1.
A convenient, selective and sensitive liquid chromatographic-electrospary ionization mass spectrometry (LC–ESI–MS) method was developed and validated to determine lovastatin in human plasma. The analyte was extracted from human plasma samples by typical liquid–liquid extraction, separated on a C18 column by using the mobile phase consisting of water–methanol (13:87, v/v). Simvastatin was used as the internal standard (IS). The method was linear within the range of 0.1–20 ng mL−1. The lower limit of quantification (LLOQ) was 0.1 ng mL−1. The intra- and inter-run precision, calculated from quality control (QC) samples was less than 10.2%. The accuracy as determined from QC samples was in the range of 99.3–102.9% for the analyte. The mean recoveries for lovastatin and IS were 84.8 and 88.0%, respectively. The method was successfully applied for evaluation of the pharmacokinetic of lovastatin in healthy volunteers.  相似文献   

2.
A rapid, sensitive, and accurate high-performance liquid-chromatographic–mass spectrometric (HPLC–MS) method, with estazolam as internal standard, has been developed and validated for determination of aripiprazole in human plasma. After liquid–liquid extraction the compound was analyzed by HPLC on a C18 column, with acetonitrile—30 mm ammonium acetate containing 0.1% formic acid, 58:42 (v/v), as mobile phase, coupled with electrospray ionization mass spectrometry (ESI-MS). The protonated analyte was quantified by selected-ion recording (SIR) with a quadrupole mass spectrometer in positive-ion mode. Calibration plots were linear over the concentration range 19.9–1119.6 ng mL−1. Intra-day and inter-day precision (CV%) and accuracy (RE%) for quality-control samples (37.3, 124.4, and 622.0 ng mL−1) ranged between 2.5 and 9.0% and between 1.3 and 3.5%, respectively. Extraction recovery of aripiprazole from plasma was in the range 75.8–84.1%. The method enables rapid, sensitive, precise, and accurate measurement of the concentration of aripiprazole in human plasma.  相似文献   

3.
A rapid and simple high performance liquid chromatographic method coupled with tandem mass spectrometry (LC–MS–MS) via electrospray ionization (ESI) has been developed and validated to separate and simultaneously quantify sodium ferulate (SF), salicylic acid (SA), cinnarizine (CIN) and vitamin B1 (VB1) in human plasma. Gemfibrozil (GEM) was used as the internal standard (IS) for SF and SA, whereas lomerizine (LOM) was used as the IS for CIN and VB1. The plasma samples were prepared by one-step protein precipitation followed by an isocratic elution with 10 mM ammonium acetate buffer (pH = 5.0): acetonitrile (35:65, v/v,) on an Agilent Zorbax SB-CN column (150 mm × 2.0 mm ID, 5 μm). The precursor and product ions of these drugs were monitored on a triple quadrupole mass spectrometer, operating in the selected reaction monitoring mode (SRM) with polarity switch, in the negative-ion mode for SF, SA and GEM, in the positive-ion mode for CIN, VB1 and LOM. The method was validated over the concentration range of 1.5–1,000 ng mL−1 for SF, 20–5,000 ng mL−1 for SA, 2–500 ng mL−1 for CIN, 1–30 ng mL−1 for VB1. The intra- and inter-batch precisions were less than 15% of the relative standard deviation. The recoveries for analytes and IS achieved from spiked plasma samples were consistent and reproducible. The validated LC–MS–MS method has been successfully applied to the pharmacokinetic study of sodium ferulate and aspirin capsule in healthy volunteers.  相似文献   

