首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
Standards for instrumental neutron activation analysis (INAA) of biological materials are proposed. The standards are multielement solid solutions in phenol-formaldehyde resole resin (PFR) moulded as pellets weighing 30 to 50 mg. The concentrations of trace elements in the standards are selected so that, firstly, they are commensurable with their concentrations in the biological materials and, secondly, that the analytical lines of each of the elements incorporated in PFR are resolved with the aid of modern equipment. The principal standard contains 21 trace elements from among those of greatest interest for INAA of biological materials. This standard is recommended for work on high-resolution equipment. At the same time, standards of simpler trace element composition have been prepared and studied which can be used in work on simpler equipment or in solving particular problems in determination of certain groups of chemical elements.  相似文献   

2.
Lichen (species Trypethelium Eluteriae) is analysed for different elements. Nondestructive instrumental neutron activation analysis is employed for the multielemental analysis. Gamma-ray spectrometry is used for the identification and quantitative estimation of elements. Concentrations of 24 elements are reported. Gamma-ray spectrum of the lichen irradiated for 16 hours, delayed for 10 days, and counted for 10 hours on a 50 cm3 coaxial Ge(Li) detector is given.  相似文献   

3.
Neutron activation, applied to silver and copper based coinage, leads to a measure of the mean concentrations of major and 12 trace elements, even if their distribution is heterogeneous. The drawbacks of this activation method applied to such a matrix are shielding effects and high radioactivity of major elements. Both effects were avoided by accurately calculating the correction coefficients and by choosing the optimal working conditions. Analytical results obtained lead to a better knowledge of the chronology and origin of Armorican protohistorical coinage.  相似文献   

4.
Instrumental neutron activation analysis /INAA/ technique has been applied to a water sample to determine the elemental concentrations. The sample was irradiated with a neutron flux of 1.2×1012 n cm–2 s–1 for two different periods followed by counting at three different decay times, using two coaxial type high-resolution Ge/Li/ detectors. The dominant elements determined in the water sample are Ca, Cl, Na, Mg, and K present in ppm-level while Co, I, Mn, Sm, and Sb are present in smaller amounts, approximately on the average 0.01 ppm. Only traces of other elements such as the rare-earth elements, Ag, As, Ba, Cu, Cd, Fe, Sr, W, Zn, seem to be present in the water sample.  相似文献   

5.
Multielemental analysis of an iron ore from the Kingdom of Saudi Arabia was carried out using Instrumental Neutron Activation Analysis (INAA) with Ge(Li) detectors. The spectra were analysed with the help of an off-line computer programme. Twenty five elements are observed to be present in the ore. The elements of major interest are Fe, Al and Ca with 51.5%, 3.6% and 2.2% concentrations, respectively.  相似文献   

6.
Concentrations of Al, Br, Ca, Ce, Co, Cr, Eu, Fe, Hf, La, Lu, Mg, Mn, Na, Rb, Sc, Sm, Sr, Tb, Th, Ti, V, Yb, Zn, and Zr have been measured in Tigris and Euphrates river water, using neutron activation analysis in combination with preconcentration technique. River water samples were preconcentrated by evaporation at 70°C under atmospheric pressure. The samples with standard reference materials were irradiated with a neutron flux of 2.3·1013 n·cm–2·s–1.  相似文献   

7.
Due to the interaction with components present in natural waters, radionuclides may be present in different physico-chemical forms, varying in size, charge and density. The distribution pattern will influence the transport, mobility and biological uptake of the radionuclides. Size fractionation based on hollow fiber is useful for the determination of the size distribution pattern of radionuclides in natural waters. Furthermore, a continuous mixing and separation system has been developed for the investigation of the association of radionuclides with naturally occurring colloids. Results based on radionuclides in waste water from the Forsmark nuclear power plant, Sweden, will illustrate the potential usefulness of the technique.  相似文献   

