首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
ABSTRACT

In this study, a simple and efficient solid phase extraction procedure was developed for simultaneous separation and preconcentration of Ba, Cd, Co, Cu, Mn and Ni. The methodology was based on preconcentration of the target analytes on N,N’-bis(4-methoxysalicylidene)-1,3-propanediamine modified silica gel prior to inductively coupled plasma optic emission spectrometry detection. The experimental conditions were as follows: pH of sample 5.00; sample and eluent flow rates 3 mL min?1; sample volume 25 mL; eluent 0.5 mol L?1 HNO3; eluent volume 3.0 mL. Preconcentration factor was achieved as 33.3 for Ba, Co, Mn; 83.3 for Cd, Ni; 166.7 for Cu. Limits of detection were found as 0.33, 0.26, 0.27, 0.36, 0.27 and 0.19 µg L?1 for Ba, Cd, Co, Cu, Mn and Ni, respectively. The relative standard deviations of 2.6–3.8% were obtained via nine parallel analyses. The suggested procedure was successfully validated by the analysis of TMDA-53.3 Lake Ontario water and ERM-CA022a soft drinking water certified reference materials and applied to various natural water samples.  相似文献   

2.
Extraction and analysis of arsenic in soils and sediments   总被引:1,自引:0,他引:1  
The ability to extract arsenic (As) from soils and sediments, and analyze it with accuracy and precision, is of paramount importance, given the high risk that As, even in relatively low concentrations, poses to pore waters and biota. A large number of methods exist for extracting and analyzing total As, and As associated with a variety of operationally defined phase associations, in soils and sediments. We give an overview of methods used at present, and consider potential problems. We strongly recommend adoption of universal standard techniques and certified reference materials, especially for sequential extraction schemes.  相似文献   

3.
Single and sequential extraction procedures are used for studying element mobility and availability in solid matrices, like soils, sediments, sludge, and airborne particulate matter. In the first part of this review we reported an overview on these procedures and described the applications of chemometric uni- and bivariate techniques and of multivariate pattern recognition techniques based on variable reduction to the experimental results obtained. The second part of the review deals with the use of chemometrics not only for the visualization and interpretation of data, but also for the investigation of the effects of experimental conditions on the response, the optimization of their values and the calculation of element fractionation. We will describe the principles of the multivariate chemometric techniques considered, the aims for which they were applied and the key findings obtained. The following topics will be critically addressed: pattern recognition by cluster analysis (CA), linear discriminant analysis (LDA) and other less common techniques; modelling by multiple linear regression (MLR); investigation of spatial distribution of variables by geostatistics; calculation of fractionation patterns by a mixture resolution method (Chemometric Identification of Substrates and Element Distributions, CISED); optimization and characterization of extraction procedures by experimental design; other multivariate techniques less commonly applied.  相似文献   

4.
Here we present a new method for sequential selective extractions (SSEs) for Hg in geological solids, validated with extensive quality assurance procedures. Mercury was separated into fractions which “make sense” biogeochemically, rather than being identified by specific compounds. Experiments elucidated the effects of extraction time, solids-to-liquid ratio, and alternate solvents in natural samples, reference materials, and pure compounds. Compounds tested included HgS (red and black), HgCl2, Hg0, Hg2Cl2, HgSe, HgO, Hg(II) adsorbed on goethite, Hg-humate, and gold amalgamated Hg. Based on these findings, a five-step sequence of extractions was established to separate the compounds into biogeochemically distinct categories. The fractions and leaching media were as follows: F1 (deionized water), F2 (0.01 M HCl+0.1 M CH3COOH), F3 (1 M KOH), F4 (12 M HNO3), and F5 (aqua regia). Method blanks and method detection limits (MDLs) of 0.1-5 ng/g were obtained for the various analytical fractions, depending on the reagent concentrations used. Precision ranged from 2 to 8% for the major fractions in a sample, but increased to 2-40% for fractions making up <5% of the total. Recovery of total Hg by the sum of species in reference materials showed that the accuracy of the method ranges from 90 to 105%. Methylation potential, determined by anoxic incubation sample aliquots with biologically active sediments, showed that inorganic Hg extracted in the F3 fraction is most strongly correlated with methylation potential. In most natural and sediment incubation samples, the majority of Hg present was found either in the F3 or F5 fractions.  相似文献   

