首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
The new 10 μg l−1 arsenic standard in drinking water has been a spur to the search for reliable routine analytical methods with a limit of detection at the μg l−1 level. These methods also need to be easy to handle due to the routine analyses that are required in drinking water monitoring. Graphite furnace atomic absorption spectrometry (GFAAS) meets these requirements, but the limit of detection is generally too high except for methods using a pre-concentration or separation step. The use of a high-intensity boosted discharge hollow-cathode lamp decreases the baseline noise level and therefore allows a lower limit of detection. The temperature program, chemical matrix modifier and thermal stabilizer additives were optimized for total inorganic arsenic determination with GFAAS, without preliminary treatment. The optimal furnace program was validated with a proprietary software. The limit of detection was 0.26 μg As l−1 for a sample volume of 16 μl corresponding to 4.2 pg As. This attractive technique is rapid as 20 samples can be analysed per hour. This method was validated with arsenic reference solutions. Its applicability was verified with artificial and natural groundwaters. Recoveries from 91 to 105% with relative standard deviation <5% can be easily achieved. The effect of interfering anions and cations commonly found in groundwater was studied. Only phosphates and silicates (respectively at 4 and 20 mg l−1) lead to significant interferences in the determination of total inorganic arsenic at 4 μg l−1.  相似文献   

2.
Lead is recognized worldwide as a poisonous metal. Thus, the determination of this element is often required in environmental, biological, food and geological samples. However, these analyses are difficult because such samples contain relatively low concentrations of lead, which fall below the detection limit of conventional analytical techniques such as flame atomic absorption spectrometry and inductively coupled plasma optical emission spectrometry. Several preconcentration procedures to determine lead have therefore been devised, involving separation techniques such as liquid-liquid extraction, solid phase extraction, coprecipitation and cloud point extraction. Citing 160 references, this paper offers a critical review of preconcentration procedures for determining lead using spectroanalytical techniques.  相似文献   

3.
The members of the committee NMP 264 “Chemical analysis of non-oxidic raw and basic materials” of the German Standards Institute (DIN) have organized two interlaboratory comparisons for multielement determination of trace elements in silicon carbide (SiC) powders via direct solid sampling methods. One of the interlaboratory comparisons was based on the application of inductively coupled plasma optical emission spectrometry with electrothermal vaporization (ETV ICP OES), and the other on the application of optical emission spectrometry with direct current arc (DC arc OES). The interlaboratory comparisons were organized and performed in the framework of the development of two standards related to “the determination of mass fractions of metallic impurities in powders and grain sizes of ceramic raw and basic materials” by both methods. SiC powders were used as typical examples of this category of material. The aim of the interlaboratory comparisons was to determine the repeatability and reproducibility of both analytical methods to be standardized. This was an important contribution to the practical applicability of both draft standards. Eight laboratories participated in the interlaboratory comparison with ETV ICP OES and nine in the interlaboratory comparison with DC arc OES. Ten analytes were investigated by ETV ICP OES and eleven by DC arc OES. Six different SiC powders were used for the calibration. The mass fractions of their relevant trace elements were determined after wet chemical digestion. All participants followed the analytical requirements described in the draft standards. In the calculation process, three of the calibration materials were used successively as analytical samples. This was managed in the following manner: the material that had just been used as the analytical sample was excluded from the calibration, so the five other materials were used to establish the calibration plot. The results from the interlaboratory comparisons were summarized and used to determine the repeatability and the reproducibility (expressed as standard deviations) of both methods. The calculation was carried out according to the related standard. The results are specified and discussed in this paper, as are the optimized analytical conditions determined and used by the authors of this paper. For both methods, the repeatability relative standard deviations were <25%, usually ~10%, and the reproducibility relative standard deviations were <35%, usually ~15%. These results were regarded as satifactory for both methods intended for rapid analysis of materials for which decomposition is difficult and time-consuming. Also described are some results from an interlaboratory comparison used to certify one of the materials that had been previously used for validation in both interlaboratory comparisons. Thirty laboratories (from eight countries) participated in this interlaboratory comparison for certification. As examples, accepted results are shown from laboratories that used ETV ICP OES or DC arc OES and had performed calibrations by using solutions or oxides, respectively. The certified mass fractions of the certified reference materials were also compared with the mass fractions determined in the interlaboratory comparisons performed within the framework of method standardization. Good agreement was found for most of the analytes.  相似文献   

