首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A new cytological tool, based on the microCoulter particle counter (microCPC) principle, aimed at diagnostic applications for cell counting and separation in haematology, oncology or toxicology is described. The device measures the spectral impedance of individual cells or particles and allows screening rates over 100 samples s(-1) on a single-cell basis. This analyzer is intended to drive a sorting actuator producing a subsequent cell separation. Size reduction and integration of functions are essential in achieving precise measurements and high throughput. 3D finite element simulations are presented to compare various electrode geometries and their influence on cell parameters estimation. The device is based on a glass-polyimide microfluidic chip with integrated channels and electrodes microfabricated at the length scale of the particles to be investigated (1-20 microm). A laminar liquid flow carries the suspended particles through the measurement area. Each particle's impedance signal is recorded by a differential pair of microelectrodes using the cell surrounding media as a reference. The micromachined chip and processing electronic circuit allow simultaneous impedance measurements at multiple frequencies, ranging from 100 kHz to 15 MHz. In this paper, we describe the microfabrication and characterisation of an on-chip flow-cytometer as the first building block of a complete cell-sorting device. We then discuss the signal conditioning technique and finally impedance measurements of cells and particles of different sizes and types to demonstrate the differentiation of subpopulations in a mixed sample.  相似文献   

2.
Salomon S  Leichlé T  Nicu L 《Electrophoresis》2011,32(12):1508-1514
In this article, we propose a novel dielectrophoretic continuous flow sorter using planar micro electrodes coupled to a channel constriction. This design enables a high particle sorting efficiency at low voltages while relying on a simple fabrication and integration process. We have numerically simulated the AC electrokinetic effects and the fluid behavior to predict particle trajectories. Simulation results are in accordance with experimental data: 10 and 5 μm polystyrene beads were continuously sorted with <2% errors at flow speeds of 100 μm/s. We were also able to change the particle buffer while sorting beads. Finally, to demonstrate the interest of our device for cell sorting, we also sorted dead and living yeast cells according to their different dielectric properties. Living cell concentration was enriched by a factor of 4 versus dead cell concentration after passing the sorting device.  相似文献   

3.
Moon HS  Kwon K  Kim SI  Han H  Sohn J  Lee S  Jung HI 《Lab on a chip》2011,11(6):1118-1125
Circulating tumor cells (CTCs) are highly correlated with the invasive behavior of cancer, so their isolations and quantifications are important for biomedical applications such as cancer prognosis and measuring the responses to drug treatments. In this paper, we present the development of a microfluidic device for the separation of CTCs from blood cells based on the physical properties of cells. For use as a CTC model, we successfully separated human breast cancer cells (MCF-7) from a spiked blood cell sample by combining multi-orifice flow fractionation (MOFF) and dielectrophoretic (DEP) cell separation technique. Hydrodynamic separation takes advantage of the massive and high-throughput filtration of blood cells as it can accommodate a very high flow rate. DEP separation plays a role in precise post-processing to enhance the efficiency of the separation. The serial combination of these two different sorting techniques enabled high-speed continuous flow-through separation without labeling. We observed up to a 162-fold increase in MCF-7 cells at a 126 μL min(-1) flow rate. Red and white blood cells were efficiently removed with separation efficiencies of 99.24% and 94.23% respectively. Therefore, we suggest that our system could be used for separation and detection of CTCs from blood cells for biomedical applications.  相似文献   

4.
Continuous sorting of magnetic cells via on-chip free-flow magnetophoresis   总被引:1,自引:0,他引:1  
Pamme N  Wilhelm C 《Lab on a chip》2006,6(8):974-980
The ability to separate living cells is an essential aspect of cell research. Magnetic cell separation methods are among some of the most efficient methods for bulk cell separation. With the development of microfluidic platforms within the biotechnology sector, the design of miniaturised magnetic cell sorters is desirable. Here, we report the continuous sorting of cells loaded with magnetic nanoparticles in a microfluidic magnetic separation device. Cells were passed through a microfluidic chamber and were deflected from the direction of flow by means of a magnetic field. Two types of cells were studied, mouse macrophages and human ovarian cancer cells (HeLa cells). The deflection was dependent on the magnetic moment and size of the cells as well as on the applied flow rate. The experimentally observed deflection matched well with calculations. Furthermore, the separation of magnetic and non-magnetic cells was demonstrated using the same microfluidic device.  相似文献   

