Trace amounts of inorganic mercury (Hg2+) and methylmercury cations (MeHg2+) were adsorbed quantitatively from acidic aqueous solution onto a column packed with immobilized dithizone on microcrystalline naphthalene. The trapped mercury was eluted with 10 ml of 7 mol L–1 hydrochloric acid solution. The Hg2+ was then directly reduced with tin (II) chloride, and volatilized mercury was determined by cold vapor atomic absorption spectrometry (CVAAS). Total mercury (Hgt) was determined after decomposition of MeHg+ into Hg2+. Hg2+ and MeHg+ cations were completely recovered from the water with a preconcentration factor of 200. The relative standard deviation obtained for eight replicate determinations at a concentration of 0.3 g L–1 was 1.8%. The procedure was applied to analysis of water samples, and the accuracy was assessed via recovery experiment.  相似文献   

2.
A simplified micelle-mediated extraction methodology for the preconcentration of ultratrace levels of cadmium as a prior step to its determination by cold vapor atomic absorption spectrometry (CV-AAS) has been developed. The methodology is based on the cloud point extraction (CPE) of cadmium at pH 8 by using the non-ionic surfactant polyethyleneglycolmono-p-nonylphenylether (PONPE 7.5) without adding any chelating agent. Cadmium cold vapor was generated from 2 ml of the extracted surfactant-rich phase by means of sodium tetrahydroborate (3%, w/v) as a reducing agent and hydrochloric acid (0.2 mol l−1) as a carrier solution. Several important variables that affect the cloud point extraction and cold vapor cadmium generation efficiency were investigated and optimized. The preconcentration of only 50 ml of solution in the presence of 0.06% (v/v) PONPE 7.5 gives an enhancement factor of 62. The calibration graph using the preconcentration system was linear in the range of 4-100 ng l−1 with a correlation coefficient of 0.9992. Detection limit (3 s) obtained in the optimal conditions was 0.56 ng l−1. The relative standard deviation (R.S.D.) for six replicate determinations at 20 ng l−1 Cd level was 3.2%. The proposed method was successfully applied to the ultratrace determination of cadmium in water samples.  相似文献   

3.
A simple and accurate method has been developed for the determination of total mercury in environmental and biological samples. The method utilises an off-line microwave digestion stage followed by analysis using a flow injection system with detection by cold vapour atomic absorption spectrometry.

The method has been validated using two certified reference materials (DORM-1 dogfish and MESS-2 estuarine sediment) and the results agreed well with the certified values. A detection limit of 0.2 ng g−1 Hg was obtained and no significant interference was observed. The method was finally applied to the determination of mercury in river sediments and canned tuna fish, and gave results in the range 0.1–3.0 mg kg−1.  相似文献   


4.
Method development for the pre-concentration of mercury in human hair, dogfish liver and dogfish muscle samples using cloud-point extraction and cold vapor atomic absorption spectrometry is demonstrated. Before the extraction, the samples were submitted to microwave-assisted digestion in a mixture of H2O2 and HNO3. Cloud point extraction was carried out using 0.5% (m/v) ammonium O,O-diethyldithiophosphate (DDTP) as the chelating agent and 0.3% (m/v) Triton X-114 as the non-ionic surfactant. Phase separation was induced after the addition of Na2SO4 to a final concentration of 0.2 mol L−1. Aliquots of the final extract were transferred to PTFE tubes and NaBH4 and HCl were added. The mercury vapor was driven to a non-heated quartz tube for measuring the absorbance. The results obtained with salt-induced phase separation were in good agreement with the certified values at a 95% confidence level. An enrichment factor of 10 allowed a detection limit of 0.4 ng g−1 to be obtained, which demonstrates the high sensitivity of the proposed procedure for the determination of mercury at trace levels.  相似文献   

