首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 78 毫秒
1.
Jiang H  Hu B  Jiang Z  Qin Y 《Talanta》2006,70(1):7-13
A new method using a microcolumn packed with YPA4 chelating resin as solid-phase extractor has been developed for the separation and preconcentration of trace Hg prior to its measurement by GFAAS with Pd as a permanent modifier. Various parameters such as the amount of the modifier, pH, sample flow rate, the concentration and volume of eluent have been studied in order to find the best conditions for the determination of mercury. The detection limit of the method (3σ) for Hg based on an enrichment factor of 100 was 0.2 ng ml−1. A characteristic mass of 114 pg was obtained for mercury using Pd as a permanent modifier. The relative standard deviation was 2.8% at the 10 ng ml−1 level (n = 5). The method has been applied to the determination of trace mercury in environmental water samples and the recoveries for the spiked samples are in the range of 91-105%.  相似文献   

2.
A simple, sensitive, low-cost and rapid, flow injection system for the on-line preconcentration of lead by sorption on a microcolumn packed with silica gel funtionalized with methylthiosalicylate (TS-gel) was developped. The metal is directly retained on the sorbent column and subsequently then eluted from it by EDTA. Five variables (sample flow rate, eluent flow rate, eluent concentration, pH and buffer concentration) were considered as factors in the optimization process. Interactions between analytical factors and their optimal levels were investigated using two level factorial and Box-Behnken designs. The optimum conditions established were applied to the determination of lead by flow injection inductively coupled plasma atomic emission spectrometry (FI-ICP-AES). The proposed method has a linear calibration range from 10 to at least 500 ng ml−1 of lead. At a sample frequency of 24 h−1 and a 120 s preconcentration time, the enrichment factor was 41, the detection limit was 15.3 ng ml−1 (S/N=3) and the precision, expressed as relative standard deviation, was 0.9% (at 100 ng ml−1). Validation of the developed method was carried out against electrothermal atomic absorption spectrometry analysis without statistically significant differences between the proposed method and the atomic absorption method.  相似文献   

3.
In this work, two kinds of chelating resin, bis(2-aminoethylthio)methylated resin (BAETM) and γ-aminobutyrohydroxamate resin (γ-ABHX) were synthesized. Of these, the former has a hydrophobic skeleton, and the latter a hydrophilic skeleton. The functionalities of each were 0.91 and 2.21 mmol g−1, respectively. The chelating behavior of these resins towards vanadium, molybdenum and tungsten as a function of pH was studied. To perform trace metals analysis in complex matrices, a hyphenated method-chelation ion chromatography (CIC) coupled on-line detection with inductively coupled plasma mass spectrometry (ICP-MS) was developed. With a BAETM resin column (5×0.4 cm i.d.) as the separator, a sample volume of 20 μl, nitric acid (pH 1.5) as the eluent and a flow rate of 1 ml min−1, the detection limits for the determination of vanadium, molybdenum and tungsten were lower than 0.05 ng ml−1and the linear ranges were up to 100 ng ml−1 for each element. By increasing the injected sample volume to 250 μl, the resin concentrator improved the detection limit to 0.01 ng ml−1. For the determination of these elements (5 ng ml−1 for each) spiked in artificial sea water samples, γ-ABHX resin column (3×0.6 cm i.d.) demonstrated well resolved peak separation between the analytes and the matrix elements—calcium and magnesium, by using sodium nitrate (10 ml, 10−4 M) as the eliminator.  相似文献   

4.
A simple and highly selective flow injection (FI) on-line preconcentration and separation flame atomic absorption spectrometric (FAAS) method was developed for the determinations of trace amounts of silver, gold and palladium. The selective preconcentration of the noble metals was achieved in a wide range of sample acidity (0.1-6 M HNO3 or HCl) on a microcolumn packed with amidinothioureido-silica gel (ATuSG). The analytes retained on the column were effectively eluted with 5.0% thiourea solution. The analytical procedure was optimized for sample acidity, elution, interferences, flow rate of sampling and eluting, and concentration of sample. Common co-existing cations and anions did not interfere with the preconcentration and determination of the three metals. At a sample loading flow rate of 4.5 ml min−1 with 60 s preconcentration, detection limits (3σ) of 1.1 ng ml−1 Ag, 13 ng ml−1 Au and 17 ng ml−1 Pd were obtained. The precisions (R.S.D., n=11) were 1.2% for Ag, 1.2% for Au and 1.7% for Pd, respectively. The detection limits can be further improved by increasing sample volume. The analytical results obtained by the proposed method for a number of standard reference materials were in good agreement with the certified values.  相似文献   

