首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 367 毫秒
1.
刘华良  李放  杨润  王联红  马永建 《色谱》2009,27(1):50-53
建立了超高效液相色谱-串联质谱(UPLC-MS/MS)测定化妆品中常见的6种抗生素(美满霉素、土霉素、四环素、金霉素、多西环素、氯霉素)及甲硝唑的方法,并用于实际样品的分析。样品经甲醇-0.1 mol/L甲酸溶液(体积比为1∶1)超声提取后,以甲醇(含1%甲酸)-水(含1%甲酸)为流动相,经UPLC梯度洗脱分离后以多反应监测(MRM)模式质谱测定。方法的检出限为3~20 ng/g,回收率为87%~101%,工作曲线的线性相关系数大于0.995,线性范围为2~1000 μg/L (达3个数量级)。对11份市售化妆品进行分析检测,其中2份检出氯霉素,质量分数分别为0.37%和0.19%;1份检出甲硝唑,质量分数为1.02%;美满霉素、土霉素、四环素、金霉素、多西环素未检出。  相似文献   

2.
毛细管电泳用于水产品中五种抗生素的同时测定   总被引:29,自引:0,他引:29  
用毛细管电泳-紫外检测法同时测定水产品中的四环素(TC)、金霉素(CTC)、土霉素(OTC)、多西环素(DC)及氯霉素(CAP)的含量.研究了缓冲体系的酸度、浓度、添加剂、分离电压、进样时间以及温度等条件对分离的影响,得到了电泳的最优条件.在278nm波长处,分离电压为22kV,20mmol/L磷酸氢二钠-10mmol/L柠檬酸(pH值2.8,含0.25mmol/L Na2EDTA和体积分数为4.0%的吐温-80)运行缓冲液下,上述5种组份在25min内得到完全分离.5种抗生素的质量浓度和电泳峰面积在2.5~300.0mg/L和10.0~300.0mg/L范围内呈现良好的线性,TC、CTC、OTC、DC和CAP的相关系数(r)分别为0.9996、0.9992、0.9993、0.9934、0.9987,检测下限为0.5~1.5μg/mL。该方法灵敏度高,重现性好,操作简便,并已成功用于水产品鲫鱼中的5种抗生素残留的检测。  相似文献   

3.
陆军  庞燕军  李彦博  王超 《色谱》2012,30(6):641-646
建立了一种高效液相色谱-二极管阵列检测器(HPLC-DAD)同时测定祛痘产品中6种抗生素(盐酸美满霉素、土霉素、盐酸四环素、盐酸金霉素、盐酸多西环素和氯霉素)及甲硝唑的分析方法。样品用甲醇提取,采用Agilent ZORBAX SB-C18色谱柱(250 mm×4.6 mm, 5 μm)分离;以甲醇、乙腈和0.002 mol/L草酸为流动相进行梯度洗脱,流速0.8 mL/min;柱温20 ℃,检测波长268 nm,进样量10 μL,外标法定量。结果表明,6种抗生素及甲硝唑在1~30 mg/L范围内呈良好的线性关系,相关系数(r)均不低于0.9970;方法检出限为1.1~1.2 μg/g;高、中、低(5、10、20 mg/L) 3个添加水平下的回收率为91.9%~107.7%,相对标准偏差(RSD)为0.13%~1.74%。应用该方法对祛痘产品进行检验,15%的样品中检出甲硝唑。该方法具有灵敏、准确、快速、分离效果好的优点,适用于祛痘产品中6种抗生素及甲硝唑的检测。  相似文献   

4.
以介孔硅磁性氧化石墨烯为载体,四环素、土霉素、金霉素、强力霉素共同作为模板,N-[3-(三甲氧基甲硅烷基)丙基]乙二胺(KH-792)和苯胺甲基三乙氧基硅烷(KH-42)为功能单体,通过溶胶-凝胶法制备了四环素类抗生素多模板分子印迹聚合物。以扫描电镜(SEM)、红外光谱(IR)及振动样品磁强计(VSM)对聚合物进行表征。将所制备的多模板分子印迹聚合物作为吸附剂应用于磁性固相萃取,结合高效液相色谱法,建立了水样中四环素、土霉素、金霉素及强力霉素测定的新方法。该方法对4种四环素类抗生素的线性范围为5~50 μg/L,检出限为0.67~0.95 μg/L,定量下限为2.13~3.50 μg/L。实际样品的加标回收率为82.7%~103%,相对标准偏差(RSD)为1.0%~8.8%。方法可用于实际环境水样中4种四环素类抗生素的同时检测。  相似文献   