5.
A method for organic, inorganic and total mercury determination in fish tissue has been developed using chemical vapor generation and collection of mercury vapor on a gold gauze inside a graphite tube and further atomization by electrothermal atomic absorption spectrometry. After drying and cryogenic grinding, potassium bromide and hydrochloric acid solution (1 mol L− 1 KBr in 6 mol L− 1 HCl) was added to the samples. After centrifugation, total mercury was determined in the supernatant. Organomercury compounds were selectively extracted from KBr solution using chloroform and the resultant solution was back extracted with 1% m/v L-cysteine. This solution was used for organic Hg determination. Inorganic Hg remaining in KBr solution was directly determined by chemical vapor generation electrothermal atomic absorption spectrometry. Mercury vapor generation from extracts was performed using 1 mol L− 1 HCl and 2.5% m/v NaBH4 solutions and a batch chemical vapor generation system. Mercury vapor was collected on the gold gauze heated resistively at 80 °C and the atomization temperature was set at 650 °C. The selectivity of extraction was evaluated using liquid chromatography coupled to chemical vapor generation and determination by inductively coupled plasma mass spectrometry. The proposed method was applied for mercury analysis in shark, croaker and tuna fish tissues. Certified reference materials were used to check accuracy and the agreement was better than 95%. The characteristic mass was 60 pg and method limits of detection were 5, 1 and 1 ng g− 1 for organic, inorganic and total mercury, respectively. With the proposed method it was possible to analyze up to 2, 2 and 6 samples per hour for organic, inorganic and total Hg determination, respectively.  相似文献   

6.
Generation of mercury vapor by ultraviolet irradiation of mercury solutions in low molecular weight organic acid solutions prior to measurement by Atomic Absorption Spectrometry is a cheap, simple and green method for determination of trace concentrations of mercury. In this work mercury vapor generated by ultraviolet photolysis was trapped onto a palladium coated graphite furnace significantly improving the detection limit of the method. The system was optimized and a detection limit of 0.12 µg L− 1 (compared to 2.1 µg L− 1 for a previously reported system in the absence of trapping) with a precision of 11% for a 10 µg L− 1 mercury standard (RSD, N = 5).  相似文献   

7.
A new room temperature ionic liquid 1-butyl-3-trimethylsilylimidazolium hexafluorophosphate abbreviated as [C4tmsim][PF6] was synthesized and developed as a novel medium for liquid/liquid extraction of inorganic mercury in this work. Under optimal condition, o-carboxyphenyldiazoamino-p-azobenzene abbreviated as CDAA reacted with inorganic mercury to form a neutral Hg-CDAA complex, the complex was rapidly extracted into ionic liquid phase. After back-extracting into aqueous phase with sulfide sodium solution, the mercury concentration was detected by cold vapor atomic absorption spectrometry. The extraction and back-extraction efficiencies were 99.9 and 100.1% for 5.0 μg L−1 standard mercury in 1000 mL of water solution, respectively. The detection limit, calculated using three times the standard error of estimate of the calibration graph, is 0.01 ng of mercury per milliliter water sample. The proposed method has been used to the determination of trace inorganic mercury in natural water with satisfactory results. Moreover, Zeta potential and surface tension of [C4tmsim][PF6] solution were measured and applied to explain the extraction mechanism of [C4tmsim][PF6] system.  相似文献   

8.
9.
为了寻求一种更加适宜测定土壤中汞含量的测试方法,将检出限低、精密度高的冷原子吸收光谱法与便捷、高效的王水水浴消解土壤处理方式相结合,建立了王水消解-冷原子吸收光谱法测定土壤中汞。通过测定方法的线性相关性、方法检出限、准确度、精密度、加标回收率,并与原子荧光光谱法进行对比实验来评价该方法的有效性。王水消解-冷原子吸收光谱法在汞质量浓度0.0~1.0μg/L范围内线性良好,相关系数可以达到0.9999,方法检出限为0.00075 mg/kg,土壤标准样品测试的相对标准偏差为4.0%~10.7%,实际样品加标回收率分别为93%~104%。采用原子荧光光谱法进行对比测试,原子荧光光谱法的方法检出限为0.0025 mg/kg,相对标准偏差为4.8%~13.5%,加标回收率为104%~107%。结果表明,对于王水水浴消解土壤的方法不仅适用于原子荧光光谱法测定汞含量,同样可以应用于冷原子吸收光谱法中。所建立的王水消解-冷原子吸收光谱法具有更低的检出限,更优的准确度和精密度,有利于提高土壤样品测试的工作效率,值得推广。  相似文献   

