首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A high-performance liquid chromatographic (HPLC) method is described for the determination of duloxetine hydrochloride in capsules. The method was based on pre-column derivatization with 4-chloro-7-nitrobenzo-2-oxa-1,3-diazole using the fluorimetric detection technique. Duloxetine hydrochloride was analyzed by HPLC using an Inertsil C18 column (5 μm, 150 × 4.6 mm) and mobile phase consisted of methanol and water (65:35, v/v). The fluorescence detector was adjusted at excitation and emission wavelengths of 461 and 521 nm, respectively. The linearity of the method was in the range of 10-600 ng/mL. Limits of detection and quantification were 0.51 and 1.53 ng/mL, respectively. The proposed method was successfully applied for determination of duloxetine hydrochloride in its pharmaceutical preparation. The results were in good agreement with those obtained using a reference method.  相似文献   

2.
A rapid and sensitive reversed-phase high-performance liquid chromatographic method (RP-HPLC) with ultraviolet detection has been developed for the determination of moclobemide and its metabolites, p-chloro-N-(-2-morpholinoethyl)benzamide N'-oxide (Ro 12-5637) and p-chloro-N-[2-(3-oxomorpholino)ethyl]-benzamide (Ro 12-8095), in human plasma. The assay was performed after single liquid-liquid extraction with dichloromethane at alkaline pH using phenacetin as the internal standard. Chromatographic separation was performed on a C(18) column using a mixture of acetonitrile and water (25:75, v/v), adjusted to pH 2.7 with ortho-phosphoric acid, as mobile phase. Spectrophotometric detection was performed at 239 nm. The method has been validated for accuracy, precision, selectivity, linearity, recovery and stability. The quantification limit for moclobemide and Ro 12-8095 was 10 ng/mL, and for Ro 12-5637 was 30 ng/mL. Linearity of the method was confirmed for the range 20-2500 ng/mL for moclobemide (r = 0.9998), 20-1750 ng/mL for Ro 12-8095 (r = 0.9996) and 30-350 ng/mL for Ro 12-5637 (r = 0.9991). Moreover, within-day and between-day precisions and accuracies of the method were established. The described method was successfully applied in pharmacokinetic studies of parent drug and its two metabolites after a single oral administration of 150 mg of moclobemide to 20 healthy volunteers.  相似文献   

3.
王晓春  陶静  李铁纯 《分析测试学报》2016,35(11):1440-1444
建立了加速溶剂萃取/高效液相色谱-三重四极杆串联质谱(ASE/HPLC-MS/MS)批量检测农田土壤中六溴环十二烷(HBCDs)和四溴双酚A(TBBPA)残留的分析方法。土壤样品经加速溶剂萃取,Sep-pak C18固相萃取柱净化后,在多反应监测(MRM)负离子电喷雾模式下进行HPLC-MS/MS分析。色谱柱为X Bridge C18反相柱(150 mm×2.1 mm×3.5μm),流动相为梯度变化的甲醇和水溶液。在最佳实验条件下,六溴环十二烷和四溴双酚A在0.50~200.0μg/L范围内线性关系良好(r≥0.998),方法检出限(S/N≥3)为1.80~10.0 ng/kg。在1.0~40.0μg/kg添加水平内,平均加标回收率为73.8%~106.9%,相对标准偏差(RSD)为5.8%~11.2%。采用该方法分析了我国某区域内表层土壤样品的HBCDs和TBBPA,得到理想的分析效果。  相似文献   

4.
The objective of this study was to optimize a method to investigate the occurrence and to quantify the full isomeric composition of vitamin E (α-, β-, γ- and δ-tocopherols and tocotrienols) in 6 vegetables (raw and cooked), 3 herbs/spices, raw and cooked eggs, vegetable oils (canola, olive and soybean), flaxseed and sorghum (flour and seeds) and soy (flour) by HPLC with fluorescence detection. Different conditions of extraction and analysis were tested. The optimized method consisted of direct extraction with solvent (hexane:ethyl acetate, 85:15, v/v). For analysis normal phase column was used with mobile phase consisting of hexane:isopropanol:acetic acid (98.9:0.6:0.5) with isocratic elution and fluorescence detection. Excellent separation of all isomers was obtained along with adequate quantification in the foods analyzed. Recovery rates of standards ranged from 91.3 to 99.4%. The linearity range for each isomer varied from 2.5 to 137.5 ng/mL (R2 greater than 0.995 in all cases). Detection limits ranged from 21.0 to 48.0 ng/mL for tocopherols and from 56.0 to 67.0 ng/mL for tocotrienols, while quantification limits ranged from 105.0 to 240.0 ng/mL for tocopherols and from 280.0 to 335.0 ng/mL for tocotrienols. The optimized method was considered simple, fast and reliable, and also preserved vitamin E isomers when compared to validated methods involving saponification.  相似文献   