5.
规模化养殖场废水中抗生素种类及残留特征研究   总被引:1,自引:0,他引:1  
2010年调查了海南省6家规模化养猪场抗生素使用品种及来源,并采集养殖废水样品,用高效液相色谱紫外检测器检测了样品中4种四环素(四环素、土霉素、金霉素和强力霉素)和8种磺胺类药物(磺胺嘧啶、磺胺甲噻唑、磺胺噻唑、磺胺二甲基嘧啶、磺胺氯哒嗪、磺胺邻二甲氧嘧啶、磺胺间二甲氧嘧啶和磺胺喹恶啉)的残留浓度水平。结果显示,6家养殖场废水中土霉素、四环素和磺胺嘧啶的检出率及检出浓度较高,其中土霉素检出率为100%,最高浓度为71.75μg/L;四环素检出率为63%,最高检出浓度为24.83μg/L;磺胺嘧啶检出率为83%,最高检出浓度为17.69μg/L。4种四环素类检出总量变化范围为18.25~99.64μg/L,8种磺胺类检出总量变化范围为3.45~24.49μg/L;从养殖规模上看,小规模养殖场抗生素类检出品种较多,检出浓度也较高。  相似文献   

6.
建立了混合型固相萃取及季铵化纤维素负载的纳米金涂层毛细管电泳法快速检测血浆中土霉素和多西环素的方法。采用季铵化纤维素负载的纳米金复合材料(QC-Au NPs)对毛细管内壁进行动态涂层,以抑制管壁对分析物的吸附,并对缓冲液p H值进行优化。结果表明,该涂层能改善峰形和分离度,提高分离效率,其中土霉素的柱效提高了17.9倍。在涂层毛细管中,土霉素和多西环素的吸附被抑制,并在4 min内出峰。在10~200μg/m L范围内,土霉素和多西环素的峰面积与浓度的线性关系良好,相关系数(r)分别为0.997 6和0.995 2。血浆中土霉素和多西环素的加标回收率为88%~107%,相对标准偏差(RSD)为1.4%~7.7%。该方法快速、简便,准确度和精密度高,适用于血浆中土霉素和多西环素的快速检测。  相似文献   

7.
蜂蜜中残留抗生素的填充毛细管液相色谱法检测   总被引:6,自引:0,他引:6  
黄宏南  陈天豹  陈儒明  饶平凡 《色谱》1999,17(6):588-589
采用新型毛细管高效液相色谱法和自行填充的毛细管色谱柱,以四环素、土霉素和金霉素为标准物,对蜂蜜中残留的四环素类抗生素进行了定量分析。方法具有操作简单、灵敏度高、定量准确的优点。在10μg/L至0.4mg/L的质量浓度范围内,土霉素、四环素和金霉素的线性相关系数分别为rOTC=0.99695,rTC=0.99778和rCTC=0.98836。毛细管高效液相色谱法可用于抗生素类物质的高灵敏度测定。  相似文献   

8.
张琰图  章竹君  孙永华 《化学学报》2006,64(24):2461-2466
基于四环素类抗生素药物中的四环素(TC)、土霉素(OTC)、金霉素(CTC)和多西环素(DC)能够强烈增敏通过恒电流电解方法在线电生BrO和鲁米诺之间产生的化学发光, 提出了一种高效液相色谱(HPLC)化学发光(CL)法检测4种四环素类抗生素药物的新方法. 以Nucleosil RP-C18 (250 mm×4.6 mm, i.d., 5 μm, pore size, 100 Å)为色谱柱, 0.05 mol• L-1磷酸二氢钾(pH 2.5)-乙腈(30∶70, VV)为流动相, 流速1.2 mL/min, 柱温25 ℃, 同时分离检测四种抗生素的总时间为11 min. 研究并优化了流动相、电生试剂化学发光检测的条件. 四种抗生素的检出限为0.002~0.008 μg•mL-1 (3σ), 对0.01 μg•mL-1的四种抗生素测定的相对标准偏差为2.0%~3.6% (n=11). 该方法已成功应用于牛奶中残留四环素类抗生素含量的分析.  相似文献   