5.
The present article reports on the application of modified multiwalled carbon nanotubes (MMWCNTs) as a new, easily prepared and stable solid sorbent for the preconcentration of trace rhodium ion in aqueous solution. Rhodium ions were complexed with 1-(2-pyridylazo)-2-naphthol (PAN) in the pH range of 3.2-4.7 and then the formed Rh-PAN complex was adsorbed on the oxidized MWCNTs. The adsorbed complex was eluted from MWCNTs sorbent with 5.0 mL of N,N-dimethylformamide (DMF). The rhodium in eluted solution was determined by flame atomic absorption spectrometry (FAAS). Linear range for the determination of rhodium was maintained between 0.16 ng mL−1 and 25.0 μg mL−1 in initial solution. Relative standard deviation for the 10 replicated determination of 4.0 μg mL−1 of rhodium was ±0.97%. Detection limit was 0.010 ng mL−1 in initial solution (3Sbl, n = 10) and preconcentration factor was 120. Sensitivity for 1% absorbance of rhodium (III) was 0.112 μg mL−1. The sorption capacity of oxidized MWCNTs for Rh (III) was 6.6 mg g−1. The effects of the experimental parameters, including the sample pH, flow rates of sample and eluent solution, eluent type, breakthrough volume and interference ions were studied for the preconcentration of Rh3+. The proposed method was successfully applied to the extraction and determination of rhodium in different samples.  相似文献   

6.
A method for the simultaneous preconcentration and determination of Hg(II) and MeHg(I) at the ng ml−1 level has been developed. This method is based on solid phase extraction using a newly synthesized chelating resin containing nitrogen and sulphur donor sites of the 1,2-bis(o-aminophenylthio)ethane moiety that is very selective for mercury. The characterization of the resin has been carried out by elemental analyses, infrared spectral data, thermogravimetric analysis and metal ion capacities. The resin is highly selective for Hg(II) and MeHg(I) with an exchange capacity of 0.38 and 0.30 mmol g−1, respectively. Various parameters like pH, column flow rate, desorbing agents are optimized. Cold vapour atomic absorption spectrometry (CVAAS) was used to measure the concentration of both species of mercury. The calibration graph was linear upto 10 ng ml−1 with a 3σ detection limit of 0.09 ng ml−1. The recovery of Hg(II) and MeHg(I) was found to be 98.9±2.0 and 98.0±1.1%, respectively. The method has been used for routine determination of trace levels of mercury species in natural waters to comply with more stringent regulations.  相似文献   

7.
A sensitive procedure has been developed for selenium and tellurium determination in milk by hydride generation atomic fluorescence spectrometry (HG-AFS) after microwave-assisted sample digestion. The method provides sensitivity values of 1591 and 997 fluorescence units ng−1 ml−1 with detection limits of 0.005 and 0.015 ng ml−1 for Se and Te, respectively. The application of the developed methodology to the analysis of cow milk samples of the Spanish market evidenced the presence of concentration ranges from 11.1 to 26.0 ng ml−1 for Se, and from 1.04 to 9.7 ng ml−1 for Te having found a good comparability with data obtained after dry-ashing of samples.  相似文献   

8.
The use of a flow through solid phase terbium-sensitized luminescence system is described for the determination of the widely used fluoroquinolone norfloxacin. A chelate between the terbium ion and the analyte is formed online previously to the sample injection into the carrier stream. Then the chelate is transported towards the flow-through cell, where it is retained on a cationic Sephadex resin packed in the cell, developing the corresponding luminescence signal. Afterwards, an ethylenediaminetetraacetic acid solution was used as eluting agent, in order to regenerate the sensing zone. The system has been satisfactorily applied to the determination of norfloxacin in human urine and serum, without the need of a pre-treatment. The response was linear in the range 10-150 ng ml−1. The detection and quantification limits were 1.5 and 5 ng ml−1, respectively and the R.S.D. 1.82%.  相似文献   

9.
2-Pyridine carboxaldehyde furfuralhydrazone (PCFH) was newly synthesized and its ionization, IR and elemental analysis were established. An on-line separation and preconcentration system was developed for the flow injection (FI) catalytic kinetic spectrofluorimetric determination of trace amounts of gold. The method was based on the fluorescence enhancing reaction of PCFH with potassium bromate, which was catalysed by Au3+ in aqueous medium at pH 4.20 and 35 °C. A micro polyamide resin column was used to separate and collect gold from sample solution. Under these experimental conditions, the oxidized product of PCFH had excitation and emission maxima at 296 and 404 nm, respectively. The linear range of this method was 0.53-144 ng ml−1 with the RSD of 1.6%. The detection limit was 0.16 ng ml−1. A high analysis rate of 15 samples h−1 was obtained. The proposed method had been applied successfully to the determination of gold in synthetic mixture and mineral sample with satisfactory results.  相似文献   