5.
This paper describes validated high-performance column liquid chromatographic (HPLC) and high-performance thin-layer chromatographic (HPTLC) methods for simultaneous estimation of acetylsalicylic acid (ASA) and clopidogrel bisulfate (CLP) in pure powder and formulations. The HPLC separation was achieved on a Nucleosil C8 column (150 mm length x 4.6 mm id, 5 microm particle size) using acetonitrile-phosphate buffer, pH 3.0 (55 + 45, v/v) mobile phase at a flow rate of 1.0 mL/min at ambient temperature. The HPTLC separation was achieved on an aluminum-backed layer of silica gel 60F254 using ethyl acetate-methanol-toluene-glacial acetic acid (5.0 + 1.0 + 4.0 + 0.1, v/v/v/v) mobile phase. Quantitation was achieved with UV detection at 235 nm over the concentration range 4-24 microg/mL for both drugs, with mean recoveries of 99.98 +/- 0.28 and 100.16 +/- 0.66% for ASA and CLP, respectively, using the HPLC method. Quantitation was achieved with UV detection at 235 nm over the concentration range of 400-1400 ng/spot for both drugs, with mean recoveries of 99.93 +/- 0.55 and 100.21 +/- 0.83% for ASA and CLP, respectively, using the HPTLC method. These methods are simple, precise, and sensitive, and they are applicable for the simultaneous determination of ASA and CLP in pure powder and formulations.  相似文献   

6.
A highly sensitive and selective liquid chromatography/tandem mass spectrometric (LC/MS/MS) method was developed to quantify the experimental anticancer agent EO9 and its metabolite EO5a in biological matrices. A 200-microL aliquot of human/dog plasma was spiked with a mixture of deuterated internal standards EO9-d3 and EO5a-d4 and extracted with 1.25 mL of ethyl acetate. Dried extracts were reconstituted in 0.1 M ammonium acetate/methanol (7:3, v/v) and 20-microL volumes were injected onto the LC system. Separation was achieved on a 150 x 2.1 mm C18 column using an alkaline eluent (1 mM ammonium hydroxide/methanol (gradient system)). The detection was performed by a Finnigan TSQ Quantum Ultra equipped with an electrospray ionization source operated in positive mode and enhanced mass resolution capability. It demonstrated improved sensitivity with a factor 10-20 for EO9 and EO5a over a 3-decades dynamic range, with acceptable accuracy and precision, when compared with the previously described assay for EO9 and EO5a, developed by our group, using an API 2000. The assay quantifies a range from 0.5 to 500 ng/mL for EO9 and EO5a using 200-microL human plasma and dog samples. The described mass resolution method was successfully applied for the evaluation of the pharmacokinetic profile of EO9 and its metabolite EO5a in human and dog plasma.  相似文献   