4.
To evaluate the pharmacokinetics of a novel analogue of ginkgolide B, 10-O-dimethylaminoethylginkgolide B (XQ-1) in rat plasma in pre-clinical studies, a sensitive and specific liquid chromatographic method with electrospray ionization mass spectrometry detection (LC–ESI–MS) was developed and validated. After a simple extraction with ethyl acetate, XQ-1 was analyzed on a Shim-pack C18 column with a mobile phase of a mixture of 1 μmol L−1 ammonium acetate containing 0.02% formic acid and methanol (55:45, v/v) at a flowrate of 0.3 mL min−1. Detection was performed in selected ion monitoring (SIM) mode using target ions at [M + H]+ m/z 496.05 for XQ-1 and m/z 432.10 for the internal standard (lafutidine). Linearity was established for the concentration range from 2 to 1,000 ng mL−1 . The extraction recoveries ranged from 86.0 to 89.9% in plasma at concentrations of 5, 50, and 500 ng mL−1. The lower limit of quantification was 2 ng mL−1 with 100 μL plasma. The validated method was successfully applied to a pharmacokinetic study after intragastic administration of XQ-1 mesylate in rats at a dose of 20 mg kg−1.  相似文献   

5.
An analytical method based on liquid chromatography-tandem mass spectrometry (LC-MS-MS) was developed and validated for the determination of ezetimibe in human plasma. Ezetimibe and etoricoxib (internal standard) were extracted from the plasma by liquid-liquid extraction and separated on a C18 analytical column (50 × 3.0 mm I.D.) with acetonitrile:water (85:15, v/v) as mobile phase. Detection was carried out by positive electrospray ionization (ESI+) in multiple reaction monitoring (MRM) mode. The chromatographic separation was obtained within 2.0 min and was linear in the concentration range of 0.25–20ng mL−1 for free ezetimibe and of 1–300ng mL−1 for total ezetimibe. The mean extraction recoveries for free and total ezetimibe from plasma were 96.14 and 64.11%, respectively. Method validation investigated parameters such as linearity, precision, accuracy, specificity and stability, giving results within the acceptable range. The proposed method was successfully applied to the quantitation of ezetimibe and its glucuronide in human plasma to support clinical and pharmacokinetic studies. Moreover, the method was used for the quality control analysis of pharmaceutical dosage forms. Revised: 4 January and 3 February 2006  相似文献   

6.
A high-performance liquid chromatography–UV method for determining DCJW concentration in rat plasma was developed. The method described was applied to a pharmacokinetics study of intramuscular injection in rats. The plasma samples were deproteinized with acetonitrile in a one-step extraction. The HPLC assay was carried out using a VP-ODS column and the mobile phase consisting of acetonitrile–water (80:20, v/v) was used at a flow rate of 1.0 mL min−1 for the effective eluting DCJW. The detection of the analyte peak area was achieved by setting a UV detector at 314 nm with no interfering plasma peak. The method was fully validated with the following validation parameters: linearity range 0.06–10 μg mL−1 (r > 0.999); absolute recoveries of DCJW were 97.44–103.46% from rat plasma; limit of quantification, 0.06 μg mL−1 and limit of detection, 0.02 μg mL−1. The method was further used to determine the concentration–time profiles of DCJW in the rat plasma following intramuscular injection of DCJW solution at a dose of 1.2 mg kg−1. Maximum plasma concentration (C max) and area under the plasma concentration–time curve (AUC) for DCJW were 140.20 ng mL−1 and 2405.28 ng h mL−1.  相似文献   

7.
(E)-3,5,4′-trimethoxystilbene (BTM-0512) is a resveratrol analog with a variety of pharmacological action, including anti-cancer properties, anti-allergic activity, estrogenic activity, antiangiogenic activity, and vascular-targeting activity against microtubule-destabilization. There is, however, no validated analytical method for quantification of (E)-3,5,4′-trimethoxystilbene in biological matrices, so pharmacokinetic data and suitable methods for determination of the compound in plasma are currently lacking. A rapid and sensitive liquid chromatographic–mass spectrometric method for determination of (E)-3,5,4′-trimethoxystilbene in rat plasma, using carbamazepine as internal standard, has been developed and validated. Plasma samples were treated with acetonitrile to precipitate proteins. Samples were then analyzed by HPLC on a 250mm × 4.6 mm i.d., 5-μm particle, C18 column with methanol–water, 80:20 (v/v), containing 10 mm ammonium acetate and 0.2% formic acid (pH 3.0), as mobile phase, delivered at 0.85 mL min−1. A single-quadrupole mass spectrometer with an electrospray interface operated in selected-ion monitoring mode was used to detect [M + H]+ ions at m/z 271.3 for (E)-3,5,4′-trimethoxystilbene and m/z 237.5 for the internal standard. (E)-3,5,4′-trimethoxystilbene and the internal standard eluted as sharp, symmetrical peaks with retention times of 8.9 and 4 min, respectively. Calibration plots for (E)-3,5,4′-trimethoxystilbene in rat plasma at concentrations ranging from 0.01 to 5.0 μg mL−1 were highly linear. Intra-day and inter-day precision, as RSD, was <12.9%, and accuracy was in the range 94.8–104.7%. The limit of detection in plasma was 0.005 μg mL−1. The method was successfully used to determine the concentration of (E)-3,5,4′-trimethoxystilbene after oral administration of 86 mg kg−1 of the drug to Sprague–Dawley rats and can be used to investigate the pharmacokinetics of the compound.  相似文献   

