首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A new multisyringe flow injection system for total inorganic selenium determination by hydride generation-atomic fluorescence spectrometry (HGAFS) has been proposed. The flow methodology is based on the simultaneous injection of sample in the acid media (50% HCl), a reducing sodium tetrahydroborate solution (0.18%) and a solution of hydrochloric acid (50%) which are dispensed into a gas-liquid separation cell by using a multisyringe burette coupled with one multiport selection valve. The usage of the time-based injection increases the sample throughput and provides precise known volumes of sample. The hydride of selenium is delivered into the flame of an atomic fluorescence spectrometer by means of an argon flow. A hydrogen flow has been used to support the flame.The technique can be applied over a wide range of concentrations of selenium between 0.1 and 3.5 μg l−1 with good repeatability (relative standard deviation (R.S.D.) values 4.6-7% for 1 μg l−1 of Se). The detection limit of the developed technique (3σb/S) was 0.01 μg l−1. A sample throughput was 28 samples per hour (84 injections). The multisyringe technique has been validated by means of reference solid (sea lettuce) and water (hard drinking water) materials with good agreement with certified values. The analytical features were compared with those obtained by using of the commercial flow injection analysis (FIA) system. The proposed method provides a higher sampling frequency and a significant reduction of reagent and sample consumption in front the flow injection application.  相似文献   

2.
A solid sampling flame furnace atomic absorption spectrometry (SS-FF-AAS) system was developed for Mn and Ni determination in petroleum coke. The proposed system for solid sampling was a quartz cell with two perpendicular tubes (T-shaped tubes), positioned above the burner. Manganese and Ni determination was made using an atomic absorption spectrometer with deuterium background corrector, air-acetylene flame and a single slit burner. Powdered samples of coke were introduced as pellets (up to 62 mg) into the quartz cell with a movable hollow quartz piston. When the sample pellet reached the end of quartz cell (T-connection), in the presence of a constant oxygen flow, it quickly burned and the combustion products were transferred to the upper slit tube where the atomic absorption process occurs. Calibration was possible using aqueous reference solutions applied directly on high purity graphite pellets. Results obtained for Mn and Ni using the proposed SS-FF-AAS system were compared to those obtained by inductively coupled plasma optical emission spectrometry (ICP OES) and inductively coupled plasma mass spectrometry (ICP-MS) after sample decomposition by high pressure microwave assisted acid digestion and also by microwave induced combustion. Agreement better than 96% was obtained for both methods employing a previous step of sample digestion (ICP OES and ICP-MS) and by SS-FF-AAS. Accuracy was evaluated using certified reference materials and also recovery tests. The relative standard deviation was lower than 9% for both analytes. The characteristic mass was 18.3 and 14.7 ng and the limit of detection was 0.6 and 0.8 µg g− 1 for Mn and Ni, respectively. The proposed SS-FF-AAS system can be applied for Mn and Ni determination in petroleum coke, combining a relatively high sample throughput (9 determinations per h), and a suitable precision and accuracy.  相似文献   

3.
A software-controlled time-based multisyringe flow-injection system for total inorganic arsenic determination by hydride generation atomic fluorescence spectrometry (HGAFS) has been developed. By using a multisyringe burette coupled with one multiport selection valve, the time-based injection provides precise known volumes of sample, a reducing sodium tetrahydroborate solution and a pre-reducing solution which are dispensed into a gas-liquid separation cell. An argon flow delivers the arsine into the flame of an atomic fluorescence spectrometer. A hydrogen flow has been used to support the flame.Linear calibration graphs for arsenic concentrations between 0.25 and 12 μg l−1 were obtained. The detection limit of the proposed technique (3σb/S) was 0.07 μg l−1. A sample throughput of 36 samples/h (108 injections) has been achieved. The proposed technique has been validated by means of reference solid and water materials with good agreement with the certified values. This method was compared with those reported in previous sequential injection analysis (SIA) and flow-injection analysis (FIA) systems. The proposed method offers a number of advantages in front the usual AFS applications, which are mainly a higher sampling frequency and a significant reduction in reagent consumption.  相似文献   

