共查询到20条相似文献,搜索用时 15 毫秒
1.
Summary Interferences in the flameless determination of lead using the HGA 72 were studied for HCl, HNO3, H2SO4, H3PO4, HClO4, HF and for a number of cations. In certain instances interferents in just 1000-fold concentration over lead are shown to cause deviations in the lead signal. Many of the interferences are matrix-dependent themselves and can be reduced by matrix variations. Optimization of the thermal pretreatment can be used effectively to reduce random error and/or systematic errors. The thermal stability of lead compounds in the graphite furnace was sufficient for charring procedures up to 900° C for 20 s.
Statistische Untersuchungen über Störungen bei der flammenlosen Atomabsorptionsspektralphotometrie
Zusammenfassung Interferenzen, die bei der flammenlosen Bestimmung von Blei in der HGA 72 auftreten, wurden bei HCl, HNO3, H2SO4, H3PO4, HClO4, HF und einigen Kationen studiert. In gewissen Fällen reicht ein nur 1000 facher Überschuß des Störions, um Abweichungen vom Signal des Bleistandards hervorzurufen. Da das Auftreten von Interferenzen auch oft matrixabhängig ist, können Matrixvariationen zur Unterdrückung von Interferenzen eingesetzt werden. Die Optimierung des Temperaturprogrammes wird erfolgreich zur Beeinflussung des Zufallsfehlers und/ oder systematischer Fehler herangezogen. In der Graphitrohrküvette reichte die Stabilität der Bleiverbindung aus, um beim Veraschungsschritt die Temperatur bis auf 900° C (20 s) zu steigern.
Part I: Z. Anal. Chem. [13].Part II: Z. Anal. Chem. [14]. 相似文献
2.
Summary Interferences in the flameless determination of cadmium using the HGA 72 were studied for HCl, HNO3, H2SO4, HClO4 and HF and found to be depending on different thermal pretreatment. The interferences of cations were much smaller than for anions. The results are discussed with respect to thermal stability as well as atomization rate of the compositions under investigation. Special emphasis is put upon the presence of interactions between interferents, which in some cases can be used to eliminate interferences.
Statistische Untersuchungen über Störungen bei der flammenlosen AtomabsorptionsspektralphotometrieII. Cadmium
Zusammenfassung Interferenzen, die bei der flammenlosen Bestimmung von Cadmium in der HGA 72 auftreten, wurden bei HCl, HNO3, H2SO4, H3PO4, HClO4 und HF studiert; die AbhÄngigkeit ihres Auftretens von der thermischen Vorbehandlung wird gezeigt. Interferenzen von Kationen sind kleiner. Die Ergebnisse werden im Hinblick auf die thermische StabilitÄt und die Atomisierungsgeschwindigkeit der Proben diskutiert. Besonders betont wird die Gegenwart von Wechselwirkungen zwischen Störungen, die manchmal auch benützt werden können, um Interferenzen auszuschalten.
Part I: Z. Anal. Chem. [10] 相似文献
3.
Summary In the first part different methods for studying interferences of the time dependent signal in flameless AAS are presented with emphasis on factorial designs in experimentation as opposed to the one-factor-at-a-time approach.An example of the statistical computations necessary for interpretation of a multifactor experiment is worked out and discussed in detail with special consideration of the explanation of first-order interactions.The influence of instrumentation upon determinations in the graphite furnace is dealt with in the second part: The temperature in the graphite furnace was measured with a pyrometer, a thermocouple and a Hg-thermometer. The results obtained with the pyrometer were in good agreement with the values given by the manufacturer. The stability of the AAS system was checked and found to be sufficient for the investigation of interferences.