5.
Element mobility and availability in natural solid matrices can be studied with single and sequential extraction procedures; such procedures provide reliable and useful information only if the experiments are correctly planned and executed and the results are properly interpreted. Chemometrics can be a valuable tool for these aims, especially taking into account the large amounts of data generated with extraction essays and the complexity of the processes under investigation. This review deals with the application of chemometrics in research studies involving single and sequential extractions on soils or sediments, for several purposes: the development and optimization of the extraction conditions, the calculation of element fractionation, the visual illustration of the experimental results, the acquisition of different areas of information, including relationships among variables, similarities and differences among samples, causes of the observed behaviour (e.g. source identification), risk assessment, models and predictions of future events. In Part I of the review, following an overview on extraction procedures, the applications of univariate and bivariate chemometric methods are reported; then the principles of multivariate techniques for pattern recognition based on variable reduction, their applications and the main findings obtained are addressed.  相似文献   

6.
Fractionation of the metals Cd, Cr, Cu, Ni, Pb and Zn in sediments was performed for samples collected from eight locations in the Poxim river estuary of Sergipe State, northeast Brazil, using the 3-stage sequential extraction procedure proposed by the European Community Bureau of Reference (BCR). The extraction method was found to be satisfactory for analysis of certified reference material BCR-701, with recovery values ranging from 85% (Cu) to 117% (Cr). The detection limits obtained were 0.001 to 0.305 µg g− 1. Zn exhibited greatest mobility and bioavailability, indicative of anthropogenic sources, while Cr was mainly found in the residual fraction and could be used as an indicator for the contribution from natural sources. Cd, Cu, Ni and Pb were associated with the oxidizable fraction, and Pb, Cr and Ni with the reducible fraction. Principal component analysis (PCA) clearly separated the metals into three groups: I (Zn); II (Pb); III (Cd, Cu, Cr and Ni). These groupings were mainly due to different distributions of the metals in the various fractions, in sediments from the different locations. Risk assessment code (RAC) analysis indicated that although the metals presented a moderate overall risk to the aquatic environment, nickel showed a low risk (RAC < 10%) at three sites, while zinc presented a high risk (RAC > 30%) at four other sites.  相似文献   

7.
The modified BCR three-step sequential extraction procedure has been applied to homogenized urban dust samples and to simulated air filters loaded with the prepared urban dust via the wet deposition procedure. This work has been focused on comparative study of the distribution of trace elements in both samples and evaluation of the factors influencing the reliability of results with respect to the proposed extraction procedure. Extracted chemical fractions were analyzed by ICP-OES and GFAAS depending on the concentration levels of investigated trace elements As, Cd, Cr, Mn, Ni, and Pb, selected according to their adverse effect on the human health. Statistically evaluated results indicate significant differences between the extracted portions of analytes in urban dust and simulated air filters, where the mobility of some analytes in simulated air filters was higher than that in urban dust samples. The impact of surfactant Triton X-100 (0.05 vol. %) on the extraction procedure was also investigated. Presented at the XVIIIth Slovak Spectroscopic Conference, Spišská Nová Ves, 15–18 October 2006.  相似文献   

8.
Sediment samples were taken from the Tisza–Szamos area and Gödöll lake system. A new sequential extraction scheme in a supercritical extractor using supercritical CO2, subcritical H2O, and a subcritical mixture of 90% H2O and 10% CO2 as solvents was employed. This procedure provides relevant information about environmentally mobile heavy metal fractions (water-soluble, bicarbonate-forming) of sediments during a reasonably short time (5 h). The environmental mobility of Zn and Cd was found to be the highest among the sediments involved in these investigations. This mobility represents detectable ecotoxicity, which can be tested with the subcritical water extracts. Performance of pollen tube growth (PTG) test and the ecotoxicological stable isotope metabolic assay (ESIMA) was compared. Potential ecotoxicity of aqueous extracts was reliably detectable by PTG test during a relatively short time (1 day).  相似文献   