10.
为了寻求一种更加适宜测定土壤中汞含量的测试方法,将检出限低、精密度高的冷原子吸收光谱法与便捷、高效的王水水浴消解土壤处理方式相结合,建立了王水消解-冷原子吸收光谱法测定土壤中汞。通过测定方法的线性相关性、方法检出限、准确度、精密度、加标回收率,并与原子荧光光谱法进行对比实验来评价该方法的有效性。王水消解-冷原子吸收光谱法在汞质量浓度0.0~1.0μg/L范围内线性良好,相关系数可以达到0.999 9,方法检出限为0.000 75mg/kg,土壤标准样品测试的相对标准偏差为4.0%~10.7%,实际样品加标回收率分别为93%~104%。采用原子荧光光谱法进行对比测试,原子荧光光谱法的方法检出限为0.002 5 mg/kg,相对标准偏差为4.8%~13.5%,加标回收率为104%~107%。结果表明,对于王水水浴消解土壤的方法不仅适用于原子荧光光谱法测定汞含量,同样可以应用于冷原子吸收光谱法中。所建立的王水消解-冷原子吸收光谱法具有更低的检出限,更优的准确度和精密度,有利于提高土壤样品测试的工作效率,值得推广。  相似文献   

11.
A simple and robust time-based on-line sequential injection system for trace mercury determination via cold vapour atomic absorption spectrometry (CVAAS), employing a new integrated gas-liquid separator (GLS), which in parallel operates as reactor, was developed. Sample and reductant are sequentially loaded into the GLS while an argon flow delivers the released mercury vapour through the atomic absorption cell. The proposed method is characterized by the ability of successfully managing variable sample volume up to 30 ml in order to achieve high sensitivity. For 20 ml sample volume, the sampling frequency is 25 h−1. The calibration curve is linear over the concentration range 0.05-5.0 μg l−1 of Hg(II), the detection limit is cL = 0.02 μg l−1, and the relative standard deviation is sr = 2.6% at 1.0 μg l−1 Hg(II) level. The performance of the proposed method was evaluated by analyzing certified reference material and applied to the analysis of natural waters and biological samples.  相似文献   

12.
A new method based on ultrasonic slurry sampling atomic absorption spectrometry (AAS) was established for the determination of trace mercury in geological samples by use of recently developed mercury cold vapor generation using formic acid under ultraviolet (UV) irradiation. The generated mercury cold vapor was rapidly separated from the matrix and swept into a T-tube for the measurement of atomic absorbance. Under the optimal experimental conditions, up to 1000-fold of Cu(II), Co(II), Ni(II), Cr(VI), Mn(II), Fe(III), and Zn(II) caused no significant interference with the determination of 50 μg L−1 Hg. The limit of detection at sub-ppb level was obtained for mercury. The method was applied to the determination of mercury in geological samples with satisfactory results. Correspondence: Xiandeng Hou, College of Chemistry, Sichuan University, Chengdu, Sichuan 610064, China  相似文献   

13.
A continuously operating monitoring method for total mercury at sub-ng/ml level in environmental and biological samples by cold vapour atomic-absorption spectrometry with NaBH4 as a reductant was developed. The mercury vapour generator and absorption cell closed-end by quartz were used in this study. The detection limit (S/N = 3) and relative standard deviation of 12 determinations of 10 ng/ml Hg(II) were 0.11 ng/ml and 1.1%, respectively. The range of standard calibration curve was 0–50 ng/ml Hg, The proposed method was successfully applied to the completely continuous monitoring of total mercury in waste water, sediments and pork liver.  相似文献   

