首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A HPLC-fluorescence method for identification of drying oils from binding media or protective film used in pictorial works of art prior to conservation or restoration is proposed. Fluorescence derivatization of fatty acids released by hydrolysis of structural drying oils is studied. The derivatization reagent was 4-(bromomethyl)-7-methoxycoumarin with 18-crown-6 as catalyst. Mobile phase was programmed from methanol-water (90:10 v/v) to methanol-water (100:0 v/v) in 25 min. The excitation and emission wavelengths were 325 and 395 nm, respectively. Under these chromatographic conditions, coumarin derivatives of myristic, palmitic, oleic and stearic acids were satisfactorily resolved. The method shows good sensitivity, with a detection limit of 6.0 x 10(-8) mmol, and good linearity between 1.0 x 10(-7) and 1.8 x 10(-4) mmol of each analyte. Peak area ratios among fatty acids derivatives, especially the stearic acid/palmitic acid peak area ratio, are useful to identify the drying oils. The proposed method has been successfully applied to artistic samples from items of the cultural heritage of Valencia (Spain).  相似文献   

2.
A micellar electrokinetic capillary chromatography (MEKC) method with laser-induced fluorescence detection (LIF) was developed for analyzing three phosphoamino acids including phosphotyrosine (P-Tyr), phosphoserine (P-Ser), and phosphothreonine (P-Thr). 3-(2-Furoyl)quinoline-2-carboxaldehyde (FQ), a fluorogenic dye, was employed for derivatization of these phosphoamino acids. Results indicated that the complete baseline resolution of each phosphoamino acid was obtained within 10 min, using 20 mmol l−1 sodium borate buffer (pH 9.35) containing 20 mmol l−1sodium deoxycholate (SDC) and 10 mmol l−1 Brij35. Other common amino acids, especially Glu and Asp, did not disturb the assay of these phosphoamino acids. There was a linear relationship between the peak area for analyte and its concentration, with correlation coefficients in the range of 0.9966-0.9996. The concentration detection limits (signal-to-noise = 3) for P-Tyr, P-Ser, and P-Thr were 10, 40, and 75 nmol l−1, respectively. The developed method was successfully applied for determining phosphoamino acids in the hydrolysis sample of a phosphorylated protein kinase.  相似文献   

3.
Partial least squares modeling and gas-chromatographic fatty-acid fingerprints are reported as a method for the simultaneous determination of cottonseed, olive, soybean and sunflower edible oil mixtures. In this work, two sets of three- and four-component combinations of oils were prepared, hydrolyzed and the obtained free fatty acids analyzed by gas chromatography (GC) without any further derivatization. The normalized percentages of the myristic (14:0), palmitic (16:0), palmitoleic (16:1), stearic (18:0), oleic (18:1), linoleic (18:2) and linolenic (18:3) acids were chromatographically measured in samples and used for constructing calibration matrix. The cross-validation method was used to select the number of factors and the proposed methods were validated by using two sets of synthetic oil mixture samples. The relative standard error for each oil in mixture samples was less than 10%. This approach allows determining possible adulteration in each of the four edible oils.  相似文献   

4.
The correct identification of drying oils plays an essential role in providing an understanding of the conservation and deterioration of artistic materials in works of art. To this end, this work proposes the use of peak area ratios from fatty acids after ensuring that the linear responses of the detector are tested. A GC-MS method, previously reported in the literature, was revisited to its developed and validated in order to identify and quantify of eight fatty acids that are widely used as markers for drying oils in paintings, namely myristic acid (C(14:0)), palmitic acid (C(16:0)), stearic acid (C(18:0)), oleic acid (C(18:1)), linoleic acid (C(18:2)), suberic acid (2C(8)), azelaic acid, (2C(9)) and sebacic acid (2C(10)). The quaternary ammonium reagent m-(trifluoromethyl)phenyltrimethylammonium hydroxide (TMTFAH) was used for derivatization prior to GC-MS analysis of the oils. MS spectra were obtained for each methyl ester derivative of the fatty acids and the characteristic fragments were identified. The method was validated in terms of calibration functions, detection and quantification limits and reproducibility using the signal recorded in SIR mode, since two of the methyl derivatives were not totally separated in the chromatographic run. The proposed method was successfully applied to identify and characterise the most widely used drying oils (linseed oil, poppy seed oil and walnut oil) in the painting La Encarnación. This 17th century easel painting is located in the main chapel of the cathedral in Granada (Spain) and was painted by the well-known artist of the Spanish Golden Age, Alonso Cano (1601-1667).  相似文献   