4.
In recent years, knowledge of the different chemical forms of the elements has gained increasing importance. There has been significant progress in methods that hyphenate chromatographic separations with atomic spectrometry. These hyphenated methods can provide the most complete information on the species distribution and even structure. However, they can be lengthy, relatively costly and difficult to bring to the routine. On the other hand, it is important to remember that chromatographic techniques represent only a minor part of the separation procedures available and, in certain cases, the application of basic chemistry to sample treatments can give quantitative information about specific chemical forms. In this sense, non-chromatographic procedures can provide methods that offer sufficient information on the elemental speciation for a series of situations. Moreover, these non-chromatographic strategies can be less time consuming, more cost effective and available, and present competitive limits of detection. Thus, non-chromatographic speciation analysis continues to be a promising research area and has been applied to the development of several methodologies that facilitate this type of analytical approach. In view of their importance, the present work overviews and discusses different non-chromatographic methods as alternatives for the speciation analysis of clinical, environmental and food samples using atomic spectrometry for detection.  相似文献   

5.
Within the last decade, liquid-phase microextraction (LPME) and micro-solid phase extraction (μSPE) approaches have emerged as substitutes for conventional sample processing procedures for trace metal assays within the framework of green chemistry. This review surveys the progress of the state of the art in simplification and automation of microextraction approaches by harnessing to the various generations of flow injection (FI) as a front end to atomic absorption spectrometry (AAS), atomic fluorescence spectrometry (AFS) or inductively coupled plasma atomic emission spectrometry or mass spectrometry (ICP-AES/MS). It highlights the evolution of flow injection analysis and related techniques as vehicles for appropriate sample presentation to the detector and expedient on-line matrix separation and pre-concentration of trace levels of metals in troublesome matrices. Rather than being comprehensive this review is aimed at outlining the pros and cons via representative examples of recent attempts in automating green sample preparation procedures in an FI or sequential injection (SI) mode capitalizing on single-drop microextraction, dispersive liquid-phase microextraction and advanced sorptive materials including carbon and metal oxide nanoparticles, ion imprinted polymers, superparamagnetic nanomaterials and biological/biomass sorbents. Current challenges in the field are identified and the synergetic combination of flow analysis, nanotechnology and metal-tagged biomolecule detection is envisaged.  相似文献   

6.
A solid phase extraction (SPE) procedure based on Amberlite IRA 900 resin was developed for speciation and separation of inorganic arsenic species (III, V) and total As in water samples. The As species and total As in eluent solutions were determined by electrothermal atomic absorption spectrometry (ETAAS) using Ni chemical modifier with 1200°C pyrolysis temperature. Experimental parameters such as pH value, sample volume, flow rate, volume and concentration of eluent solution for As(V) were optimised and 98.0 ± 1.9% recovery was found at pH 4.0. Experimental adsorption capacity of the resin for As(V) was investigated and 229.9 mg g1 was found. Under optimised experimental conditions, instrumental parameters such as limit of detection (LOD) and limit of quantification (LOQ) found were 0.126 and 0.420 µg L1, respectively. Interference effects of coexisting ions in the sample matrix on the recovery of As(V) were investigated. Concentration of As(III) was obtained by subtracting As(V) concentration found at pH 4.0 from total As(III + V) found at pH 8.0. The accuracy of the method proposed by using the resin was tested for analysing As species in a waste water standard reference material (SRM, CWW-TM-D) and spiked real water samples with recovery above 95%. The method proposed was also applied to the determinations of As species and total As in underground hot waters and tap water with relative error below 3%.  相似文献   

7.
The determination of trace metals in lubricating oils using atomic spectrometric methods is reviewed. The importance of such analyses for technical diagnostics as well as the specific sample characteristics related to the analyte form (metallo-organic and metal particles) is discussed. Problems related to sample pre-treatment for appropriate sample introduction and calibration are addressed as well as the strategies to overcome them. Recent trends aimed at simplifying sample manipulation are presented. The applications and scope of AAS, ICP OES and ICP MS techniques for the determination of trace metals in lubricating oil is individually discussed, as well as some present instrumental trends.  相似文献   

8.
Inorganic arsenic (As) displays extreme toxicity and is a class A human carcinogen. It is of interest to both analytical chemists and environmental scientists. Facile and sensitive determination of As and knowledge of the speciation of forms of As in aqueous samples are vitally important. Nearly every nation has relevant official regulations on permissible limits of drinking water As content. The size of the literature on As is therefore formidable. The heart of this review consists of two tables: one is a compilation of principal official documents and major review articles, including the toxicology and chemistry of As. This includes comprehensive official compendia on As speciation, sample treatment, recommended procedures for the determination of As in specific sample matrices with specific analytical instrument(s), procedures for multi-element (including As) speciation and analysis, and prior comprehensive reviews on arsenic analysis. The second table focuses on the recent literature (2005–2013, the coverage for 2013 is incomplete) on As measurement in aqueous matrices. Recent As speciation and analysis methods based on spectrometric and electrochemical methods, inductively coupled plasma-mass spectrometry, neutron activation analysis and biosensors are summarized. We have deliberately excluded atomic optical spectrometric techniques (atomic absorption, atomic fluorescence, inductively coupled plasma-optical emission spectrometry) not because they are not important (in fact the majority of arsenic determinations are possibly carried out by one of these techniques) but because these methods are sufficiently mature and little meaningful innovation has been made beyond what is in the officially prescribed compendia (which are included) and recent reviews are available.  相似文献   

