首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
In this study, a combination of solid-phase extraction (SPE) and solid-phase microextraction (SPME) has been used to determine chlorobenzenes in air. Analytes were sampled by pumping a known volume of air through a porous polymer (Tenax TA). Then, the adsorbent was transferred into a glass vial and SPME was performed. The quantification was carried out using gas chromatography (GC)-electron-capture detection or GC-MS. Several SPME coatings (100 microm poly(dimethylsiloxane) (PDMS), 75 microm Carboxen (CAR)-PDMS, 65 microm PDMS-divinylbenzene (DVB), 65 microm PDMS-DVB and 85 microm polyacrylate (PA) were evaluated, obtaining the highest responses with Carbowax (CW)- PDMS for the most volatile chlorobenzenes, and with PDMS-DVB or CW-DVB fibers for the semivolatile compounds. To optimize some other factors that could affect the SPME step, a factorial design was used. Kinetic studies of the SPME process were also performed. Concerning the SPE step, breakthrough was studied, showing that 2.5 m3 of air could be processed without losses of the most volatile compounds. The performance of the method was evaluated. External calibration, which does not require the complete sampling process, demonstrated to be suitable, obtaining good linearity (R2 > 0.99) for all chlorobenzenes. Recovery studies were performed at two concentration levels (4 and 40 ng/m3), obtaining quantitative recoveries (>80%). Limits of detection at the sub ng/m3 were achieved for all the target compounds.  相似文献   

2.
In the present work, a simple and fast methodology has been developed for the analysis of chlorotoluenes in water samples using solid-phase microextraction (SPME) coupled to gas chromatography-tandem mass spectrometry (GC/MS/MS). A multifactorial experimental design strategy was used for studying the influence on extraction yield of factors such as fiber coating, extraction mode, temperature, and addition of sodium chloride. Quantitative recoveries (>/=84%) and satisfactory precision (relative standard deviations (RSD)相似文献   

3.
Wang G  Tang H  Chen D  Feng J  Li L 《色谱》2012,30(2):135-140
建立了香水中5种合成麝香的顶空固相微萃取-气相色谱-质谱联用分析方法。实验选用65 μm的聚二甲基硅氧烷-二乙烯基苯(PDMS-DVB)萃取纤维,在磁力搅拌600 r/min条件下,考察了萃取温度、平衡时间、萃取时间、解吸时间、进样口温度和盐效应6个方面对实验结果的影响。优化后的条件为: 10 mL顶空瓶中加入适量用水稀释过的样品,于60 ℃平衡3 min后,顶空萃取20 min,随即插入气相色谱进样口,于250 ℃解吸3 min进行定性、定量分析。5种合成麝香在0.05~1.00 μg/g范围内线性关系良好,检出限(LOD)为0.6~2.1 ng/g。空白样品在3个浓度加标水平下(0.05, 0.50, 1.00 μg/g)的回收率为82.0%~103.3%,相对标准偏差(RSD)为1.8%~9.4%。本方法简便、准确、快速、灵敏,适用于香水中合成麝香的分析检验工作。  相似文献   

4.
A novel analytical method using fast gas chromatography combined with surface acoustic wave sensor (GC/SAW) has been developed for the detection of volatile aroma compounds emanated from lilac blossom (Syringa species: Syringa vulgaris variginata and Syringa dilatata). GC/SAW could detect and quantify various fragrance emitted from lilac blossom, enabling to provide fragrance pattern analysis results. The fragrance pattern analysis could easily characterize the delicate differences in aromas caused by the substantial difference of chemical composition according to different color and shape of petals. Moreover, the method validation of GC/SAW was performed for the purpose of volatile floral actual aroma analysis, achieving a high reproducibility and excellent sensitivity. From the validation results, GC/SAW could serve as an alternative analytical technique for the analysis of volatile floral actual aroma of lilac. In addition, headspace solid-phase microextraction (HS-SPME) GC-MS was employed to further confirm the identification of fragrances emitted from lilac blossom and compared to GC/SAW.  相似文献   