5.
Mass spectrometry methodology to characterize drying oil used as binding media and varnishes in pictorial artworks, prior to conservation or restoration treatment, is proposed. The analytical treatment requires prior basic hydrolysis of the samples to release the fatty acids: caprylic, pelargonic, capric, sebacic, azelaic, suberic, eicosanoic, lauric, mirystic, palmitic, linolenic, linoleic, oleic and stearic, followed by separation from the matrix by a hexane/water extraction. After removing the solvent, the remaining solid is dissolved in potassium hydroxide, propanol and methanol. The mixture is directly infused into a mass spectrometer without any previous derivatization or separation steps. The detector is operated in electrospray negative ion mode and the [M-H](-) ions of the fatty acids enable identification of the acids. Obtained data for fatty acid ion abundances are analyzed by linear discriminant analysis. The drying oils studied (linseed, poppy seed and walnut) were satisfactorily distinguished. The analytical method shows adequate sensitivity, reproducibility, speed and ease. The proposed methodology has been successfully applied to samples from artistic samples belonging to the Cultural Heritage of Valencia (Spain).  相似文献   

6.
This work presents an high-performance liquid chromatography method for the determination of amino acids after precolumn derivatization with 4-chloro-3,5-dinitrobenzotrifluoride (CNBF) which can readily react with both primary and secondary amines. The precolumn derivatization conditions, including the CNBF concentration, reaction pH, temperature and reaction time were investigated for method optimization. In pH 9.0 borate buffer, the reaction of amino acids with CNBF was carried out at 60 °C for 30 min, the optimized concentration of CNBF was 70 mmol L−1 and the molar ratio of amino acids to CNBF was 1:5.25. The chromatographic separation of 19 amino acids derivatives was performed on a Kromasil ODS C18 column (250 mm × 4.6 mm, 5 μm) with good reproducibility, and ultraviolet detection was applied at 260 nm. The mobile phase was a mixture of phase A (acetonitrile) and phase B (acetate buffer, acetonitrile, triethylamine; 82.8:17:0.2, pH 4.9), and the flow rate was 0.4 mL min−1. The separation of all the labeled amino acids was achieved within 45 min at room temperature by gradient elution mode. The method linearity, calculated for each amino acid, had a correlation coefficient higher than 0.9979, in concentrations ranging from 9.60 to 3330.00 μmol L−1. The detection limits of amino acids were 2.40-6.50 μmol L−1, at a signal-to-noise ratio of 3. The proposed method was applied for the determination of amino acids in beer with recoveries of 97.0-103.9% and relative standard deviations of 2.62-4.22%, respectively. This method showed good accuracy and repeatability that can be used for the quantification of amino acids in real samples.  相似文献   

7.
The correct identification of drying oils plays an essential role in providing an understanding of the conservation and deterioration of artistic materials in works of art. To this end, this work proposes the use of peak area ratios from fatty acids after ensuring that the linear responses of the detector are tested. A GC-MS method, previously reported in the literature, was revisited to its developed and validated in order to identify and quantify of eight fatty acids that are widely used as markers for drying oils in paintings, namely myristic acid (C14:0), palmitic acid (C16:0), stearic acid (C18:0), oleic acid (C18:1), linoleic acid (C18:2), suberic acid (2C8), azelaic acid, (2C9) and sebacic acid (2C10). The quaternary ammonium reagent m-(trifluoromethyl)phenyltrimethylammonium hydroxide (TMTFAH) was used for derivatization prior to GC-MS analysis of the oils. MS spectra were obtained for each methyl ester derivative of the fatty acids and the characteristic fragments were identified. The method was validated in terms of calibration functions, detection and quantification limits and reproducibility using the signal recorded in SIR mode, since two of the methyl derivatives were not totally separated in the chromatographic run. The proposed method was successfully applied to identify and characterise the most widely used drying oils (linseed oil, poppy seed oil and walnut oil) in the painting La Encarnación. This 17th century easel painting is located in the main chapel of the cathedral in Granada (Spain) and was painted by the well-known artist of the Spanish Golden Age, Alonso Cano (1601-1667).  相似文献   

