首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
Beryllium(II) selective electrodes have been fabricated based on poly(vinyl chloride) (PVC) matrix membranes containing newly synthesized neutral carrier dibenzo(perhydrotriazino)aza-14-crown-4 ethers as ionophore. Best performance was exhibited by the membrane having a composition ionophore (IIa):PVC:sodium tetraphenylborate (NaTPB):tributyl phosphate (TBP) in the ratio (w/w; mg) of 5:30:3:65. This membrane worked well over a wide concentration range 7.6 × 10−6 to 1.0 × 10−1 M of Be2+ with a Nernstian slope of 30.7 mV per decade of beryllium activity. The response time of the sensor is 15 s and the membrane can be used over a period of 4 months with good reproducibility. The proposed electrode works well in a wide pH range 3.0–9.0. It was successfully applied to the determination of beryllium in a mineral sample.  相似文献   

2.
Wang X  Zeng H  Zhao L  Lin JM 《Talanta》2006,70(1):160-168
A bifurcated optical fiber based chemical sensor for continuous monitoring of 2,6-dinitrophenol (2,6-DNP) has been proposed based on the reversible chemical reaction between a novel functional poly(vinyl chloride) (PVC) as the sensing material and the analytes. The functional PVC (FPVC), containing a fluorescent curcumin moiety, was synthesized by the nucleophilic substitution of a fraction of the chlorine atoms bound to the PVC backbone by curcumin. When plasticized in a membrane of 5 μm thickness, FPVC extracts 2,6-DNP from aqueous solution into the bulk membrane phase and reacts with the analyte to form a complex with low fluorescence efficiency through hydrogen bonding. Formation of the complex gave a significant fluorescence quenching which is suitable for signalling the occurrence of the host-guest interaction. At pH 3.50, the sensor exhibits a dynamic detection range from 2.5 × 10−6 to 7.0 × 10−3 mol L−1 with a limit of detection of 1.0 × 10−6 mol L−1. As 2,6-DNP can provide an optimal space geometry matches to the formation of hydrogen bonds, the sensor shows excellent selectivity for 2,6-DNP over other nitrophenols. The forward and reverse response time (t95) of the sensor both was within 1 min. The repeatability, reproducibility, and lifetime of the sensor were also satisfied. The sensor was applied to determine 2,6-DNP in water samples successfully.  相似文献   

3.
In this work, a highly selective and sensitive monohydrogen phosphate membrane sensor based on a molybdenum bis(2-hydroxyanil) acetylacetonate complex (MAA) is reported. The sensor shows a linear dynamic range between 1.0 × 10−1 and 1.0 × 10−7 M, with a nice Nernstian behavior (−29.5 ± 0.3 mV decade−1) in pH of 8.2. The detection limit of the electrode is 6.0 × 10−8 M (∼6 ppb). The best performance was obtained with a membrane composition of 32% poly(vinyl chloride), 58% benzyl acetate, 2% hexadecyltrimethylammonium bromide and 8% MAA. The sensor possesses the advantages of short response time, low detection limit and especially, very good selectivity towards a large number of organic and inorganic anions including salicylate, citrate, tartarate, acetate, oxalate, fluoride, chloride, bromide, iodide, sulfite, sulfate, nitrate, nitrite, cyanide, thiocyanate, perchlorate, metavanadate, and bicarbonate ions. The electrode can be used for at least 10 weeks without any considerable divergence in its slope and detection limit. It was used as an indicator electrode in potentiometric titration of monohydrogenphosphate ion with barium chloride. The proposed sensor was successfully applied to direct determination of monohydrogenphosphate in two fertilizer samples (NPK).  相似文献   

4.
This paper describes a copper selective optical chemical sensor based on static quenching of the fluorescence of 2-(2′-hydroxyphenyl)benzoxazole entrapped in a poly(vinyl chloride) (PVC) membrane. The effect of the composition of the sensing membrane was studied, and experimental conditions were optimized. The sensors exhibit stable response over the concentration range from 4.0 × 10−8 M to 5.0 × 10−5 M Cu2+ at pH 4.0-6.5, and a high selectivity. The response time for Cu2+ with concentration ≤5 × 10−6 M is less than 7 min. The optode can be regenerated using 0.1 M HCl and acetate buffer solution. The sensor has been used for direct measurement of copper content in river water samples with a relative error less than 4% with reference to that obtained by atomic absorption spectrometry.  相似文献   