5.
A solid-phase microextraction method (SPME) for determining trace levels of synthetic musk fragrances in residual waters has been developed. Six polycyclic musks (cashmeran, phantolide, celestolide, traseolide, galaxolide and tonalide), and a macrocyclic musk (ambrettolide) have been analysed. A detailed study of the different parameters affecting the extraction process is presented. The main important factors affecting the microextraction process have been studied and optimised by means of a categorical factorial design. Two extraction modes (direct SPME and headspace SPME) were tried at different extraction temperatures using four different fiber coatings [polydimethylsiloxane (PDMS), Carboxen (CAR)-PDMS, PDMS-divinylbenzene (DVB) and Carbowax (CW)-DVB]. An extraction temperature of 100 degrees C sampling the headspace over the sample using CAR-PDMS or PDMS-DVB as fiber coatings were found to be the experimental conditions that lead to a more effective extraction. The method proposed is very simple and yields high sensitivity, with detection limits in the low pg/ml, good linearity and repeatability for all the target compounds. The total analysis time, including extraction and GC analysis, was only 45 min. The optimised method performed well when it was applied to waste water from an urban treatment plant.  相似文献   

6.
A fast method was developed for the extraction and analysis of volatile organic compounds, including disinfection by-products (DBPs), with headspace solid-phase microextraction (HS-SPME) and gas chromatography/mass spectrometry (GC/MS) techniques. A GC/time-of-flight (TOF)-MS instrument, which had fast acquisition rates and powerful deconvolution software, was used. Under optimum conditions total runtime was 45s. Volatile organic compounds (VOCs), including purgeable A and B compounds (listed in US Environmental Protection Agency method 624), were identified in standard water samples. Extraction times were 1min for more volatile compounds and 2min for less volatile compounds. The method was applied to the analysis of water samples treated under different disinfection processes and the results were compared with those from a liquid-liquid extraction method.  相似文献   

7.
This paper describes the optimization of solid-phase microextraction (SPME) conditions for three different fibres (Carboxen-polydimethylsiloxane (CAR-PDMS), divinylbenzene-Carboxen-polydimethylsiloxane (DVB-CAR-PDMS) and polydimethylsiloxane-divinylbenzene (PDMS-DVB)) used to determine trihalomethanes (THMs) in water by headspace solid-phase microextraction and gas chromatography (HS-SPME-GC). The influence of temperature and salting-out effect was examined using a central composite design for each fibre. Extraction time was studied separately at the optimum values found for temperature and sodium chloride concentration (40 degrees C and 0.36g mL-1). The HS-SPME-GC-MS method for each fibre was characterised in terms of linearity, detection (LOD) and quantification (LOQ) limits and repeatability. The fibre PDMS-DVB was selected as it provided a broader linear range, better repeatability and lower detection and quantification limits than the others, particularly CAR-PDMS fibre. The accuracy of the proposed method using the PDMS-DVB fibre was checked by a recovery study in both ultrapure and tap water. A blank analysis study showed the absence of memory effects for this fibre. The reproducibility (expressed as a percentage of relative standard deviation) was 6-11% and the detection limits were between 0.078 and 0.52microgL-1 for bromoform and chloroform, respectively. Finally, the method was applied to determine THM concentration in two drinking water samples.  相似文献   