4.
Leal LO  Forteza R  Cerdà V 《Talanta》2006,69(2):500-508
In this study, a new technique by hydride generation-atomic fluorescence spectrometry (HG-AFS) for determination and speciation of inorganic arsenic using multisyringe flow injection analysis (MSFIA) is reported. The hydride (arsine) was generated by injecting precise known volumes of sample, a reducing sodium tetrahydroborate solution (0.2%), hydrochloric acid (6 M) and a pre-reducing solution (potassium iodide 10% and ascorbic acid 0.2%) to the system using a multisyringe burette coupled with one multi-port selection valve. This solution is used to pre-reduce As(V) to As(III), when the task is to speciate As(III) and As(V). As(V) is determined by the difference between total inorganic arsenic and As(III). The reagents are dispensed into a gas-liquid separation cell. An argon flow delivers the arsine into the flame of an atomic fluorescence spectrometer. A hydrogen flow has been used to support the flame. Nitrogen has been employed as a drier gas (Fig. 1).Several variables such as sample and reagents volumes, flow rates and reagent concentrations were investigated in detail. A linear calibration graph was obtained for arsenic determination between 0.1 and 3 μg l−1. The detection limit of the proposed technique (3σb/S) was 0.05 μg l−1. The relative standard deviation (R.S.D.) of As at 1 μg l−1 was 4.4 % (n = 15). A sample throughput of 10 samples per hour was achieved. This technique was validated by means of reference solid and water materials with good agreement with the certified values. Satisfactory results for speciation of As(III) and As(V) by means of the developed technique were obtained.  相似文献   

5.
A new analytical procedure for determination of inorganic antimony and speciation of antimony(III) and antimony(V) is presented. For this purpose, a software-controlled time-based multisyringe flow injection system, which contains a multisyringe burette provided with a multi-port selection valve, was developed. Hydride generation-atomic fluorescence spectrometry was used as a detection technique. A 0.3% (w/v) reducing sodium tetrahydroborate solution, hydrochloric acid (2 M), an antimony solution and a pre-reducing solution of 10% (w/v) KI and 0.3% (w/v) ascorbic acid are dispensed simultaneously into a gas-liquid separation cell with further propulsion of the reaction product into the flame of an atomic fluorescence spectrometer using argon flow. A hydrogen flow was employed to support the flame.The linear range and the detection limit (3sb/S) of the proposed technique were 0.2-5.6 μg l−1 and 0.08 μg l−1, respectively. A sample throughput of 18 samples per hour (corresponding to 80 injections per hour) was achieved. The relative standard deviation for 18 independent measurements was 4.6%. This technique was validated by means of reference solid and water materials with good agreement with the certified values. Satisfactory results for speciation of Sb(III) and Sb(V) by means of the developed technique were obtained.  相似文献   

6.
The development of a slurry sampling method for the determination of calcium, copper, iron, magnesium and zinc in fish tissue samples by flame atomic absorption spectrometry is described. In comparison with microwave-assisted digestion, the proposed method is simple, requires short time and eliminates total sample dissolution before analysis. Suspension medium was optimized for each analyte to obtain quantitative recoveries from fish tissue samples without matrix interferences. Nevertheless, iron recoveries higher than 46% were not found. Treatment of samples slurried in nitric acid by microwave irradiation for 15-30 s at 75-285 W permitted to achieve efficient recoveries for calcium, iron, magnesium and zinc. Further improvement in the matrix effects for iron determination was accomplished by the use of an additional step of short microwave-assisted suspension treatment. However, standard addition method was required for calcium and copper determination, being necessary hydrochloric acid as suspension medium for the last one. Although copper could not be determined in the certified reference material using microwave-assisted digestion, the accuracy of the slurry sampling method was verified for all the investigated analytes. Detection limits were 22.8 ± 8.0, 0.884 ± 0.092, 5.07 ± 0.76, 35.5 ± 0.7 and 1.17 ± 0.04 μg g−1 for calcium, copper, iron, magnesium and zinc, respectively. The standard deviations obtained using slurry sampling method and microwave-assisted digestion were not significantly different, and the mean relative standard deviation of the over-all method (n = 3) of the slurry sampling method for different concentration levels was below 12%.  相似文献   