14.
Bendl RF  Madden JT  Regan AL  Fitzgerald N 《Talanta》2006,68(4):1366-1370
A method for the determination of mercury via UV photoreduction has been investigated. Mercury vapor was generated by the reduction of mercury species in an acetic acid solution using UV radiation. Detection of the volatile mercury was accomplished by atomic absorption spectrometry. An optimized system was found to provide a detection limit (defined as the concentration giving a signal equal to three times the standard deviation of the blank) of 2.1 μg L−1 with a precision of 2.9% relative standard deviation (n = 8) for a 500 μg L−1 mercury standard. The effect of various metal ions on the mercury signal was investigated and the method validated with a NRCC certified dogfish liver material (DOLT-3) using the method of standard additions. A reaction pathway is hypothesized for UV photoreduction.  相似文献   

15.
The present work investigates the use of a multipath cell atomic absorption mercury detector for mercury speciation analysis in a hyphenated high performance liquid chromatography assembly. The multipath absorption cell multiplies the optical path while energy losses are compensated by a very intense primary source. Zeeman-effect background correction compensates for non-specific absorption. For the separation step, the mobile phase consisted in a 0.010% m/v mercaptoethanol solution in 5% methanol (pH = 5), a C18 column was used as stationary phase, and post column treatment was performed by UV irradiation (60 °C, 13 W). The eluate was then merged with 3 mol L− 1 HCl, reduction was performed by a NaBH4 solution, and the Hg vapor formed was separated at the gas–liquid separator and carried through a desiccant membrane to the detector. The detector was easily attached to the system, since an external gas flow to the gas–liquid separator was provided. A multivariate approach was used to optimize the procedure and peak area was used for measurement. Instrumental limits of detection of 0.05 µg L− 1 were obtained for ionic (Hg2+) and HgCH3+, for an injection volume of 200 µL. The multipath atomic absorption spectrometer proved to be a competitive mercury detector in hyphenated systems in relation to the most commonly used atomic fluorescence and inductively coupled plasma mass spectrometric detectors. Preliminary application studies were performed for the determination of methyl mercury in sediments.  相似文献   

16.
de Jesus A  Silva MM  Vale MG 《Talanta》2008,74(5):1378-1384
A new method for F AAS determination of sodium and potassium in biodiesel using water-in-oil microemulsion as sample preparation is proposed. The method was investigated for biodiesel produced from different sources, as soybean, castor and sunflower oil and animal fat and was also applied for vegetable oils. The optimized condition for microemulsion formation was 57.6% (w/w) of n-pentanol, 20% (w/w) of biodiesel or vegetable oil, 14.4% (w/w) of Triton X-100 and 8% (w/w) of water (aqueous standard of KCl or NaCl in/or diluted HNO3). The optimized instrumental parameters were: aspiration rate of 2 mL min−1 and the flame composition of 0.131 of C2H2/air ratio. For comparison purpose, the determination of sodium and potassium were also carried out according to European norms (EN 14108 and EN 14109, respectively). These norms are applied for determination of sodium and potassium in fatty acid methylic ester samples and consist in the sample dilution using organic solvent and determination by F AAS. The stability of microemulsified aqueous standards and samples was investigated and it was found to be stable for at least 3 days while the organic standard diluted with xylene showed a decrease around of 15% in the analytical signal in 1 h. The limits of detection were 0.1 μg g−1 and 0.06 μg g−1 and the obtained characteristic concentrations were 25 μg L−1 and 28 μg L−1 for sodium and potassium, respectively. The proposed method presented two times better limits of detection and better precision (0.4–1.0%) when compared with the dilution technique (1.5–4.5%). The accuracy of the method was evaluated through recovery tests and comparison with the results obtained by dilution technique. The recoveries ranged from 95% to 115% for biodiesel and 90% to 115% for vegetable oil samples. Comparison between the results obtained for biodiesel by both methods showed no significant differences at the 95% confidence level according to a Student's t-test. This study shows that the proposed method based on microemulsion as sample preparation can be applied as an efficient alternative for sodium and potassium determination in biodiesel samples.  相似文献   

