首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A reliable and sensitive method for simultaneous determination of perchloroethylene (PCE), trichloroethylene (TCE), and trichloroacetic acid (TCA) in human urine by gas chromatography-mass spectrometry (GC/MS) is described after extraction and preconcentration by a new solid-phase microextraction (SPME) adsorbent. The potential of single-walled carbon nanotubes (SWCNTs) as SPME adsorbent for the pre-concentration of environmental pollutants has been investigated in recent years. This work was carried out to investigate the feasibility of SWCNTs as a headspace SPME adsorbent for the determination of chloroethylenes in human urine. SWCNTs were attached onto a stainless steel wire through an organic binder. Potential factors affecting the extraction efficiency, including extraction time, extraction temperature, desorption time, desorption temperature, and salinity were optimized. The developed method showed good performance. For PCE and TCE, calibration curves were linear (r 2 ?≥?0.994) over the concentration ranges from 15 to 8000?ng?L?1 and the limit of detection (LOD) at signal-to-noise (S/N) ratio of 3 was 5?ng?L?1. The analytical procedure also involves derivatization of TCA with dimethyl sulfate, before headspace sampling. For TCA the linear range and LOD were 45-8000 (r 2 ?≥?0.992) and 15?ng L?1, respectively. In addition, a comparative study between the SWCNT and a commercial carboxen/polydimethylsiloxane (CAR/PDMS) SPME fibre for the determination of chloroethylenes in human urine was carried out. SWCNT fibre showed higher extraction capacity, better thermal stability (over 350°C) and longer life span (over 200 times) than the commercial CAR/PDMS fibre. The developed method was successfully applied to determine chloroethylenes in human urine samples. As the results indicated, the mean concentrations of TCE, PCE and TCA in exposed workers (dry-cleaning industry workers) were significantly greater than that of control group.  相似文献   

2.
Trichloroethylene (TCE) and some of its metabolites are potentially carcinogenic compounds that the general population is commonly exposed to in drinking water. Concentrations of TCE, dichloroacetic acid (DCA) and trichloroacetic acid (TCA) given to laboratory animals in cancer bioassays are high, whereas drinking water levels of the compounds are very low. It is not clear whether the trace amounts of TCE, DCA and TCA in drinking water pose a cancer risk to humans. The accuracy of pharmacokinetic studies relies on the analytical method from which blood and tissue concentration data are obtained. Models that extrapolate cancer risks of TCE and its metabolites from laboratory animals to humans, in turn, rely on the results of pharmacokinetic studies. Therefore, it is essential to have reliable analytical methods for the analysis of TCE and its metabolites. This paper reviews the methods currently in the literature for the analysis of TCE, DCA, TCA and, to a lesser extent, chloral hydrate (CH). Additional aspects of analytical methods such as method validation, species preservation and future directions in the analysis of TCE and its metabolites are also discussed.  相似文献   

3.
The simultaneous determination of several odorous trichlorobromophenols in water has been carried out by an in-sample derivatization headspace solid-phase microextraction method (HS-SPME).The analytical procedure involved their derivatization to methyl ethers with dimethyl sulfate/NaOH and further HS-SPME and gas chromatography-mass spectrometry (GC/MS) determination. Parameters affecting both the derivatization efficiency and headspace SPME procedures, such as the selection of the SPME fiber coating, derivatization–extraction time and temperature, were studied. The commercially available polydimethylsiloxane (PDMS) 100 μm and Carboxen-polydimethylsiloxane-divinylbenzene (CAR-PDMS-DVB) fibers appeared to be the most suitable for the simultaneous determination of these compounds. The precision of the HS-SPME/GC/MS method gave good relative standard deviations (RSDs) run-to-run between 9% and 19% for most of them, except for 2,5-diCl-6-Br-phenol, 2,6-diCl-3-Br-phenol and-2,3,6-triBr-phenol (22%, 25% and 23%, respectively). The method was linear over two orders of magnitude, and detection limits were compound dependent but ranged from 0.22 ng/l to 0.95 ng/l. The results obtained for water samples using the proposed SPME procedure were compared with those found with the EPA 625 method, and good agreement was achieved. Therefore, the in-sample derivatization HS-SPME/GC/MS procedure here proposed is a suitable method for the simultaneous determination of odorous trichlorobromophenols in water.  相似文献   

