首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
The voltammetric behaviour of Imatinib (STI 571) and its main metabolite (N-demethylated piperazine derivative) were studied by square-wave techniques, resulting in to two methods for their determination in aqueous and urine samples at pH 2. The application of the square-wave (SW) without the adsorptive accumulation and voltammetric stripping (AdSV) exhibit a peak at a reduction potential of −0.70 V for an accumulation potential of −0.45 V. The sensitivity was higher for the stripping technique because a signal four times higher than that provided by the square-wave method without the previous accumulation was obtained. Due to the fact that Imatinib and its metabolite show the same voltammetric reduction process, some experiments were performed in order to compare the voltammetric response of Imatinib and its main metabolite in a similar ratio than that of the therapeutic concentration. The calibration curve for Imatinib in urine was linear in the range from 1.9 × 10−8 to 1.9 × 10−6 M in stripping mode with an accumulation time (tacc) of 10 s. The relative standard deviations obtained for concentration levels of Imatinib as low as 2.0 × 10−7 M for square-wave was 2.17% (n = 9) and for stripping square-wave was 2.65% (n = 9) in the same day. The limits of detection for square-wave and stripping square-wave were 5.55 × 10−9 and 5.19 × 10−9 M, respectively. Thus, the presented method are straightforward, rapid and sensitive and has been applied to the determination of Imatinib and its main metabolite altogether in urine samples from real patients.  相似文献   

2.
《Electroanalysis》2004,16(8):661-666
The behavior of Mifepristone (RU‐486) was studied by square‐wave technique, leading to two methods for its determination in aqueous samples and urine samples at pH 2. The application of the square‐wave (SW) without the adsorptive accumulation and stripping voltammetric (AdSV) show the maximum response at ?0.896 V using an accumulation potential of ?0.5 V. The effect of experimental parameters that affect this determination are discussed. For the stripping technique, Mifepristone proved to be more sensitive, yielding signals four times larger than those obtained by applying a square‐wave scan without the previous accumulation. The calibration plot to determine Mifepristone was linear in the range 2.4×10?8 and 5.4×10?7 M by stripping mode with an accumulation time tacc of 30 s. The relative standard deviation obtained for concentration levels of Mifepristone as low as 2.0×10?7 M with square‐wave was 1.17% (n=10) and with stripping square‐wave 2.02% (n=10) in the same day. The two proposed methods (SW and SWAdSV) were applied to the determination of Mifepristone in urine.  相似文献   

3.
This work reports the determination of trace Co(II) by adsorptive stripping voltammetry on disposable three-electrode cells with on-chip metal-film electrodes. The heart of the sensors was a bismuth-film electrode (BiFE) with Ag and Pt planar strips serving as the reference and counter electrodes, respectively. Metals were deposited on a silicon chip by sputtering while the areas of the electrodes were patterned via a metal mask. Co(II) was determined by square wave adsorptive stripping voltammetry (SWAdSV) after complexation with dimethylglyoxime (DMG). The experimental variables (the DMG concentration, the preconcentration potential, the accumulation time and the SW parameters), as well as potential interferences, were investigated. Using the selected conditions, the 3σ limit of detection was 0.09 μg l−1 of Co(II) (for 90 s of preconcentration) and the relative standard deviation for Co(II) was 3.8% at the 2 μg l−1 level (n = 8). The method was applied to the determination of Co(II) in a certified river water sample. These mercury-free electrochemical devices present increased scope for field analysis and μ-TAS applications.  相似文献   

4.
Farghaly OA 《Talanta》2004,63(2):497-501
A square wave adsorptive stripping voltammetric (SWAdSV) method for the indirect determination of trace amounts of magnesium with thiopentone sodium (TPS) as an electroactive ligand, at carbon paste mercury film electrode (CP-MFE) is proposed. It is observed that the increase of the square wave voltammetric cathodic peak current of TPS, under alkaline conditions, is linear with the increase of Mg concentration. Under optimum experimental conditions viz.; pH 10.75, 3×10−5 M TPS and 0.05 M phosphate buffer (Na2HPO4-NaH2PO4), a linear relation in the range 6×10−9 to 9×10−8 M Mg2+ (0.14-2.16 ppb), at 60 s deposition time, is obtained. The detection limit of Mg2+ is 0.14 ppb for 60 s deposition time with the relative standard deviation is 0.5% (n=5). The proposed method was successfully applied to the determination of magnesium in urine and tap water samples with satisfactory results. The data obtained are compared with the standard flame atomic absorption spectrophotometric method (FAAS).  相似文献   