5.
A new micelle-mediated phase preconcentration method for preconcentration of ultra-trace quantities of beryllium as a prior step to its determination by spectrophotometry has been developed. Chrome Azurol S (CAS) and cetyltrimethylammonium bromide (CTAB) were used as chelating agent and cationic surfactant, respectively. The method evaluates and eliminates the blank bias error present in such procedures using mean centering of ratio spectra. This procedure gives more accurate results than the traditional approach using absorbance values against reagent blank. The optimal extraction and reaction conditions were studied and the analytical characteristics of the method (e.g., limit of detection, linear range, preconcentration and improvement factors) were obtained. Linearity was obeyed in the range of 0.9-18.0 ng mL−1 (1.00 × 10−7-2.00 × 10−6 mol L−1) of beryllium. The detection limit of the method is 0.51 ng mL−1 (5.66 × 10−8 mol L−1) of beryllium. The interference effect of some anions and cations was also tested. The method was applied to the determination of beryllium in spring water samples.  相似文献   

6.
A bifurcated optical fiber chemical sensor for continuous monitoring of bisphenol A (BPA) has been proposed based on the fluorescence quenching (λex/λem = 286/390 nm) of pyrene/dimethyl β-cyclodextrin (HDM-β-CD) supramolecular complex immobilized in a plasticized poly(vinyl chloride) (PVC) membrane, in which pyrene served as a sensitive fluorescence indicator probe. The decrease of the fluorescence intensity of pyrene/HDM-β-CD complex upon the addition of BPA was attributed to the displacement of pyrene by BPA, which has been utilized as the basis of the fabrication of a BPA-sensitive fluorescence sensor. The response mechanism of the sensor was discussed in detail. The sensor exhibited a dynamic detection range from 7.90 × 10−8 to 1.66 × 10−5 mol L−1 with a detection limit of 7.00 × 10−8 mol L−1, and showed excellent reproducibility, reversibility, selectivity, and lifetime. The proposed sensor was successfully used for the determination of BPA in water samples and landfill leachate.  相似文献   

7.
A highly selective poly(vinyl chloride) (PVC) membrane electrode based on 1,8-dibenzyl-1,3,6,8,10,13-hexaazacyclotetradecane-Ni(II) as a membrane carrier with unique selectivity toward thiocyanate is reported. The influence of membrane composition, pH and foreign anions were investigated. The sensor exhibits a Nernstian response for thiocyanate over a wide concentration range of 3.3×10−6 to 0.10 M, with a slope 58.4±0.3 mV per decade. The limit of detection is 3.0×10−6 M SCN. The sensor has a response time of <20 s and can be used for at least 2 months without any considerable divergence in potential. The proposed electrode shows fairly a good discriminating ability towards SCN ion in comparison to other anions. It was successfully applied to direct determination of thiocyanate in urine and saliva and it was also used as an indicator electrode in titration of thiocyanate with Ag+ ions.  相似文献   

8.
Bis(2-hydroxyacetophenone)butane-2,3-dihydrazone (BHAB) was used as new N-N Schiffs base which plays the role of an excellent ion carrier in the construction of a Cu(II) membrane sensor. The best performance was obtained with a membrane composition of 30% poly(vinyl chloride), 55% o-nitrophenyloctyl ether (NPOE), 7% BHAB and 8% oleic acid (OA). This sensor shows very good selectivity and sensitivity towards copper ion over a wide variety of cations, including alkali, alkaline earth, transition and heavy metal ions. The effect of membrane composition and pH and influence of additive anionic on the response properties of electrode were investigated. The electrode exhibits a Nernstian behavior (with slope of 29.6 mV per decade) over a very wide concentration range (5.0 × 10−8 to 1.0 × 10−2 mol L−1) with a detection limit of 3.0 × 10−8 mol L−1 (2.56 ng mL−1). It shows relatively fast response time, in whole concentration range (<15 s), and can be used for at least 12 weeks in the pH range of 2.8-5.8. The proposed sensor was successfully used to determination of copper in different water samples and as indicator electrode in potentiometric titration of copper ion with EDTA.  相似文献   