7.
Dutra RL  Maltez HF  Carasek E 《Talanta》2006,69(2):488-493
An on-line preconcentration system for zinc determination in 24-h urine, blood plasma and erythrocyte matrices by flame atomic absorption spectrometry (FAAS) was used. This procedure was based on adsorption of Zn(II) ions onto a minicolumn filled with silica gel, chemically modified with niobium(V) oxide (Nb2O5-SiO2). The determination of the optimum conditions for Zn(II) preconcentration was done using two-level full factorial and Doehlert designs. In the optimization procedure, four variables (sample pH, eluent concentration, sample flow rate and eluent flow rate) were investigated. The results obtained from the full factorial design demonstrated that the sample pH and sample flow rate variables, and their interactions, were statistically significant. A Doehlert matrix was used in order to determine the optimum conditions for the sample pH and sample flow rate. The optimized conditions for sample pH and flow rate sampling were 6.6 and 7.1 ml min−1, respectively, to obtain the maximum Zn(II) preconcentration and determination in the biological samples studied. Parameters of analytical curve, precision, effect of other ions in the proposed system and accuracy were achieved to assess the proposed method. The accuracy was confirmed by analysis of certified reference materials (urine Seronorm™ Trace Elements) and recovery tests in blood plasma and erythrocyte samples. Detection limit (3σ/S) of 0.77 μg l−1, precision (calculated as relative standard deviation) of 1.5% for Zn(II) concentration of 10 μg l−1 (n = 7) and a sampling frequency of 27 samples/h were obtained from the proposed system.  相似文献   

8.
This article describes the development by response surface methodology (RSM) of a procedure for iron, zinc and manganese determination by flame atomic absorption spectrometry (FAAS) in food samples after digestion employing a focussed microwave system. A Doehlert matrix was used to find optimal conditions for the procedure through response surface study. Three variables (irradiation power and time and composition of oxidant solution—HNO3 + H2O2) were regarded as factors in the optimization study. The working conditions were established as a compromise between optimum values found for each analyte taking into consideration the robustness of the procedure. These values were 12 min, 260 W and 42% (v/v) for irradiation time, irradiation power and percent of H2O2 in solution, respectively. The accuracy of the optimized procedure was evaluated by analysis of certified reference materials and by comparison with a well-established closed vessel microwave dissolution methodology.  相似文献   

9.
A slurry sampling inductively coupled plasma mass spectrometry (ICP-MS) method has been developed for the determination of Ge, As, Cd, Sb, Hg and Bi in cosmetic lotions using flow injection (FI) vapor generation (VG) as the sample introduction system. A slurry containing 2% m/v lotion, 2% m/v thiourea, 0.05% m/v l-cysteine, 0.5 μg mL−1 Co(II), 0.1% m/v Triton X-100 and 1.2% v/v HCl was injected into a VG-ICP-MS system for the determination of Ge, As, Cd, Sb, Hg and Bi without dissolution and mineralization. Because the sensitivities of the analytes in the slurry and that of aqueous solution were quite different, an isotope dilution method and a standard addition method were used for the determination. This method has been validated by the determination of Ge, As, Cd, Sb, Hg and Bi in GBW09305 Cosmetic (Cream) reference material. The method was also applied for the determination of Ge, As, Cd, Sb, Hg and Bi in three cosmetic lotion samples obtained locally. The analysis results of the reference material agreed with the certified value and/or ETV-ICP-MS results. The detection limit estimated from the standard addition curve was 0.025, 0.1, 0.2, 0.1, 0.15, and 0.03 ng  g−1 for Ge, As, Cd, Sb, Hg and Bi, respectively, in original cosmetic lotion sample.  相似文献   

10.
A slurry sampling method for the simultaneous determination of hydride forming (As, Bi, Ge, Sb, Se, Sn) and Hg and non-hydride forming (Ca, Fe, Mg, Mn, Zn) elements, without total sample digestion has been developed using the commercial dual-mode sample introduction system (MSIS) coupled with microwave induced plasma optical emission spectrometry (MIP-OES) from biological and environmental reference materials and real samples. The main advantage of this system is its simultaneous determination of elements that form volatile vapor species and elements that do not, without any instrumental changes. Optimization of reaction, nebulization and instrumental conditions was performed to characterize the new system. Slurry concentration up to 4% m/v (particles < 100 μm) prepared in 10% HNO3 containing 100 μL of decanol, by application of ultrasonic agitation, was used with calibration by the standard addition technique. An ultrasonic probe was used to homogenize the slurry in the quartz cup just before its introduction into the reaction/nebulization system; the multimode sample introduction system (MSIS) combines the benefits of nebulization and vapor generation in a single device. Detection limits (LOD, 3σblank, peak area) of 0.07, 0.29, 0.25, 0.10, 0.12, 0.14, 0.11, 0.28, 0.42, 0.02, 0.21 and 0.34 μg g− 1 were obtained for As, Bi, Ge, Sb, Se, Sn, Hg, Ca, Fe, Mg, Mn and Zn, respectively. The relative standard deviations were ca. 10%, adequate for slurry analysis. To test the accuracy, six certified reference materials were analyzed with the analyte concentrations mostly in the μg g− 1 level. Measured concentrations are in satisfactory agreement with certified values for the biological reference materials (LUTS-1, DOLT-2) and environmental reference materials (PACS-1, GWB 07302, NIST 2710, NBS 1633b), all adequate for slurry sampling. The method was successfully applied to the determination of the elements in real samples (coal fly ash, lake sediment, sewage). The method requires small amounts of reagents and reduces contamination and losses.  相似文献   