7.
A rapid and sensitive liquid chromatography/tandem mass spectrometry (LC/MS/MS) method has been developed and validated for simultaneous quantification of docetaxel and ketoconazole in rat plasma with paclitaxel as internal standard (IS). The analytes were extracted from rat plasma by using a liquid-liquid extraction technique with ethyl acetate and the LC separation was performed on a Cosmosil-C(18) analytical column (150 mm x 2.0 mm i.d., Nacalai Tesque Inc., Japan). The extracted samples were analyzed with LC/MS/MS, operating in selected reaction monitoring (SRM) mode. The SRM transitions of precursor ions to product ions were 830.3-->549.1 (m/z) for docetaxel, 531.2-->489.3 (m/z) for ketoconazole, and 876.7-->307.9 (m/z) for the IS. The calibration curves were linear over the range of 2-500 ng/mL for docetaxel and 50-20 000 ng/mL for ketoconazole, with coefficients of correlation above 0.999. The limits of quantification for docetaxel and ketoconazole were both 2 ng/mL. The limit of detection for each analyte was 1 ng/mL. The intra- and inter-day precision (CV) of analysis were within 7%, and the accuracy ranged from 95 to 110%. The overall recoveries for docetaxel and ketoconazole were about 89.0% and 91.1%, respectively. The total analysis time was only 9.0 min. This quantitation method was successfully applied to the simultaneous determination of docetaxel and ketoconazole in rat plasma and some potential interaction was found in the current coadministration pharmacokinetic study. This established method was also utilized in the in vitro and in vivo drug-drug interaction study of docetaxel and ketoconazole (to be published).  相似文献   

8.
The present work displays capillary liquid chromatographic column switching methodology tailored for determination of benzo[a]pyrene tetrol isomers in biological matrices using on-line fluorescence and micro-electrospray ionization mass spectrometric detection. A well-established off-line crude solid phase extraction procedure was used in order to make the method compatible with several biological matrices. The solid phase extraction eluates were evaporated to dryness, redissolved in 1.0 ml methanol:water (10:90, v/v), loaded onto a 0.32 mm I.D. x 40 mm 5 microm Kromasil C(18) pre-column for analyte enrichment and back-flushed elution onto a 0.30 mm I.D. x 150 mm 3.5 microm Kromasil C(18) analytical column. The samples were loaded with a flow rate of 50 microl min(-1) and the tetrols were separated at a flow rate of 4 microl min(-1) with an acetonitrile:10 mM ammonium acetate gradient from 10 to 90%. A sample loading flow rate up to 50 microl min(-1) was allowed. The fluorescence excitation and emission were set to 342 and 385 nm, respectively, while mass spectrometric detection of the benzo[a]pyrene tetrols was obtained by monitoring their [M - H](-) molecular ions at m/z 319. The method was validated over the concentration range 0.1-50 ng ml(-1) benzo[a]pyrene tetrols in a cell culture medium with 100 microl injection volume, fluorescence detection and the first eluting tetrol isomer as model compound, resulting in a correlation coefficient of 0.993. The within-assay (n= 6) and between-assay (n= 6) precisions were determined to 2.6-8.6% and 3.8-9.6%, respectively, and the recoveries were determined to 97.9-102.4% within the investigated concentration range. The mass limit of detection (by fluorescence) was 3 pg for all the tetrol isomers, corresponding to a concentration limit of detection of 30 pg ml(-1) cell culture medium. The corresponding mass spectrometric mass limits of detection were 4-10 pg, corresponding to concentration limits of detection of 40-100 pg ml(-1) cell culture medium.  相似文献   

9.
Huperzine A is a potent, reversible acetylcholinesterase inhibitor. In the present work, a rapid and sensitive LC-MS-MS method for the determination of huperzine A in human plasma using codeine phosphate as internal standard has been developed and validated. The analyte and internal standard were extracted from plasma using ethyl acetate, chromatographed on a C(18) column (5 microm, 150 x 4.6 mm i.d.) with a mobile phase consisting of 1% formic acid-methanol (40:60, v/v), and detected using a tandem mass spectrometer with a TurboIonSpray ionization interface. The run time was only 2 min. Good linearity was achieved in the range 0.126 -25.2 ng/mL and the limit of detection in plasma was 0.064 ng/mL. The average recovery for huperzine A was 83.4% from plasma. The analytical sensitivity and accuracy of this assay is adequate for characterization of huperzine A in human plasma.  相似文献   

10.
A new analytical method for the determination of piperine and its isomers in egg yolk and albumen is described here. All four isomers were separated by HPLC and detected using UV, DAD and electrochemical detection. The absolute detection limit (UV detection, S/ N=3) of a standard solution of piperine was 370 pg piperine. The correlation coefficients for the linear calibration graphs (concentration range: c=100 ng-10 micro g piperine isomer/mL) are generally better than 0.996. The piperine isomers were characterized and identified by spectroscopy (MS, (1)H-NMR, FT-IR). The method was successfully applied to the determination of piperine deposits in eggs (egg yolk and albumen) after feeding hens with piperine-spiked feed. The detection limit for piperine (24.8(+/-0.2) ng/g egg yolk and 37.9(+/-4.9) ng/g albumen) and the recoveries (70.3(+/-7.7)% (egg yolk) and 75.7(+/-1.9)% (albumen)) of piperine were determined.  相似文献   

