首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 156 毫秒
1.
隋凯  李军  郑江 《分析试验室》2006,25(1):99-102
建立了玉米和小麦中玉米赤霉烯酮(ZEN)的多功能柱净化-高效液相色谱检测方法。样品经乙腈-水混合溶剂(V(乙腈):V(水)=84:16)提取,通过多功能净化柱(MFC)进行一次性净化,以Symmetry^R C18柱为分离柱,甲醇-水(V(甲醇):V(水)=68:32)为流动相进行高效液相色谱分离和检测。玉米赤霉烯酮的质量浓度在0.01~4.0μg/mL范围内呈良好线性,相关系数为0.9996。检出限为0.04μg/g,在0、04—5.0mg/kg添加范围内的回收率为87.5%~98.6%,相对标准偏差为1.5%~8.3%。  相似文献   

2.
建立了小麦中雪腐镰刀菌烯醇(NIV)和脱氧雪腐镰刀菌烯醇(DON)的高效液相色谱同时检测方法。样品采用乙腈-水(体积比85:15)混合溶剂进行提取.通过多功能净化柱(MFC)进行一次性净化,以C18柱为分离柱,水-乙腈-甲醇(体积比90:5:5)混合溶剂为流动相进行高效液相色谱分离和检测。在小麦样品中,本方法在0.2~5μg/g添加范围内的凹收率为87%~99%;相对标准偏差为1.5%~8.3%;DON和NIV的检出限分别为0.12和0、16μg/g(5/N=3)。  相似文献   

3.
提出一种直接进样测定大鼠血浆中舒必利浓度的高效液相色谱方法,使用限进介质色谱柱作为预柱在线去除血浆蛋白后,将舒必利通过柱切换转移到分析柱中进行分析。限进介质色谱柱为CAPCELLPAKMFSCX阳离子交换柱(20×4.0mmi.d.,5μm),分析柱为Kromasil C18柱(150×4.6mm i.d.,5μm),限进介质柱预分离时流动相为PH=6.88的50mmol/L磷酸盐缓冲液乙腈(100:5,V/V),切换后分析流动相为PH=6.83的50mmol/L磷酸盐缓冲液-乙腈(100:10,V/V)。流速均为1mL/min,检测波长为240nm。该方法检出限为17ng/mL,定量限为50ng/mL。舒必利在50~1400ng/mL之间线性良好(r=0.9997),高中低浓度的日内、日间相对标准偏差分别为1.5%~4.2%及2.0%~5.2%,方法回收率为98.8%~104.1%.  相似文献   

4.
隋凯  李军  卫锋  赵守成 《分析化学》2005,33(11):1643-1646
建立了谷物中脱氧雪腐镰刀菌烯醇DON的高效液相色谱检测和质谱确证方法。样品用水提取,通过免疫亲和柱进行富集和净化,以Hypersil BDS C18柱为分离柱,乙腈-水(10:90,V/V)混合溶剂为流动相进行高效液相色谱分离和检测,利用大气压化学电离质谱(APCI)进行阻性结果的鉴定和确认。在小麦、大麦和面粉等样品中,本方法在0.1~10μg/g添加范围内的回收率为82.4%-103%,相对标准偏差1.4%-7.6%,检出限0.1μg/g。  相似文献   

5.
建立了香连丸及组方药材中药根碱、巴马汀、小檗碱、木香烃内酯和去氢木香内酯的含量测定方法.采用反相高效液相色谱,Hypersil ODS(5μm,4.6mm×250mm)色谱柱,流动相为乙腈:水(70:30,V:V),流速1.0mL/min,柱温30℃,检测波长为210n/n测定木香烃内酯和去氢木香内酯的含量;采用高效液相胶束色谱,Kromasil ODS(5la,m,4.6mm×150mm)色谱柱,流动相为0.2mol/LNaH2P04水溶液:7.00mmol/L十二烷基硫酸钠:乙腈(35:35:30,V:V:V),流速1.0mL/min,柱温30℃,检测波长为350nm测定药根碱、巴马汀、小檗碱的含量.结果显示5种活性成分在适当的线性范围内均具有良好的线性关系(r大于0.9993),平均回收率在87.67%~102.37%之间,RSD小于3.13%;结果表明方法简便、灵敏、准确,重现性好.  相似文献   

