeEDTA在不同品牌酱油中的回收率,其中NaFeEDTA的添加量为0.50~4.00 g/L时,其回收率为94.15%~101.5%。对NaFeEDTA添加量为2.00 g/L的铁强化酱油样品重复测定6次,其峰面积的相对标准偏差为0.89%。NaFeEDTA标准溶液的最低检测限为0.03 mg/L。本方法简单、快速、重现性好,可用于铁强化酱油中NaFeEDTA含量的检测。  相似文献   

17.
Quantifying cocaine in apprehended samples is important to the Brazilian Federal Police because the concentration can indicate the origin of the drug and consequently the traffic route. In addition to the other risks of using this drug is the variability in cocaine concentration, which makes large doses lethal. Gas Chromatography with a Flame Ionization Detector (GC-FID) and a Mass Selective Detector (GC-MS) are the techniques usually employed, but these systems are not available in all police laboratories, due to the relatively high cost. In the present work, a flow-system procedure for the spectrophotometric determination of cocaine using cobalt thiocyanate as a complexing reagent was developed. In this reaction, two phases are formed: the superior (pink) contains an excess of cobalt thiocyanate solution and the lower layer (blue) contains the complex cocaine-cobalt thiocyanate. Samples and reagent are inserted through a sequential-injection valve between two air bubbles inside a reaction chamber. An optic fiber sensor connected to the chamber recorded the absorbance at 630 nm signal. The detection and quantification limits were 29.4 mg L(-1) and 98 mg L(-1), respectively. Relative standard deviation was 4.9% for solutions containing 400 mg L(-1) (n=10), with stable baselines. The analytical throughput was 12 determinations per hour.  相似文献   

18.
An ion-pair liquid chromatographic assay was developed and validated for the determination of ceftriaxone in cerebrospinal fluid. Chromatographic separation was achieved on a C18 column (125 x 4 mm, 5 microm) with detection at 270 nm, a 1 mL/min flow rate and a 50 microL loop. The mobile phase consisted of 300 mL acetonitrile, 50 mL 0.1M phosphate buffer (pH 7.4), 3.2 g tetrabutylammonium bromide as the ion-pairing agent, and dilution with distilled deionized water to 1 L. Cephradine was used as the internal standard. The assay was linear for ceftriaxone concentrations of 0.5-50 microg/mL. The coefficients of variation for precision were <4.61%. The accuracy ranged from 96.07 to 102.42%. The detection and quantitation limits were 0.019 and 0.065 microg/mL, respectively. This method was used to quantify ceftriaxone in the cerebrospinal fluid of children with meningitis. The results showed that the method described here is useful for the determination of ceftriaxone in cerebrospinal fluid.  相似文献   

19.
Gomis DB  Jimeno SA  Sanz-Medel A 《Talanta》1982,29(9):761-765
A method is described for the direct spectrophotometric determination of micro-amounts of niobium by extraction into a benzene solution of dibenzo-18-crown-6 (L) from 3M hydrochloric acid containing potassium thiocyanate. The molar absorptivity of the extracted complex is 3.85 +/- 0.03 x 10(4) 1.mole(-1).cm(-1) (relative standard deviation 0.8%). Co-ordinatively unsaturated complexes of the type [NbO(SCN)(3)](2)L and NbO(SCN)(3)L are extracted, along with ion-pairs, especially when small amounts of L are used for extraction. The ion-pair complex [NbOCl(2)(SCN)(3)][(LK)(2)] seems to be the main species formed in the organic phase.  相似文献   

20.
The electrocatalytic activity of a supramolecular complex based on cobalt(II) phthalocyanine tetrasulfonate and iron(III) tetra-(N-methyl-4-pyridyl)-porphyrin adsorbed on multi-walled carbon nanotubes for the oxidation of L-glutathione (GSH) was investigated at pH 7.4. Scanning electron microscopy and energy dispersive X-ray spectrometry were used to characterize the morphologies and composition of the materials. The modified electrode displayed efficient electrocatalytic activity in terms of oxidation of GSH at an oxidation potential of 0 V (versus Ag/AgCl). Cyclic voltammetry and amperometry indicated that the oxidation involves 2-electrons, with a heterogeneous rate constant of 4.9?×?105 mol?1 L s?1. The response is linear from 2 to 210 μmol ?L-1, the sensitivity is 1570 μA L mmol?1, the detection limit is 0.03 μmol L?1, and the relative standard deviation of 110 μmol L?1 GSH was 2.6% (n?=?10). The modified electrode was applied to the determination of GSH in erythrocytes and the results were in agreement with those obtained by a method reported in the literature.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号