5.
A new method for the determination of radiostrontium in large soil samples has been developed at the Savannah River Environmental Laboratory (Aiken, SC, USA) that allows rapid preconcentration and separation of strontium in large soil samples for the measurement of strontium isotopes by gas flow proportional counting. The need for rapid analyses in the event of a radiological dispersive device or improvised nuclear device event is well-known. In addition, the recent accident at Fukushima Nuclear Power Plant in March, 2011 reinforces the need to have rapid analyses for radionuclides in environmental samples in the event of a nuclear accident. The method employs a novel pre-concentration step that utilizes an iron hydroxide precipitation (enhanced with calcium phosphate) followed by a final calcium fluoride precipitation to remove silicates and other matrix components. The pre-concentration steps, in combination with a rapid Sr Resin separation using vacuum box technology, allow very large soil samples to be analyzed for 89,90Sr using gas flow proportional counting with a lower method detection limit. The calcium fluoride precipitation eliminates column flow problems typically associated with large amounts of silicates in large soil samples.  相似文献   

6.
Choi S  Ku T  Song S  Choi C  Park JK 《Lab on a chip》2011,11(3):413-418
A gentle, but fast means for low-stress, high-throughput platelet purification is of significant clinical and biotechnological utility. Current implementations to sort platelets, however, require an external physical field, specialized buffer, or the harsh separation condition of high shear stress that tends to cause platelet stimulation. Here we report the use of hydrophoretic size separation in a wider channel and its parallelization to augment its throughput capability, maintaining physiological shear-stress range. We demonstrate a parallelized device comprising 10 stacks of the wide-channel hydrophoresis device, yielding a throughput of 2.9 million cells s(-1) and a platelet purity of 76.8%. The use of the wide channel for hydrophoresis also facilitates clogging-free separation by sorting blood clots and plaques. The wide-channel hydrophoresis offers the potential for gentle, fast, clogging-free sorting of rare blood cells with extreme throughput capabilities.  相似文献   

7.
We present a simple lab-on-chip device for handling small samples of delicate cells, e.g. stem cells. It uses a combination of sedimentation and dielectrophoresis. The transport of cells is driven by gravitation. Dielectrophoresis uses radio-frequency electric fields for generating particle-selective forces dependent on size and polarisability. Electrodes along the channels hold particles and/or cells in a defined position and deflect them towards different outlets. The absence of external pumping and the integration of injection and sampling ports allow the processing of tiny sample volumes. Various functions are demonstrated, such as contact-free cell trapping and cell/particle sorting. Pairs of human cells and antibody-coated beads, as they are formed for T cell activation, are separated from unbound beads. The cells experience only low stress levels compared with the stress levels in dielectrophoresis systems, where transport depends on external pumping. Our device is a versatile yet simple tool that finds applications in cellular biotechnology, in particular when an economic solution is required. Figure A simple gravitation-driven lab-on-chip device for the separation of mixed populations of microparticles or cells by negative dielectrophoresis.  相似文献   

8.
Microfluidic cell sorter allows efficient separation of small number of cells, which is beneficial in handling cells, especially primary cells that cannot be expanded to large populations. Here, we demonstrate a microfluidic fluorescence-activated cell sorter (μFACS) with a novel sorting mechanism, in which automatic on-chip sorting is realized by turning on/off the hydrodynamic gating valve when a fluorescent target is detected. Formation of the hydrodynamic gating valve was investigated by both numerical simulation and flow visualization experiment. Separation of fluorescent polystyrene beads was then conducted to evaluate this sorting mechanism and to optimize the separation conditions. Isolation of fluorescent HeLa-DsRed cells was further demonstrated with high purity and recovery rate. Viability of the sorted cells was also examined, suggesting a survival rate of more than 90%. We expect this sorting approach to find widespread applications in bioanalysis.  相似文献   