Statistische Untersuchungen über Störungen bei der flammenlosen AtomabsorptionsspektralphotometrieI. Methoden und Apparaturen
Zusammenfassung Im ersten Abschnitt werden die verschiedenen Möglichkeiten zur Untersuchung von Störungen des zeitabhängigen Signals bei der flammenlosen AAS aufgezeigt, wobei besondere Bedeutung den faktoriellen Versuchsplänen im Gegensatz zu einparametrigen Untersuchungen beigemessen wird.Ein Beispiel der statistischen Auswertung zur Interpretation eines Experiments mit mehreren Faktoren wird gebracht, und dabei besonderes Gewicht auf die Erklärung von Wechselwirkungen zwischen zwei Faktoren gelegt.Im zweiten Abschnitt werden die apparativen Einflüsse auf Messungen in der Graphitrohrküvette behandelt. Dazu wurde die Temperatur im Graphitrohr mit einem Pyrometer, einem Thermoelement und einem Quecksilberthermometer gemessen. Die Temperaturen, die mit der pyrometrischen Methode gefunden wurden, stimmen gut mit den vom Hersteller angegebenen Werten überein. Die Stabilität des AAS-Gerätes wurde überprüft: sie reicht für die Durchführung von Interferenzstudien aus.相似文献
4.
5.
Summary The interfering effect of thirty six metal salts on chromium absorbance in the air-acetylene flame has been studied. The interference does not depend on the boiling point of the added foreign metals or particle size as previously assumed but is postulated to result from the formation of mixed oxides or bimetallic species or from suppression of ionized gaseous chromium pressure. The effect of the alkali sulphates as releasing agents in the determination of chromium has been tested and results show that they can be used to eliminate both suppressive and enhancing interferents.
Störungseinflüsse verschiedener Metalle bei der Chrombestimmung durch AAS
Zusammenfassung Die Störungsmöglichkeiten von 36 verschiedenen Metallsalzen bei der AAS-Bestimmung von Chrom mit Hilfe der Luft-Acetylen-Flamme wurden systematisch untersucht. Dabei stellte sich heraus, daß der Einfluß dieser Salze nicht — wie früher angenommen — vom Siedepunkt der betreffenden Metalle oder der Teilchengröße abhängt, sondern von der Bildung von Mischoxiden, Bimetallverbindungen oder von der Herabsetzung des Chromdampfdrucks. Weiterhin wurde die Wirkung von Alkalisulfaten als Releasing-Reagentien untersucht und gefunden, daß diese sowohl bei abschwächender als auch verstärkender Wirkung angewendet werden können.相似文献
6.
J. Musil 《Fresenius' Journal of Analytical Chemistry》1974,271(5):352-354
Summary The following substances have been investigated with regard to their interfering effect in the determination of aluminium by atomic absorption spectrophotometry: HCl, H2SO4, HNO3, H3PO4, alkali and alkaline earth metals, Cu, Fe, Zn, Ni, Mn, Co, Mo, Ti, Cr, V, Si. Ternary systems with La have been examined also. Si exerts a strong depressive effect, whereas other elements in certain concentration ranges exhibit positive effects.
Störungen bei der atomabsorptionsspektralphotometrischen Bestimmung von Aluminium
Zusammenfassung Folgende Substanzen wurden hinsichtlich einer möglichen Beeinflussung der Aluminiumbestimmung untersucht: HCl, H2SO4, HNO3, H3PO4, Alkalimetalle, Erdalkalimetalle, Cu, Fe, Zn, Ni, Mn, Co, Mo, Ti, Cr, V, Si. Ternäre Systeme mit La wurden ebenfalls geprüft. Si übt eine stark depressive Wirkung aus, während andere Elemente in bestimmten Konzentrationsbereichen positiv wirken.
Lecture given on the 2nd Czechoslovak Conference on Flame Speotroscopy, Zvíkov, June 5–8, 1973. 相似文献
7.
Summary A study has been made of possible interferences upon the determination of selenium by hydride generation atomic absorption spectrometry (HGAAS), due to the presence of other hydride forming elements such as As, Ge, Bi, Te, Sn and Sb, and to a volatile element such as Hg. The interfering effects of these cations were determined at several concentration levels using sodium borohydride as the reductant and a commercially available semi-automatic system for the generation and the flameless combustion of the hydrides. It has been demonstrated that the determination of selenium by HGAAS is relatively free from interferences with regard to other elements that form volatile hydrides, except for tin and bismuth that strongly interfere.