9.
Three typical schemes for metal fractionation were applied to analyse coastal surface sediment samples from Bahía Blanca estuary, where an important industrial emplacement is located. Also, three certified reference materials for total metal concentrations were analysed. The studied metals were cadmium, chromium, copper, lead and zinc because of their hazardous potential and related abundance in the estuary. The concentration of metals was determined by inductively coupled plasma-optical emission spectrometry (ICP-OES). A three-way multivariate analysis was performed in order to obtain a better visualization of the experimental data. The extracted information was used to evaluate the equivalence among the results obtained by the three sequential extraction schemes. The data were analysed by parallel factor analysis (PARAFAC). PARAFAC models with two factors describe appropriately the data sets (explained variance about 54% and core consistency of 100%). The multivariate decomposition showed that the three applied schemes are able to describe equally well the behaviour of the metals in the different sediment fractions.  相似文献   

10.
In this work, a fast microwave assisted extraction procedure was developed and optimized for the heavy metals (Cu, Ni, Cr, Pb and Cd) partitioning in the three-stage sequential extraction procedure proposed by the European Standards, Measurements and Testing (SM&;T) Program, formerly the Community Bureau of Reference (BCR). The microwave oven procedure was optimized to obtain extraction efficiencies similar to the conventional BCR procedure, in less time, while using smaller volumes of reagents. In the optimization process, three variables (extraction time, ramping time and microwave power) were considered as factors and as a response the concentration of different metal ions in each individual BCR fraction. Interactions between analytical factors and their optimized levels were investigated using a central composite design. Extractable metals obtained by both comparable methodologies were measured by inductively coupled plasma mass spectrometry. With the use of optimal microwave conditions, steps 1–3 of the sequential extraction (including the hydrogen peroxide digestion in step 3) could be completed between 21 and 22 min. Detection limits were between 1 and 18 ng l− 1. The accuracy of the proposed method was checked with a certified reference material (CRM) of Lake Sediment BCR 701. Values obtained were in accordance with those reported for the certified material with only a few exceptions. Different origin sediments (river and marine) were analyzed by both BCR and MW procedures, and the results obtained were comparable according to the t-paired-test for a 95% confidence level.  相似文献   

11.
A broad range of organic compounds is recognized as environmentally relevant for their potential adverse effects on human and ecosystem health. This method was developed to better determine the distribution of 61 compounds that are typically associated with industrial and household waste as well as some that are toxic and known (or suspected) for endocrine-disrupting potential extracted from environmental sediment samples. Pressurized liquid extraction (PLE) coupled with solid-phase extraction (SPE) was used to reduce sample preparation time, reduce solvent consumption to one-fifth of that required using dichloromethane-based Soxhlet extraction, and to minimize background interferences for full scan GC/MS analysis. Recoveries from spiked Ottawa sand, commercially available topsoil, and environmental stream sediment, fortified at 4-720 μg per compound, averaged 76 ± 13%. Initial method detection limits for single-component compounds ranged from 12.5 to 520 μg/kg, based on 25 g samples. Results from 103 environmental sediment samples show that 36 out of 61 compounds (59%) were detected in at least one sample with concentrations ranging from 20 to 100,000 μg/kg. The most frequently detected compound, beta-sitosterol, a plant sterol, was detected in 87 of the 103 (84.5%) environmental samples with a concentration range 360-100,000 μg/kg. Results for a standard reference material using dichloromethane Soxhlet-based extraction are also compared.  相似文献   