9.
A novel microfluidic method of continually detecting and counting beads‐labeled cells from a cell mixture without fluorescence labeling was presented in this paper. The detection system is composed of a microfluidic chip (with a permanent magnet inserted along the channel), a signal amplification circuit, and a LabView® based data acquisition device. The microfluidic chip can be functionally divided into separation zone and detection zone. By flowing the pre‐labeled sample solution, the target cells will be sequentially separated at the separation zone by the permanent magnet and detected and counted at the detection zone by a microfluidic resistive pulse sensor. Experiments of positive separation and detection of T‐lymphocytes and negative separation and detection of cancer cells from the whole blood samples were carried out to demonstrate the effectiveness of this method. The methodology of utilizing size difference between magnetic beads and cell‐magnetic beads complex for beads‐labeled cell detection is simple, automatic, and particularly suitable for beads‐based immunoassay without using fluorescence labeling.  相似文献   

10.
Prieto JL  Lu J  Nourse JL  Flanagan LA  Lee AP 《Lab on a chip》2012,12(12):2182-2189
We present an automated dielectrophoretic assisted cell sorting (DACS) device for dielectric characterization and isolation of neural cells. Dielectrophoretic (DEP) principles are often used to develop cell sorting techniques. Here we report the first statistically significant neuronal sorting using DACS to enrich neurons from a heterogeneous population of mouse derived neural stem/progenitor cells (NSPCs) and neurons. We also study the dielectric dispersions within a heterogeneous cell population using a Monte-Carlo (MC) simulation. This simulation model explains the trapping behavior of populations as a function of frequency and predicts sorting efficiencies. The platform consists of a DEP electrode array with three multiplexed trapping regions that can be independently activated at different frequencies. A novel microfluidic manifold enables cell sorting by trapping and collecting cells at discrete frequency bands rather than single frequencies. The device is used to first determine the percentage of cells trapped at these frequency bands. With this characterization and the MC simulation we choose the optimal parameters for neuronal sorting. Cell sorting experiments presented achieve a 1.4-fold neuronal enrichment as predicted by our model.  相似文献   

11.
崔嘉轩  刘璐  李东浩  朴相范 《色谱》2021,39(11):1157-1170
微纳尺度物质的分离和分选在精准医学、材料科学和单细胞分析等研究中至关重要。精准、高效和快速的分离微纳尺度物质能够为癌症的早期诊断、生物样品检测和细胞筛选提供重要帮助,其中基于外加场分离技术的分离微纳尺度物质因可以对微纳尺度物质高效在线分离和分选,被广泛应用于微纳米颗粒、外泌体以及生物细胞的分离工作中,而目前多数外加场分离技术存在装备繁琐和样品消耗大等问题。微流控技术是一种通过制作微通道和微流控芯片操纵微小流体对微纳尺度样品组分进行分离的技术,因具有快速检测、高通量、在线分离、集成性高、成本低等优势现被应用于微纳尺度物质分离分析中,是一种微纳尺度物质分离的有效方法,通过在微流控芯片上设计不同的通道及外部配件提高主动场对微纳尺度物质分离效率。外加场分离技术与微流控技术联用可以实现微纳尺度物质的无损、高效、在线分离。该综述主要概述了近年来在微流控芯片上依托流动场、电场、磁场及声场等外加场分离技术来提高对微纳尺度物质分离效率的研究现状,并将各个外力场对单细胞、微颗粒等微纳尺度物质的分离进行分类介绍,总结各自的优缺点及发展应用,最后展望了外加场分离技术与微流控技术联用在应用于癌细胞的早期筛查、精确分离微尺度物质领域的未来发展前景,并提出联用技术的优势和未来应用等。  相似文献   