5.
This works reports the use of square-wave adsorptive stripping voltammetry (SWAdSV) for the simultaneous determination of Ni(II) and Co(II) on a rotating-disc bismuth-film electrode (BFE). The metal ions in the non-deoxygenated sample were complexed with dimethylglyoxime (DMG) and the complexes were accumulated by adsorption on the surface of the BFE. The stripping step was carried out by using a square-wave potential-time voltammetric excitation signal. Electrochemical cleaning of the bismuth film was employed, enabling the same bismuth film to be used for a series of measurements. The experimental variables (choice of the working electrode substrate, the presence of oxygen, the DMG concentration, the buffer concentration, the preconcentration potential, the accumulation time, the rotation speed and the SW parameters) as well as potential interferences were investigated and the figures of merit of the methods were established. Using the selected conditions, the 3σ limits of detection were 70 ng l−1 for Co(II) and 100 ng l−1 for Ni(II) (for 300 s of preconcentration) and the relative standard deviations were 2.3% for Co(II) and 3.9% for Ni(II) at the 2 μg l−1 level (n = 8). Finally, the method was applied to the determination of nickel and cobalt in real samples with satisfactory results.  相似文献   

6.
Nalidixic acid (NA) and its main metabolite, 7-hydroximethylnalidixic acid (OHNA), are quinolones antibacterial used as agents used for the treatment of urinary tract infection. For both compounds an adsorption process on a hanging mercury electrode (HMDE). On this basis, a square wave adsorptive stripping voltammetry (SWadSV) method has been developed for the individual and simultaneous determination of NA and OHNA. The variables that affect to accumulation process, such as concentration of perchloric acid, accumulation potential and accumulation time have been optimised by using an experimental design (concretely a Box-Behnken design with three levels) together with the response surface methodology (RSM). Calibration curves were linear in the range (0-1.38) × 10−7 mol L−1 for NA and (0-3.23) × 10−8 mol L−1 for OHNA, in the optimized conditions, with detection limits of 9.48 × 10−9 mol L−1 and 8.06 × 10−10 mol L−1 for NA and OHNA, respectively. The method was applied to urine samples containing only one of the analytes with satisfactory recoveries. As the voltammetric signals of these compounds show a high overlapping, different chemometric methods, such as classical least squares (CLS), partial least squares (PLS), principal component regression (PCR) and artificial neural network (ANN) have been used for the resolution of the mixture. The analysis of these compounds in urine samples were carried out using the different chemometric tools and the best recoveries were obtained by using ANN. No pre-treatment of the sample was necessary.  相似文献   

7.
Gazy AA 《Talanta》2004,62(3):575-582
The adsorptive and electrochemical behavior of amlodipine besylate on a glassy carbon electrode were explored in Britton-Robinson buffer solution by using cyclic and square-wave voltammetry. Cyclic voltammetric studies indicated the oxidation of amlodipine besylate at the electrode surface through a single two-electron irreversible step and fundamentally controlled by adsorption. The solution conditions and instrumental parameters were optimized for the determination of the authentic drug by adsorptive square-wave stripping voltammetry. Amlodipine besylate gave a sensitive adsorptive oxidation peak at 0.510 V (versus Ag/AgCl). The oxidation peak was used to determine amlodipine besylate in range 4.0×10−8 to 2.0×10−6 with a detection limit of 1.4×10−8 M. The procedure was successfully applied for the assay of amlodipine besylate in tablets (Norvasc)®. The percentage recoveries were in agreement with those obtained by the reference method. Applicability to assay the drug in urine and serum samples was illustrated. The mean percentage recoveries were 96.31±1.18 and 96.98±1.17, respectively. The proposd method used for monotoring clinically relevant concntrations of drug in human urine and serum.  相似文献   

8.
In situ mercury film electrode produced in the presence of thiocyanate has been shown extremely useful for highly sensitive adsorptive stripping voltammetric measurements of atrazine down to sub-μg L−1 level. Operational parameters have been optimized and the stripping voltammetric performance has been investigated using square wave scans. The adsorptive stripping response is linear over the range of 0.5-60 μg L−1 atrazine, with a detection limit of 0.024 μg L−1. The method has been applied to the determination of atrazine in soil and water samples.  相似文献   

