首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
An automated method for high‐throughput amino acid analysis, using precolumn derivatization high‐performance liquid chromatography/electrospray mass spectrometry (HPLC/ESI‐MS), was developed and evaluated. The precolumn derivatization step was performed in the reaction port of a home‐built auto‐sampler system. Amino acids were derivatized with 3‐aminopyridyl‐N‐hydroxysuccinimidyl carbamate, and a 3 μm Wakosil‐II 3C8‐100HG column (100 × 2.1 mm i.d.) was used for separation. To achieve a 13 min cycle for each sample, the derivatization and separation steps were performed in parallel. The results of the method evaluation, including the linearity, and the intra‐ and inter‐precision, were sufficient to measure physiological amino acids in human plasma samples. The relative standard deviations of typical amino acids in actual human plasma samples were below 10%. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

2.
Anandamide (AEA) is an endocannabinoid present in human plasma that is associated with several physiological functions and disease states. However, low AEA plasma levels pose challenges in terms of analytical characterization. Classical liquid‐based lipid extraction and solid‐phase extraction require complicated procedures and the drying down of relatively large volumes of solvents, making them unsuitable for high‐throughput analysis. Here a high‐throughput salting‐out assisted liquid–liquid extraction (SALLE) method with acetonitrile and mass spectrometry compatible salts for liquid chromatography–tandem mass spectrometry (LC‐MS/MS) analysis of AEA in human plasma has been developed and validated. The seamless interface of SALLE and LC‐MS eliminated the drying‐down step, only 100 μL of plasma is required and minimal volumes of organic solvent are used. Good reproducibility, accuracy and precision were demonstrated during the method validation. The method is linear up to 10 ng/mL with a lower limit of quantitation of 0.1 ng/mL for AEA, the accuracy for AEA was from 93.3 to 96.7% and the precision was <8.57%. This new methodology was successfully applied to analysis of clinical samples from maintenance hemodialysis patients. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

3.
A method using liquid chromatography/tandem mass spectrometry (LC/MS/MS) for the determination of terbinafine in human and minipig plasma has been developed and validated. The method used positive-ion mode for monitoring terbinafine, and used a stable isotope labelled terbinafine as the internal standard. Subsequent to acetonitrile protein precipitation, the supernatant was directly (unfiltered) injected onto the LC column (retention time approximately 4.3 min) for analysis. Interday and intraday accuracy and precision were assessed from the relative recoveries (observed concentration in percent of the nominal value) of spiked samples analyzed on three different days. The lower limit of quantitation (LLOQ) was 0.0679 ng/mL in human and minipig using a plasma sample volume of 0.08 mL. The method was fast, specific, and exhibited ruggedness. Furthermore, the use of turbulent flow chromatography (TurboFlow LC/MS/MS) coupled to mass spectrometry for direct analysis of terbinafine in plasma is discussed. The technique allowed direct introduction of plasma with satisfactory chromatographic peak shape and increased throughput.Copyright 2000 John Wiley & Sons, Ltd.  相似文献   

4.
HR011303 is a novel and highly selective urate transporter 1 (URAT1) inhibitor. In this study, a sensitive liquid chromatography–tandem mass spectrometry (LC–MS/MS) method was developed and validated for quantification of HR011303 in beagle dog plasma. Plasma samples were pretreated with protein‐precipitation extraction by acetonitrile and added with a trifluoromethyl substituted analog of HR011303 as internal standard. The chromatographic separation was performed on a Shiseido C18 column (100 × 4.6 mm, i.d., 5 μm) by mobile phases consisting of 5 mm ammonium–formic acid (100:0.1) and acetonitrile–formic acid (100:0.1) solutions in gradient elution. The MS detection was conducted in electrospray positive ionization with multiple reactions monitoring at m/z 338 → 240 for HR011303 and m/z 328 → 230 for the internal standard using 25 eV argon gas collision induced dissociation. The established LC–MS/MS method showed good selectivity, sensitivity, precision and accuracy. The plasma pharmacokinetics of HR011303 in beagle dogs following both oral and intravenous administration were then successfully evaluated using this LC–MS/MS method.  相似文献   