9.
以土霉素为模板分子制备了分子印迹固相微萃取涂层,建立了选择性萃取、高效液相色谱法同时测定牛奶和水样中四环素、盐酸土霉素和金霉素三种四环素类抗生素的分析方法。将0.1mmol盐酸土霉素在功能单体和交联剂的作用下制备分子印迹预聚合液,将经多巴胺处理后的不锈钢丝前端1~2cm置入其中,制备分子印迹固相微萃取涂层。3mL牛奶和水样经涂层萃取50min、解析5min,乙腈-10mmol/L磷酸盐缓冲液(PBS,pH=3)作为流动相,二极管阵列检测器(DAD)定量分析。实验结果表明,分子印迹涂层对四环素类目标物的特异性选择明显优于非印迹涂层。三种目标抗生素在100~1 000μg/L(牛奶)和10~1 000μg/L(水样)浓度范围内线性关系良好,相关系数在0.9959以上,四环素、盐酸土霉素和金霉素的检出限(S/N=3)为40~80μg/L(牛奶)和5~10μg/L(水样);加标水平为500μg/L时,回收率范围97.8%~109.0%,相对标准偏差(n=7)分别为5.3%~8.2%(牛奶),3.7%~6.4%(水样)。该方法前处理简单、绿色环保、选择性好、精密度好、回收率高,可用于牛奶和水样中上述三种四环素的实际检测。  相似文献   

10.
建立了肉类中土霉素(OTC)、四环素(TC)、金霉素(CTC)残留量的高效液相色谱荧光检测方法.样品经5%HClO4除蛋白后,离心过滤.采用Waters XTerra RP18(5 μm,4.6×150 mm)色谱柱,以V(甲醇):V(CaCl2缓冲液)=30:70(pH 6.6)为流动相,等度洗脱,流速0.8 mL/min,柱温25℃.经CaCl2缓冲液衍生化,在激发波长(Zx)350 nm和发射波长(Zm)520nm处检测土霉素、四环素和金霉素的残留量.结果表明,在此条件下,测得上述3种抗生素在0.09~4.64μg/mL范围内线性良好,土霉素的最小检测限为1.48 ng/mL,四环素为1.20ng/mL,金霉素为2.32 ng/mL,方法的精密度为0.69%~1.23%,加样回收率为64.63%~90.89%.实验证明本方法可用于检测肉类中土霉素、四环素和金霉素的残留量.  相似文献   

11.
毛细管电泳安培法检测酚类化合物   总被引:7,自引:0,他引:7  
使用自行设计组装的毛细管电泳柱端安培检测系统 ,对四个酚类化合物进行了分离检测。研究了工作电极、缓冲液及其 p H值、检测电压和分离电压对分离检测的影响。在优化条件下 ,4个酚在 5× 1 0 -6~ 5× 1 0 -4 mol/L范围内峰高与浓度成良好的线性关系 ,检测下限为 8.5× 1 0 -7mol/L  相似文献   

12.
反相高效液相法测定四环素类抗生素   总被引:15,自引:0,他引:15  
王蕾  张孝松  徐智秀  邵学广 《色谱》2002,20(1):49-51
 利用高效液相法 ,在C18柱上以甲醇 乙腈 0 0 1mol/L草酸溶液 (pH 2 0 ) (体积比为 11∶2 2∶6 7)为流动相 ,采用 2 6 7nm紫外光进行检测 ,在 2 2min内将 7种四环素类抗生素全部洗脱并达到基线分离。探讨了流动相的pH值、草酸的浓度、流动相中有机相的比例以及检测波长等因素对分离度和灵敏度的影响。采用标准加入法定量 ,对两种实际样品进行了分析。结果表明 :该方法操作简单、灵敏度高、定量准确。  相似文献   