10.
A sensitive and simple solid-phase preconcentration procedure for enrichment of cadmium prior to analysis by flame atomic absorption spectrometry (FAAS) is described. The method is based on the adsorption of cadmium as CdI42− on naphthalene-methyltrioctylammonium chloride adsorbent, elution by nitric acid and subsequent determination by FAAS. The effect of pH, iodide concentration, sample flow rate, volume of the sample and diverse ions on the recovery of the analyte was investigated and optimum conditions were established. A preconcentration factor of 40 was achieved using the optimum conditions. The calibration graph was linear in the range 1-100 ng ml−1 cadmium in the initial solution. The detection limit based on the 3Sb criterion was 0.6 ng ml−1 and the relative standard deviations (RSD) were 3.9 and 1.05% for 5 and 40 ng ml−1, respectively (n=8). The method was successfully applied to the determination of cadmium added to river, tap and Persian Gulf water samples.  相似文献   

11.
A highly sensitive and relatively interference-free spectrophotometric method for determination of calcium is described. The method is based on the reaction between calcium ions and carboxyazo-p-CH3 in aqueous citrate medium of pH 7, to form a blue complex with maximum absorption at 716 nm. The calibration is linear up to 0.12 μg ml−1 calcium with a repeatability (R.S.D.) of 1.0% at a concentration of 0.04 μg ml−1 (n=5). The molar absorptivity of the complex and Sandell’s sensitivity are 3.5×105 l mol−1 cm−1 and 0.11 ng cm−2, its 10σ limit of quantification and the 3σ limit of detection were found to be 0.3 ng ml−1 and 0.09 ng ml−1 respectively. The influence of reaction variables and the effect of interfering ions are studied; no interference was observed in clinical samples. The proposed method has been applied directly to the determination of calcium in clinical samples without the need for pre-concentration, masking metal ions and digesting samples.  相似文献   

12.
A sensitive and selective phosphorimetric method for the determination of 1-naphthaleneacetic acid (1-NAA) based on a flow-injection system connected to a flow cell packed with a solid support and placed in the sample compartment of a conventional luminescence spectrometer is described. A non-ionic solid polymeric resin Amberlite XAD-7 is used for the packing. After injection of the sample, 1-NAA is on-line retained in the packed resin and measurements of the heavy atom induced (HAI)-room temperature phosphorescence (RTP) emission (λex/λem = 292/490 nm) from this native luminescent compound are taken.The optimum experimental conditions were investigated by injecting 2 ml samples of an aqueous solution of 1-NAA in the flow system. A concentration 0.15 mol l−1 of thallium(I) ions, as heavy atom, both in the samples and the carrier flow, was finally selected. Also, a concentration of 6 mmol l−1 of sulphite was optimal for ensuring the necessary deoxygenation of the system at the selected flow rate of 0.8 ml min−1. After measurement, the solid support was efficiently regenerated by injecting 1 ml of a mixture water:acetone in a ratio 1:1 (v/v) into the flow.The detection limit (3σ criterion) was 1.2 ng ml−1 of 1-NAA. The repeatability (R.S.D.) for five replicates of a sample containing 50 ng ml−1 of analyte turned out to be ±3% and the calibration graphs proved to be linear up to 500 ng ml−1 of 1-NAA (maximum concentration assayed). The effect of potential interferences from other organic species which can be also used as plant growth regulators, as well as from various inorganic cations and anions, has been investigated as well.The method was successfully applied to the determination of low levels of this plant growth regulator in natural waters (river and fountain waters) and apples.  相似文献   

13.
Sun Y  Tang Y  Yao H  Zheng X 《Talanta》2004,64(1):156-159
A sensitive flow injection chemiluminescence (FL-CL) method for the determination of cephalosporin antibiotics, was developed. The method was based on that cephalosporin antibiotics could enhance the CL reaction of glyoxal and KMnO4 in sulfuric acid. Method development included the optimization of reagent concentrations and flow-rate. Under the optimized conditions, three cephalosporin antibiotics: cefalexin, cefadroxil, and cefazolin sodium, were determined. The detection limits of the method are 10 ng ml−1 cefalexin, 2 ng ml−1 cefadroxil, and 2 ng ml−1 cefazolin sodium. The method was successfully applied to the determination of three cephalosporin antibiotics in pharmaceutical preparations.  相似文献   