9.
A poly(vinyl chloride)-based membrane of 2,9-dimethyl-4,11-diphenyl-1,5,8,12-tetraazacyclotetradeca-1,4,8,11-tetraene (DDTCT) with sodium tetraphenyl borate (STB) as an anion excluder and dibutyl phthalate (DBP), dibutyl butylphosphonate (DBBP), tris(2-ethylhexyl) phosphate (TEP) and tributyl phosphate (TBP) as plasticizing solvent mediators was prepared and investigated as a Ga(III)-selective electrode. The best performance was observed with the membrane having the ligand-PVC-DBP-STB composition 1:4:1:1, which worked well over a wide concentration range (1.45 × 10−6 to 0.1 mol L−1) with a Nernstian slope of 28.7 mV per decade of activity between pH 4.0 and 10.0. This electrode showed a fast response time of 12 s and was used over a period of 100 days with good reproducibility (s = 0.3 mV). The selectivity coefficients for monovalent, divalent and trivalent cations indicate excellent selectivity for Ga(III) ions over a large number of cations. Anions such as Cl and SO42− do not interfere and the electrode also works satisfactorily in partially water-alcohol medium. The practical utility of the membrane sensor has also been observed in solutions contaminated with detergents, i.e., cetyltrimethylammonium bromide and sodium dodecyl sulfate and used for the determination of gallium in nickel alloy, fly-ash and biological samples.  相似文献   

10.
In this study, a new poly(vinyl chloride) (PVC) membrane sensor for La3+ ion based on 2,2′-dithiodipyridine as an ion carrier was prepared. This electrode revealed good selectivity for La3+ over a wide variety of other metal ions. Effects of experimental parameters such as membrane composition, nature and amount of plasticizer, the amount of additive and concentration of internal solution on the potential response of La3+ sensor were investigated. The electrode exhibited a Nernstian slope of 20.0 ± 1.0 mV per decade of La3+ over a concentration range of 7.1 × 10−6 to 2.2 × 10−2 M of La3+ in the pH range 3.3-8.0. The response time was about 7 s and the detection limit was 3.1 × 10−6 M. The electrode can be used for at least 2 months without a considerable divergence in potential. The proposed electrode was used as an indicator electrode in potentiometric titration of oxalate and fluoride ions and was applied for determination of F ion in mouthwash solution.  相似文献   

11.
A novel poly(vinyl chloride) (PVC) membrane electrode based on naphto-9-crown-3 was prepared and tested for the selective detection of beryllium ions. A suitable lipophilicity of the carrier and appropriate coordination ability were found to be essential for designing an electrode with good response characteristics. A PVC membrane with 9% naphtho-9-crown-3 carrier, 58% o-NPOE plasticizer, 3% tetraphenylborate anionic excluder and 30% poly(vinyl chloride) satisfied these requirements. The proposed sensor displayed a linear response to beryllium over a wide concentration range of 1.0 x 10(-1)-8.0 x 10(-6) M with a Nernstian slope of 29.5 mV per decade. The electrode showed very short response time (<15 s) and could be used in the pH range 3.5-9.0. The selectivity coefficient for alkali, alkaline earth, transition and heavy metal ions was smaller than 4.0 x 10(-4). The sensor was successfully used as an indicator electrode in the potentiometric titration of Be2+ with EDTA. The proposed Be(II) sensor was also used for the determination of Be2+ ions in binary mixtures.  相似文献   

12.
A new fluorogenic method for selective and sensitive determination of beryllium using 2,6-diphenyl-4-benzo-9-crown-3-pyrane (DBCP) was developed. The proposed fluorescent probe undergoes fluorescent emission intensity enhancement upon binding to beryllium ions in MeOH/H(2)O (70:30, v/v) solution. The fluorescence enhancement of DBCP is attributed to a 1:1 complex formation between DBCP and Be(2+) ion, which has been utilized as the basis for selective detection of Be(2+) ion. With the optimum condition described, the fluorescence enhancement at 531 nm was linear to the concentration of beryllium in the range of 1.6×10(-8)-1.6×10(-7) M and a detection limit of 1.5×10(-9) M. The fluorescent probe exhibits high selectivity for Be(2+) ion over the other common mono, di- and trivalent cations.  相似文献   

13.
Nickel(II)-selective sensor based on dibenzo-18-crown-6 in PVC matrix   总被引:1,自引:0,他引:1  
Nickel(II)-selective sensors have been fabricated from poly(vinyl chloride) (PVC) matrix membranes containing neutral carrier dibenzo-18-crown-6 as electroactive material, sodium tetraphenylborate (NaTPB) as an anion excluder and tris-(2-ethylhexyl) phosphate (TEHP) as plasticizing solvent mediator. The membrane having the composition of crown ether:NaTPB:TEHP:PVC in the ratio 10:1:200:200 (w/w) exhibits best results with linear potential response in the concentration range of 1.0 × 10−5 to 1.0 × 10−1 M and a Nernstian slope of 29.5 mV/decade of activity between 2.6 and 6.8. The sensor exhibits a fast response time of <25 s, is inert towards non-aqueous medium up to 15% (v/v) and was used over a period of 4 months with good reproducibility. It is selective over a number of mono-, bi- and trivalent cations. The practical utility of the sensor has been demonstrated by using it as an indicator electrode in the potentiometric titration of Ni2+ against EDTA and also for the estimation of Ni2+ in some Indian brand chocolates.  相似文献   