13.
A simple, rapid, and specific ion-pair liquid chromatographic method for routine determination of the marker residue of oxytetracycline (OTC), namely OTC and 4-epi-oxytetracycline (4-epiOTC), in edible animal tissues (muscle, liver, kidney, and fat) has been developed. Minced tissue samples were acidified at pH 2.7 with 2 mol L(-1) sulfuric acid and extracted with acetonitrile. The extracts were purified by treatment with ammonium sulfate solution and concentrated into 0.1 mol L(-1) phosphoric acid. Baseline separation was carried out isocratically on a Nucleosil 100-5 C(18), 5-microm column using an acetonitrile-0.01 mol L(-1) disodium hydrogen phosphate (20:80, v/v) mobile phase that contained both positively (tetrabutylammonium) and negatively (octanesulfonate) charged pairing ions and EDTA, and was adjusted to pH 3.8. Detection was by UV at 370 nm. The method was fully validated according to Commission Decision 2002/657/EC. Overall recoveries were better than 82.6% and overall relative standard deviation was better than 6% for all the tissues examined. The good analytical characteristics of the method allowed limits of quantification as low as 30 ng g(-1) for muscle and fat and 50 ng g(-1) for liver and kidney, for both OTC and 4-epiOTC, to be realized. The method was successfully used to determine the OTC marker residue in tissues of two sheep intramuscularly administered a commercial OTC formulation.  相似文献   

14.
High-performance ion chromatography (HPIC) is first successfully used to analyze tetracycline antibiotics (TCs) in this work. The TCs are well separated on a solvent compatible polymeric cation-exchange column within 12 min. Isocratic elution with acetonitrile-hydrochloride is very advantageous for routine analysis. HPIC may be seen as a specific variant of the more common high-performance liquid chromatography (HPLC) for water-soluble and polar pharmaceuticals with low hydrophobicity. The detection limits (signal-to-noise ratio=3:1) of oxytetracycline (OTC), tetracycline (TC), chlortetracycline (CTC), doxycycline (DC) are 10, 10, 20 and 20 microg l(-1), respectively. Samples are prepared by vortex mixing with an ethylenediaminetetraacetic acid disodium salt (Na2EDTA)-McIlvaine buffer (pH 4.0) solution and the mixture filtrates through a molecular weight cut-off filter. The method has been successfully applied to monitor the OTC removal rate through every reactor in the process of OTC manufacturing wastewater treatment by bio-chemical technology. It is also applicable to determine the TCs residues in milk and milk powder with satisfying results.  相似文献   

15.
建立了微乳电动毛细管色谱分离3种氯丙醇的方法。以十二烷基硫酸钠(SDS)作为表面活性剂,系统考察了pH值、缓冲溶液类型和浓度、SDS浓度、助表面活性剂浓度、油相浓度、温度和运行电压对3-氯-1,2-丙二醇(3-MCPD),1,3-二氯-2-丙醇(1,3-DCP),2,3-二氯-1-丙醇(2,3-DCP)分离的影响。结果表明,最佳微乳缓冲液为1%(V/V)正庚烷,100 mmol/L SDS,10%(V/V)正丁醇和8 mmol/L磷酸二氢钠-硼砂溶液(pH 8.50),检测波长为192 nm,温度20℃,分离电压为15 kV。3种氯丙醇的线性范围为2.0×10-6~3.2×10-5 mol/L,相关系数大于0.996,检出限(S/N=3)为0.95~1.9μmol/L。酱油样品经乙醚液液萃取,萃取平均回收率为93.2%~103.0%,相对标准偏差小于6.5%。本方法应用于实际样品和加标后样品中三氯丙醇的检测,结果满意。  相似文献   

16.
选用1-乙烯基-3-乙基咪唑四氟硼酸盐([VElm]BF4,一种离子液体)作为功能单体,以Co2+为介导离子,结合1-丁基-3-甲基咪唑四氟硼酸盐([BMIM]BF4)/二甲基亚砜(DMSO)二元致孔体系制备了绿原酸印迹整体柱。经过对制备参数的考察,确定最佳比例为绿原酸:Co2+:[VElm]BF4:EDMA(乙二醇二甲基丙烯酸酯)(摩尔比)=1:1:5:20,[BMIM]BF4:DMSO=3:1(V/V),最大印迹因子达2.10。通过优化色谱条件,最终在乙腈:20 mmol/L乙酸钠缓冲液(pH 4.2)=70:30(V/V)时实现了绿原酸及其类似物的完全分离。由此可见,以离子液体为功能单体及致孔剂,在金属介导策略下制备的分子印迹聚合物可实现绿原酸的特异性识别及分离。  相似文献   