9.
The paper presents the first report on fabrication and application of a user friendly and mercury free electrochemical sensor, with the renewable bismuth bulk annular band working electrode (RBiABE), in stripping voltammetry (SV). The sensor body is partly filled with the internal electrolyte solution, in which the RBiABE is cleaned and activated before each measurement. Time of the RBiABE contact with the sample solution is precisely controlled. The usefulness of this sensor was tested by Ni(II) and Co(II) traces determination by means of differential pulse adsorptive stripping voltammetry (DP AdSV), after complexation with dimethylglyoxime (DMG) in ammonia buffer (pH 8.2). The experimental variables (composition of the supporting electrolyte, pre-concentration potential and time, potential of the RBiABE activation, and DP parameters), as well as possible interferences, were investigated. The linear calibration graphs for Ni(II) and Co(II), determined individually and together, in the range from 1 × 10−8 to 70 × 10−8 mol L−1 and from 1 × 10−9 to 70 × 10−9 mol L−1 respectively, were obtained. The calculated limit of detection (LOD), for 30 s of the accumulation time, was 3 × 10−9 mol L−1 for Ni(II) in case of a single element’s analysis, whereas the LOD was 5 × 10−9 mol L−1 for Ni(II) and 3 × 10−10 mol L−1 for Co(II), when both metal ions were measured together. The repeatability of the Ni(II) and Co(II) adsorptive stripping voltammetric signals obtained at the RBiABE were equal to 5.4% and 2.5%, respectively (n = 5). Finally, the proposed method was validated by determining Ni(II) and Co(II) in the certified reference waters (SPS-SW1 and SPS-SW2) with satisfactory results.  相似文献   

10.
The electrochemistry of metronidazole, 1-(hydroxyethyl)-2-methyl-5-nitroimidazole, was investigated at a carbon fiber microdisk electrode in pH 9 Britton Robinson buffer. Under these conditions, the reduction of metronidazole is controlled by both mass transport to the microdisk and adsorption with an equilibrium constant of 4 × 103 mol−1 dm3 and a saturation coverage of 0.88 × 10−8 mol cm−2. The adsorption and accumulation of metronidazole on the surface of the carbon fiber allows its determination at low concentrations by square wave adsorptive stripping voltammetry. A detection limit for metronidazole of 5 × 10−7 mol dm−3 and a R.S.D. of 3.7% at 1 × 10−6 mol dm−3 (n = 4) were obtained with a two electrode system with no stirring during the accumulation step. Based on this method, a simple procedure for the determination of metronidazole in urine is described which requires no pre-treatment of the sample before analysis.  相似文献   

11.
Uranium (VI) (U(VI)) forms a complex with dipicolinic acid (2, 6-pyridinedicarboxylic acid).This complex can be used for a highly sensitive and selective determination of uranium by adsorptive cathodic stripping voltammetry (ACSV) using a hanging mercury drop electrode (HMDE) as working electrode. Influence of effective parameters such as pH, concentration of ligand, accumulation potential and accumulation time on the sensitivity and selectivity were studied. The detection limit (3σ of the blank value) obtained under the optimal experimental conditions is 0.27 × 10−9 M after 150 s of the accumulation time. The peak current is proportional to the concentration of U(VI) in the range of 1 × 10−9 to 1.2 × 10−7 M. The relative standard deviation of 2.5% at the 3.5 × 10−8 M level was obtained. The interference of some metal ions and anions were studied. The application of this method was tested in the determination of uranium in synthetic and natural water samples.  相似文献   