6.
用HPLC—ESI-TOFMS建立了快速灵敏检测尿中雌二醇的方法,尿样中雌二醇经盐酸水解后用OASISHLB小柱萃取.色谱柱为XTerraMS C18反相分离柱(3.5μm,2.1mm×100mm),流动相为水和乙腈,梯度洗脱,流速为0.2mL/min,紫外检测波长为280nm,外标法定量.质谱采用负离子电离模式.线性方程:y=1.79×10^5x+2.59×10^4,线性范围:0.0328—32.8mg/L,线性相关系数R^2=0.9979,最小检出浓度0.00328mg/L,萃取回收率101.83%.应用本方法对10例正常人尿样进行测定,结果满意.相比较其它检测尿中雌二醇的方法来说,此法比较简单、快速、准确,为临床的诊断提供有价值的指标.  相似文献   

7.
何娟  常使标  刘澎  郭瑞云  林素凤  邝爱燕 《色谱》1999,17(4):393-394
采用高效液相色谱法测定了萨拉沙星。色谱柱为μ-BondapakTMC18柱(3.9mm×300mm),流动相为V(乙腈):V(甲醇):V(2mmol/L磷酸,用三乙胺调pH3.5)=30:5:65,用二极管阵列检测器检测,检测波长278nm,得到了满意的分离效果。  相似文献   

8.
采用高效液相色谱法(HPLC)同时测定快安抗感冒液中对乙酰氨基酚、咖啡因、盐酸甲基麻黄碱、马来酸氯苯那敏和愈创木酚甘油醚的含量。色谱柱为NOVA-PAKC_18柱,流动相为V(已腈):V(0.03mol/L磷酸氢二铵):V(0.004mol/L庚烷磺酸钠):V(三乙胺)=12:44:43.5:0.5,并用磷酸调节pH值至3.0;检测波长220nm,柱温35℃。在此色谱条件下,各组分均获得良好分离。平均回收率为98.0%~100.3%,相对标准偏差小于1.8%。  相似文献   

9.
高效液相色谱法同时测定快安抗感冒液中5种组分的含量   总被引:3,自引:0,他引:3  
王勇 《色谱》1999,17(3):268-270
 采用高效液相色谱法(HPLC)同时测定快安抗感冒液中对乙酰氨基酚、咖啡因、盐酸甲基麻黄碱、马来酸氯苯那敏和愈创木酚甘油醚的含量。色谱柱为NOVA-PAKC_18柱,流动相为V(已腈):V(0.03mol/L磷酸氢二铵):V(0.004mol/L庚烷磺酸钠):V(三乙胺)=12:44:43.5:0.5,并用磷酸调节pH值至3.0;检测波长220nm,柱温35℃。在此色谱条件下,各组分均获得良好分离。平均回收率为98.0%~100.3%,相对标准偏差小于1.8%。  相似文献   

10.
提出了同时测定人血浆中的西诺沙星和萘啶酸的高效液相色谱方法。采用反相C18柱、254nm紫外检测,乙腈-甲醇-0.01mol/L草酸(30:5:65,V/V;pH4.55)体系,实现了二者的良好分离。分别考察了磷酸缓冲溶液和草酸缓冲溶液作为流动相弱溶剂,结果草酸缓冲溶液能有效改善峰形、降低检测限。在不同pH值(pH2.80,4.08,4.55)进行了实验,pH4.55获得最佳分离,最低检测量分别为0.14ng(西诺沙星)和0.24ng(萘啶酸),比文献报道的同类药物最低检测量低10倍。  相似文献   

11.
建立了快速溶剂萃取-离子色谱法(ASE—IC)测定茶叶中的9种有机酸。优化了ASE苹取条件,以水为萃取溶剂,80℃下萃取5min,循环两次。采用Ionpac AS11HC柱分离,KOH溶液梯度洗脱,流速1,0mL/min,抑制电导检测。9种有机酸的检出限为0.009-0.160μg/mL,线性范围为0.5—10μg/mL,相关系数大于0.999,加标回收率为93.4%-99.2%,相对标准偏差为1.4%-4.1%。  相似文献   