8.
In this article, a laboratory-made sol-gel derived fiber with butyl methacrylate/hydroxy-terminated silicone oil (BMA/OH-TSO) coating was first used for headspace solid-phase microextraction (HS-SPME) of medium and long chain fatty acids after derivatization and applied to the analysis of fatty acids in lung tissues by coupling to gas chromatography-mass spectrometry (GC-MS). The experimental parameters for derivatization, HS-SPME and desorption were optimized. Fatty acids in cancerous lung tissues from five patients with lung cancer were determined under the optimized conditions. Normal lung tissues from the same five patients were used as controls. This fiber showed higher extraction efficiency for fatty acids after derivatization when compared with commercial polydimethylsiloxane (PDMS) and polydimethylsiloxane-divinylbenzene (PDMS/DVB) fibers due to the three-dimensional network in the coating. The method presented in this paper showed satisfactory precision, accuracy, linearity and limits of detection (LODs). The relative standard deviation values were below 13.3% (n = 5) and the recoveries obtained ranged from 76.35% to 107.0%. The results obtained using the SPME method were also compared with those got by using liquid-liquid extraction (LLE) technique. It was found that the sensitivity could be enhanced by the SPME method. The analysis of the cancerous lung tissues and normal controls from five patients with lung cancer indicated that the main components of lung tissue were palmitic acid (C16:0), stearic acid (C18:0) and lignoceric acid (C24:0). A comparison between the levels of the fatty acids in cancerous lung tissues and normal controls from the same a patient with lung cancer shows that most of the saturated fatty acids showed higher levels in cancerous lung tissues, while unsaturated fatty acids showed higher levels in normal controls on the whole.  相似文献   

9.
A microwave assisted wet digestion method for organoarsenic compounds and subsequent determination of total arsenic in aqueous, biological and sediment samples by means of flow injection hydride generation electrothermal atomic absorption spectrometry (FI-HG-ETAAS) is described. Sodium persulfate, sodium fluoride and nitric acid serve as digestion reagents, which allow a quantitative transformation of organoarsenic compounds to hydride forming species in a commercial microwave sample preparation system. The maximum operating pressures of the applied tetrafluorometoxil (TFM) liners are 75 bar (high pressure vessels) and 30 bar (medium pressure vessels), corresponding to maximum solution temperatures of 300 and 260 °C. For the investigated samples, digestion temperatures of 210-230 °C (medium pressure vessels) and 240-280 °C (high pressure vessels) were obtained.In medium pressure vessels, arsenic recovery from aqueous testing solutions of dimethylarsinic acid (DMA), phenylarsonic acid (PAA) and tetraphenylarsonium chloride (TPA) at initial concentrations of 100 and 10 μg l−1 is complete, even in the presence of an excess of organic carbon (potassium hydrogen phthalate, 2000 mg l−1) or fatty acids (linolenic acid 70%; linoleic acid ≈20-25%; Oleic acid ≈3%, 900-4500 mg l−1).Arsenic recovery from aqueous arsenobetaine (ASB) solutions with the same initial concentrations is also complete if high pressure vessels and a higher concentration of fluoride ions are used, whereas the addition of organic carbon (potassium hydrogen phthalate, 2000 mg l−1, fatty acids, 900-4500 mg l−1) leads to a decrease in arsenic recovery of about 2-5%. In all cases, residual carbon contents are close to the limit of detection for the applied analytical method (15 mg l−1).Results of arsenic analysis in reference standard materials revealed a significant dependence on the material’s nature (sediment samples, plant materials and seafood samples). Sediment samples and plant materials show recoveries for arsenic around 100% after a single-step digestion in medium pressure TFM liners. Seafood (fish/lobster/mussel samples) usually require either the use of high pressure vessels or a second digestion step, if medium pressure vessels are used.  相似文献   