12.
The cyclic voltammogram of the anti-coagulant drug warfarin sodium at the hanging mercury drop electrode exhibited a well-defined single two-electron irreversible peak over the pH range 4-7, which may be attributed to the reduction of the CO double bond of the drug molecule. Based on the interfacial adsorptive character of the drug onto the mercury electrode surface, a square-wave cathodic stripping procedure was optimized for its trace determination. The calibration plot was linear over the concentration range of 5×10−9 to 4×10−7 M warfarin sodium in Britton-Robinson (B-R) buffer of pH 5, with limits of detection and quantitation of 6.5×10−10 and 2.1×10−9 M warfarin sodium, respectively. The proposed procedure was successfully applied for assay of warfarin sodium in its pharmaceutical formulation “hemofarin tablets”, human serum and urine without the necessity for sample pretreatment or time-consuming extraction or evaporation steps, prior to assay of the drug. Limits of detection of 1.1×10−9 and 1.3×10−8 M warfarin sodium were achieved, while limits of quanitation of 3.7×10−9 and 4.3×10−8 M warfarin sodium were estimated in human serum and urine, respectively. The pharmacokinetic profiles of the drug were studied and the estimated pharmacokinetic parameters were favorably compared with those reported in literature.  相似文献   

13.
A sensitive method is described for the determination of trace bismuth based on the bismuth-bromopyrogallol red (BPR) adsorption at a carbon paste electrode (CPE). The overall analysis involved a three-step procedure: accumulation, reduction, and anodic stripping. Optimal conditions were found to be an electrode containing 25% paraffin oil and 75% high purity graphite powder, a 0.30 mol l−1 HCl solution containing 2.0×10−5 mol l−1 BPR as supporting medium; accumulation potential and time, −0.10 V, 3 min; reduction potential and time, −0.35 V, 60 s; scan rate 100 mV s−1; scan range from −0.35 to 0.15 V. It was found that the Bi(III)-BPR complex could be accumulated on the electrode surface during the accumulation period. Then the Bi(III) in the Bi(III)-BPR complex on the CPE surface was reduced to Bi(0) during reduction interval and finally reoxidized during the anodic stripping step for voltammetric quantification. Factors affecting the accumulation, reduction, and stripping steps were investigated. Interferences by other ions were studied as well. The detection limit was found to be 5×10−10 mol l−1 with a 3 min accumulation time. The linear range was from 1.0×10−9 to 5.0×10−7 mol l−1. Application of the procedure to the determination of bismuth in water and human hair samples gave good results.  相似文献   

14.
A sensitive method of Co(II) determination by adsorptive stripping voltammetry is presented. The method exploits the enhancement of cobalt peak current observed in the system Co(II)-nioxime-cetyltrimethylammonium bromide-piperazine-N,N′-bis(2-ethanesulfonic acid). The calibration plot for an accumulation time of 60 s is linear from 5 × 10−11 to 3 × 10−9 mol L−1. The relative standard deviation is 3.8% for Co(II) determination at concentration 1 × 10−9 mol L−1. The detection limit is 1.7 × 10−11 mol L−1. The validation of the method is performed by the analyses of certified reference materials and comparing the result of Co(II) determination in river water sample by the proposed method with those obtained by ET AAS. The main advantage of this new system is the micro-trace Co(II) determination by adsorptive stripping voltammetry, as compared to those described before, a low concentration of the supporting electrolyte used, and so commercially available reagents without additional purification can be used.  相似文献   

15.
An in situ plated lead film electrode has been applied for adsorptive stripping voltammetric determination of trace concentrations of molybdenum in the presence of Alizarin S. The procedure is based on the preconcentration of the molybdenum-Alizarin S complex at an in situ plated lead film electrode held at −0.6 V (versus Ag/AgCl), followed by a negatively sweeping square wave voltammetric scan. The peak current is proportional to the concentration of molybdenum over the range 2 × 10−9 to 5 × 10−8 mol L−1, with a 3σ detection limit of 9 × 10−10 mol L−1 with an accumulation time of 60 s. The measurements were carried out from underaerated solutions. The proposed procedure was validated in the course of Mo(VI) determination in water certified reference materials.  相似文献   

16.
This work reports on the performance of carbon nanotube modified screen-printed electrodes (SPE-MWCNT) for the selective determination of dopamine (DA) in the presence of ascorbic acid (AA) by adsorptive stripping voltammetry (AdSV). Several operating conditions and parameters were examined including the electrochemical pre-treatment and the previous AA interaction and DA accumulation in the presence AA at physiological conditions. Under the chosen conditions, DA peak current of differential pulse voltammograms increases linearly with DA concentration in the range of 5.0 × 10−8 to 1.0 × 10−6 mol L−1 with a limit of detection of 1.5 × 10−8 mol L−1 in connection with 600 s accumulation time. The sensitivity obtained for DA was independent from the presence or absence of AA; therefore, the proposed method can be readily applied to detect DA in real samples. The proposed methodology was successfully used for the quantification of DA in urine samples.  相似文献   