11.
In this study a method for the determination of low concentrations of silver in waters using solid-phase extraction with a flow injection analysis system and detection by flame atomic absorption spectrometry (FAAS) was developed. Moringa oleifera seeds were used as a biosorbent material. Chemical and flow variables of the on-line preconcentration system such as sample pH and flow rate, preconcentration time, eluent concentration and sorbent mass were studied. The optimum preconcentration conditions were obtained using sample pH in the range of 6.0-8.0, preconcentration time of 4 min at a flow rate of 3.5 mL min− 1, 0.5 mol L− 1 HNO3 eluent at a flow rate of 4.5 mL min− 1 and 35 mg of sorbent mass. With the optimized conditions, the preconcentration factor, precision, detection limit and sample throughput were estimated as 35 (for preconcentration of 14 mL sample), 3.8% (5.0 μg L− 1, n = 7), 0.22 μg L− 1 and 12 samples per hour, respectively. The developed method was successfully applied to mineral water and tap water, and accuracy was assessed through analysis of a certified reference material for water (APS-1071 NIST) and recovery tests, with recovery ranging from 94 to 101%.  相似文献   

12.
Ibrahim S.I. Adam 《Talanta》2009,77(3):1160-1164
A newly simple flow injection wetting-film extraction system coupled to flame atomic absorption spectrometry (FAAS) has been developed for trace amount of cadmium determination. The sample was mixed on-line with sodium diethyl dithiocarbamate and the produced non-charged Cd(II)-diethyl dithiocarbamate (DDTC) chelate complex was extracted on the thin film of diisobutyl ketone (DIBK) on the inner wall of the PTFE extraction coil. The wetting-film with the extracted analyte was then eluted by a segment of the cover solvent, and transported directly to the FAAS for evaluation. All the important chemical and flow parameters were optimized. Under the optimized conditions an enhancement factor of 35, a sample frequency of 22 h−1 and a detection limit of cL = 0.7 μg l−1 Cd(II) were obtained for 60 s preconcentration time. The calibration curve was linear over the concentration range 1.5-45.0 μg l−1 Cd(II) and the relative standard deviation, R.S.D. (n = 10) was 3.9%, at 10.0 μg l−1 concentration level. The developed method was successfully applied to cadmium determination in a variety of environmental water samples as well as waste-water sample.  相似文献   

13.
A slurry sampling hydride generation (SS-HG) method for the simultaneous determination of hydride forming elements (As, Sb, Se, Sn) and Hg, without total sample digestion, has been developed using batch mode generation system coupled with microwave induced plasma optical emission spectrometry (MIP-OES) from certified biological and environmental reference materials. Slurry concentration up to 3.6% m/v (particles < 80 μm) prepared in 10% HCl containing 100 μl of decanol, by the application of ultrasonic agitation, was used with calibration by the standard addition technique. Harsh conditions were used in the slurry preparation in order to reduce the hydride forming elements to their lower oxidation states, As(III), Sb(III), Se(IV) and Sn(II) and Hg, being reduced to mercury vapor, before reacting with sodium tetrahydroborate. An ultrasonic probe was used to homogenize the slurry in the quartz cup just before its introduction into the reaction vessel. For 10 ml of slurry sample, detection limits (LOD, 3σblank, peak area) of 0.06, 0.08, 0.15, 0.12 and 0.10 μg g− 1 were obtained for As, Sb, Se, Sn and Hg, respectively. The method offers relatively good precision (RSD ranged from 9 to 12%) for slurry analysis. To test the accuracy, three certified reference materials were analyzed with the analyte concentrations mostly in the μg g− 1 level. Measured concentrations are in satisfactory agreement with certified values for the biological reference materials: NRCC LUTS-1 (lobster hepatopancreas), NRCC DOLT-2 (Dogfish Liver) and environmental reference material: NRCC PACS-1 (Marine Sediment), all adequate for slurry sampling. The method requires small amounts of reagents and reduces contamination and losses.  相似文献   