10.
A weak chemiluminescence (CL) emission was observed in commercial Greek extra virgin olive oils (Knossos, Spitiko, Ananias, Altis, Minerva, Xenia) and in refined seed oils such as sunflower oils (Marata, Sanola, Sun, Mana, Sol, Minerva) as well as in corn oils (Flora, Minerva, Marata Sun and Sol) with potassium superoxide in the aprotic solvent dimethoxyethylene.On measuring the CL of mixtures of extra virgin olive oils with the cheaper refined seed oils, calibrations were produced which can be used for the determination of the adulteration of olive oils with seed oils down to 3%. Furthermore, depending on the kind of oils, “low” authenticity-CL-factors for olive oils (0.8-2.15 μmol l−1 gallic acid) and “high” for seed oils (4.5-11.2 μmol l−1 gallic acid) were calculated.  相似文献   

11.
Chen F  Wang S  Guo W  Hu M 《Talanta》2005,66(3):755-761
High performance capillary electrophoresis (HPCE) was developed for quantitative determination of 18 phenylthiohydantoin (PTH)-amino acids. The influence of electrolyte concentration, pH, organic modifier and applied voltage on HPCE performance was investigated. The HPCE separation of a PTH-amino acids mixture was much improved by adding organic modifier and Tris-boric acid buffer to the run buffer. After optimization of the method, 17 PTH-amino acids in a solution containing 18 PTH-amino acids could be separated using 400 mmol l−1 Tris-boric acid, 1.0 mmol l−1 diethylamine at pH 9.5 adjusted with 0.1 mol l−1 NaOH as a run buffer, voltage of 25 kV was applied, temperature was maintained at 25 °C, detection wavelength was 254 nm. The precision (n = 7) of this method is less than 3.2% (peak area) and 1.1% (migration time) of relative standard deviation (R.S.D.). Linearity was established over the concentration range 50-1000 μM of each derivative, with correlation coefficients (r) ranging between 0.9904 and 0.9993. The detection limits (S/N = 3) range from 2 to 48 μmol l−1. The method was applied to determine amino acids in Sargassum fusiforme, a marine algae collected from Tongtou County of Zhejiang Province in China with satisfactory results.  相似文献   

12.
The present study was designed to determine the fatty acid composition and phytosterol contents of Turkish native olive cultivars, namely Kilis Yağlık and Nizip Yağlık cv. In this context, olive fruits from 34 locations were sampled and then screened for their components in comparison. Fifteen different fatty acids were found in both olive oils. In the order of abundance, the most important ones were oleic acid (18:1) > palmitic acid (16:0) > linoleic acid (18:2) > stearic acid (18:0). Significant differences were observed in the contents of oleic acid (18:1), palmitic acid (16:0), linoleic acid (18:2) but not for stearic acid content in comparison both oils (p < 0.01). There were significant differences in terms of unsaturated fatty acids, saturated fatty acids and polyunsaturated fatty acids (p < 0.01). The seven phytosterols – cholesterol, campesterol, stigmasterol, β ‐sitosterol, Δ‐5‐avenasterol, Δ‐7‐stigmastenol and Δ‐7‐avenasterol – were studied in both oil sources. The predominant sterols were β ‐sitosterol, Δ5‐avenasterol and campesterol in the samples analysed. However, no significant differences were found in the levels of the phytosterols between the two olive cultivars.  相似文献   

13.
A highly sensitive method was developed for the identification and quantification of fatty alcohols in biological tissues. In the presence of pyridine-d0 and triflic anhydride (Tf2O), fatty alcohols were converted into permanently charged N-alkylpyridinium ions. Stable isotope-labeled derivatives were generated by pyridine-d5 and added as internal standard (IS). The mixture was analyzed by liquid chromatography coupled to positive electrospray ionization tandem mass spectrometry (LC–ESI-MS/MS). This method was optimized and validated in terms of reaction time, derivatization efficiency, stability, desalting, and ion suppression effect. Besides, fatty alcohols exhibited good linear relationship (r2 > 0.993) over the concentration range of 10 ng mL−1–1 μg mL−1. The limits of detection (LODs) were lowered from previously reported 0.1 ng mL−1 to 0.25 pg mL−1. Precision (RSD% < 15.6%), accuracy (93.0–107.2%), matrix effect, and recovery (in thyroid tissues) were validated as well. Finally, this method was applied for the analysis of ten even carbon-numbered fatty alcohols (C8–C24) in human thyroid carcinoma and para-carcinoma tissues, revealing a significant decrease of fatty alcohols (free and esterified) in thyroid carcinoma tissues (< 0.05).  相似文献   