8.
A rapid and sensitive method has been developed and validated to determine 6-benzyladenine (6-BA) residues in bean sprout using high-performance liquid chromatography coupled with electrospray ionization ion trap tandem mass spectrometry. Liquid–liquid extraction, using acidified methanol, was used to isolate 6-BA from the sample matrix. The separation was carried out on a Zorbax SB C18 column (150 mm × 4.6 mm i.d., 5 μm) with 0.1% acetic acid/methanol (25:75 v/v) as mobile phase in isocratic mode. The quantitation of 6-BA was based on fragmentation of the molecular ion at m/z 226.1 to a product ion at m/z 91.1. In addition, the recoveries of three extraction solvents by ultrasound extraction and conventional extraction method were compared, and it was found that acidified methanol as the extraction solvent was the best. The calibration curve was linear (r 2 > 0.997) in the concentration range of 0.04–10.0 ng mL−1 with a lower limit of quantification of 0.5 ng g−1 for 6-BA in bean sprout. Intra-day and inter-day relative standard deviations (RSDs) were less than 7.1 and 9.8%. Recoveries of 6-BA were between 85.0 and 88.5%. This assay has been successfully applied to the determination of trace 6-BA residues in bean sprout and monitoring the market in Ningbo, China.  相似文献   

9.
This study presents a high-performance liquid chromatography–electrospray ionization–mass spectrometric (LC–ESI–MS) method for the simultaneous determination of tramadol and acetaminophen in human plasma using phenacetinum as the internal standard. After alkalization with saturated sodium bicarbonate, both compounds were extracted from human plasma with ethyl acetate and were separated by HPLC on a Hanbon LiChrospher CN column with a mobile phase of 10 mM ammonium acetate buffer containing 0.5% formic acid–methanol (40:60, v/v) at a flow rate of 1 mL min−1. Analytes were determined using electrospray ionization in a single quadrupole mass spectrometer. LC–ESI–MS was performed in the positive selected-ion monitoring (SIM) mode using target ions at [M+H]+ m/z 264.3 for tramadol, [M+H]+ m/z 152.2 for acetaminophen and [M+H]+ m/z 180.2 for phenacetinum. Calibration curves were linear over the range of 5–600 ng mL−1 for tramadol and 0.03–16 μg mL−1 for acetaminophen. The inter-run relative standard deviations were less than 14.4% for tramadol and 12.3% for acetaminophen. The intra-run relative standard deviations were less than 9.3% for tramadol and 7.9% for acetaminophen. The mean plasma extraction recovery for tramadol and acetaminophen were in the ranges of 82.7–85.9 and 83.6–85.3%. The method was applied to study the pharmacokinetics of a new formulation of tramadol/acetaminophen tablet in healthy Chinese volunteers.  相似文献   