14.
This paper presents two easy and selective methods for determining the active principles nafronyl (NFL) and naproxen (NAP), using a flow-through fluorescence optosensor based on the on-line immobilization on a nonionic-exchanger (Silica Gel, Davisil™ and Amberlite XAD 7, respectively) solid support. The determination was performed in 5×10−3 M HAc/NaAc buffer solution at pH 5 for NFL and 15×10−3 M glycine/HCl buffer solution at pH 2.5 for NAP at a working temperature of 20 °C. The fluorescence intensities were measured at λex/em=294/336 nm and λex/em=332/354 nm for NFL and NAP, respectively. The response time for these optosensors were practically instant, obtaining a linear concentration range between 0 and 700.0 ng ml−1 with a detection limit of 20.8 ng ml−1, an analytical sensitivity of 10.1 ng ml−1 and a standard deviation of 1.27% at a 500 ng ml−1 concentration level for NFL and a linear concentration range between 0 and 200.0 ng ml−1 with the detection limit of 13.3 ng ml−1, an analytical sensitivity of 6.0 ng ml−1 and a standard deviation of 3.52% at a 100 ng ml−1 concentration level for NAP. The proposed methods were satisfactorily applied to real samples (three commercial formulations and urine samples). The effects of the possible interferences were evaluated in all cases.  相似文献   

15.
Yoon KH  Lee SY  Jang M  Ko SH  Kim W  Park JS  Park I  Kim HJ 《Talanta》2005,66(4):831-836
A simple, fast and sensitive high-performance liquid chromatography (HPLC)-electrospray ionization (ESI) tandem mass spectrometric method (LC-MS/MS) has been developed for determination of propiverine and propiverine N-oxide metabolite in human plasma using oxybutynin as internal standard. Instead of extracting propiverine from plasma using organic solvents, which should be separated from the aqueous phase and evaporated before injecting the sample into the chromatograph, plasma sample containing propiverine and N-oxide was directly injected after precipitating proteins with acetonitrile. Numerous compounds in the plasma did not interfere with the highly specific multiple reaction monitoring in tandem mass spectrometric detection following C8 reversed-phase chromatographic separation under conditions that eluted propiverine, N-oxide and oxybutynin within 2 min (0.1% formic acid in water/acetonitrile, 25:75, v/v). The LC-MS/MS method and an alternative LC-MS method, using methyl-t-butyl ether extraction and selected ion monitoring, were validated over 1-250 ng ml−1 of propiverine and 2 to 500 ng ml−1 of N-oxide, and successfully applied in a pharmacokinetic study. The lower limit of quantitation was 1 ng ml−1 for propiverine and 2 ng ml−1 for N-oxide in both methods.  相似文献   

16.
A new chelating resin is prepared by coupling Amberlite XAD-4 with metaphenylendiamine through an azo spacer, characterized (elemental analysis, IR and thermogravimetric analysis (TGA)) and studied for preconcentration Rh (III) using Inductive Couple Plasma Atomic Emission Spectroscopy (ICP-AES) for rhodium monitoring. The optimum pH value for sorption of the metal ion was 6.5 (recovery 100%). The sorption capacity was found 0.256 mmol g− 1 of resin for Rh (III). The method has a detection limit and limit of quantification of 0.05 and 0.08 μg mL− 1 at pH 6.5, respectively. The chelating resin can be reused for 10 cycles of sorption-desorption without any significant change in sorption capacity. A recovery of 100% was obtained for the metal ion with 1.5 M HCl as eluting agent. The equilibrium adsorption data of Rh (III) on modified resin were analyzed by Langmuir and Freundlich models. Adsorption data were modeled using the pseudo-first-order, pseudo-second-order and intra-particle diffusion kinetics equations. Isotherms have also been used to obtain the thermodynamic parameters such as free energy, enthalpy and entropy of adsorption. The positive value of the enthalpy change (2.48 kJ/mol) indicates that the adsorption is an endothermic process. The method was applied for rhodium ions determination from tap water sample.  相似文献   