8.
This study develops a method for the analysis of biocides Irgarol 1051 and Sea Nine 211 in environmental water samples, using solid-phase microextraction (SPME). Their determination was carried out using gas chromatography with flame thermionic (FTD), electron-capture (ECD) and mass spectrometric detection. The main parameters affecting the SPME process such as adsorption-time profile, salt additives and memory effect were studied for five polymeric coatings commercially available for solid-phase microextraction: poly(dimethylsiloxane) (100 and 30 microm), polyacrylate, poly(dimethylsiloxane)-divinylbenzene (PDMS-DVB 65 microm) and Carbowax-divinylbenzene (65 microm). The method was developed using spiked natural waters such as tap, river, sea and lake water in a concentration range of 0.5-50 microg/l. All the tested fiber coatings have been evaluated with regard to sensitivity, linear range, precision and limits of detection. Typical RSD values (triplicate analysis) in the range of 3-10% were obtained depending on the fiber coating and the compound investigated. The recoveries of biocides were in relatively high levels 60-118% and the calibration curves were reproducible and linear (R2>0.990) for both analytes. The SPME partition coefficients (Kf) of both compounds were also calculated experimentally in the proposed conditions for all fibers using direct sampling. Finally the influence of organic matter such as humic acids on extraction efficiency was studied, affecting mostly Sea Nine 211 uptake by the fiber. Optimum analytical SPME performance was achieved using the PDMS-DVB 65 microm fiber coating in ECD and FTD systems for Sea Nine 211 and Irgarol 1051, respectively.  相似文献   

9.
In this paper, hydroxy-terminated silicone oil-butyl methacrylate-divinylbenzene (OH-TSO-BMA-DVB) copolymer was first synthesized and used as stationary phase with the aid of γ-methacryloxypropyltrimethoxylsilane (KH-570) as bridge in solid-phase microextraction (SPME) using sol–gel method and cross-linking technique. It has high extraction efficiency for both polar alcohols and fatty acids and nonpolar esters in comparison with commercial PDMS, PDMS-DVB and PA fibers. A simple and sensitive headspace SPME-gas chromatography (HS-SPME-GC) method using the novel fiber was presented for the simultaneous analysis of both polar alcohols and fatty acids and nonpolar esters in wine. To check the matrix effects, various model wine matrices, including distilled water; 11.5% ethanol/water (v/v) solution; a concentrated synthetic wine; a ‘volatile-free’ wine and a real wine were investigated in detail. Matrix effects were compensated for by using internal standard method and selecting the ‘volatile-free’ wine as working standard. The method presented in this study showed satisfactory linearity, precision, detection limits and accuracy. The recoveries obtained ranged from 85.87 to 104.2%, and the relative standard deviation values were below 9%. The results obtained indicated that the present method is a validated and accurate procedure for the simultaneous determination of both polar and nonpolar aroma compounds in wine.  相似文献   

10.
利用C18固相萃取膜与气质联用(GC-MS)技术建立了瓶装饮用水中27种痕量化合物多残留同时检测的方法.水中被测物多残留通过C18固相萃取膜富集,丙酮洗脱,旋转蒸发与吹氮浓缩,GC/MS选择离子监测模式(SIM)测定.被测物加标回收率在60%~120%之间,相对标准偏差小于25%.  相似文献   

11.
This paper proposes a multiple headspace solid-phase microextraction (MHS-SPME) method coupled to gas chromatography-tandem mass spectrometry detection (GC/MS/MS) for the simultaneous determination of 2,4,6-trichloroanisole, 2,3,4,6-tetrachloroanisole, pentachloroanisole, 2,4,6-tribromoanisole, 4-ethylphenol, 4-ethylguaiacol, 4-vinylphenol and 4-vinylguaiacol in wines. These compounds are involved in the presence of "cork taint" and Brett character in wines. The MHS-SPME method is a modification of SPME developed for quantitative analysis that avoids possible matrix effects based on an exhaustive analyte extraction from the sample. After demonstrating the existence of matrix effect in the analysis of the target compounds by HS-SPME with a divinylbenzene/Carboxen/polydimethylsiloxane (DVB/CAR/PDMS) fibre, the MHS-SPME method was developed and validated. The proposed method showed satisfactory linearity, precision and detection limits, all below the odour detection thresholds of the compounds in wine matrices. Good recoveries were observed for all compounds, always above 90%, and the repeatability obtained was considered acceptable, ranging between 2 and 11%. After checking the applicability of the method by comparing the results recorded with those obtained with the standard addition method, the method was applied successfully to the analysis of wine samples. To our knowledge, this is the first time that MHS-SPME combined with GC/MS/MS has been applied to simultaneously determine haloanisoles and volatile phenols in wine.  相似文献   