4.
Dichloroacetic acid (DCA) is a compound found in chlorinated drinking water. In addition, the compound is a metabolite of several halogenated solvents, including trichloroethylene (TCE) and perchloroethylene (PCE). Exposure to DCA is of concern because high doses of the compound have been shown to cause cancer in laboratory animals. Dosages of TCE administered to animals in cancer studies are designed to elicit maximal DCA formation in vivo, whereas levels of DCA to which individuals are exposed in drinking water are very low. Analysis of DCA in biological samples has been quite challenging. Derivatizing reagents commonly used to convert DCA into a more volatile form for analysis by gas chromatography (GC) have been found to convert trichloroacetic acid (TCA), a major metabolite of TCE and PCE, into DCA. High-performance liquid chromatography (HPLC) analysis does not require derivatization of DCA and can thus avoid this problem. However, the most popular stationary phases in HPLC columns do not retain small, polar compounds such as DCA well. The liquid chromatography/tandem mass spectrometry (LC/MS/MS) method described in this paper uses hydrophilic interaction liquid chromatography (HILIC), a type of chromatography that is able to retain these small, polar compounds. Method validation was performed using the United States Food and Drug Administration (USFDA) and International Conference on Harmonziation (ICH) Guidance for Industry: Bioanalytical Method Validation as a guide. Levels of DCA found in rats dosed with 2 g/kg TCE were 17.2 ng/mL (liver), 262.4 ng/mL (kidney), 175.1 ng/mL (lung), and 39.5 ng/mL (blood).  相似文献   

5.
Headspace solid-phase microextraction (SPME) was studied as a possible alternative to liquid-liquid extraction for the analysis of haloacetic acids (HAAs) in water. The method involves derivatization of the acids to their ethyl esters using sulphuric acid and ethanol after evaporation, followed by headspace SPME with a polydimethylsiloxane fibre and gas chromatography-ion trap mass spectrometry (GC-IT-MS). The derivatization procedure was optimized: maximum sensitivity was obtained with esterification for 10 min at 50 degrees C in 30 microl of sulphuric acid and 40 microl of ethanol. The headspace SPME conditions were also optimized and good sensitivity was obtained at a sampling temperature of 25 degrees C, an absorption time of 10 min, the addition of 0.1 g of anhydrous sodium sulfate and a desorption time of 2 min. Good precision (RSD lower than 10%) and detection limits in the ng l(-1) range (from 10 to 200 ng l(-1)) were obtained for all the compounds. The optimized procedure was applied to the analysis of HAAs in tap water and the results obtained by standard addition agreed with those of EPA method 552.2, whereas discrepancies due to matrix interferences were observed using external calibration. Consequently, headspace SPME-GC-IT-MS with standard addition is recommended for the analysis of these compounds in drinking water.  相似文献   

6.
Aldehydes are considered potential markers for enhanced oxidative stress and have been proposed as a diagnostic measure of cancer status. Do to their volatility and activity, it is very difficult to accurately measure aldehydes in human blood. In the present work, gas chromatography/mass spectrometry (GC/MS) and solid-phase microextraction (SPME) with on-fiber derivatization was developed for determination of aldehydes in human blood. O-(2,3,4,5,6-Pentafluorobenzyl)hydroxylamine hydrochloride (PFBHA) in aqueous solution was first adsorbed by a SPME fiber, and then the aldehydes in blood samples were headspace extracted by the SPME fiber and rapidly derivatized with PFBHA on the SPME fiber. Finally, the oximes formed were desorbed and detected by GC/MS in electron ionization (EI) mode. Validation of the present method was carried out, and the method was applied to quantitative analysis of the aldehydes in lung cancer blood. The results demonstrated that GC/MS and SPME with on-fiber derivatization is a simple, rapid, sensitive and solvent-free method for the determination of aldehydes in human blood.  相似文献   