11.
A selective, sensitive and fully automated column-switching LC system using direct injection of human plasma followed by mass spectrometry (MS) detection was developed and validated to determine the concentrations of 4-demethoxy-3'-deamino-3'-aziridinyl-4'-methylsulphonyldaunorubicin++ + (PNU-159548) and its 13-hydroxy metabolite (PNU-169884). A 50-microl human plasma sample was directly introduced into a C4-alkyl-diol silica clean-up column separating analytes from proteins and polar endogenous compounds using water and methanol as the mobile phase. The fraction containing PNU-159548 and its metabolite was back-flushed and transferred to the analytical column. The compounds were separated using a Zorbax SB C8 column (150x4.6 mm, 5 microm) under gradient conditions with the mobile phase containing acetonitrile and 2 mM ammonium formate, pH 3.5. MS detection was by atmospheric pressure ionisation with multiple reaction monitoring in positive ion mode. Linearity was demonstrated over the calibration range of 0.051-10.291 ng/ml for PNU-159548 and 0.104-10.434 ng/ml for PNU-169884. The assay was validated with respect to accuracy, precision and analyte stability. On the basis of the validation data, the developed analytical method was found to be suitable for use in Phase I clinical studies.  相似文献   

12.
A selective and sensitive method for the determination of piritramide in human plasma is described. A 1-ml aliquot of plasma was extracted with 10 ml of hexane-isoamyl alcohol (99.5:0.5, v/v) (extraction efficiency 86%) after addition of 50 microliters of 2 M ammonia and 20 microliters of aqueous strychnine solution (100 ng per 10 microliters) as internal standard. Gas chromatography was performed with J&W DB-1, 30 m x 0.53 mm I.D. separation column, film thickness 1.5 microns, using an nitrogen-phosphorus-sensitive detector. The assay was linear in the concentration range 3.75-2250 ng/ml (r = 0.999), with a lower limit of detection of 1-2 ng/ml. The precision was determined using spiked plasma samples (10 and 50 ng/ml), with coefficients of variation of 3.5 and 3.1% (intra-day; n = 5) and 4.6 and 4.1% (inter-day; n = 4). In the range 3.75-150 ng/ml, the accuracy of the assay was 3.36%. The method was used for the determination of piritramide plasma concentrations in patients receiving intra- or post-operative analgesia.  相似文献   

13.
建立了同时测定地表水中8种双酚类物质(BPs)的超高效液相色谱-串联质谱(UPLC-MS/MS)分析方法.方法 基于QuEChERS处理技术,选用乙酸乙酯为提取剂,从基质效应(ME)和萃取回收率(RE)两方面对过程效率(PE)进行优化,确定了50 mg N-丙基乙二胺(PSA)和50 mg石墨化炭黑(GCB)混合吸附剂...  相似文献   

14.
S M Wu  Y H Ho  H L Wu  S H Chen  H S Ko 《Electrophoresis》2001,22(13):2717-2722
In this study, low concentrations of histamine2-receptor (H2-)antagonists were effected across a water plug, with separation taking place in a binary buffer comprising ethylene glycol and NaH2PO4 (pH 5.0), and detection at 214 nm. Liquid-liquid extraction with ethyl acetate- isopropanol is shown to provide extracts that are sufficiently clean. The calibration curves were linear over a concentration range of 0.1-2.00 microg/mL cimetidine, 0.2-5.0 microg/mL ranitidine-HCl, 0.3-5.0 microg/mL nizatidine, and 0.1-3.0 microg/mL famotidine. Mean recoveries were > 82%, while the intra- and interday relative standard deviations (RSDs) and relative errors (REs) were all < 13%. The method is sensitive with a detection limit of 3 ng/mL cimetidine, 30 ng/mL ranitidine HCl, 50 ng/mL nizatidine and 10 ng/mL famotidine (S/N = 3, electric-driven injection 90 s). This newly developed capillary electrophoresis (CE) method was applied for the determination of analytes extracted from plasma taken from a volunteer dosing a cimetidine, ranitidine, and nizatidine tablet simultaneously. These three H2-antagonists can be detected in real samples by this method, excluding the low dosing of famotidine tablet.  相似文献   