10.
A bioanalytical method has been developed and validated for determination of pregabalin in human plasma. The analytical method consists in the precipitation of plasma sample with trichloro acetic acid (20% v/v solution in water), followed by the determination of pregabalin by an LC-MS-MS method using gabapentin as internal standard. Separation was achieved on a Gemini C18 50 mm × 2.0 mm (3 μm) column with an isocratic mobile phase consisting of methanol–water (98:2, v/v) with 0.5% v/v formic acid. Protonated ions formed by a turbo ionspray in positive mode were used to detect analyte and internal standard. The MS-MS detection was by monitoring the fragmentation of 160.2→55.1 (m/z) for pregabalin and 172.2→67.1 (m/z) for gabapentin on a triple quadrupole mass spectrometer. The assay was calibrated over the range 0.1–15.0 μg mL−1 with correlation coefficient of 0.9998. Validation data showed intra-batch (n = 6) CV% ≤ 6.89 and RE (%) between −4.17 and +3.08 and inter-batch (n = 18) CV% < 9.09 and RE (%) between −3.0 and +10.00. Mean extraction recovery were 80.45–89.12% for three QC samples and 87.56% for IS. Plasma samples were stable for three freeze–thaw cycles, or 24 h ambient storage, or 1 and 3 months storage at −20 °C. Processed sample (ready for injection) were stable up to 72 h at autosampler (4 °C). This method has been used for analyzing plasma samples from a bioequivalence study with 18 volunteers.  相似文献   

11.
Olprinone is a phosphodiesterase (PDE)-3 inhibitor. This paper describes a simple, selective and sensitive method for the quantification of olprinone in rat plasma using a liquid–liquid extraction procedure followed by liquid chromatography mass spectrometric (LC–MS) analysis. The method had an advantage of high sensitivity. Analyses were conducted at a flow rate of 0.25 mL min−1 by a gradient elution. The detection utilized selected ion monitoring in the positive ion mode at m/z 251.0 and 344.0 for the protonated molecular ions of olprinone and the internal standard, respectively. The quantitation limit for olprinone in rat plasma was 0.5 ng mL−1. The linearity was also excellent over the concentration range of 0.5–100 ng mL−1 of olprinone. The intra- and inter-day precision (relative standard deviation (RSD) %) was lower than 10%, and accuracy ranged from 90 to 110%. This developed method was successfully applied to analysis of olprinone in biological fluids.  相似文献   

12.
A rapid, simple and specific liquid chromatography-electrospray ionization mass spectrometry method has been developed and validated for the determination of hydroxyzine hydrochloride in human plasma. Samples were separated using a Thermo Hypersil-HyPURITYC18 reversed-phase column (150 mm × 2.1 mm i.d., 5 μm). The mobile phase consisted of 50 mM ammonium acetate (pH 4.0)–methanol–acetonitrile (45:36:19, v/v). Hydroxyzine and its internal standard were measured by electrospray ion source in positive selective ion monitoring mode. The method was validated with a linear range of 1.56–200.0 ng mL−1 and the lowest limit of quantification was 1.56 ng mL−1 for hydroxyzine hydrochloride (r 2= 0.9991). The extraction efficiencies were about 70% and recoveries of the method were in the range of 93.5–104.4%. The intra-day relative standard deviation (RSD) was less than 8.0% and inter-day RSD was within 7.4%. QC samples were stable when kept at ambient temperature for 12 h at −20 °C for 30 days and after four freeze–thaw cycles. The method has been successfully applied to the evaluation of pharmacokinetics and bioequivalence of two hydroxyzine hydrochloride formulations in 12 healthy Chinese volunteers after an oral dose of 25 mg.  相似文献   

13.
The purpose of this investigation was to develop a method for measuring the concentration of octylonium in human plasma. Hydrochloric acid was added to the plasma samples before pretreatment to improve the stability of the octylonium. After liquid–liquid extraction with ethylacetate and isopropanol (10:1), the analytes were separated by chromatography on a reversed-phase C18 column and detected by LC–MS–MS with electrospray ionization–ionization. The coefficient of variation for the precision of the assay was less than 10.1%, and the accuracy ranged from 98.0 to 106.5%. The limit of quantification or sensitivity was 0.2 ng mL−1. This method was validated by measuring octylonium in the plasma of healthy human subjects after administration of a single 120-mg oral dose of octylonium bromide. Thus, a highly sensitive and accurate analytical method was developed to determine the concentration of octylonium in human plasma.  相似文献   