14.
Continuous flow (CF) chemical hydride generation (CHG) and electrochemical hydride generation (ECHG) directly coupled to a novel 40 W, atmospheric pressure, 2.45 GHz microwave microstrip Ar plasma exiting a microstrip wafer has been developed for the emission spectrometric determination of As and Sb using a miniaturized optical fiber spectrometer and a CCD-array detector. The experimental conditions for both procedures were optimized with respect to the relative net intensities of the As I 228.8 nm and Sb I 252.8 nm lines and their signal-to-background intensity ratios. Additionally, the susceptibility to interferences from Cd, Co, Cr, Cu, Fe, Ni, Pb and Zn and other hydride-forming elements in the determination of As and Sb using the CHG and ECHG techniques was investigated in detail. Under the optimized conditions, it was found that ECHG is more prone to interferences compared to CHG. The detection limits (3σ) of As (6 ng mL−1) and Sb (7 ng mL−1) obtained for the ECHG-MSP-OES method are about three times lower than in the case of the CHG-MSP-OES method due to a two-fold lower amount of H2 introduced into the MSP in case of the ECHG, resulting in a better plasma stability and reduced background level. The linearity ranges for both calibration curves to a concentration of up to 5 μg mL−1 and a precision between 2% and 7% (2 μg mL−1 and 0.050 μg mL−1 of As and Sb, respectively) were found for both methods. The developed ECHG-MSP-OES method was validated for As through the analysis of a certified coal fly ash standard reference material (NIST SRM 1633a) after sample dissolution. The derived concentration (140 ± 8 μg g−1) was found to agree well with the certified data (145 ± 15 μg g−1). The method was also successfully applied to the analysis of both a galvanic bath sample, which contained Sb and was spiked with As, and a tap water sample spiked with both analytes. Recovery rates of 99-101% and a Sb concentration of 6.6 μg mL−1 in the galvanic bath sample were revealed. The latter value showed a good agreement with the data obtained from ICP-OES analysis, which was also used for validation purpose.  相似文献   

15.
We developed a flow injection (FI) method for the determination of thiomersal (sodium ethylmercurithiosalicylate, C9H9HgNaO2S) based on the UV/microwave (MW) photochemical, online oxidation of organic mercury, followed by cold vapor generation atomic fluorescence spectrometry (CVG-AFS) detection. Thiomersal was quantitatively converted in the MW/UV process to Hg(II), with a yield of 97 ± 3%. This reaction was followed by the reduction of Hg(II) to Hg(0) performed in a knotted reaction coil with NaBH4 solution, and AFS detection in an Ar/H2 miniaturized flame. The method was linear in the 0.01–2 μg mL−1 range, with a LOD of 0.003 μg mL−1. This method has been applied to the determination of thiomersal in ophthalmic solutions, with recoveries ranging between 97% and 101%. We found a mercury concentration in commercial ophthalmic solutions ranging between 7.5 and 59.0 μg mL−1.  相似文献   

16.
A continuous ultrasound-assisted extraction system connected to a flow injection manifold has been used for the on-line determination of zinc in meat samples by flame atomic absorption spectrometry. An experimental design was used for the optimisation of the continuous manifold. This flow injection methodology allowed a sampling frequency of ca. 80 samples per hour with a relative standard deviation for the whole procedure of 0.3% (for a sample containing 163.6 μg g−1 Zn). The detection limit was 0.6 μg g−1 for a sample amount of 5 mg. Accurate results were obtained by measuring certified reference materials (BCR-186 (pig kidney) and BCR-184 (bovine muscle)). The analytical procedure was applied to different real meat samples with satisfactory results.  相似文献   

17.
A flow injection method with on-line solid sample dissolution was developed for the determination of fluoride in phosphate rock. The fluoride was selectively leached (98-102.4 % recovery) from a 50-mg powdered phosphate rock sample with 0.50 M citric acid. Using the zone sampling technique the fluoride in the buffered leachate was determined by injecting 87 μL into the carrier stream using a fluoride ion-selective electrode detector. The sensing element of the electrode was housed in a home-made sleeve-type flow-through cell. On-line solid sample digestion with 0.50 M citric acid at 55 °C resulted in minimum dissolution of interfering iron and aluminum ions with improved accuracy and calibration linearity. The incorporation of relatively high level of fluoride in the carrier stream (40 μg mL−1) facilitated the determination of high levels of fluoride in phosphate rock (up to 4.1%) with out the need for excessive on-line dilution.The optimized flow system was applied for the determination of fluoride in phosphate rocks samples and a reference material at a rate of nine samples per hour with a relative standard deviation (n = 5) of 2.95-4.0 %. Comparison of the proposed flow injection method with the standard method, which involves steam distillation from sulfuric acid solution and manual titration with thorium nitrate, showed no evidence of bias at the 95% confidence level.  相似文献   