15.
A highly sensitive high-performance liquid chromatographic quantification method with fluorescence detection was developed and validated for the determination of doxazosin in human plasma. The developed method employed one-step extraction of doxazosin from plasma matrix with ethyl acetate using propranolol as an internal standard. Chromatographic separation was obtained within 8.0 min using a reverse-phase Capcell-Pak C(18) column (150 x 4.6 mm i.d., 5 microm) and the mobile phase consisted of methanol-water containing 10 mM perchloric acid and 1.8 mM sodium heptane sulfonic acid (50:50, v/v) and was set at a flow rate of 1.5 mL/min. The calibration curve constructed was linear in the range of 0.3-50.0 ng/mL. The proposed method achieved a lower limit of quantification of 0.3 ng/mL, better than the reported HPLC methods. Average recoveries of doxazosin and the internal standard from human plasma matrix were 87.0 and 85.9%, respectively. The present method was validated by evaluating the precision and accuracy for inter- and intraday variation in the concentration range 0.3-50 ng/mL. The precision values expressed as relative standard deviations in the inter- and intraday validation were 1.17-6.29 and 0.84-5.94%, respectively. This method was successfully applied to the bioequivalence study of two doxazosin controlled release tablets in healthy, male human subjects.  相似文献   

16.
硼-姜黄素络合物的高效液相色谱研究及应用   总被引:2,自引:0,他引:2  
本文研究了在非水体系中硼与质子化的姜黄素形成的络合物以无水甲醇为溶剂,在C18色谱柱上用甲醇-水(80:20 V/V)作流动相(1.00mL/min)分离并检测.硼的校正曲线线性范围为 0.4~3.2μg/25mL,硼的校测限为 0.08ng.此法用于复合硼肥的分析,结果令人满意.  相似文献   

17.
(S)-2-[Benzyl(phenyl)amino]ethyl 5-(5,5-dimethyl-2-oxo-1,3,2-dioxaphosphorinan-2-yl)-1,4-dihydro-2, 6-dimethyl-4-(3-nitrophenyl)-3-pyridinecarboxylate ((S)-NZ-105) and R isomer were synthesized through the fractional crystallization of (S)-2-Methoxy-2-phenylethyl 5-(5,5-dimethyl-2-oxo-1,3,2-dioxaphosphorinan-2-yl)-1,4-dihydro-2, 6-dimethyl-4-(3-nitrophenyl)-3-pyridinecarboxylate. Calcium antagonism activity was found to reside in the S isomer from single crystal X-ray diffraction analysis.  相似文献   

18.
An analytical method that enables direct and sensitive determination of endogenous melatonin (MLT) in human saliva was developed by means of column-switching semi-microcolumn liquid chromatography (i.d.: 1-2 mm)/mass spectrometry (LC/MS). The system allows direct injection analysis of a 400-microL aliquot of saliva with minimal sample pretreatment (internal standard (IS) addition and vortex mixing) and a relatively short run-time (10 min). The system consists of three columns to attain large volume injection and on-line analyte enrichment. A pre-column packed with a silica-based mixed-functional C8 (4.0 mm i.d. x 20 mm) was used for on-line sample cleanup. MLT and an IS, the d7 isomer of MLT (d7-MLT), were heart-cut by valve switching and enriched at the top of the intermediate trapping column packed with a silica-based C18 (4.0 mm i.d. x 10 mm). Subsequently, the analytes were backflushed into a semi-micro C18 silica column (2.0 mm i.d. x 150 mm) for the final separation. MLT and IS were ascertained by positive electrospray ionization and selected ion monitoring (SIM). MLT was monitored based on its fragment ion at m/z 174.1 by in-source collision-induced dissociation (CID). The validation of this method revealed a detection limit of 2.5 pg mL(-1) at a signal-to-noise (S/N) ratio of 5. The linearity of the method was established in the ranges 5-250 and 100-2500 pg mL(-1) with a coefficient of determination of greater than 0.998. Accuracies, evaluated at five levels in the range 5-1000 pg mL(-1), were between 81 and 108% with a relative standard deviation (RSD) ranging from 1.3-20%. The method was successfully applied for the endogenous saliva MLT monitoring of two healthy subjects.  相似文献   