8.
Forest Swiss soils from 39 locations sampled ad three depths each were extracted with a buffered solution of pH 4.65 containing EDTA. Nearly 30 elements were determined by instrumental neutron activation analysis in these extracts. The results obtained are discussed in terms of efficiency of the extractant, precision and accuracy. Summariszed results are presented for the quantities fractions of the elements extracted.  相似文献   

9.
We measured 37 elements in six USGS geological camples and one NBS biological orchard leaf (OL) sample, using sequential INAA and radiochemical group separation coupled with high resolution, high efficiency Ge(Li), and a Ge(Li) with anticoincidence shields. The elemental concentrations in these samples vary over three orders of magnitude. Our results agree very well with the reported values. The rare earth values in PCC-1 are 2–4 times lower than the reported values. Precise REE patterns are defined in USGS samples, which are characteristic of the total rock types. The REE pattern in OL is identical to the mineral apatite. In addition to the possibility that OL may be contaminated by local soil, it is also possible that the uptake of REE trace elements by plants from soil is perhaps dominated by accessory mineral such as apatite, or plants take up the REE from bulk soil in a preferential manner as a smooth function of the REE ionic radii.  相似文献   

10.
Summary A radiochemical neutron activation analysis technique for the determination of 51 elements in high purity aluminium via medium- and long-lived indicator radionuclides has been developed. It is based on a separation procedure involving the removal of 24Na, produced via the reaction 27Al(n,), on a hydrated antimony pentoxide column and further separation of the radionuclide mixture into 11 groups on two Dowex 1X8 columns and one Dowex 50X8 column from HCl/HF and HCl media as well as the extraction of copper with APDTC in chloroform. The indicator radionuclides for the significant impurities thorium and uranium, 233Pa and 239Np, were separated with satisfactory selectivity in one fraction. For 43 elements, the limits of detection are <10 ng/g, for thorium and uranium, they are 50 pg/g. The method was applied to the analysis of different high purity aluminium samples. For a number of elements, the results of this technique are compared with those of other techniques.
Radiochemische Multielement-Neutronenaktivierungsanalyse von hochreinem Aluminium

Dedicated to Prof. Dr. W. Fresenius on the occasion of his 75th birthday  相似文献   

11.
Twenty-four elements in six food spices were estimated by non-destructive instrumental neutron activation analysis. The problems in determining Cu were discussed.  相似文献   

12.
In Nigeria, various parts of various species of native plants have long been used for dental hygiene, with reportedly considerable effectiveness. These materials are known as “chewing sticks”. This study was an effort to ascertain whether any unusual trace element concentrations might be present in Nigerian chewing sticks. Results are presented for 17 elements (Na, Mg, Al, Cl, K, Ca, Sc, V, Mn, Fe, Co, Zn, Br, Cs, La, Sm, Au) detected and measured in 12 species of such plants, via instrumental thermal-neutron activation analysis.  相似文献   

13.
A critical evaluation of different comparator methods is given. The method based on experimentally-determined and convertible comparison factors (k) is considered to be the most suitable for general use. An alternative method is proposed, introducing generalized k0 factors which are independent of irradiation and measuring conditions. This approach combines the simplicity of the absolute methods with nearly the same accuracy attained by the relative ones. It is suggested that k0 factors be compiled in all cases when using single-comparator methods, to allow a continuous re-evaluation.  相似文献   

14.
Instrumental neutron activation analysis was applied to multielement trace analysis of high purity aluminium samples. In order to reduce the production of24Na from the matrix, samples were activated by thermal neutron flux of high cadmium ratio. Detection limits of various impurity elements were evaluated. So called “five nine” class standard aluminium samples were analyzed and concentrations of various impurity elements were determined. The analytical results obtained on zone refined aluminium samples showed that zone refining is effective against many elements, such as Na, Cr, Fe, Co, Cu, Ga, As, Br, Ba, La, Ce, Sm, Yb, Lu, Hf, W, Th and U, but not very effective against the element Sc.  相似文献   