12.
Pengran Guo 《Talanta》2007,71(2):778-783
Sequential extraction procedures were widely applied for speciation of radioactive elements. In this study, the sequential extraction procedure developed by Martínez-Aguirre was employed for quantification of different chemical forms of thorium in the soil. The total amount of thorium in contaminated soil was much higher by four-fold than the local background value. The soil properties affect the amount of thorium and distribution of fractions in contaminated soil. Results showed that the proportion of thorium in soils from Baotou was found as the residual fraction (F5 + F6) > absorbed fraction (F3), coprecipitated fraction (F4) > carbonates fraction (F2) and exchangeable fraction (F1) that could be available to plants. The recovery, calculated by ratio of the sum of the six fractions to the pseudo-total content of thorium, was in the range from 96% to 110%. A comparison was carried out between the sequential extraction and the single extraction to evaluate the selectivity of the extractants. It was found that the amount of thorium of absorbed fraction (F3) was higher in the single extraction than that estimated in the sequential extraction, possibly duo to transform of the labile form. While for non-residual fraction analysis, the single extraction scheme was a desirable alternative to the sequential extraction procedure. According to correlativity analysis of various fractions, it might be predicted that how the non-residual fractions of thorium were directionally transformed into interrelated fractions under the changes of conditions.  相似文献   

13.
ICP-OES和ICP-MS法研究中草药中元素的溶出特性   总被引:1,自引:0,他引:1  
中药中微量元素的含量,尤其是有毒重金属的含量日益引起人们的重视[1].测定中草药原生药金属元素含量的报道较多[2-7],而系统研究煎煮前后微量元素分布的报道较少[8-12].本文选取了常用配方中最常用的十八种中草药,采用电感耦合等离子体原子发射光谱法(ICP-OES)和电感耦合等离子体质谱法(ICP-MS)对其中的Al、Ca、Fe、K、Mg、Mn、Na、Sr、Zn、V、Ni、Cu、Cd和Pb等14种金属元素煎煮溶出的情况进行了初步研究,试图为中药研究提供一些基础数据.  相似文献   

14.
In this work, inductively coupled plasma emission spectroscopy was utilized to directly determine the chemical composition of magnetic fluids constituted of size-sorted ferrite nanoparticles in aqueous solution. Nickel and cobalt nanoferrites were chemically synthesized following a bottom-up route and dispersed under various pH conditions. Size and structural characteristics of nanograins were investigated by X-ray diffraction using a synchrotron source. Chemical analysis was then carried out by directly introducing diluted magnetic fluid samples (slurries) into the spectrometer. To achieve reliable measurements, sample conditions and apparatus parameters were carefully investigated. Slurry stability must be optimized in order to obtain reproducible and accurate analysis. The instrument must also be calibrated to minimize the difference between the signal produced by slurries and that of aqueous ordinary solutions. Furthermore, slurry sample introduction offers many advantages over conventional sample digestion, including reduced sample pretreatment time, less possibility of contamination and the use of direct calibration with aqueous solutions.  相似文献   

15.
The developed and tested method is based on the acid volatile sulphur (AVS) releasing from a sample of sediment by acidification with hydrochloric acid and sequential absorption of released hydrogen sulphide into the absorption solution of sodium hydroxide. Total sulphur absorbed in the absorption solution is subsequently determined by inductively coupled plasma optical emission spectrometry (ICP-OES) technique. The method was tested using both model and real samples of the river sediment. Obtained results were compared with the results of iodometric determination as the method routinely used for the AVS determination. In case of using ICP-OES with purge and trap, there is no spectral interference of calcium; therefore for the determination of sulphur, it is possible to use atomic emission line of sulphur S I 180.7 nm. The tested method provides the results comparable with the iodometric method within the range of tested concentrations. The detection limit (LOD) of this method is 0.09 mg· S2? ? L?1 in the absorption solution which corresponds to 0.23 mg S2?·kg?1 in a sediment. Value of LOD is comparable with the iodometric determination.  相似文献   