Einfluß von flüchtige Hydride bildenden Elementen auf die Selenbestimmung als Hydrid durch AAS
Zusammenfassung Bei der AAS-Bestimmung von Selen als Hydrid wurde der Einfluß der hydridbildenden Elemente As, Ge, Bi, Te, Sn, Sb sowie auch des flüchtigen Elements Hg untersucht. Die Untersuchungen wurden bei verschiedenen Konzentrationen mit Natriumborhydrid als Reduktionsmittel durchgeführt. Dabei wurde ein handelsübliches halbautomatisches System zur Erzeugung und flammenlosen Verbrennung der Hydride benutzt. Es zeigte sich, daß die Selenbestimmung bis auf die stark störenden Elemente Sn und Bi relativ frei von Beeinflussungen ist.相似文献
8.
9.
10.
K. -R. Sperling 《Fresenius' Journal of Analytical Chemistry》1977,287(1):23-27
Summary For the determination of cadmium in culture water from toxicological experiments with marine organisms direct flameless atomic absorption spectrophotometry seems to be an appropriate method, because it is less complicated than any combination with an extraction method. Unfortunately, it cannot be applied in the g·l–1-range without modifications, because matrix effects lead to unacceptable variations in the results. It was found that these difficulties can be overcome by the addition of ammonium peroxodisulphate and sulphuric acid. A routine method basing on this effect has been developed.
Bestimmung von Schwermetallen im Meerwasser und in marinen Organismen durch flammenlose Atomabsorptions-Spektralphotometrie. VI. Cadmiumbestimmung in Kulturwässern von toxikologischen Experimenten mit Meeresorganismen
Zusammenfassung Zur Cadmiumbestimmung in Kulturwasser von toxikologischen Versuchen mit marinen Organismen scheint die direkte flammenlose Atomabsorptions-Spektralphotometrie besonders geeignet zu sein, denn sie ist weniger umständlich als jede Kombination mit einer Extraktionsmethode. Ohne Modifikationen kann die Direktbestimmung jedoch im g/l-Bereich nicht eingesetzt werden, denn Matrixeffekte bewirken allzu starke Streuungen der Meßergebnisse. Es wird gezeigt, daß ein Zusatz von Ammoniumperoxodisulfat und Schwefelsäure zur Probenlösung eine deutliche Verbesserung bewirkt. Eine Routinemethode wurde entwickelt, bei der von diesem Effekt Gebrauch gemacht wird.相似文献
11.
12.
13.
K. R. Sperling 《Fresenius' Journal of Analytical Chemistry》1978,292(2):113-119
Summary The appicability of flameless AAS to direct cadmium determinations in seawater samples is limited to a level of about 2g l–1 [22]. Thus, for lower concentrations, a combination with an extraction method has been tested. It has been shown that the extraction can well be carried out with ammonium pyrrolidine dithiocarbamate (APDC). However, several modifications of the well known APDC/MIBK-Method were necessary. The key for the method presented was the choice of an appropriate solvent (CCl4, C2Cl4) for the reagent as well as for its Cd-complex. Then a simple, sensitive and miniaturized method has been developed, which has then been applied to a few natural seawater samples.
Bestimmung von Schwermetallen im Meerwasser und in marinen Organismen durch flammenlose AtomabsorptionsspektralphotometrieVII. Ein einfaches Extraktionsverfahren zur Bestimmung extrem niedriger Cadmiumgehalte in kleinen Seewasserproben
Zusammenfassung Die direkte Bestimmung von Cadmium im Meerwasser durch flammenlose AAS stößt unterhalb einer Konzentration von 2g l–1 auf beträchtliche Schwierigkeiten [22]. Deshalb wurde eine kombinierte Methode erprobt, bei welcher das Metall zunächst extrahiert und dann mittels flammenloser AAS bestimmt wird. Es zeigte sich, daß die Extraktion gut mit Ammoniumpyrrolidindithiocarbamat (APDC) ausgeführt werden kann. Es wurden jedoch erhebliche Abwandlungen der wohlbekannten APDC-MIBK-Extraktionsmethode erforderlich. Erst als es gelang, ein geeignetes Solvens (CCl4, C2Cl4) sowohl für das APDC als auch für seinen Cd-Komplex zu finden, konnte eine einfache, empfindliche und miniaturisierte Bestimmungsmethode entwickelt werden, mit deren Hilfe dann der Cd-Gehalt einiger Meerwasserproben bestimmt wurde.相似文献
14.