18.
Fast-heating programmes for determining titanium and tin in soils, sediments and sludges using electrothermal atomic absorption spectrometry (ETAAS) with slurry sampling are developed. For titanium determination, suspensions are prepared by weighing 5-40 mg of sample and adding 25 ml of a solution containing 50% (v/v) concentrated hydrofluoric acid. For tin determination, suspensions are prepared by weighing up to 300 mg of sample and then adding 1 ml of a solution containing 25% (v/v) concentrated hydrofluoric acid. Palladium (30 μg) and ammonium dihydrogen phosphate (7% w/v) are used as matrix modifiers for titanium and tin, respectively. Prior mild heating in a microwave oven is recommended for titanium determination. Calibration is carried out using aqueous standards. The tin and titanium contents of a number of samples obtained by using the slurry approach agree with those obtained by means of a procedure based on the total dissolution of the samples using microwave oven digestion. The reliability of the procedures is also confirmed by analysing several certified reference materials.  相似文献   

19.
Polychlorotrifluoroethylene (PCTFE) in the form of beads was applied, as packing material for flow injection on-line column preconcentration and separation systems coupled with flame atomic absorption spectrometry (FAAS). Its performance characteristics were evaluated for trace copper determination in environmental samples. The on-line formed complex of metal with diethyldithiophosphate (DDPA) was sorbed on the PCTFE surface. Isobutyl methyl ketone (IBMK) at a flow rate of 2.8 mL min−1 was used to elute the analyte complex directly into the nebulizer-burner system of spectrophotometer. The proposed sorbent material reveal, excellent chemical and mechanical resistance, fast adsorption kinetics permitting the use of high sample flow rates up to 15 mL min−1 without loss of retention efficiency. For copper determination, with 90 s preconcentration time the sample frequency was 30 h−1, the enhancement factor was 250, which could be further improved by increasing the loading (preconcentration) time. The detection limit (3s) was cL = 0.07 μg L−1, and the precision (R.S.D.) was 1.8%, at the 2.0 μg L−1 Cu(II) level. For lead determination, the detection limit was cL = 2.7 μg L−1, and the precision (R.S.D.) 2.2%, at the 40.0 μg L−1 Pb(II) level. The accuracy of the developed method was evaluated by analyzing certified reference materials and by recovery measurements on spiked natural water samples.  相似文献   

20.
A flow injection (FI) method was developed using hydraulic high-pressure nebulization as a sample introduction system, coupled to inductively coupled plasma time-of-flight mass spectrometer (ICP-TOFMS) for rapid and simultaneous determination of 19 elements. The operating conditions of the system (analyte flow rate, heating and cooling temperatures of the desolvation module, carrier gas flow rate) for the simultaneous determination of 19 analytes were optimised. The optimum parameters of the sample introduction system were found to be 1.4 ml min−1 and 1.35 l min−1 for the analyte solution and nebulizer flow rates, respectively. A compromised condition for heating and cooling stage temperatures of 170 and −5 °C was chosen. The detection limits were compared to those obtained by using ICP-TOFMS with alternative sample introduction techniques e.g. conventional nebulization, flow injection chemical hydride generation (FI-CHG) and the obtained results were comparable or better than those resulting from alternative sample introduction. Applying the optimised conditions the simultaneous determination of Ag, As, Ba, Cd, Co, Cu, Ga, In, Li, Mn, Mo, Pb, Sb, Se, Sn, Sr, Tl, V and Zn was carried out. Absolute detection limits (3σ) in the range of 2-750 pg and precision between 0.5 and 9.6% from five replicate measurements of 10 ng ml−1 multielemental sample solutions were achieved by using a 200 μl sample loop. The developed method was applied for the analysis of certified reference materials of biological origin (TORT-2 “Lobster Hepatopancrease”, BCR-422 “Cod Muscle” and IAEA MA-B-3/TM “Fish Homogenate”), and the results showed good agreement with the certified values.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号