7.
In this study, a simple, rapid, and sensitive method was developed and validated for the quantification of valproic acid (VPA), an antiepileptic drug, in human plasma, which was based on water-phase derivatization followed by headspace solid-phase microextraction (HS-SPME) and gas chromatography/mass spectrometry (GC/MS). In the proposed method, VPA in plasma was rapidly derivatized with a mixture of isobutyl chloroformate, ethanol and pyridine under mild conditions (room temperature, aqueous medium), and the VPA ethyl ester formed was headspace-extracted and simultaneously concentrated using the SPME technique. Finally, the analyte extracted on SPME fiber was analyzed by GC/MS. The experimental parameters and method validations were studied. The optimal conditions were obtained: PDMS fiber, stirring rate of 1100 rpm, sample temperature of 80 degrees C, extraction time of 20 min, NaCl concentration of 30%. The proposed method had a limit of quantification (0.3 microg/mL), good recovery (89-97%) and precision (RSD value less than 10%). Because the proposed method combined a rapid water-phase derivatization with a fast, simple and solvent-free sample extraction and concentration technique of SPME, the sample preparation time was less than 25 min. This much shortens the whole analysis time of VPA in plasma. The validated method has been successfully used to analyze VPA in human plasma samples for application in pharmacokinetic studies. All these results show that water-phase derivatization followed by HS-SPME and GC/MS is an alternative and powerful method for fast determination of VPA in biological fluids.  相似文献   

8.
A method for the determination of organotin compounds (monobutyl = MBT, dibutyl = DBT, and tributyltin = TBT) in marine sediments by headspace Solid Phase Microextraction (SPME) has been developed. The analytical procedure involved 1) extraction of TBT, DBT and MBT from sediments with HCl and methanol mixture, 2) in situ derivatization with sodium tetraethylborate and 3) headspace SPME extraction using a fiber coated with poly(dimethylsiloxane). The derivatized organotin compounds were desorbed into the splitless injector and simultaneously analyzed by gas chromatography - mass spectrometry. The analytical method was optimized with respect to derivatization reaction and extraction conditions. The detection limits obtained for MBT, DBT and TBT ranged from 730 to 969 pg/g as Sn dry weight. Linear calibration curves were obtained for all analytes in the range of 30-1000 ng/L as Sn. Analysis of a standard reference sediment (CRM 462) demonstrates the suitability of this method for the determination of butyltin compounds in marine sediments. The application to the determination of TBT, DBT and MBT in a coastal marine sediment is shown.  相似文献   

9.
A gas chromatography/negative chemical ionization mass spectrometry (GC/NCIMS) method using headspace solid-phase microextraction (HS-SPME) was developed for the determination of trichloroethylene (TCE) in blood, liver, kidney, lung and brain. The method was optimized with respect to several parameters including extraction time, extraction temperature, desorption time and salt addition. The method showed good linearity over the range of 0.025-25 ng/mL in blood and 0.075-75 ng/g in tissues with correlation coefficient (R2) values higher than 0.99. The precision and accuracy for intra-day and inter-day measurements were less than 10%. The relative recoveries of all matrices were greater than 52%. Samples showed no significant loss during 8 h in the autosampler and following three freeze/thaw cycles. Validation results demonstrated that selected-ion monitoring of the 35Cl and 37Cl isotopes using NCI resulted in reliable and sensitive quantitation. This validated method was successfully applied to study the toxicokinetics of TCE following oral administration of extremely low doses of this potential human carcinogen to small test animals (rats).  相似文献   