12.
The feasibility of solid-phase microextraction (SPME) for the determination of several organophosphorus flame retardants and plastizicers in water samples by gas chromatography-nitrogen phosphorous detection (GC-NPD) is evaluated. These compounds have a wide range of polarities and volatilities and require a thorough optimisation of the different SPME parameters. Considering also possible contamination and carryover sources, the best compromise microextraction conditions were found to be direct extraction of 22 ml samples, containing 300 mg/ml of NaCl, with a PDMS-DVB coated fibre at room temperature. Although equilibrium was not achieved, an extraction time of 40 min allowed obtaining a good sensitivity (quantification limits between 0.010 and 0.025 ng/ml), comparable to that achieved by solid-phase extraction (SPE) of 1l samples, producing both similar values of precision and accuracy. Furthermore, the SPME method has shown to be free of matrix effects, avoiding the need of employing the standard addition procedure for quantification, and was suitable for the determination of eight of the nine considered compounds. Only tris-(2-ethylhexyl)-phosphate was neither determinable by SPME nor by SPE. Finally, the application of the developed methodology to the analysis of wastewater samples, showed that important concentrations of these compounds (up to 10 ng/ml) have been detected in treated sewage water, being discharged into the aquatic environment.  相似文献   

13.
Despite the continuing development of SPME (solid-phase microextraction) fibre coatings, their selection presents some difficulties for analysts in choosing the appropriate fibre for a certain application. There are two distinct types of SPME coatings available commercially. The most widely used are poly(dimethylsiloxane) (PDMS) and poly(acrylate) (PA). Supelco has developed new mixed phases consisting of porous polymer particles, either poly(divinylbenzene) (DVB) or Carboxen suspended in a matrix of PDMS or Carbowax for extracting analytes via adsorption. In addition to the nature of the extracting phase, the thickness of the polymeric film must be taken into account and, surprisingly, the construction of the fibres when apparently they bear the same coating, as it is the case of the three PDMS-DVB fibres available. Other fibre structure properties not well explored were identified and must be taken into consideration. To elucidate their extraction efficiency, three PDMS-DVB fibres, namely 60 microm for HPLC use, 65 microm for GC use and 65 microm StableFlex for GC use, were compared with regard to the extraction of 36 compounds included in four pesticide groups. The first was particularly suited for the extraction of organophosphorus pesticides and triazines whereas the StableFlex exhibited advantages in the analysis of organochlorine pesticides and pyrethroids. An explanation for the extraction differences is suggested based on the different structure of the fibres. Detection limits in the range of 1-10 ng/l for organochlorine pesticides, 1-30 ng/l for organophosphorus pesticides, 8-50 ng/l for triazines and 10-20 ng/l for pyrethroids were attained in a method using the 60 microm PDMS-DVB fibre. The fibre maintains its performance at well above 100 extractions with between-day precision below 10%.  相似文献   

14.
姚桂燕  观文娜  许峰  王华  关亚风 《色谱》2008,26(5):590-594
应用自制的聚醚砜酮(PPESK,30 μm)涂层纤维,采用顶空固相微萃取-气相色谱法测定水中痕量的酚类化合物。优化了固相微萃取温度、萃取时间、pH值和离子强度。方法的检出限为0.003~0.041 μg/L,相对标准偏差低于16%(n=5)。将PPESK涂层纤维与商品化的聚丙烯酸酯涂层纤维对比,结果表明PPESK萃取酚类化合物有较高的萃取富集倍数。用所制备的PPESK萃取头分析自来水、海水等实际水样,20 μg/L添加水平下的回收率分别为100.5%~111.8%和94.8%~117.3%。  相似文献   