17.
Fenitrooxon [O,O-dimethyl-O-(4-nitro-m-tolyl)phosphate] is the major metabolite of the organophosphorus insecticide fenitrothion, and 3-methyl-4-nitrophenol is its major degradation product. In the present study, we describe the development of an indirect competitive enzyme-linked immunosorbent assay (ELISA) for the detection of these compounds in water samples based on a group-specific polyclonal antiserum generated with a “bifunctional hapten”, which has two functions: the conventional function of producing an antibody against an antigen and a unique function of promoting the production of the antibodies in rabbit. For application to water samples, the influence of several factors such as organic solvent, pH, and detergent was studied. Under optimized conditions, the quantitative working range of the fenitrooxon ELISA was 0.71-27 ng ml−1 with a limit of detection (LOD) of 0.32 ng ml−1, and the fenitrooxon concentration giving 50% reduction of the maximum signal (IC50) was 4.2 ng ml−1. The quantitative working range of the 3-methyl-4-nitrophenol ELISA was 0.67-27 ng ml−1 with a LOD of 0.38 ng ml−1 and an IC50 of 3.7 ng ml−1. No significant matrix effect originating from the water sample (river water, tap water, purified water, and bottled water) was shown by addition of Tween 20 to the assay buffer. Water samples spiked with each of these compounds at 1, 5, 10, and 20 ng ml−1 were directly analyzed without extraction and clean-up by the proposed ELISA. The mean recovery was 100.9%, and the mean coefficient of variation (CV) was 7.7% for the fenitrooxon ELISA and for the 3-methyl-4-nitrophenol ELISA, the mean recovery was 97.6%, and the mean CV was 7.2%. The proposed ELISA allows precise and accurate determination of these compounds in water at such low levels.  相似文献   

18.
A simple and sensitive kinetic method for the determination of traces of mercury (70-760 ng ml−1) based on its inhibitory effect on the addition reaction between methyl green and sulfite ion is proposed. The reaction was monitored spectrophotometrically by measuring the decrease in absorbance of methyl green at 596 nm between 2 and 4 min using a fixed time method. Artificial neural networks with back propagation algorithm coupled with an orthogonal array design were applied to the modeling of the proposed kinetic system and optimization of experimental conditions. An orthogonal design was utilized to design the experimental protocol, in which pH, concentration of sulfite, temperature, and concentration of methyl green were varied simultaneously. Optimum experimental conditions in term of sensitivity were generated by using ANNs. The rate of decrease in absorbance is inversely proportional to the concentration of Hg(II) over entire concentration range tested (100-550 ng ml−1) with a detection limit of 45 ng ml−1 and a relative standard deviation at 200-400 ng ml−1 Hg(II) of 3.2% (n=5). A simple preconcentration step improved the limit of detection and linear dynamic range of the method to about 8 and 12-760 ng ml−1, respectively, by about 10 times enrichment of mercury between 12 and 75 ng ml−1. The method was based on enrichment of Hg(II) from dilute samples on an anionic ion exchanger fixed on a plastic strip and was applied to the determination of Hg(II) in environmental samples with satisfactory results.  相似文献   

19.
Pourreza N  Mousavi HZ 《Talanta》2004,64(1):264-267
A sensitive and selective preconcentration method for the determination of trace amounts of iron by atomic absorption spectrometry has been developed. Iron forms a complex with methylthymol blue at pH=3. This complex is retained by naphthalene tetraoctylammonium bromide adsorbent in a column with a height of about 2 cm. The adsorbed metal complex is then eluted from the column with nitric acid and its iron content is determined by flame atomic absorption spectrometry (FAAS). The effect of different variables such as pH, reagent concentration, flow rate and interfering ions on the recovery of the analyte was investigated. The calibration graph was linear in the range 25-350 ng ml−1 of iron in the initial solution with r=0.9994. The limit of detection based on 3Sb criterion was 12 ng ml−1 and the relative standard deviation for eight replicate measurements of 150 and 300 ng ml−1 of iron was 3.1 and 1.8%, respectively. This procedure was successfully applied to the determination of iron in tap and sewage water samples.  相似文献   

20.
《Analytica chimica acta》2004,514(2):259-264
A very sensitive fluorimetric method for the determination of menadione using a flow injection system is proposed. The method is based on the on-line reduction of menadione in dodecylsulphate micelles upon irradiation with UV light. The strong fluorescence of the reduced menadione in micellar medium is measured at 410 nm with excitation at 340 nm. The method shows a linear range between 2.42 and 245 ng ml−1 and a limit of detection of 0.18 ng ml−1. The sample throughput was 90 injections per hour. The applicability of the assay was demonstrated by analysing this vitamin in commercial pharmaceutical preparations.  相似文献   