10.
A method for the determination of organotin compounds (monobutyl = MBT, dibutyl = DBT, and tributyltin = TBT) in marine sediments by headspace Solid Phase Microextraction (SPME) has been developed. The analytical procedure involved 1) extraction of TBT, DBT and MBT from sediments with HCl and methanol mixture, 2) in situ derivatization with sodium tetraethylborate and 3) headspace SPME extraction using a fiber coated with poly(dimethylsiloxane). The derivatized organotin compounds were desorbed into the splitless injector and simultaneously analyzed by gas chromatography – mass spectrometry. The analytical method was optimized with respect to derivatization reaction and extraction conditions. The detection limits obtained for MBT, DBT and TBT ranged from 730 to 969 pg/g as Sn dry weight. Linear calibration curves were obtained for all analytes in the range of 30–1000 ng/L as Sn. Analysis of a standard reference sediment (CRM 462) demonstrates the suitability of this method for the determination of butyltin compounds in marine sediments. The application to the determination of TBT, DBT and MBT in a coastal marine sediment is shown.  相似文献   

11.
The purpose of this study was to develop a simple, rapid and sensitive analytical method for determination of amino acids in neonatal blood samples. The developed method involves the employment of derivatization and a solid-phase microextraction (SPME) technique together with gas chromatography/mass spectrometry (GC/MS). Amino acids in blood samples were derivatized by a mixture of isobutyl chloroformate, methanol and pyridine, and the N(O,S)-alkoxycarbonyl alkyl esters thus formed were headspace extracted by a SPME fiber. Finally, the extracted analytes on the fiber were desorbed and detected by GC/MS in electron impact (EI) mode. L-Valine, L-leucine, L-isoleucine, L-phenylanaline and L-tyrosine in blood samples were quantitatively analyzed by measurement of the corresponding N(O,S)-alkoxycarbonyl alkyl esters using an external standard method. SPME conditions were optimized, and the method was validated. The method was applied to diagnosis of neonatal phenylkenuria (PKU) and maple syrup urine disease (MSUD) by the analyses of five amino acids in blood samples. The results showed that the proposed method is a potentially powerful tool for simultaneous screening for neonatal PKU and MSUD.  相似文献   

12.
固相微萃取-GC-MS法测定水中的三苯胂和二苯胂酸   总被引:2,自引:0,他引:2  
建立了一种同时测定水中痕量三苯胂和二苯胂酸的方法,使用巯基乙酸甲酯作为二苯胂酸测定的衍生化试剂,固相微萃取耦合气相色谱-质谱法(选择离子监测)同时测定三苯胂和二苯胂酸。优化了萃取纤维丝、萃取时间、衍生化等操作条件。同时对混合物测定的回收率、相对标准偏差和最低检测限进行了研究。方法的回收率大于95%,最低检测质量浓度分别为0.0005和0.0003 mg/L,6次测定的相对标准偏差分别为5.3%、7.6%。  相似文献   

13.
A new method for determination of fluoride in toothpaste employing the headspace solid-phase microextraction (HS-SPME) followed by gas chromatography/flame ionization detection (GC/FID) has been proposed. It is a development of the method for determination of fluoride using trimethylchlorosilane (TMCS) as the derivatization reagent to form trimethylfluorosilane (TMFS), with the liquid/liquid extraction (LLE) step replaced by HS-SPME. To introduce the latter, it was necessary to determine the conditions of the reaction and to optimize the two stages of the SPME procedure: extraction and desorption. The parameters of the SPME analysis using carboxen/polydimethylsiloxane (CAR/PDMS) fiber were defined and compared with the corresponding ones for the LLE method, used as a reference. Also, these two methods were compared with respect to their linearity, precision, and accuracy. Results from toothpaste analyses using these two methods were highly correlated, indicating the potential to use the SPME extraction as an inexpensive and solventfree alternative to the LLE method.  相似文献   