R. D. Parker 《Fresenius' Journal of Analytical Chemistry》1978,292(5):362-364
Summary An extraction technique is described for the determination of ppm concentrations of both hydrophobic and hydrophilic methylsiloxane compounds in water, based on a single extraction with a mixed solvent of (11) l-pentanol and methyl isobutyl ketone followed by the determination of the silicone compounds extracted into the mixed solvent by atomic absorption spectroscopy. The method is applicable over the concentration range 0.3–30 ppm Si. Standard deviation in the case of 10 ppm Si is 0.313.
Bestimmung von siliciumorganischen Verbindungen in Wasser mit Hilfe der Atomabsorptions-Spektralphotometrie
Zusammenfassung Zur Bestimmung von ppm-Konzentrationen an hydrophoben und hydrophilen Methylsiloxanverbindungen im Wasser wird ein Extraktionsverfahren beschrieben. Hierbei wird nach einfacher Extraktion mit l-Pentanol/Methylisobutylketon (11) das Silicium im Extrakt mit Hilfe der AAS bestimmt. Der erfaßbare Konzentrationsbereich liegt bei 0,3–30 ppm Si. Die Standardabweichung beträgt bei 10 ppm Si 0,313.相似文献
15.
P. E. Paus 《Fresenius' Journal of Analytical Chemistry》1973,264(2):118-122
Summary Direct determination of trace metals in sea water by flame atomic absorption technique suffers from serious interferences caused by the high salt content. Separation of the metals from the matrix has been effected by chelation and extraction with ammonium pyrrolidine dithiocarbamate and methyl-isobutyl-ketone. Besides a separation preconcentration and increased sensitivity is achieved with this extraction. Organic substances and metal-organic complexes are destroyed with UV-radiation before extraction is carried out. Flameless atomic absorption has been tried using the Heated Graphite Furnace combined with a) a selective volatilization procedure, b) removing of sodium from the samples using hydrated antimon pentoxide (HAP). Both methods were used to remove the interfering substances (mainly sodium salt). All the techniques have been compared by analysing the same sea water samples, some of which were also analysed by other laboratories.
Bestimmung einiger Schwermetalle in Meereswasser durch Atomabsorptions-Spektralphotometrie
Zusammenfassung Die direkte Bestimmung der Spurenmetalle in Meereswasser durch Flammen-Atomabsorption wird durch den hohen Salzgehalt behindert. Die Abtrennung der Metalle von der Matrix wurde durch Komplexierung und Extraktion mit Ammoniumpyrrolidindithiocarbamat und Methylisobutylketon erreicht, wodurch außerdem eine Anreicherung und Steigerung der Empfindlichkeit erzielt wird. Organische Substanzen und metallorganische Komplexe können durch UV-Bestrahlung vor der Extraktion zerstört werden. Die flammenlose Technik mit Hilfe des erhitzten Graphitrohres wurde in Kombination mit a) einer selektiven Verdampfungsmethode und b) der Entfernung des Natriums mit hydratisiertem Antimonpentoxid eingesetzt. Alle Verfahren wurden an Hand der gleichen Wasserproben verglichen. Tests wurden auch von anderen Laboratorien durchgeführt.
This work was made possible by substantial grants from International Atomic Energy Agencies (IAEA) and from the Royal Norwegian Council for Scientific and Industrial Research. 相似文献
16.
17.
Michael Wettern 《Fresenius' Journal of Analytical Chemistry》1978,292(4):278-281
Zusammenfassung Es wird eine nasse HF-HClO4Veraschungsmethode von biologischem Material in offenen PTFE-Reagensgläsern beschrieben. In anschließenden flammenlosen AAS-Messungen mit Hilfe der Deuterium-Untergrundkompensation und des automatischen Probenwechslers AS-1 konnte gezeigt werden, daß Silicium vollständig entfernt worden, kein meßbarer Matrix-Effekt festzustellen war und die Bleikonzentrationsbestimmung durch eine Eichgerade und durch Standard-Addition zu gleichen Werten führte. Die Methode ist mit einem Variations-Koeffizient von 0,45% behaftet.Frau Karin Heuer danke ich für die sorgfältige Mitarbeit, der DFG für die Unterstützung der Arbeit durch das Projekt We 755, 1 (791,7). 相似文献
18.