17.
Capillary zone electrophoresis was employed for the determination of histamine using end-column amperometric detection with a carbon fiber microelectrode, at a constant potential. The optimum conditions of separation and detection were 10 mmol/L phosphate buffer, pH 5.6 for the buffer solution, 15 kV for the separation voltage, and 1.35 V (versus SCE) for the detection potential. The linear range was from 6.3 x 10(-7) to 1.5 x 1(-5) mol/L with the regression coefficient of 0.9997, and the detection limit was 4.0 x 10(-7) mol/L (S/N = 3). The proposed method was successfully applied to the direct determination of histamine in the beer samples without any sample clean-up procedures.  相似文献   

18.
固相萃取-亲水作用色谱法测定废水中四环素类抗生素   总被引:1,自引:0,他引:1  
建立了固相萃取(SPE)-亲水作用色谱法(HILIC)测定废水中金霉素(CTC)、强力霉素(DC)、四环素(TC)和土霉素(OTC) 4种四环素类抗生素(TCs)残留的新方法.水样经Oasis HLB固相萃取柱净化富集后, 采用以氨基色谱柱及高极性有机溶剂-水相缓冲溶液为流动相的亲水作用色谱法(HILIC)进行分析. 对流动相中缓冲溶液的类型和pH值、离子强度、 有机溶剂的浓度以及流速进行了优化, 确定了以V(乙腈)∶V(6.7 mmol/L柠檬酸铵缓冲溶液, pH 4.0)=85∶ 15混合液为流动相的最佳条件.本方法具有良好的线性关系(r> 0.999)和重现性(峰面积RSD<1.0%), 最低检出限(S/N=3)为12~30 μg/L, 4种四环素类药物添加水平在0.5~10 μg/L范围内的标准加入回收率为 90.6%~106.5%; 相对标准偏差为 2.5%~6.2%.本方法简便、准确、流动相离子强度低,适合于与质谱联用,用于屠宰场污水及医院污水等实际样品检测,结果满意.  相似文献   

19.
A capillary zone electrophoresis method with UV detection was developed for the simultaneous detection and quantification of three tetracyclines in chicken meat samples: tetracycline (TC), oxytetracycline (OTC) and doxycycline (DOC). The separation conditions were: a running buffer containing 30 mM sodium phosphate, 2 mM EDTA disodium salt and 2.5% 2-propanol, pH 12.0, a 5 s hydrodynamic injection and a 14 kV separation voltage. Two different clean-up methodologies were employed: solid-phase extraction with C18 cartridges and ion exchange with Amberlite XAD7 resin. Analytes were detected at 360 nm in less than 12 min. LODs ranged from 61 μg kg−1 for OTC to 68 μg kg−1 for DOC with C18 cartridges, and 81 μg kg−1 for DOC to 89 μg kg−1 for TC with Amberlite XAD7 resin. The recoveries for TC, OTC and DOC obtained by both methods were between 85 and 95%, and the peak area repeatability for all of the samples was below 5% in all cases. Twenty-four samples of commercial chicken drumsticks were examined with both clean-up methodologies. In nine cases (37.5%) TC was detected, in a range from 197.8 to 2564.3 μg kg−1, and in seven cases (29.2%) OTC was detected in a range from 83.0 to 2049.3 μg kg−1. DOC was not detected in any of the tested samples. This method would be useful for the routine monitoring of TCs residues in poultry muscle.  相似文献   

20.
胡娟  闻京伟 《应用化学》2001,18(12):1009-0
喹诺酮类药物属于人工合成抗生素 ,至今已开发或正在开发的约 5 0多种 ,成为抗感染药物中最活跃的研究领域之一 ,是一类有巨大潜力的新型抗菌药 .喹诺酮类药物的测定 ,大多采用高效液相色谱法 [1~ 3 ] .但高效液相色谱仪的价格昂贵 ,测定对样品的处理要求较高 ,应用受到限制 .示波分析法具有仪器简单、操作简便、选择性高等优点 ,用此法测定吡哌酸、诺氟沙星含量已有报道 [4~ 6] .本文进一步研究了依诺沙星 (ENX)、环丙沙星(CPLX)、氧氟沙星 (OFLX)、氟罗沙星 (FLRX)和司帕沙星 (SPLX)等 5种喹诺酮类药物的示波测定条件及方法 .S…  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号