12.
The homogeneous ionic liquid microextraction was applied to the extraction of hormones from cosmetics and the hormones were determined by high-performance liquid chromatography. 1-Hexyl-3-methylimidazolium tetrafluoroborate was used as extraction solvent. Ammonium hexafluorophosphate as used as ion-pairing agent. Several experimental parameters, including the volume of 1-hexyl-3-methylimidazolium tetrafluoroborate, amount of ammonium hexafluorophosphate and sodium chloride, extraction and centrifuge time, and the pH value, were optimized. The limits of detection and quantification for the analytes ranged from 0.03 to 0.24 ng/mL and from 0.10 to 0.79 ng/mL, respectively. The precision for determining the hormones was lower than 5.2%. The proposed method was successfully developed for the determination of hormones in real cosmetic samples.  相似文献   

13.
A simple,fast,sensitive,highly selective and eco-friendly analytical method for the determination of catecholamines in human urine by ion chromatography(IC) with chemiluminescence(CL) detection was described in this paper.Using 12 mmol/L H2SO4 without any organic additive as eluent,three catecholamines including epinephrine(EP),norepinephrine(NE) and dopamine(DA) were well separated on a cation-exchange column.The CL detection was based on the reaction of analytes with acidic potassium permanganate in the presence of formaldehyde as an enhancer.The absence of methanol and acetonitrile in eluent made the proposed method more sensitive and eco-friendly.Under the optimal conditions,the linear range of the proposed method was in the range of 0.02-0.5μg/mL.The limit of detection(LOD) was in the range of 0.6 and 5.1μg/L.The relative standard deviations (RSD) for 0.1μg/mL mixed standard solution were in the range of 0.8-1.9%(n = 11).The method has been applied to the determination of catecholamines in human urine successfully.Excellent spiked recoveries were achieved for catecholamines ranged from 91.2%to 112.7%.  相似文献   

14.
建立了固相萃取、高效液相色谱与电感耦合等离子体质谱联用技术测定水中烷基汞的方法。对固相萃取、高效液相色谱和电感耦合等离子体质谱的实验条件进行了优化。在优化条件下,甲基汞和乙基汞的检出限分别为0.5,0.7 ng/L。对地表水、工业废水和生活污水3种水样分别加标10.0,50.0 ng/L进行测定,测定结果的相对标准偏差为3.3%~9.6%(n=6),加标回收率在81.0%~103.0%之间。该方法灵敏度高,实用性强。  相似文献   

15.
气相色谱-质谱法检测动物肌肉组织中残留的甾类同化激素   总被引:13,自引:0,他引:13  
陈捷  秦燕  张美金 《色谱》2006,24(1):19-22
建立了不同动物肌肉中甾类同化激素残留的气相色谱/质谱(GC/MS)检测方法。样品经酶解、组织捣碎和超声提取后,用叔丁基甲醚萃取和反相固相萃取柱净化,进一步衍生后进行GC/MS分析,分别测定雄激素(表睾酮(ETS)、丙酸睾酮(PTS)、19-去甲基睾酮(17β-NT)、甲基睾酮(MTS))和雌激素(雌二醇(17β-ES)、雌三醇(EST)、炔雌醇(EES)、雌酮(ESN)、苯甲酸雌二醇(BES))。实验结果表明,ETS、17β-NT、MTS、PTS、BES、ESN、17β-ES、EES和EST的定量检测限为1.0~2.0 μg/kg。在2.0 μg/kg的定量检测低限添加水平,上述9种激素的平均回收率为62.5%~80.5%,相对标准偏差为12.5%~26.8%。该法可实现对样品进行灵敏、准确的定性定量分析。  相似文献   