12.
Microfluidic technologies for isolating cells of interest from a heterogeneous sample have attracted great attentions, due to the advantages of less sample consumption, simple operating procedure, and high separation accuracy. According to the working principles, the microfluidic cell sorting techniques can be categorized into biochemical (labeled) and physical (label‐free) methods. However, the inherent drawbacks of each type of method may somehow influence the popularization of these cell sorting techniques. Using the multiple complementary isolation principles is a promising strategy to overcome this problem, therefore there appears to be a continuing trend to integrate two or more sorting methods together. In this review, we focus on the recent advances in microfluidic cell sorting techniques relied on both physical and biochemical principles, with emphasis on the mechanisms of cell separation. The biochemical cell sorting techniques enhanced by physical principles and the physical cell sorting techniques enhanced by biochemical principles, are first introduced. Then, we highlight on‐chip magnetic‐activated cell sorting, on‐chip fluorescence‐activated cell sorting, multi‐step cell sorting and multi‐principle cell sorting techniques, which are based on both physical and biochemical separation mechanisms. Finally, the challenges and future perspectives of the integrated microfluidics for cell sorting are discussed.  相似文献   

13.
The ability to generate a sample of cells of a given phenotype is a prerequisite for many cellular assays. In response to this growing need, numerous methods for cell separation have been developed in recent years. This Review covers recent progress in the field of cell separations and cell chromatography. Cell separation principles—such as size and affinity capture—are discussed, as well as conventional methods such as fluorescence-activated cell sorting and magnetic sorting. Planar flow cell arrays, dielectrophoresis, field-flow methods, and column separation devices are reviewed, as well as applications of these methods to medicine and biotechnology. Cell attachment and adhesion strategies and a comparison of techniques are also presented.  相似文献   

14.
We present a passive microfluidic strategy for sorting adult C. elegans nematodes on the basis of age and size. The separation mechanism takes advantage of phenotypic differences between 'adult' and 'juvenile' organisms and their behaviour in microfluidic architectures. In brief, the microfluidic device allows worms to sort themselves in a passive manner.  相似文献   

15.
This work explores dielectrophoresis (DEP)‐active hydrophoresis in sorting particles and cells. The device consists of prefocusing region and sorting region with great potential to be integrated into advanced lab‐on‐a‐chip bioanalysis devices. Particles or cells can be focused in the prefocusing region and then sorted in the sorting region. The DEP‐active hydrophoretic sorting is not only based on size but also on dielectric properties of the particles or cells of interest without any labelling. A mixture of 3 and 10 μm particles were sorted and collected from corresponding outlets with high separation efficiency. According to the different dielectric properties of viable and nonviable Chinese Hamster Ovary (CHO) cells at the medium conductivity of 0.03 S/m, the viable CHO cells were focused well and sorted from cell sample with a high purity.  相似文献   

16.
Insulator‐based dielectrophoresis (iDEP) is a well‐known technique that harnesses electric fields for separating, moving, and trapping biological particle samples. Recent work has shown that utilizing DC‐biased AC electric fields can enhance the performance of iDEP devices. In this study, an iDEP device with 3D varying insulating structures analyzed in combination with DC biased AC fields is presented for the first time. Using our unique reactive ion etch lag, the mold for the 3D microfluidic chip is created with a photolithographic mask. The 3D iDEP devices, whose largest dimensions are 1 cm long, 0.18 cm wide, and 90 μm deep are then rapidly fabricated by curing a PDMS polymer in the glass mold. The 3D nature of the insulating microstructures allows for high trapping efficiency at potentials as low as 200 Vpp. In this work, separation of Escherichia coli from 1 μm beads and selective trapping of live Staphylococcus aureus cells from dead S. aureus cells is demonstrated. This is the first reported use of DC‐biased AC fields to selectively trap bacteria in 3D iDEP microfluidic device and to efficiently separate particles where selectivity of DC iDEP is limited.  相似文献   