9.
Selenium is an essential element for the normal cellular function of living organisms. However, selenium is toxic at concentrations of only three to five times higher than the essential concentration. The inorganic forms (mainly selenite and selenate) present in environmental water generally exhibit higher toxicity (up to 40 times) than organic forms. Therefore, the determination of low levels of different inorganic selenium species in water is an analytical challenge. Solid-phase extraction has been used as a separation and/or preconcentration technique prior to the determination of selenium species due to the need for accurate measurements for Se species in water at extremely low levels. The present paper provides a critical review of the published methods for inorganic selenium speciation in water samples using solid phase extraction as a preconcentration procedure. On the basis of more than 75 references, the different speciation strategies used for this task have been highlighted and classified. The solid-phase extraction sorbents and the performance and analytical characteristics of the developed methods for Se speciation are also discussed.  相似文献   

10.
This is the first publication which describes the development of a reference material (RM) for the determination of 11 trace elements (Cu, Pb, Mn, Ni, Zn, Fe, Cd, Co, V, As and Al) in rainwater at microgram per liter concentrations. An interlaboratory comparison study for the determination of trace elements in rainwater was carried out for material performance studies to establish analyte concentrations with a stated uncertainty. Fifteen reputed laboratories from Asia, Europe and North America participated in the study. These laboratories used their regular in-house methods to analyze the rainwater samples. The aim of this study is to establish concentration levels of trace elements in rainwater based on interlaboratory study results. Details of the production, homogeneity and stability of the reference sample are given in this article. The organization of the study and the quality assurance measures undertaken at the organizer's laboratory are described. The analytical results obtained from individual laboratories and the analytical methods used for the determination of trace elements in rainwater are discussed. Based on the results obtained from the intercomparison study, certified values as well as informative values are assigned to the 11 trace elements in rainwater.  相似文献   

11.
In this review sample preparation strategies used for crude oil digestion in last ten years are discussed focusing on further metals and non-metals determination. One of the main challenges of proposed methods has been to overcome the difficulty to bring crude oil samples into solution, which should be compatible with analytical techniques used for element determination. On this aspect, this review summarizes the sample preparation methods for metals and non metals determination in crude oil including those based on wet digestion, combustion, emulsification, extraction, sample dilution with organic solvents, among others. Conventional methods related to wet digestion with concentrated acids or combustion are also covered, with special emphasis to closed systems. Trends in sample digestion, such as microwave-assisted digestion using diluted acids combined with high-efficiency decomposition systems are discussed. On the other hand, strategies based on sample dilution in organic solvents and procedures recommended for speciation analysis are reported as well as the use of direct analysis in view of the recent importance for crude oil field. A compilation concerning sample preparation for crude oil provided by official methods as well as certified reference materials available for accuracy evaluation is also presented and discussed.  相似文献   

12.
Analytical chemistry is playing an ever-increasingly important role in the global wine industry. Chemical analysis of wine is essential in ensuring product safety and conformity to regulatory laws governing the international market, as well as understanding the fundamental aspects of grape and wine production to improve manufacturing processes. Within this field, advanced instrumental analysis methods have been exploited more extensively in recent years. Important advances in instrumental analytical techniques have also found application in the wine industry. This review aims to highlight the most important developments in the field of instrumental wine and grape analysis in the African context. The focus of this overview is specifically on the application of advanced instrumental techniques, including spectroscopic and chromatographic methods. Recent developments in wine and grape analysis and their application in the African context are highlighted, and future trends are discussed in terms of their potential contribution to the industry.  相似文献   