17.
In this work, a simple and sensitive electroanalytical method was developed for the determination of enrofloxacin (ENRO) by adsorptive cathodic stripping voltammetry (ADSV) using Cu(II) as a suitable probe. The complex of copper(II) with ENRO was accumulated at the surface of a hanging mercury drop electrode at −0.10 V for 40 s. Then, the preconcentrated complex was reduced and the peak current was measured using square wave voltammetry (SWV). The optimization of experimental variables was conducted by experimental design and support vector machine (SVM) modeling. The model was used to find optimized values for the factors such as pH, Cu(II) concentration and accumulation potential. Under the optimized conditions, the peak current at −0.30 V is proportional to the concentration of ENRO over the range of 10.0-80.0 nmol L−1 with a detection limit of 0.33 nmol L−1. The influence of potential interfering substances on the determination of ENRO was examined. The method was successfully applied to determination of ENRO in plasma and pharmaceutical samples.  相似文献   

18.
Mahajan RK  Walia TP  Sumanjit  Lobana TS 《Talanta》2005,67(4):755-759
The adsorptive cathodic stripping voltammetry technique (AdCSV) is used to determine copper(II) using salicylaldehyde thiosemicarbazone (N, S- donor) as a complexing agent on hanging mercury drop electrode at pH 9.3. Variable factors affecting the response, i.e. the concentration of ligand, pH, adsorption potential and adsorption time are assessed and optimized. The adsorbed complex of copper(II) and salicylaldehyde thiosemicarbazone gives a well defined cathodic stripping peak current at −0.35 V, which has been used for the determination of copper in the concentration range of 7.85 × 10−9 to 8.00 × 10−6 M with accumulation time of 360 s at −0.1 V versus Ag/AgCl. This technique has been applied for the determination of copper in various digested samples of whole blood at trace levels.  相似文献   

19.
A modified carbon paste electrode based on multi-walled carbon nanotubes (MWCNTs) and 3-(4-methoxybenzylideneamino)-2-thioxothiazolodin-4-one as a new synthesized Schiff base was constructed for the simultaneous determination of trace amounts of Hg(II) and Pb(II) by square wave anodic stripping voltammetry. The modified electrode showed an excellent selectivity and stability for Hg(II) and Pb(II) determinations and for accelerated electron transfer between the electrode and the analytes. The electrochemical properties and applications of the modified electrode were studied. Operational parameters such as pH, deposition potential and deposition time were optimized for the purpose of determination of traces of metal ions at pH 3.0. Under optimal conditions the limits of detection, based on three times the background noise, were 9.0 × 10−4 and 6.0 × 10−4 μmol L−1 for Hg(II) and Pb(II) with a 90 s preconcentration, respectively. In addition, the modified electrode displayed a good reproducibility and selectivity, making it suitable for the simultaneous determination of Hg(II) and Pb(II) in real samples such as sea water, waste water, tobacco, marine and human teeth samples.  相似文献   

20.
Yuan S  Chen W  Hu S 《Talanta》2004,64(4):922-928
An anthraquinone (AQ) improved Na-montmorillonite nanoparticles (nano-SWy-2) chemically modified electrode (CME) has been developed for the simultaneous determination of trace levels of cadmium (II) and lead (II) by differential pulse anodic stripping voltammetry (DPASV). This method is based on a non-electrolytic preconcentration via ion exchange model, followed by an accumulation period via the complex formation in the reduction stage at −1.2 V, and then by an anodic stripping process. The mechanism of this design was proposed and the analytical performance was evaluated with several variables. Under the optimized working conditions, the detection limit was 3 and 1 nM for Cd2+ and Pb2+, respectively. The calibration graphs were linear in the concentration ranges of 8×10−9 to 1×10−6 mol L−1 (Cd2+) and of 2×10−9 to 1×10−6 mol L−1 (Pb2+). Many inorganic species did not interfere with the assay significantly; the high sensitivity, selectivity, and stability of this nano-SWy-2-AQ CME were demonstrated. The applications for the detection of trace levels of Cd2+ and Pb2+ in milk powder and lake water samples indicate that it is an economical and potent method.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号