5.
A candidate reference measurement procedure for total testosterone in human serum involving isotope dilution (ID) coupled with liquid chromatography/tandem mass spectrometry (LC/MS/MS) has been developed and critically evaluated. The endogenous testosterone and its internal standard (testosterone-d 3) were extracted from the serum matrix using a combination of solid-phase extraction and liquid–liquid extraction prior to reversed-phase LC/MS/MS. Accuracy of the measurements was evaluated by a recovery study using testosterone-spiked serum. The recovery of the added testosterone ranged from 100.0 to 100.3%. This method was applied to the determination of testosterone in frozen serum samples from three individual donors (one female and two males) with the testosterone concentrations ranging from 0.3 to 8.5 ng g−1. Repeatability with within-set coefficients of variation (CVs) from 0.1 to 1.0% and intermediate precision with between-set CVs from 0.1 to 0.5% for both female and male serum materials were demonstrated. Excellent linearity was obtained for all linear regression lines. The detection limit at a signal-to-noise ratio of approximately 3 was 2 pg of testosterone in serum. Structural analogs as well as testosterone metabolites were tested and found to not interfere with the measurement of testosterone. This well-characterized LC/MS/MS method for serum testosterone, which demonstrates good accuracy and precision, and low susceptibility to interferences, qualifies as a reference measurement procedure that can be used to provide an accuracy base to which routine methods for testosterone can be compared and that will serve as a standard of higher order for measurement traceability.  相似文献   

6.
In the present work, for the first time, a rapid and sensitive liquid chromatography/positive atmospheric pressure photoionization tandem mass spectrometry (LC/APPI‐MS/MS) method has been developed and validated for the simultaneous quantitation of testosterone, estradiol, ethinyl estradiol, and 11‐ketotestosterone in fathead minnow fish plasma using no more than 10 µL of plasma. Compounds present in plasma were directly derivatized with dansyl chloride and 25 µL of the derivatized mixture was injected into the LC/APPI‐MS/MS system. The gradient chromatographic elution was achieved on an Agilent Zorbax SB‐C18 analytical column (2.1 mm × 50 mm, 1.8 µm particle size) with mobile phases consisting of acetonitrile, water and acetic acid. The flow rate was 0.5 to 0.7 mL/min and the total run time was 11.5 min. The lower limits of quantitation for testosterone, estradiol, ethinyl estradiol, and 11‐ketotestosterone and were 1, 1, 1, and 2.5 ng/mL, respectively. Intra‐batch precision was less than 19.4% and inter‐batch precision was less than 11.7% for all four analytes. Accuracy was within 83.5–115.4% of nominal concentrations. This method is used for quantitation of sex steroid levels in fathead minnow tested in endocrine disruptor screening experiments. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

7.
A high‐throughout bioanalytical method based on salting‐out‐assisted liquid/liquid extraction (SALLE) method with acetonitrile and mass spectrometry‐compatible salts followed by LC‐MS/MS analysis of trimetazidine in rat plasma is presented. It required only 50 μL of plasma and allows the use of minimal volumes of organic solvents. The seamless interface of SALLE and LC‐MS eliminated the drying‐down step and the extract was diluted and injected into an LC‐MS/MS system with a cycle time of 2.5 min/sample. The retention times of trimetazidine and IS were approximately 1.1 and 1.7 min, respectively. Calibration curves were linear over the concentration range of 0.1–100 ng/mL, which can be extended to 500 ng/mL by dilution. The intra‐ and inter‐batch precision, accuracy and the relative standard deviation were all <15%. This method was successfully applied to determine trimetazidine concentrations in rat plasma. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

8.
In the field of isotope ratio mass spectrometry, the introduction of an interface allowing the connection of liquid chromatography (LC) and isotope ratio mass spectrometry (IRMS) has opened a range of new perspectives. The LC interface is based on a chemical oxidation, producing CO2 from organic molecules. While first results were obtained from the analysis of low molecular weight compounds, the application of compound-specific isotope analysis by irm-LC/MS to other molecules, in particular biomolecules, is presented here. The influence of the LC flow rate on the CO2 signal and on the observed delta13C values is demonstrated. The limits of quantification for angiotensin III and for leucine were 100 and 38 pmol, respectively, with a standard deviation of the delta13C values better than 0.4 per thousand. Also, accuracy and precision of delta13C values for elemental analyser-IRMS and flow injection analysis-IRMS (FIA-LC/MS) were compared. For compounds with molecular weights ranging from 131 to 66,390 Da, precision was better than 0.3 per thousand, and accuracy varied from 0.1 to 0.7 per thousand. In a second part of the work, a two-dimensional (2D)-LC method for the separation of 15 underivatised amino acids is demonstrated; the precision of delta13C values for several amino acids by irm-LC/MS was better than 0.3 per thousand at natural abundance. For labelled mixtures, the coefficient of variation was between 1% at 0.07 atom % excess (APE) for threonine and alanine, and around 10% at 0.03 APE for valine and phenylalanine. The application of irm-LC/MS to the determination of the isotopic enrichment of 13C-threonine in an extract of rat colon mucosa demonstrated a precision of 0.5 per thousand, or 0.001 atom %.  相似文献   