17.
We developed a low-cost polymer-film spiral inertial microfluidic device for the effective size-dependent separation of malignant tumor cells. The device was fabricated in polymer films by rapid laser cutting and chemical bonding. After fabricating the prototype device, the separation performance of our device was evaluated using particles and cells. The effects of operational flow rate, cell diameter, and cell concentration on the separation performance were explored. Our device successfully separated tumor cells from polydisperse white blood cells according to their different migration modes and lateral positions. Then, the separation of rare cells was carried out using the high-concentration lysed blood spiked with 200 tumor cells. Experimental results showed that 83.90% of the tumor cells could be recovered, while 99.87% of white blood cells could be removed. We successfully employed our device for processing clinical pleural effusion samples from patients with advanced metastatic breast cancer. Malignant tumor cells with an average purity of 2.37% could be effectively enriched, improving downstream diagnostic accuracy. Our device offers the advantages of label-free operation, low cost, and fast fabrication, thus being a potential tool for effective cell separation.  相似文献   

18.
Peripheral blood can provide valuable information on an individual’s immune status. Cell‐based assays typically target leukocytes and their products. Characterization of leukocytes from whole blood requires their separation from the far more numerous red blood cells. 1 Current methods to classify leukocytes, such as recovery on antibody‐coated beads or fluorescence‐activated cell sorting require long sample preparation times and relatively large sample volumes. 2 A simple method that enables the characterization of cells from a small peripheral whole blood sample could overcome limitations of current analytical techniques. We describe the development of a simple graphene oxide surface coated with single‐domain antibody fragments. This format allows quick and efficient capture of distinct WBC subpopulations from small samples (~30 μL) of whole blood in a geometry that does not require any specialized equipment such as cell sorters or microfluidic devices.  相似文献   

19.
Liu S  Elkin C  Kapur H 《Electrophoresis》2003,24(21):3762-3768
We describe a microfabricated hybrid device that consists of a microfabricated chip containing multiple twin-T injectors attached to an array of capillaries that serve as the separation channels. A new fabrication process was employed to create two differently sized round channels in a chip. Twin-T injectors were formed by the smaller round channels that match the bore of the separation capillaries and separation capillaries were incorporated to the injectors through the larger round channels that match the outer diameter of the capillaries. This allows for a minimum dead volume and provides a robust chip/capillary interface. This hybrid design takes full advantage, such as sample stacking and purification and uniform signal intensity profile, of the unique chip injection scheme for DNA sequencing while employing long straight capillaries for the separations. In essence, the separation channel length is optimized for both speed and resolution since it is unconstrained by chip size. To demonstrate the reliability and practicality of this hybrid device, we sequenced over 1000 real-world samples from Human Chromosome 5 and Ciona intestinalis, prepared at Joint Genome Institute. We achieved average Phred20 read of 675 bases in about 70 min with a success rate of 91%. For the similar type of samples on MegaBACE 1000, the average Phred20 read is about 550-600 bases in 120 min separation time with a success rate of about 80-90%.  相似文献   

20.
Often, in semen samples with minute amounts of sperm, even the single spermatozoon required to fertilize an oocyte cannot be found in the ejaculate. This is primarily because currently, sperm is generally searched for manually under a microscope. In this study, dielectrophoresis (DEP) was investigated as an alternative automated technique for sorting sperm cells. Using a quadrupolar electrode array it was shown that the head and tail of the sperm had independent and unique crossover frequencies corresponding to the transition of the DEP force from repulsive (negative) to attractive (positive). These surprising results were further analyzed, showing that the head and tail have their own distinct electrical properties. This significant result allows for the sperm's head, which contains the DNA, to be distanced from potentially damaging high electric fields using negative DEP while simultaneously manipulating and sorting the sperm using the positive DEP response of the tail. A proof of concept sorting chip was designed and tested. The low crossover frequency of the tail also allows for the use of a higher conductivity, and thus more physiological, medium than the conventional DEP solutions. Although more research is required to design and optimize an efficient, user‐friendly, and high‐throughput device, this research is a proof of concept that DEP has the potential to automate and improve the processing of semen samples, especially those containing only rare spermatozoa.  相似文献   