14.
A simple and effective extraction method based on matrix solid-phase dispersion (MSPD) was developed to determine bifenthrin, buprofezin, tetradifon, and vinclozolin in propolis using gas chromatography–mass spectrometry in selected ion monitoring mode (GC–MS, SIM). Different method conditions were evaluated, for example type of solid phase (C18, alumina, silica, and Florisil), the amount of solid phase and eluent (n-hexane, dichloromethane, dichloromethane–n-hexane (8:2 and 1:1, v/v) and dichloromethane–ethyl acetate (9:1, 8:2 and 7:3, v/v)). The best results were obtained using 0.5 g propolis, 1.0 g silica as dispersant sorbent, 1.0 g Florisil as clean-up sorbent, and dichloromethane–ethyl acetate (9:1, v/v) as eluting solvent. The method was validated by analysis of propolis samples fortified at different concentration levels (0.25 to 1.0 mg kg−1). Average recoveries (four replicates) ranged from 67% to 175% with relative standard deviation between 5.6% and 12.1%. Detection and quantification limits ranged from 0.05 to 0.10 mg kg−1 and 0.15 to 0.25 mg kg−1 propolis, respectively.  相似文献   

15.
A sensitive and specific liquid chromatographic method with electrospray ionization mass spectrometry (LC–ESI-MS) has been developed and validated for identification and quantification of mitiglinide in human urine. A simple liquid–liquid extraction procedure was followed by separation on a C18 column with gradient elution, and detection using a single-quadrupole mass spectrometer in selected-ion-monitoring (SIM) mode. The method was tested using six different batches of urine. Linearity was established for the mitiglinide concentrations in the range 0.005–1.0 μg mL−1, with a coefficient of determination (r) of 0.9998 and good back-calculated accuracy and precision. Intra- and inter-day precision (as RSD, %) was below 10% and accuracy for mitiglinide ranged from 85 to 115%. The lower limit of quantification was reproducible at 0.002 μg mL−1 for 500 μL urine. The proposed method enables unambiguous identification and quantification of mitiglinide in pre-clinical and clinical studies.  相似文献   

16.
A rapid, sensitive, and simple HPLC–MS–MS method, with electro-spray ionization and cetirizine as internal standard (IS), has been developed and validated for simultaneous quantification of fexofenadine and pseudoephedrine in human plasma. The analytes were isolated from plasma by solid-phase extraction (SPE) on Oasis HLB cartridges. The compounds were chromatographed on an RP 18 column with a mixture of ammonium acetate (10 mm, pH 6.4) and methanol as mobile phase. Quantification of the analytes was based on multiple reaction monitoring (MRM) of precursor-to-product ion pairs m/z 502 → 466 for fexofenadine, m/z 166 → 148 for pseudoephedrine, and m/z 389 → 201 for cetirizine. The linear calibration range for both analytes was 2–1,700 ng mL−1 (r = 0.995), based on analysis of 0.1 mL plasma. Extraction recovery was 91.5 and 80.88% for fexofenadine and pseudoephedrine, respectively. The method was suitable for analysis of human plasma samples obtained 72 h after administration of a drug containing both fexofenadine and pseudoephedrine.  相似文献   

17.
Metabolism of four tobacco-specific N-nitrosamines (TSNAs), N′-nitrosonornicotine (NNN), N′-nitrosoanatabine (NAT), N′-nitrosoanabasine (NAB), and 4-(methylnitrosamino)-1-(3-pyridyl)-1-butanone (NNK) has been studied by solid-phase extraction (SPE) and liquid chromatography–tandem mass spectrometry (LC–MS–MS). 4-(Methylnitrosamino)-4-(3-pyridyl)-1-butanol (iso-NNAL) was used as internal standard. SPE and LC–MS–MS was found to be a rapid, simple, sensitive, and selective method for analysis of TSNAs in rabbit serum. The relative standard deviation (R.S.D., n = 6) for analysis of 5 ng mL−1 and 0.5 ng mL−1 standards and of serum sample spiked with 5 ng mL−1 standards of five TSNAs was 2.1–11% and recovery of 5 ng mL−1 standards from serum was 100.2–112.9%. A good linear relationship was obtained between peak area ratio and concentration in the range of 0.2–100 ng mL−1 for NNAL and 0.5–100 ng mL−1 for other four TSNAs, with correlation coefficients (R 2) >0.99 (both linear and log–log regression). Detection limits for standards in solvent were between 0.04 and 0.10 ng mL−1. Doses of TSNAs administered to rabbits via the auricular vein were 4.67 μg kg−1 and 11.67 μg kg−1, in accordance with the different levels in cigarettes. Metabolic curves were obtained for the four TSNAs and for 4-(methylnitrosamino)-1-(3-pyridyl)-1-butanol (NNAL), a metabolite of NNK; on the basis of these curves we modeled metabolic kinetic equations for these TSNAs by nonlinear curve fitting.  相似文献   