17.
The determination of osmium in waste water by electrothermal atomic absorption spectrometry (AAS) with a graphite furnace atomiser has been investigated. The atomisation characteristics of osmium on the atomiser were found to result in optimal ashing and atomisation temperatures of 300–500 and 3180 °C, respectively.The characteristic mass (the mass of element giving 0.0044 abs.) of osmium after optimization was found to be 1.6ng, which is better than obtained with flame AAS and ultraviolet/visible (UV) absorption spectrophotometry. The detection limit (s/n = 3) was 3.6ng (or 0.36 (g ml–1). The relative std. deviation obtained with graphite furnace AAS was 3.0%.The interference caused by large amounts of common cations and anions in waste water were evaluated and thiourea as matrix modifier was shown to be able to eliminate many interferences. The recovery of osmium spiked in waste water was considered almost satisfactory at the 1–50 g ml–1 range and the results were shown to well agree with the analytical values obtained by UV absorption spectrophotometry.  相似文献   

18.
An addition of sodium hypochlorite solution effectively eliminated the interference by sulfide in the cold vapor atomic absorption spectrometric determination of mercury using tin(II) reduction in alkaline medium. Mercury ranging from 0.01 to 0.5 μg could be determined within ±10% error in 100 mL of sample solution containing 10 mg of sulfide by the addition of 1 mL of 10.4%(w/v) sodium hypochlorite solution. The proposed method is rapid (5 min per determination) and has good reproducibility (3.0%).  相似文献   

19.
An addition of sodium hypochlorite solution effectively eliminated the interference by sulfide in the cold vapor atomic absorption spectrometric determination of mercury using tin(II) reduction in alkaline medium. Mercury ranging from 0.01 to 0.5 μg could be determined within ±10% error in 100 mL of sample solution containing 10 mg of sulfide by the addition of 1 mL of 10.4%(w/v) sodium hypochlorite solution. The proposed method is rapid (5 min per determination) and has good reproducibility (3.0%). Received: 20 May 1998 / Revised: 7 July 1998 / Accepted: 10 July 1998  相似文献   

20.
A novel method for preconcentration of methylmercury and inorganic mercury from water samples was developed involving the determination of ng l−1 levels of analytes retained on the silica C18 solid sorbent, previous complexation with ammonium pyrrolidine dithiocarbamate (APDC), by slurry sampling cold vapor atomic absorption spectrometry (SS-CVAAS) in a flow injection (FI) system. Several variables were optimized affecting either the retention of both mercury species, such as APDC concentration, silica C18 amount, agitation times, or their determination, including hydrochloric acid concentration in the suspension medium, peristaltic pump speed and argon flow-rate. A Plackett-Burman saturated factorial design permitted to differentiate the influential parameters on the preconcentration efficiency, which were after optimized by the sequential simplex method. The contact time between mercury containing solution and APDC, required to reach an efficient sorption, was decreased from 26 to 3 min by the use of sonication stirring instead of magnetic stirring. The use of 1 mol dm−3 hydrochloric acid suspension medium and 0.75% (m/v) sodium borohydride reducing agent permitted the selective determination of methylmercury. The combination of 5 mol dm−3 hydrochloric acid and 10−4% (m/v) sodium borohydride was used for the selective determination of inorganic mercury. The detection limits achieved for methylmercury and inorganic mercury determination under optimum conditions were 0.96 and 0.25 ng l−1, respectively. The reliability of the proposed method for the determination of both mercury species in waters was checked by the analysis of samples spiked with known concentrations of methylmercury and inorganic mercury; quantitative recoveries were obtained.  相似文献   