15.
Rock samples from seven different locations in northwestern Nigeria were analyzed by reactor instrumental neutron activation analysis and Ge(Li) gamma-ray spectrometry. Concentration values were obtained for 18 elements (As, Ce, Co, Cr, Cs, Eu, Fe, Hf, La, Lu, Sc, Sm, Sr, Ta, Tb, Th, U, Yb). The geochemical implications of the results are discussed.  相似文献   

16.
Instrumental neutron activation analysis (INAA) has been applied for the simultaneous determination of up to 33 elements including major, minor and trace elements in the environmental reference materials soil and coal fly ash from China. The procedure involves both short and long irradiations followed by the measurement of the gamma spectra with a Ge(Li) detector. The analytical results are presented and discussed.  相似文献   

17.
In radiochemical neutron activation analysis, standards may be measured directly or subjected to the same radiochemical processing as the sample. Some considerations in regard to processing are examined, and the advantages and disadvantages of this approach discussed. It is concluded that processing of standards is often inadvisable and can lead to errors, particularly if used as a substitute for radiochemical yield determinations.  相似文献   

18.
Errors in preparing standards, especially multielemental standards, are extremely important if accurate results are desired from neutron activation analysis (NAA). It is often convenient to prepare standards for NAA from single or multi-element solutions which are then deposited onto (or into) a suitable matrix, such as filter paper or quartz vials. There are many potential sources of error in preparing single-element standards including: impurities and non-stoichiometric composition of the element or compound used to prepare the standard solutions; evaporative losses of solvent; inaccuracy of calibration, and imprecision of the pipettes used; moisture content of elements or compounds used; contamination from reagents, equipment, laboratory environment, or final matrix of the standard; instability of standard solutions (i.e., to losses via precipitation or adsorption), and losses of volatile elements during dissolution and/or irradiation. Additional sources of error in preparing multielement standards includes: instability of mixed, multielement solutions, and cross-contamination of one element by the addition of a second element. Procedures previously used by the author at NIST to prepare multielement standards with concentrations accurate to about one percent are described. Additional techniques needed to prepare multielement standards with accuracies better than 1 percent will be discussed.  相似文献   

19.
According to calculations of NIX and others, the formation of superheavy elements might occur in heavy-ion reaction systems such as the one under investigation in the present work i.e.,238U+63,65Cu at 9.6 MeV/nucleon. Since previous experiments have indicated that upper limits to the production cross-section for superheavy elements are extremely low, we have carried out two rather long irradiations of 27 hrs and 42 hrs, respectively, at the University of Manchester LINAC. The first run has already been reported on in the literature. In the case of the second run, after chemical separation into HgS, CdS, and La(OH)3 fractions, the samples were assayed simultaneously and continuously over a period of 6 months for alpha-and spontaneous-fission activity, using Si surface-barrier detector. Each sample was at the same time mounted on mice, for the purpose of scanning for fission tracks at a later date. No indications from the data have so far been found that superheavy elements were produced.  相似文献   

20.
Several instrumental neutron activation analysis techniques (parametric, comparative, and ko-standardization) are evaluated using three reference materials. Each technique is applied to National Institute of Standards and Technology standard reference materials, SRM 1577a (Bovine Liver) and SRM 2704 (Buffalo River Sediment), and the United States Geological Survey standard BHVO-1 (Hawaiian Basalt Rock). Identical (but not optimum) irradiation, decay, and counting schemes are employed with each technique to provide a basis for comparison and to determine sensitivities in a routine irradiation scheme. Fifty-one elements are used in this comparison; however, several elements are not detected in the reference materials due to rigid analytical conditions (e.g., insufficient length of irradiation or activity for radioisotope of interest decaying below the lower limit of detection before counting interval). Most elements are normally distributed around certified or consensus values with a standard deviation of 10%. For some elements, discrepancies are observed and discussed. The accuracy, precision, and sensitivity of each technique are discussed by comparing the analytical results to consensus values for the Hawaiian Basalt Rock to demonstrate the diversity of multielement applications.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号