14.
A procedure for the extraction of free amino acids was applied to isolate S-methylmethionine (SMM) from late harvest Petit Manseng grapes. Grapes were destemmed and crushed, and the obtained clarified must was percolated through cation-exchange resins (Dowex 50 WX4-100). The retained compounds were eluted with ammonia solution and the extract was finally concentrated. Taking into account the potential DMS (PDMS using heat-alkaline treatment assay) of the initial grape juice used (51.5 nmol mL−1) and the concentration factor of the extract (17.9-fold), the PDMS of the final extract (678 nmol mL−1) gave an overall recovery of 73.5% for juice SMM. This compound was identified and quantified (484.5 nmol mL−1 relatively to [2H3]-SMM used as internal standard) by its selective detection in this extract without derivatization by MALDI-TOF-MS using instrumentation and procedures previously reported to analyze SMM in complex natural extracts. SMM and 22 other amino acids in the initial must and in the final SMM extract were also determined using a Biochrom 30 amino acid analyser with post-column ninhydrin derivatization. SMM peak identification and quantification (401.2 nmol mL−1 relatively to norleucine used as internal standard) were carried out by comparison with commercial SMM.  相似文献   

15.
A new method is proposed for the chemiluminescent determination of the pesticide 3-indolyl acetic acid by means of an flow injection analysis system. The chemiluminescence emission is obtained by oxidation of the analyte with Ce (IV) in nitric acid and presence of β-cyclodextrine.The continuous-flow method allows the determination of 159 samples h−1 of 3-indolyl acetic acid in an interval of concentrations over the range 0.5-15.0 mg l−1. The limit of detection was 0.1 μg l−1 and the R.S.D. (n, 17) at 2.0 mg l−1 of the pesticide level was 2.7%. The method was applied to water samples.  相似文献   

16.
A sensitive method is described for the determination of trace bismuth based on the bismuth-bromopyrogallol red (BPR) adsorption at a carbon paste electrode (CPE). The overall analysis involved a three-step procedure: accumulation, reduction, and anodic stripping. Optimal conditions were found to be an electrode containing 25% paraffin oil and 75% high purity graphite powder, a 0.30 mol l−1 HCl solution containing 2.0×10−5 mol l−1 BPR as supporting medium; accumulation potential and time, −0.10 V, 3 min; reduction potential and time, −0.35 V, 60 s; scan rate 100 mV s−1; scan range from −0.35 to 0.15 V. It was found that the Bi(III)-BPR complex could be accumulated on the electrode surface during the accumulation period. Then the Bi(III) in the Bi(III)-BPR complex on the CPE surface was reduced to Bi(0) during reduction interval and finally reoxidized during the anodic stripping step for voltammetric quantification. Factors affecting the accumulation, reduction, and stripping steps were investigated. Interferences by other ions were studied as well. The detection limit was found to be 5×10−10 mol l−1 with a 3 min accumulation time. The linear range was from 1.0×10−9 to 5.0×10−7 mol l−1. Application of the procedure to the determination of bismuth in water and human hair samples gave good results.  相似文献   

17.
A modified automated on-line hyphenated system for simultaneous inorganic ionic mercury (Hg2+) and monomethylmercury (MeHg+) analysis by hydride generation (HG) or ethylation (Eth), cryofocussing, gas chromatography (GC) separation and atomic fluorescence spectrometry (AFS) detection has been improved. Both derivatization methods are investigated with respect to the chromatographic and analytical performances. They can be both affected by interferences when the AFS detection system is used. Water vapor removal using a soda lime moisture trap improves significantly the chromatographic performances, the reproducibility and the detection limits for Hg2+ and MeHg+ analyzed with both methods. For ethylation (Eth) derivatization, a scattering interference generated from low-quality ethylation reagent has also been eliminated. For HG, improved detection limits are 0.13 ng l−1 and 0.01 ng l−1 for Hg2+ and MeHg+, respectively (0.1 l water sample), and reproducibility are 5% for Hg2+ (20 ng l−1) and MeHg+ (5 ng l−1). Improved detection limits for Eth are 0.22 ng g−1 for Hg2+ and 0.02 ng g−1 for MeHg+ (1 g dry sediment sample) and the reproducibility are 5-6% for Hg2+ and MeHg+ (1-2 ng g−1).  相似文献   