16.
采用溶胶凝胶聚甲基苯基乙烯基硅氧烷萃取头萃取饮料中山梨酸和苯甲酸,用直接固相微萃取与气相色谱联用进行测定,通过试验确定了萃取时间、酸度等萃取条件。山梨酸和苯甲酸的浓度在0.2~40μg/mL范围内与色谱峰面积呈良好的线性关系,相关系数分别为0.9988,0.9989,检出限分别为0.0332,0.00320μg/mL,饮料样品和加标样品测定结果的相对标准偏差为4.18%~7.03%(n=3),两个添加水平的加标回收率为80.5%~96.5%。该方法灵敏度比传统的液–液萃取气相色谱法高。  相似文献   

17.
建立了强化食品(饮料、奶粉、含乳饮料、大米、果泥及果冻)中维生素C含量的高效液相色谱检测方法。优化了样品处理方法,在水浴控温和避光条件下处理样品,避免维生素C被氧化。选用Tech Mate C18–ST(250 mm×4.6 mm,5μm)反相色谱柱,以0.05 mol/L磷酸二氢钾缓冲溶液(p H 3)为流动相,流量为1.0m L/min,检测器为光电二极管阵列检测器,检测波长为266 nm。线性范围为0.2~100μg/m L,相关系数为0.999 6,果泥中维生素C的定量限为20 mg/kg,其它为100 mg/kg,加标回收率为82.2%~107%,测定结果的相对标准偏差为1.23%~6.86%(n=8)。该方法简单快速,其灵敏度、准确度和精密度均能满足强化食品中维生素C的检测要求。  相似文献   

18.
极谱法和原子吸收光谱法快速分析矿石中的锑   总被引:1,自引:0,他引:1  
建立了用极谱法和原子吸收光谱法测定矿石中含锑量为0.00X%~XX%的锑的快速分析方法,使锑在H2SO4(2%)-HCl(10%)体系中,既可以用极谱法测定,也可用原子吸收光谱法测定,两种方法测锑的定量线性范围均为:0~30μg/mL;检出限(3 N/S):极谱法为0.01μg/mL,原子吸收法为0.1μg/mL。方法加标回收率在98%~110%;相对标准偏差RSD(n=6)在1.5%~5.0%。方法快速简便,高效准确,已用于锑矿的采、选、冶生产过程控制分析,效果良好。  相似文献   

19.
建立高效液相色谱同时测定黄酒中安赛蜜、苯甲酸、山梨酸和糖精钠4种非法食品添加剂的方法。黄酒中的待测物质经提取后,采用C18柱分离,以甲醇–乙酸铵溶液为流动相进行洗脱,在波长230 nm处用高效液相色谱–二极管阵列检测器进行测定。安赛蜜、苯甲酸、山梨酸和糖精钠的质量浓度在0.5~200.0μg/mL范围内与其色谱峰面积的线性关系良好(r0.999 7),检出限为0.29~0.74μg/L。在0.5,1.0,2.5,5.0,7.5 mg添加水平时的平均回收率在95.6%~104.0%范围内,测定结果的相对标准偏差为0.3%~1.5%(n=6)。该方法操作简便,分离效果好,灵敏度高,结果稳定可靠,适合于黄酒中安赛蜜、苯甲酸、山梨酸和糖精钠的同时测定。  相似文献   

20.
A sensitive method based on a geometry-independent neutral desorption (GIND) in combination with extractive electrospray ionization mass spectrometry (EESI-MS) has been developed for fast detection of illicit additives such as sulfonamides and hormones in highly viscous cosmetic products. The method gave a low limit of detection (LOD) (in the range of 0.001-1 ng/g), acceptable relative standard deviation (RSD=6.8-11.4%) and reasonable recovery (87-116%) for direct measuring of nine types of hormones and sulfonamides in the cosmetic products. The average measurement time for two types of samples was less than 1 min. Trace amounts of analytes in commercial cosmetic products have been quantitatively detected, without any sample pretreatment. The experimental results showed that non-volatile illicit additives such as sulfonamides and hormones could be sensitively liberated using the GIND device for quantitative detection from the highly viscous cosmetic products, demonstrating that GIND-EESI-MS is a promising tool for high throughput, sensitive and quantitative analysis of highly complex viscous samples.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