9.
In this study, a sensitive liquid chromatography–tandem mass spectrometry (LC–MS/MS) method was developed and validated for the quantification of demethylzeylasteral in rat plasma. Electrospray ionization was operated in the negative ion mode while demethylzeylasteral and oleanolic acid (internal standard) were measured by selected reaction monitoring (demethylzeylasteral: m/z 479.2 → 436.0; oleanolic acid: m/z 454.9 → 407.2). This LC–MS/MS method had good selectivity, sensitivity, accuracy and precision. The pharmacokinetic profiles of demethylzeylasteral were subsequently examined in Wistar rats after oral or intravenous administration.  相似文献   

10.
A sensitive and selective method for the determination of long-acting released octreotide in human plasma has been developed based on liquid chromatography/tandem mass spectrometry (LC/MS/MS). Octreotide and the internal standard, triptorelin, were precipitated from the matrix, washed with dichloromethane and subsequently separated by reversed-phase high-performance liquid chromatography (HPLC) employing a 1% formic acid/methanol gradient system. Detection was by electrospray ionization mass spectrometry in the positive ion mode using multiple-reaction monitoring. The assay was linear in the concentration range 0.0500-50.0 ng/mL with intra- and inter-day precision (as relative standard deviation) of <2.95% and <8.37%, respectively. The limit of detection was 0.0200 ng/mL. The method was applied to a pharmacokinetic study of long-acting released octreotide in healthy volunteers given an intramuscular injection containing 20 mg octreotide.  相似文献   

11.
Apelin peptides are of great interest owing to their involvement in physiological and pathological processes and they have been proposed as novel biomarkers for heart failure. The plasma concentrations of bioactive peptides of 12 (apelin‐12), 13 (apelin‐13) and pyroglutamyl apelin‐13 (apelin‐p13), 17 (apelin‐17) and 36 (apelin‐36) amino acids are reported to range from 20 to 4000 pg/mL in healthy subjects. As standard immunoassays cannot specifically quantify each apelin peptide, we have developed a sensitive and targeted multiplexed liquid chromatography/tandem mass spectrometry (LC/MS/MS) method for each plasma apelin fragment. The approach was based on a cation‐exchange extraction step of apelin forms present in human plasma. Apelin‐12, ‐13, ‐p13, ‐17 and ‐36 were quantified using a triple quadrupole mass spectrometer operating in the multiple reaction monitoring mode. Stable isotope‐labeled internal standards were used for quantification. Following assay validation, apelin peptide stability in plasma was investigated. Ten plasma samples from healthy donors were analyzed both with a standard immunoassay and with our LC/MS/MS method. The immunoassay results for the ten healthy donors showed immunoreactive plasma apelin concentrations ranging from 208 to 466 pg/mL. The lower limits of detection of our LC/MS/MS assay ranged from 10 to 50 pg/mL for apelin‐12, ‐13, ‐p13, ‐17, and ‐36. Surprisingly, none of the five expected circulating forms of apelin was detected. These results question the nature and/or the concentration of circulating apelin peptides as well as the specificity of the immunoassays that have hitherto been used for clinical applications. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

12.
A simple and sensitive liquid chromatography (LC) method was developed for the simultaneous determination of eight quinolones in pig plasma samples. The following two methods of detection were used: ultraviolet (UV) and mass spectrometry with electrospray ionization (ESI/MS). Sample preparation consisted of solid-phase extraction (SPE) on Strata X cartridges prior to the analysis by LC/UV or LC/ESI/MS. The recovery, linearity, limit of detection (LOD) and limit of quantification (LOQ), precision and accuracy of the method were evaluated using spiked pig plasma samples. The suitability of the method for pharmacokinetic studies was evaluated by determining the concentrations of enrofloxacin (ENR) and ciprofloxacin (CIP) also in pig plasma, after administration of 200mg of enrofloxacin per kilogram of fodder during 5 consecutive days.  相似文献   