13.
We review recent progress in preconcentration strategies associated to vapor generation techniques coupled to atomic spectrometric (VGT-AS) for specific chemical species detection. This discussion focuses on the central role of different preconcentration approaches, both before and after VG process. The former was based on the classical solid phase and liquid–liquid extraction procedures which, aided by automation and miniaturization strategies, have strengthened the role of VGT-AS in several research fields including environmental, clinical, and others. We then examine some of the new vapor trapping strategies (atom-trapping, hydride trapping, cryotrapping) that entail improvements in selectivity through interference elimination, but also they allow reaching ultra-low detection limits for a large number of chemical species generated in conventional VG systems, including complete separation of several species of the same element. This review covers more than 100 bibliographic references from 2009 up to date, found in SCOPUS database and in individual searches in specific journals. We finally conclude by giving some outlook on future directions of this field.  相似文献   

14.
15.
New materials have significant impact on the development of new methods and instrumentation for chemical analysis. From the discovery of carbon nanotubes in 1991, single and multi-walled carbon nanotubes – due to their high adsorption and desorption capacities – have been employed as sorption substrates in solid-phase extraction for the preconcentration of metal species from diverse matrices. Looking for successive improvements in sensitivity and selectivity, in the past few years, carbon nanotubes have been utilized as sorbents for solid phase extraction in three different ways: like as-grown, oxidized and functionalized nanotubes. In the present paper, an overview of the recent trends in the use of carbon nanotubes for solid phase extraction of metal species in environmental, biological and food samples is presented. The determination procedures involved the adsorption of metals on the nanotube surface, their quantitative desorption and subsequent measurement by means of atomic spectrometric techniques such as flame atomic absorption spectrometry, electrothermal atomic absorption spectrometry or inductively coupled plasma atomic emission spectrometry/mass spectrometry, among others. Synthesis, purification and types of carbon nanotubes, as well as the diverse chemical and physical strategies for their functionalization are described. Based on 140 references, the performance and general properties of the applications of solid phase extraction based on carbon nanotubes for metal species atomic spectrometric determination are discussed.  相似文献   

16.
In the present paper, a critical overview of the most commonly used techniques for the characterization and the determination of carbon nanotubes (CNTs) is given on the basis of 170 references (2000–2014). The analytical techniques used for CNT characterization (including microscopic and diffraction, spectroscopic, thermal and separation techniques) are classified, described, and illustrated with applied examples. Furthermore, the performance of sampling procedures as well as the available methods for the determination of CNTs in real biological and environmental samples are reviewed and discussed according to their analytical characteristics. In addition, future trends and perspectives in this field of work are critically presented.  相似文献   

17.
18.
Selenium is an essential element for human health. It has been recognized as an antioxidant and chemopreventive agent in cancer. Selenium is known to develop its biological activity via selenocysteine residue in the catalytically active centre of selenoproteins. The main source of selenium in human beings is the diet. However, in several regions of the world the content of selenium in diet has been estimated insufficient for a correct expression of the proteins. The beneficial effects of selenium on human health are strongly dependent on its chemical form and concentration. This review critically evaluated the state-of-the art of selenium speciation in biological matrices mainly focused in nutritional and food products. Besides the number of publications related to selenium speciation, isolation and accurate characterization and quantification of selenium species is still a challenge. Hyphenated techniques based on coupling chromatography separation with inductively coupled plasma spectrometry (ICP-MS) and its combination with molecular mass spectrometry (ESI-MS, ESI-MS-MS and MALDI-TOF) and isotopic dilution allow identification, quantification and structural characterization of selenium species. Particular attention is paid in the development of Se-enriched food and nutritional products and how the application of the techniques mentioned above is mandatory to get reliable results on selenium metabolisms in these particular matrices.  相似文献   

19.
During the last years (2000–2014), many publications concerning the forensic analysis of questioned documents have been published, and new techniques and methodologies are nowadays employed to overcome forensic caseworks. This article reviews a comprehensive collection of the works focused on this issue, including dating studies, the analysis of inks from pens and printers, the analysis of paper, the analysis of other samples related to questioned documents and studies on intersecting lines. These sections highlight the most relevant analytical studies by a wide range of analytical techniques. Separation and spectrometric techniques are critically discussed and compared, emphasizing the advantages and disadvantages of each one. Finally, concluding remarks on the research published are included.  相似文献   

20.
Liquid phase microextraction applications in food analysis   总被引:2,自引:0,他引:2  
Over the last years, liquid-phase microextraction (LPME) in its different application modes (single drop microextraction, dispersive liquid-liquid microextraction and hollow fiber-LPME) has been increasingly applied for the extraction of both inorganic and organic analytes from different matrices. Its advantages over conventional extraction procedures (simplicity, effectiveness, rapidity and low consumption of organic solvents) has also attracted its application in the complex food analysis field, in which it has clearly provided good and challenging results. A comprehensive review dealing with those articles published since its introduction till the end of March 2011 is presented, offering also a critical vision of the analytical potential of LPME for the analysis of foods.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号