16.
The BCR (the Community Bureau of Reference) of the European Union sequential extraction scheme for metal partitioning in estuarine sediments has been accelerated by using a matrix solid phase dispersion (MSPD) approach. The MSPD assisted BCR procedure consists of passing the extractants proposed by conventional BCR protocol (0.11 M acetic acid, 0.1 M hydroxylammonium chloride and 8.8 M hydrogen peroxide plus 1 M ammonium acetate) through the dispersed sample packaged inside a disposable syringe. Different silica-, magnesium- and aluminium-based materials were tested as dispersing agents and sea sand was found to offer the best performances. Variables for assisting the three stages of the BCR protocol were optimized, and accurate results were obtained when assisting the first and the third stages (exchangeable and oxidizable fractions, respectively). However, lack of accuracy was observed when assisting the second step (reducible fraction) and this result agrees with most of the assisted BCR procedures for which extracting the reducible fraction is the most troublesome stage. The organic matter oxidation (third stage) was successfully assisted by passing hydrogen peroxide at 50 °C through the dispersed sample inside de syringe just before passing ammonium acetate. Therefore, the time-consuming and unsafe conventional organic matter oxidation processes, commonly performed even for microwave/ultrasounds assisted BCR procedures, are totally avoided. Inductively coupled plasma-mass spectrometry (ICP-MS) was used as a selective detector. The target elements were Cd, Co, Cr, Mn, Ni, Sr and Zn (first stage), Cd, Co and Ni (second stage), and Co, Cr, Mn, Ni, Sr and Zn (third stage). Repeatability of the method (n = 7) was good, and RSDs values of 9, 10, 10, 8, 8, 3 and 8% was obtained for Cd, Co, Cr, Mn, Ni, Sr and Zn, respectively (first stage); 10, 9 and 9% for Cd, Co and Ni, respectively (second stage); and 6, 2, 3, 4, 7 and 9% Co, Cr, Mn, Ni, Sr and Zn, respectively (third stage). The procedure was also validated by analysing two certified reference materials (CRM 601 and CRM 701). Good accuracy was obtained for the target elements extracted at the first stage: Cd (4.0 ± 0.1 and 7.3 ± 0.09 μg g−1 in CRM 601 and CRM 701, respectively), Cr (0.36 ± 0.008 and 2.21 ± 0.08 μg g−1 in CRM 601 and CRM 701, respectively), Ni (8.0 ± 0.3 and 15.4 ± 0.3 μg g−1 in CRM 601 and CRM 701, respectively) and Zn (262 ± 3 and 203 ± 3 μg g−1 in CRM 601 and CRM 701, respectively). Also, good accuracy was observed for elements extracted at the third step: Cd (1.8 ± 0.09 and 0.29 ± 0.03 μg g−1 in CRM 601 and CRM 701, respectively), Cr (145 ± 4 μg g−1 in CRM 701), Ni (8.2 ± 0.7 and 15.1 ± 0.5 μg g−1 in CRM 601 and CRM 701, respectively) and Zn (45 ± 0.7 μg g−1 in CRM 701).  相似文献   

17.
A novel nonchromatographic speciation technique for the speciation of mercury by sequential cloud point extraction (CPE) combined with inductively coupled plasma optical emission spectrometry (ICP-OES) was developed. The method based on Hg2+ was complexed with I to form HgI42−, and the HgI42− reacted with the methyl green (MG) cation to form hydrophobic ion-associated complex, and the ion-associated complex was then extracted into the surfactant-rich phase of the non-ionic surfactant octylphenoxypolyethoxyethanol (Triton X-114), which are subsequently separated from methylmercury (MeHg+) in the initial solution by centrifugation. The surfactant-rich phase containing Hg(II) was diluted with 0.5 mol L− 1 HNO3 for ICP-OES determination. The supernatant is also subjected to the similar CPE procedure for the preconcentration of MeHg+ by the addition of a chelating agent, ammonium pyrrolidine dithiocarbamate (APDC), in order to form water-insolvable complex with MeHg+. The MeHg+ in the micelles was directly analyzed after disposal as describe above. Under the optimized conditions, the extraction efficiency was 93.5% for Hg(II) and 51.5% for MeHg+ with the enrichment factor of 18.7 for Hg(II) and 10.3 for MeHg+, respectively. The limits of detection (LODs) were 56.3 ng L− 1 for Hg(II) and 94.6 ng L− 1 for MeHg+ (as Hg) with the relative standard deviations (RSDs) of 3.6% for Hg(II) and 4.5% for MeHg+ (C = 10 μg L−1, n = 7), respectively. The developed technique was applied to the speciation of mercury in real seafood samples and the recoveries for spiked samples were found to be in the range of 93.2–108.7%. For validation, a certified reference material of DORM-2 (dogfish muscle) was analyzed and the determined values are in good agreement with the certified values.  相似文献   