14.
This study evaluates solid-phase microextraction (SPME) coupled with gas chromatography-mass spectrometry (GC-MS) to determine trace levels of amphetamine and methamphetamine in serum. Headspace post-derivatization in a laboratory-made design with heptafluorobutyric anhydride vapor following SPME was compared with that without derivatization SPME. The SPME experimental procedures to extract amphetamine and methamphetamine in serum were optimized with a relatively non-polar poly(dimethylsiloxane) coated fiber at pH 9.5, extraction time for 40 min and desorption at 260 degrees C for 2 min. Experimental results indicate that the concentration of the serum matrix diluted to a quarter of original (1:3) ratio by using one volume of buffer solution of boric acid mixed with sodium hydroxide and two volumes of water improves the extraction efficiency. Headspace derivatization following SPME was performed by using 6 microl 20% (v/v) heptafluorobutyric anhydride ethyl acetate solution at an oil bath temperature of 270 degrees C for 10 s. The precision was below 7% for analysis for without derivatization and below 17% for headspace derivatization. Detection limits were obtained at the ng/l level, one order better obtained in headspace derivatization than those achieved without derivatization. The feasibility of applying the methods to determine amphetamine and methamphetamine in real samples was examined by analyzing serum samples from methamphetamine abused suspects. Concentrations of the amphetamine and methamphetamine ranged from 6.0 microg/l (amphetamine) to 77 microg/l (methamphetamine) in serum.  相似文献   

15.
In this work, a novel technique of aqueous-phase derivatization followed by headspace solid-phase microextraction and gas chromatography-mass spectrometry was developed for the determination of organic acids in urine. The analytical procedure involves derivatization of organic acids to their ethyl esters with diethyl sulfate, headspace sampling, and GC/MS analysis. The proposed method was applied to the determination of methylmalonic acid and glutaric acid in urine. The experimental parameters and method validation were studied. Optimal conditions were obtained: PDMS fiber, extraction temperature 55 degrees C, extraction time 30 min, and 60 microL of diethyl sulfate as derivatization reagent with 2 mg of the ion pairing agent tetrabutylammonium hydrogensulfate. The method was linear over three orders of magnitude, and detection limits were 21 nM for methylmalonic acid and 34 nM for glutaric acid, respectively. Consequently, in-situ derivatization/HS-SPME/GC/MS is an alternative and powerful method for determination of organic acids as biomarkers in biological fluids.  相似文献   

16.
A method for the extraction and gas chromatographic determination of methylmercury in biological matrices is presented. By combining the advantages of two extraction techniques-microwave-assisted extraction (MAE) and solid-phase microextraction (SPME)--the separation of methylmercury from biological samples is possible. Specifically, the procedure involves microwave extraction with 3 M hydrochloric acid, followed by aqueous-phase derivatization with sodium tetraphenylborate and headspace SPME with a silica fibre coated with polydimethylsiloxane (PDMS). For optimization of the derivatization-SPME procedure, a central composite experimental design with alpha = 1.682 and two central points was used to model gas-chromatographic peak areas as functions of pH, extraction temperature and sorption time. A desirability function was then used for the simultaneous optimization for methylmercury and Hg(II). The optimal derivatization-SPME conditions identified were close to pH 5, temperature 100 degrees C, and sorption time 15 min. The identification and quantification of the extracted methylmercury is carried out by gas chromatography with microwave-induced plasma atomic emission spectrometry detection. The validity of the new procedure is shown by the results of analyses of certified reference materials.  相似文献   

17.
A sensitive and solvent-free procedure for the determination of non-steroidal acidic anti-inflammatory drugs in water samples was optimized using solid-phase microextraction (SPME) followed by on-fiber silylation of the acidic compounds and gas chromatography-mass spectrometry (GC-MS) determination. Microextraction was carried out directly over the filtered water samples using a polyacrylate fiber. Derivatization was performed placing the SPME fiber, loaded with the extracted analytes, in the headspace of a vial containing 50 microl of N-methyl-N-(tert-butyldimethylsilyl)-trifluoroacetamide (MTBSTFA). Derivatives were desorbed for 3 min in the GC injector. Influence of several parameters in the efficiency of microextraction (volume of sample, time, pH, type of fiber coating, etc.) and derivatization steps (time, temperature and volume of MTBSTFA) was systematically investigated. In the optimal conditions an excellent linearity over three orders of magnitude and quantification limits at the ng/l level (from 12 to 40 ng/l) were achieved. The proposed method was applied to the determination of acidic compounds in sewage water and results compared to those obtained using solid-phase extraction (SPE) followed by the derivatization of the compounds in the organic extract of the solid-phase extraction cartridge.  相似文献   