13.
A rapid analytical method for amines and amino acids was developed, involving derivatization with the novel reagent 3‐aminopyridyl‐N‐hydroxysuccinimidyl carbamate (APDS), followed by reversed‐phase high‐performance liquid chromatography and electrospray ionization tandem mass spectrometry (HPLC/ESI‐MS/MS). More than 100 different analytes with amino groups, including amino acids in biological fluids such as mammalian plasma, could be measured within 10 min. The analytes were easily derivatized with APDS under the mild conditions. Selective reaction monitoring of ESI‐MS/MS in positive mode was carried out to include the transitions of all of the protonated molecular ions of analytes derivatized with APDS to the common fragment at m/z 121, which was derived from the amino pyridyl moiety of the reagent. We evaluated the retention time precision, the quantification limits, the linearity, the intra‐ and inter‐day precisions and the accuracy of 22 typical amino acids found in biological fluids, by analyzing a standard amino acid mixture and rat plasma. The intra‐day relative standard deviations (RSDs) of the retention times of the 22 amino acids and their internal standards were within 0.9% and the inter‐day RSDs were less than 1.1%, except for asparagines, with an RSD of 1.9%. The intra‐day and inter‐day RSDs of amino acid analyses in rat plasma were within 8.0% and 4.5%, respectively. The method, which facilitates the amino acid analysis of more than 100 samples in a day, represents an alternative to traditional amino acid analysis techniques, such as chromatography using postcolumn derivatization by ninhydrin. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

14.
A sensitive liquid chromatography/tandem mass spectrometry (LC/MS/MS) method was developed to determine carbocysteine in human plasma using 2-pyridylacetic acid as the internal standard (IS). The method employed derivatization with 10 M hydrochloric acid/methanol, which significantly improved the ionization efficiency of carbocysteine. After methanol-induced protein precipitation of plasma samples, carbocysteine and the IS were derivatized and subjected to LC/MS/MS analysis using atmospheric pressure chemical ionization. The method has a lower limit of quantitation of 20 ng/mL for a 0.2-mL plasma aliquot. The intra- and inter-day precision (RSD), calculated from quality control (QC) samples, was less than 7%. The accuracy, determined using QC samples, was within +/- 1%. The method offered increased sensitivity, selectivity and speed of analysis over existing methods. The method was utilized to support clinical pharmacokinetic studies of carbocysteine in volunteers following oral administration.  相似文献   

15.
A rapid, simple and sensitive liquid chromatography–tandem mass spectrometry (LC/MS/MS) was developed for the determination of an antiepileptic drug, lacosamide, in rat plasma. The method involves the addition of acetonitrile and internal standard solution to plasma samples, followed by centrifugation. An aliquot of the supernatant was diluted with water and directly injected into the LC/MS/MS system. The separations were performed on column packed with octadecylsilica (5 µm, 2.0 × 50 mm) with 0.1% formic acid and acetonitrile as mobile phase, and the detection was performed on tandem mass spectrometry by the multiple‐reaction monitoring via an electrospray ionization source. The standard curve was linear over the concentration range from 0.3 to 1000 ng/mL. The lower limit of quantification was 0.3 ng/mL using 50 μL of rat plasma sample. The intra‐ and inter‐assay precision and accuracy were found to be less than 11.7 and 8.8%, respectively. The developed analytical method was successfully applied to the pharmacokinetic study of lacosamide in rats. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

16.
A simple plasma extraction method coupled with liquid chromatography–tandem mass spectrometry (LC/MS/MS) detection was developed and validated for the analysis of endogenous mevalonic acid (MVA), a biomarker indicative of the rate of cholesterol biosynthesis, in human plasma samples. The analyte was extracted from the plasma matrix using a straightforward liquid–liquid sample preparation procedure. The extract supernatants were evaporated, reconstituted in aqueous solvent and injected into the LC/MS/MS system without further processing. The chromatographic separation was achieved on a reverse‐phase high‐performance liquid chromatography column. The accuracy and precision of the method was determined over the concentration range 0.25–25 ng/mL MVA from human plasma extracts in three validation batch runs. Inter‐assay precision (%CV) and accuracy (%RE) of the quality control samples were ≤7.00% (at lower limit quality control) and ≤6.10%, respectively. The sensitivity and throughput of this assay was significantly improved relative to previously published methods, resulting in smaller sample requirements and shorter analysis time. Assay results from a clinical study following the oral administration of an exploratory statin demonstrate that this procedure could potentially be used in the investigation of therapies associated with hypercholesterolemia. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