19.
We developed and validated an accurate and sensitive LC–MS/MS method for the simultaneous quantitation of ginsenoside Rg3 and Rh2 epimers (R‐Rg3, S‐Rg3, R‐Rh2, and S‐Rh2) in rat plasma. Analytes were extracted from 0.1 mL aliquots of rat plasma by liquid–liquid extraction, using 2 mL of ethyl acetate. In this assay, dioscin (500 ng/mL) was used as an internal standard. Chromatographic separation was conducted using an Acclaim RSLC C18 column (150 × 2.1 mm, 2.2 μm) at 40°C, with a gradient mobile phase consisting of 0.1% formic acid in distilled water and in acetonitrile, a flow rate of 0.35 mL/min, and a total run time of 20 min. Detection and quantification were performed using a mass spectrometer in selected reaction‐monitoring mode with negative electrospray ionization at m/z 783.4 → 161.1 for R‐Rg3 and S‐Rg3, m/z 621.3 → 161.1 for R‐Rh2 and S‐Rh2, and m/z 867.2 → 761.5 for the internal standard. For R‐Rg3 and S‐Rg3, the lower limit of quantification was 5 ng/mL, with a linear range up to 500 ng/mL; for R‐Rh2 and S‐Rh2, the lower limit of quantification was 150 ng/mL, with a linear range up to 6000 ng/mL. The coefficient of variation for assay precision was less than 10.5%, with an accuracy of 86.4–112%. No relevant cross‐talk or matrix effect was observed. The method was successfully applied to a pharmacokinetic study after oral administration of 400 mg/kg and 2000 mg/kg of BST204, a fermented ginseng extract, to rats. We found that the S epimers exhibited significantly higher plasma concentrations and area under curve values for both Rg3 and Rh2. This is the first report on the separation and simultaneous quantification of R‐Rg3, S‐Rg3, R‐Rh2, and S‐Rh2 in rat plasma by LC‐MS/MS. The method should be useful in the clinical use of ginseng or its derivatives.  相似文献   

20.
Belaz KR  Cass QB  Oliveira RV 《Talanta》2008,76(1):146-153
The development and validation of a fully automated achiral-chiral high performance liquid chromatography (HPLC) method for the simultaneous determination of albendazole metabolites: enantiomers of albendazole sulphoxide (ABZ-SO), albendazole sulphone (ABZ-SO(2)) and albendazole 2-aminosulphone (ABZ-SO(2)NH(2)) in bovine plasma are described. This method involves an octyl restricted access media bovine serum albumin column (C(8)-RAM-BSA) (50 mm x 4.6 mm I.D.) for sample clean-up, followed by enantioselective analysis on a column containing an amylose tris(3,5-dimethylphenylcarbamate) stationary phase (150 mm x 4.6 mm I.D.). The chromatographic separations of all target compounds were performed at 30 degrees C using a mobile phase composed of phosphate buffer (10 mmol L(-1); pH 7.5):acetonitrile (60:40, v/v), flow rate of 0.5 mL min(-1) and fluorescence detection at 290 nm and 320 nm, excitation and emission, respectively. The influence of different organic modifiers and chiral selector of the stationary phase on enantioseparation of ABZ-SO was investigated. The method developed was fully validated. The calibration curves were linear in the concentration range of 40.00-1280 ng mL(-1) for each albendazole sulphoxide enantiomer, 10.0-320 ng mL(-1) for albendazole sulphone and 20.0-320 ng mL(-1) for albendazole 2-aminosulphone. The inter- and intra-day precision ranged from 0.760% to 7.79% relative standard deviation (R.S.D.), and the accuracy ranged 101% from 114% of the nominal values while the transfer efficiency was in the range of 84.4-103%. The method showed good linearity, precision, accuracy, sensitivity and selectivity allowing it to be appropriate for further pharmacokinetics and metabolism studies of albendazole.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号