14.
Mittal SK  Kumar SK  Sharma HK 《Talanta》2004,62(4):801-805
A new ion-selective electrode (ISE) based on dicyclohexano-18-crown-6 (DC18C6) as a neutral carrier is developed for lanthanum(III) ions. The electrode comprises of dicyclohexano-18-crown-6 (6%), PVC (33%), and ortho-nitrophenyl octyl ether (o-NPOE) (61%). The electrode shows a linear dynamic response in the concentration range of 10−6 to 10−1 M with a Nernstian slope of 19 mV per decade and a detection limit as 5×10−7 M. It has a response time of <30 s and can be used for at least 5 months without any significant divergence in potentials. The selectivity coefficients for mono-, di-, and trivalent cations indicate good selectivity for La(III) ions over a large number of interfering cations. The sensor has been used as an indicator electrode in the potentiometric titrations of La(III) with EDTA. The membrane is successfully applied in partially non-aqueous medium. It can be used in the pH range 4-9.  相似文献   

15.
An optical sensor for mercury ion (Hg2+), based on quenching the fluorescence of the sensing reagent porphyrin immobilized in plasticized poly(vinyl chloride) (PVC) membrane, has been developed. The responses to mercury ion were compared for the sensors modified with three porphyrin compounds including 5,10,15,20-tetraphenylporphyrin (TPP), tetra(p-dimethylaminophenyl)porphyrin (TDMAPP) and tetra(N-phenylpyrazole) porphyrin (TPPP). Among them, TDMAPP showed the most remarkable response to Hg2+. The drastic decrease of the TDMAPP fluorescence intensity was attributed to the formation of a complex between TDMAPP and Hg2+, which has been utilized as the fabrication basis of a Hg2+-sensitive fluorescence sensor. The analytical performance characteristics of the TDMAPP modified sensor was investigated. The response mechanism, especially involving the response difference of three porphyrin compounds, was discussed in detail. The sensor can be applied to the quantification of Hg2+ with a linear range covering from 4.0 × 10−8 mol L−1 to 4.0 × 10−6 mol L−1. The limit of detection was 8.0 × 10−9 mol L−1. The sensor exhibited excellent reproducibility, reversibility and selectivity. Also, the TDMAPP-based sensor was successfully used for the determination of Hg2+ in environmental water samples.  相似文献   

16.
Three different derivatives of macrocyclic tetraimine Schiff's base have been synthesized and explored as a neutral ionophores for preparing poly(vinyl chloride) based membrane sensors selective to Dy3+. The addition of sodium tetraphenyl borate and various plasticizers, viz., o-NPOE, DBP, DBBP, DOP and CN has been found to substantially improve the performance of the sensors. The best performance was obtained with the sensor no. 1 having membrane of Schiff's base (SL-1) with composition (w/w) SL-1 (4.5%): PVC (30.5%): o-NPOE (59.5%): NaTPB (5.5%). This sensor exhibits Nernstian response with slope 19.4 mV/decade of activity in the concentration range of  10−8 to 1.0 × 10−2 M Dy3+, performs satisfactorily over wide pH range of (2.8-7.2) with a fast response time (10 s). The sensor was also found to work satisfactorily in partially non-aqueous media up to 20% (v/v) content of acetonitrile, methanol or ethanol. The proposed sensor can be used over a period of 1.5 months without significant drift in potentials. The sensor has been also utilized for the determination of Dy3+ level in different soil samples.  相似文献   

17.
Pankaj Kumar 《Talanta》2009,77(3):1057-234
A new poly(vinyl chloride)-based membranes containing p-(4-n-butylphenylazo)calix[4]arene (I) as an electroactive material along with sodiumtetraphenylborate (NaTPB), and dibutyl(butyl)phosphonate in the ratio 10:100:1:200 (I:DBBP:NaTPB:PVC) (w/w) was used to fabricate a new cobalt(II)-selective sensor. It exhibited a working concentration range of 9.2 × 10−6 to 1.0 × 10−1 M, with a Nernstian slope of 29.0 ± 1.0 mV/decade of activity and the response time of 25 s. This sensor shows the detection limit of 4.0 × 10−6 M. Its potential response remains unaffected of pH in the range, 4.0-7.2, and the cell assembly can be used successfully in partially non-aqueous medium (up to 10%, v/v) without significant change in the slope of working concentration range. The sensor has a lifetime of about 3 months and exhibits excellent selectivity over a number of mono-, bi-, and tri-valent cations including alkali, alkaline earth metal, heavy and transition metal ions. It can be used as an indicator electrode for the end point determination in the potentiometric titration of cobalt ions against ethylenediaminetetraacetic acid (EDTA) as well as for the determination of cobalt ion concentration in real samples.  相似文献   