17.
This paper presents the multiresidue determination of the series of quinolones regulated by the European Union (marbofloxacin, ciprofloxacin, danofloxacin, enrofloxacin, sarafloxacin, difloxacin, oxolinic acid and flumequine) in bovine and porcine plasma using capillary electrophoresis and liquid chromatography with ultraviolet detection (CE‐UV, LC‐UV), liquid chromatography–mass spectrometry and –tandem mass spectrometry (LC‐MS, LC‐MS/MS) methods. These procedures involve a sample preparation by solid‐phase extraction for clean‐up and preconcentration of the analytes before their injection into the separation system. All methods give satisfactory results in terms of linearity, precision, accuracy and limits of quantification. The suitability of the methods to determine quinolones was evaluated by determining the concentration of enrofloxacin and ciprofloxacin in real samples from pig plasma and cow plasma. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

18.
A sensitive and specific liquid chromatography/tandem mass spectrometry (LC/MS/MS) method was developed for the investigation of the pharmacokinetics of ketotifen and its major metabolite, ketotifen N-glucuronide, in human plasma. The plasma samples were treated by liquid-liquid extraction and analyzed using LC/MS/MS with an electrospray ionization interface. Diphenhydramine was used as the internal standard. The method had a lower limit of quantitation of 10 pg/mL for ketotifen, which offered increased sensitivity, selectivity and speed of analysis, compared with existing methods. The intra- and inter-day precision were measured to be below 8.2% and accuracy between -2.4% and 3.4% for all QC samples. Incubation of the plasma samples with beta-glucuronidase allowed the quantitation of ketotifen N-glucuronide. This quantitation method was successfully applied to a pharmacokinetic study of ketotifen and its major metabolite after oral administration of 2 mg ketotifen fumarate to 16 healthy volunteers.  相似文献   

19.
Seventy-six molecules of biological interest for the diagnosis of inherited disorders of amino acids (AA) metabolism have previously been demonstrated to be detectable in electrospray ionization tandem mass spectrometry (ESI-MS/MS) positive mode without derivatization. Reversed-phase liquid chromatography (RPLC) separation on different C18 columns using various perfluorinated carboxylic acids as ion-pairing agents has been found suitable for coupling with MS/MS, and for the separation of AA. A new procedure was optimized in order to replace the usual ion-exchange chromatographic, post-column ninhydrin derivatization, time-consuming routine method. This procedure allowed an adequate separation of all the molecules from other known interfering compounds, and a throughput of two samples per hour. Quantification limits for each molecule were found to be compatible with their measurement in plasma and urine. We validated the qualitative part of the method by analyzing plasma and urine samples from patients affected with several inherited disorders of AA metabolism. We validated the quantification of 16 AA using their stable isotopes as internal standard. The calibration curves were linear over the range 0-3 mM. The quantitative results obtained with the new method on 105 plasma and 99 urine samples were in good agreement with those obtained by the established routine method. Spiking experiments and precision results were also satisfactory.  相似文献   

20.
A simple, rapid and sensitive method for quantification of atomoxetine by liquid chromatography–tandem mass spectrometry (LC‐MS/MS) was developed. This assay represents the first LC‐MS/MS quantification method for atomoxetine utilizing electrospray ionization. Deuterated atomoxetine (d3‐atomoxetine) was adopted as the internal standard. Direct protein precipitation was utilized for sample preparation. This method was validated for both human plasma and in vitro cellular samples. The lower limit of quantification was 3 ng/mL and 10 nm for human plasma and cellular samples, respectively. The calibration curves were linear within the ranges of 3–900 ng/mL and 10 nm to 10 µm for human plasma and cellular samples, respectively (r2 > 0.999). The intra‐ and inter‐day assay accuracy and precision were evaluated using quality control samples at three different concentrations in both human plasma and cellular lysate. Sample run stability, assay selectivity, matrix effect and recovery were also successfully demonstrated. The present assay is superior to previously published LC‐MS and LC‐MS/MS methods in terms of sensitivity or the simplicity of sample preparation. This assay is applicable to the analysis of atomoxetine in both human plasma and in vitro cellular samples. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号