18.
High-performance liquid chromatography (HPLC) and fluorescence derivatization were applied for a nanogram-level N-nitrosodimethylamine (NDMA) analysis of water samples. For the analysis of N-nitrosodimethylamine, samples were first denitrosated by a mixed solution of hydrobromic acid and acetic acid to produce dimethylamine, which was derivatized with dansyl chloride for HPLC fluorescence detection. Fluorescence detection was optimized with excitation and emission wavelengths of 340 and 530 nm, respectively. pH adjustment after denitrosation was necessary to maximize fluorescence intensity with pHs in the range of 9-12. A dansyl chloride concentration of 500 mg l−1 was found to be optimal for measuring a fluorescence signal. An instrumental detection limit of 0.1 ng of NDMA was possible with fluorescence derivatization. The NDMA in water samples was extracted by continuous solid-phase extraction using Ambersorb 572. Although the determination of NDMA was variable at lower concentrations (less than 200 ng l−1), it was observed that the NDMA detection limit with this method could be lowered to a concentration of 10 ng l−1. Another benefit of this method can be found in its selectivity for NDMA. Unlike gas chromatographic (GC) methods, this method generates a distinct peak for NDMA without interference even in the complex matrix of wastewater effluents. The HPLC with fluorescence derivatization method may be applicable for determining NDMA in water and wastewater samples for various research purposes and for screening environmental samples.  相似文献   

19.
Erdem A  Eroğlu AE 《Talanta》2005,68(1):86-92
A selective matrix removal/separation/enrichment method, utilizing a microcolumn of a chelating resin with SH functional groups (Duolite GT-73), was proposed for the determination of Sb(III) in waters by segmented flow injection-hydride generation atomic absorption spectrometry (SFI-HGAAS). The resin was selective to Sb(III) at almost all pH and acidity values employed, whereas Sb(V) was not retained at all and could be determined after a pre-reduction step with l-cysteine. Spike recoveries were tested at various concentration levels in different water types and were found to vary between 85 and 118%. Accuracy of the proposed methodology was checked by analyzing a standard reference material and a good correlation was found between the determined (13.3 ± 1.1 μg l−1) and the certified value (13.79 ± 0.42 μg l−1). The method was applied to several bottled drinking water samples for antimony determination with and without preconcentration and none of the samples were found to contain antimony above the permissible level (5 μg l−1). The characteristic concentration (the concentration of the analyte corresponding to an absorbance of 0.0044) was 0.55 μg l−1 and the 3 s limit of detection (LOD) based on five times preconcentration was 0.06 μg l−1. The applicability of the microcolumn separation/preconcentration/matrix removal method for flow injection systems was also demonstrated.  相似文献   

20.
The sequential injection (SIA) technique was applied for the on-line preparation of an “oil in water” microemulsion and for the determination of aluminum in new and used lubricating oils by electrothermal atomic absorption spectrometry (ET AAS) with Zeeman-effect background correction. Respectively, 1.0, 0.5 and 1.0 ml of surfactants mixture, sample and co-surfactant (sec-butanol) solutions were sequentially aspirated to a holding coil. The sonication and repetitive change of the flowing direction improved the stability of the different emulsion types (oil in water, water in oil and microemulsion). The emulsified zone was pumped to fill the sampling arm of the spectrometer with a sub-sample of 200 μl. Then, 10 μl of this sample solution were introduced by means of air displacement in the graphite tube atomizer. This sequence was timed to synchronize with the previous introduction of 15 μg of Mg(NO3)2 (in a 10 μl) by the spectrometer autosampler. The entire SIA system was controlled by a computer, independent of the spectrometer. The furnace program was carried out by employing a heating cycle in four steps: drying (two steps at 110 and 130 °C), pyrolisis (at 1500 °C), atomization (at 2400 °C) and cleaning (at 2400 °C). The calibration graph was linear from 7.7 to 120 μg Al l−1. The characteristic mass (mo) was 33.2 pg/0.0044 s and the detection limit was 2.3 μg Al l−1. The relative standard (RSD) of the method, evaluated by replicate analyses of different lubricating oil samples varied in all cases between 1.5 and 1.7%, and the recovery values found in the analysis of spiked samples ranged from 97.2 to 100.4%. The agreement between the observed and reference values obtained from two NIST Standard Certified Materials was good. The method was simple and satisfactory for determining aluminum in new and used lubricating oils.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号