18.
Hassan SS  Attawiya AM 《Talanta》2006,70(4):883-889
A novel potentiometric uranyl membrane sensor with a divalent anionic response is developed, characterized and used for determination of uranyl ion. The sensor incorporates triethylenetetramine (TETA) as an ionophore in poly(vinyl chloride) matrix membrane (PVC) plasticized with o-nitrophenyloctyl ether (o-NPOE). In strong sulphate test solutions, UO22+ ion forms a highly stable [UO2(SO4)2]2− anion, extractable in TETA as {(2TETAH)2+ [UO2(SO4)2]2−} complex. Formation of the complex is confirmed and characterized by elemental analysis, mass spectrometry and infrared spectrometry. Sensor based on this system displays at pH 2.5-3.8 a linear response over the concentration range of 1.0 × 10−1-3.5 × 10−5 mol l−1 uranium with a near-Nernstian calibration slope of −26.5 ± 0.3 mV decade−1. The lower limit of detection is ∼5 μg ml−1, the lifetime is 12 weeks and negligible interferences are caused by most common cations. Validation of the assay method reveals excellent performance characteristics in terms of sensitivity, selectivity, fast response and potential stability. The sensor is used for the determination of 0.01-7.09 wt% uranium in naturally occurring and certified ore samples. The results show an average recovery of 97.6% and compare fairly well with data obtained using X-ray fluorescence technique.  相似文献   

19.
A supported liquid and a poly(vinyl chloride) (PVC)-based membrane selective for dodecylsulfate (DS) ion are described. The active element is a membrane containing a dissolved ion association complex of DS with cetylpyridinium (CP+) cation. The supported liquid membrane electrode (acetophenone as solvent) showed a Nernstian response towards the DS anion over the concentration range of sodium dodecylsulfate (SDS) from 8.3×10−3 to 1.0×10−6 mol dm−3 at 25 °C. The proposed electrode also showed a super-Nernstian potential response (108±2 mV decade−1) at low concentrations (1.0×10−9 to 1.0×10−6 mol dm−3). Moreover, this electrode showed good selectivity and precision (R.S.D.?2.0%), and was usable within the pH range 4.0-6.8. The proposed electrode revealed a lower limit of detection of 6.3×10−7 mol dm−3 and improved selectivity in comparison with the some previously reported DS ion selective electrodes. The isothermal temperature coefficient of this electrode amounted to −0.001 V °C−1. The liquid membrane electrode may find application in the direct determination of SDS by the standard addition method at pH 5.0, and in the physicochemical studies of surfactant solutions.  相似文献   

20.
Zinc(II)-selective sensors based on dibenzo-24-crown-8 in PVC matrix   总被引:1,自引:0,他引:1  
Membranes of dibenzo-24-crown-8 (I) as an ion active material in poly(vinylchloride) (PVC) based matrix have been tried for zinc(II)-selective sensors. The effect of anion excluder, sodium tetraphenylborate (NaTPB) and plasticizers, tris(2-ethylhexyl)phosphate (TEP), tributylphosphate (TBP), dibutylphthalate (DBP), dibutyl(butyl)phosphonate (DBBP), 1-chloronaphthalene (CN) and dioctylphthalate (DOP) on the performance of the membrane electrodes has also been studied. It was observed that the membrane having the composition (I): PVC:NaTPB:DOP in the ratio 10:200:2:100 gave the best results with a wide working concentration range of 9.2 × 10−5 to 1.0 × 10−1 M, Nernstian slope of 29.0 ± 0. 5 mV/decade of activity, fast response time of 12 s and good selectivity over a number of mono-, bi-, and trivalent cations. The sensor works well in a pH range 4.8-6.2 and can be employed for the estimation of zinc ions in partially non-aqueous medium having up to 10% (v/v) methanol, ethanol or acetone content. The practical utility of the sensor has been demonstrated by using it successfully as an indicator electrode in the potentiometric titration of Zn2+ with EDTA and also for the determination of Zn2+ in a real sample analysis of wastewater.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号