18.
An efficient microwave-assisted extraction (MAE) procedure coupled with high performance liquid chromatography–electrospray-ion-trap mass spectrometry (HPLC–ESI-ITMS) has been evaluated to determine hexabromocyclododecane diastereoisomers (α-, β- and γ-HBCD) in marine sediments. The composition of the LC mobile phase (consisting of water, methanol and acetonitrile) and the parameters of electrospray ionization (ESI) were evaluated to obtain chromatographic baseline separation and high sensitivity for the detection of these diastereoisomers. The effects of various operating parameters on the quantitative extraction of the HBCDs through MAE were systematically investigated. The three diastereoisomers were then quantitated by HPLC–ITMS employing ESI operated in the negative ionization mode. The HBCDs were extracted from the sediments through MAE using 40 mL of acetone/n-hexane (1/3, v/v) at 90 °C for 12 min. The limits of quantitation (LOQ) ranged from 25 to 40 pg/g (dry weight) in 5 g of the sediment samples. The recoveries of the HBCDs in spiked sediment samples ranged from 68 to 91% (relative standard derivation: 2–11%). The extraction efficiency of the MAE technique was also compared with Soxhlet extraction and pressurized liquid extraction.  相似文献   

19.
An on-line zinc preconcentration and determination system implemented with inductively coupled plasma optical emission spectrometry (ICP-OES) was developed. The zinc was precipitated and retained on a minicolumn filled with ethyl vinyl acetate (EVA) at pH 9.0, without using any complexing reagent. The zinc ions were eluted from the minicolumn with 10% (v/v) hydrochloric acid. Experimental conditions including pH and sample loading and eluting variables were evaluated and established.An enrichment factor (EF) of 44 was obtained for Zn2+ with a preconcentration time of 120 s. Under the optimal conditions, the value of the limit of detection (3σ) for the preconcentration of 10 mL of sample was 0.08 μg L− 1. The sampling frequency was about 24 h− 1. The precision for six replicate determinations (repeatability conditions) at 50 μg L− 1 Zn level was 3.94% relative deviation standard (RSD), calculated from the peak heights obtained. The methodology was successfully applied to the determination of zinc in tap water samples and in a certified VKI reference material QC Metal LL1 DHI (Water & Environment) Denmark.  相似文献   

20.
In the last few decades, several sequential extraction procedures have been developed to quantify the chemical status of metals in the solid phase. In this study, three extraction techniques (modified [A. Tessier, P.G.C. Campbell, M. Bisson, Anal. Chem. 51 (1979) 844]; [R.C. Stover, L.E. Sommers, D.J. Silvera, J. Water Pollut. Con. F. 48 (1976) 2165]; and the Bureau Communautaire de Reference (BCR) [K.F. Mossop, C.M. Davidson, Anal. Chim. Acta 478 (2003) 111]) were applied to study the distribution of trace (Co, Ni, Zn and Cu) and major (Mn and Fe) elements in two different anaerobic granular sludges from full-scale methanogenic wastewater treatment plants. The Stover scheme displayed a higher number of fractions that induces a poor recovery compared to the other schemes. The sequential extraction scheme recommended by BCR and the modified Tessier scheme gave similar trends and are sufficiently repeatable and reproducible for application in fractionation studies. However, the BCR scheme seems to be of limited utilisation to study anaerobic matrixes because the extraction stage for its reducible fraction may release substantial amounts of trace elements bound to the organic/sulfides fraction, and consequently, the recovery of trace elements in the oxide fraction may be overestimated at the expense of the oxidisable fraction. As a final conclusion, the modified Tessier scheme seems to be the most suitable scheme to study the metal partitioning in anaerobic granular sludges.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号