18.
A method for trace analysis of a wide range of aldehydes (saturated/unsaturated aliphatic, aromatic aldehydes, including hydroxylated species, and dialdehydes) in an aqueous solution was optimized. An evaluation of three solid-phase microextraction (SPME) techniques (headspace, liquid-phase, and on-fiber derivatization) with o-(2,3,4,5,6-pentafluorobenzyl)hydroxylamine hydrochloride (PFBHA) aldehyde derivatization was performed focusing on the optimization of the main extraction parameters (temperature and time). The optimized method employed the liquid-phase SPME (D-L-SPME) of derivatized aldehydes at 80 degrees C for 30 min. Limits of detection (LODs) using this optimal method were in the range of 0.1-4.4 microg/L for the majority of aliphatic (saturated, unsaturated), aromatic aldehydes and dialdehydes. Formaldehyde LODs and those of some hydroxylated aromatic aldehydes were between 32 and 55 microg/L. Headspace SPME using an on-fiber derivatization generally showed a lower sensitivity and several compounds were not detected. Another technique, the optimized headspace SPME of aldehydes derivatized in aqueous solution, was not as sensitive as D-L-SPME for hydroxylated aromatic aldehydes. The developed method was used to analyze aqueous particulate matter extracts; this method achieved higher sensitivities than those obtained with US Environmental Protection Agency (EPA) Method 556.  相似文献   

19.
A direct solid-phase microextraction (SPME) procedure has been developed and applied for the simultaneous determination of nonylphenol, nonylphenol mono- and diethoxylates and their brominated derivatives in raw and treated water at low microg l(-1) concentrations. Several parameters affecting the SPME procedure, such as extraction mode (headspace or direct-SPME), selection of the SPME coating, extraction time, addition of organic modifiers such as methanol and temperature were optimized. The divinylbenzene-carboxen-polydimethylsiloxane fiber was the most appropriate one for the determination of nonylphenol ethoxylates (NPEOs) and bromononylphenol ethoxylates (BrNPEOs) by SPME-GC-MS. The optimized method was linear over the range studied (0.11-2.5 microg l(-1)) and showed good precision, with RSD values between 4 and 15% and detection limits ranging from 30 to 150 ng l(-1) depending on the compound. The SPME procedure was compared with a solid-phase extraction-GC-MS method (C18 cartridge) for the analysis of NPEO and BrNPEOs in water samples. There was good agreement between the results from both methods but the SPME procedure showed some advantages such as lower detection limits, a shorter analysis time and the avoidance of organic solvents. The optimized SPME method was applied to determine nonylphenol and brominated metabolites in raw and treated water of Barcelona (NE Spain).  相似文献   

20.
A headspace solid‐phase microextraction (HS‐SPME) method coupled to GC‐MS was developed in order to determine trace levels of tetramethyltin (TeMT) and inorganic tin (iSn) after ethylation to tetraethyltin (TeET) in various matrices. The derivatization of iSn and the extraction of both TeMT and iSn as TeET were performed in one step. Sodium tetraethylborate (NaBEt4) was used as derivatization agent and the volatile derivatives were absorbed on a PDMS‐coated fused silica fiber. The conditions for the HS‐SPME procedure were optimized in order to gain in repeatability and sensitivity. Several critical parameters of GC‐MS were also studied. The detection of TeMT and iSn as TeET peaks was performed by the SIM mode. The precision of the proposed method is satisfactory providing RSD values below 10% for both tin species and good linearity up to 10 μg/L. The developed method was successfully applied to the determination of tin species in several samples like canned fish, fish tissues, aquatic plants, canned mineral water and sea water. The proposed HS‐SPME‐GC‐MS method was proved suitable to monitor the concentration levels of toxic tin compounds in environmental and biological samples.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号