W. Hoffmeister 《Fresenius' Journal of Analytical Chemistry》1978,290(4):289-291
Summary Beside ionic impurities, DI water contains non-ionic compounds, which mainly consist of the oxyhydrates of the elements Fe, Ti, and Si present as colloids. This paper describes an analytical method for Fe, which is based on a simple enrichment by evaporation and the subsequent determination by flameless AAS. It is demonstrated that DI water systems, which are mainly based on coprecipitation and ion exchange, remove the Fe from the main water only to a small extent. The Fe content in DI water shows significant variations.
Bestimmung von Eisen in hochreinem Wasser durch Atomabsorptionsspektroskopie
Zusammenfassung Neben ionischen Bestandteilen enthält selbst hochreines Wasser auch nicht-ionische Komponenten, hauptsächlich Oxidhydrate der Elemente Ti, Fe und Si, die als Kolloide vorliegen. Die analytische Bestimmung des Eisens durch Eindampfen in einer einfachen Anordnung mit anschließender flammenloser AAS wird beschrieben. Es wird gezeigt, daß DI-Wasseranlagen, die heute zumeist noch nach dem Prinzip der Mitfällung und anschließendem Ionenaustausch arbeiten, nur begrenzt kolloidal vorliegendes Eisen entfernen und daß das Reinstwasser in seinem Fe-Gehalt stärkeren Schwankungen unterworfen ist.相似文献
19.
Osamu Kujirai Takeshi Kobayashi Emiko Sudo 《Fresenius' Journal of Analytical Chemistry》1979,297(5):398-403
Summary A simple and rapid analytical method has been developed for the direct determination of trace quantities of thallium in nickel and cobalt-base heatresisting alloys by graphite furnace atomic absorption spectrometry. Hydrofluoric acid, sulphuric acid, and hydrogen peroxide were used for the dissolution of a wide variety of these alloys. The interferences of matrix elements and acids were eliminated. The absorbance of thallium is constant over a wide range of ashing temperatures. Synthetic standard solutions composed of nickel or cobalt matrix and thallium were used for calibration. The detection limit for thallium by this method is 0.2 ppm in the sample. Mechanisms of the interferences are discussed.
Schnelle Bestimmung von Thalliumspuren in hitzebeständigen Cobalt- und Nickellegierungen durch Atomabsorptions-Spektralphotometrie mit dem Graphitofen
Zusammenfassung Ein Verfahren zur AAS-Bestimmung von Thallium in verschiedenartigen Cobalt- und Nickellegierungen wird beschrieben. Zur Auflösung der Probe werden Flußsäure, Schwefelsäure und Wasserstoffperoxid verwendet. Störungen durch Matrixelemente und durch die Säuren konnten beseitigt werden. Die Thalliumabsorption ist über einen weiten Temperaturbereich bei der Veraschung konstant. Zur Eichung dienen synthetische Lösungen von Cobalt- bzw. Nikkelmatrix und Thallium. Die Nachweisgrenze für Thallium beträgt 0,2 ppm. Die Mechanismen der Störungen werden diskutiert.相似文献
20.
S. A. Popova L. Bezur L. Pólos E. Pungor 《Fresenius' Journal of Analytical Chemistry》1974,270(3):180-183
Summary Gallium can satisfactorily be determined by atomic absorption in organic solvents using air-acetylene or nitrous oxide-acetylene flame. It is recommandable to extract it as chloride complex. By employing MIBK and nitrous oxide-acetylene flame a considerable increase of absorption signal and sensitivity and elimination of the interference effect of a large number of metal ions was achieved.
Bestimmung von Gallium durch Extraktion und Atomabsorptionsmessung
Zusammenfassung Mit Hilfe der Luft/Acetylen- oder N2O/Acetylen-Flamme kann Ga aus organischen Lösungsmitteln mit guten Ergebnissen bestimmt werden. Zu bevorzugen ist die Extraktion als Chloridkomplex, Extraktion mit MIBK und Verwendung der N2O-Acetylen-Flamme. So kann eine wesentliche Zunahme des Absorptionssignals, eine Verbesserung der Empfindlichkeit und Ausschaltung des störenden Einflusses zahlreicher Fremdionen bewirkt werden.相似文献