18.
A sensitive and rapid liquid chromatography-electrospray ionization-mass spectrometry (LC-ESI-MS) method has been developed and validated for the determination of mizolastine in human plasma using dipyridamole as the internal standard (I.S.). Plasma samples were simply pretreated with methanol for deproteinization. Chromatographic separation was performed on an Agilent Zorbax C18 column with a mobile phase of 10 mM ammonium acetate buffer containing 0.1% formic acid–methanol (20:80, v/v) at a flow rate of 1 mL min−1. The electrospray ionization (ESI) interface was employed in a single quadrupole mass spectrometer. The analytes were protonated in the positive ESI interface and detected in single ion monitoring (SIM) mode. Chromatographic separation was achieved in less than 3.5 min. The linearity was established over the range of 0.5–600 ng mL−1. The lower limited of quantification (LLOQ) of the method was 0.5 ng mL−1. The intra- and inter-run standard deviations were both less than 11.2%. The method was applied to study the pharmacokinetics of the mizolastine sustained-release tablets in healthy volunteers.  相似文献   

19.
Summary An HPLC method has been developed for the quantification of rantidine in plasma for pharmacokinetic studies. Metoclopramide was used as internal standard. The method uses a simple and rapid sample clean-up procedure involving single-step extraction with organic solvent to extract ranitidine from plasma. After evaporation and reconstitution the samples are chromatographed on a 250 mm×4 mm base-stable reversed-phase column with 0.05 M ammonium acetate-acetonitrile, 75∶25 (v/v) as mobile phase and UV detection at 313 nm. The calibration graph was linear for quantities of ranitidine between 10 and 2000 ng mL−1. Intra- and inter-dayCV did not exceed 11.64%. The quantitation limit was 10 ng mL−1 for human plasma. The applicability of this method for pharmacokinetic studies of ranitidine after oral administration are described. Approximately 90 samples can be processed in 24 h.  相似文献   

20.
Aidi injection is a clinical medicine used in China for the treatment of cancer. Calycosin-7-O-β-d-glucoside is the main effective components of the formulas. In this study, a high performance liquid chromatographic (LC) method was developed to quantify calycosin-7-O-β-d-glucoside in rat plasma using a liquid–liquid extraction and ultraviolet (UV) absorbance detection. LC analysis was performed on a Diamonsil C18 column (200 × 4.6 mm i.d., 5 μm particle size) with isocratic mobile phase consisting of acetonitrile–0.05% phosphoric acid (19.5:80.5, v/v) of a flow rate of 1.0 mL min−1. The linear range was 0.11–17.6 μg mL−1 and the low quantification limit was 0.11 μg mL−1 (S/N = 10). The intra- and inter-day relative standard deviations (RSD) in the measurement of quality control (QC) samples 0.11, 0.22, 1.32 and 8.80 μg mL−1 ranged from 4.1 to 6.3 and 4.3 to 6.2%, respectively. The accuracy was from −6.7 to 4.3% in terms of relative error (RE). Calycosin-7-O-β-d-glucoside was stable in storage at −20 °C for 2 weeks and stable after three freeze–thaw cycles in rat plasma. This method was validated for specificity, accuracy, precision and was successfully applied to pharmacokinetic study of calycosin-7-O-β-d-glucoside in rat plasma after intravenous administration of Aidi lyophilizer.  相似文献   