15.
A common sample preparation procedure capable of efficiently concentrating various groups of pesticides, taking advantage of universal detectors like the mass spectrometer or combined techniques of group selective detectors like gas chromatography-electron capture detection (ECD)/thermionic specific detection (TSD), is desirable in environmental analysis. Six solid-phase microextraction fibres available for analysis of semi-volatiles (7, 30 and 100 microm poly(dimethylsiloxane) (PDMS), 85 microm polyacrylate, 60 microm PDMS-divinylbenzene (PDMS-DVB) and 65 microm Carbowax-DVB) were evaluated and the 60 microm PDMS-DVB was selected for the simultaneous extraction of 34 compounds, included in the organochlorine (OCPs), organophosphorous (OPPs), pyrethroid and triazine pesticide groups. All parameters affecting the extraction efficiency from water samples, namely fibre coating, sample agitation, pH and ionic strength, extraction temperature and time, were optimised. The analytical procedure involves solid-phase microextraction extraction, gas chromatographic separation and subsequent ECD and TSD via a post-column splitter adjusted to a split ratio of 1:10, respectively. Detection limits in the range of 1-10 ng l(-1) for OCPs, 1-30 ng l(-1) for OPPs, 20-30 ng l(-1) for pyrethroids and 8-50 ng l(-1) for triazines are easily attainable with the optimised procedure. The method validated for ground and drinking waters has low cost of implementation and operation although it requires careful maintenance.  相似文献   

16.
A solid-phase microextraction method has been developed for the determination of 19 chlorophenols (CPs) in environmental samples. The analytical procedure involves direct sampling of CPs from water using solid-phase microextraction (SPME) and determination by liquid chromatography with electrochemical detection (LC-ED). Three kinds of fibre [50 microm carbowax-templated resin (CW-TPR), 60 microm polydimethylsiloxane-divinylbenzene (PDMS-DVB) and 85 microm polyacrylate (PA)] were evaluated for the analysis of CPs. Of these fibres, CW-TPR is the most suitable for the determination of CPs in water. Optimal conditions for both desorption and absorption SPME processes, such as composition of the desorption solvent (water-acetonitrile-methanol, 20:30:50) and desorption time (5 min), extraction time (50 min) and temperature (40 degrees C) as well as pH (3.5) and ionic strength (6 g NaCl) were established. The precision of the SPME-LC-ED method gave relative standard deviations (RSDs) of between 4 and 11%. The method was linear over three to four orders of magnitude and the detection limits, from 3 to 8 ng l(-1), were lower than the European Community legislation limits for drinking water. The method was applied to the analysis of CPs in drinking water and wood samples.  相似文献   

17.
In this study, an extraction and preconcentration technique using solid-phase extraction (SPE) along with hollow fiber (HF) has been developed as an ultra-preconcentration technique for some triazole pesticides in aqueous samples. Triazole pesticides were employed as model compounds to assess the method and were monitored by gas chromatography-flame ionization detection (GC-FID). Initially, an aqueous solution of target analytes was passed through an RP-8 SPE cartridge and then the adsorbed analytes were eluted with μL amounts of toluene. The collected elute was slowly introduced into an HF that had one end blocked. This allowed precipitation inside the lumen and pores of the HF. Finally, the obtained HF was mounted on a home-made solid-phase microextraction syringe and entered into the GC injection port for thermal desorption-GC analysis. The effect of various experimental parameters including injection port temperature, desorption time, state of HF, washing solvent, elution solvent and its volume, sample volume, etc. were investigated for finding the optimum conditions. The calibration graphs were linear in the ranges of 2-1000 ng/mL (penconazole and hexaconazole), 5-1000 ng/mL (tebuconazole), 15-1000 ng/mL (triticonazole) and the detection limits (LODs) ranged from 0.6 to 4.5 ng/mL. The enhancement factors were in the range of 870-950. The relative standard deviations (RSD%) for five repeated experiments (C=250 ng/mL of each pesticide) varied from 4.5 to 8.7%. The relative recoveries obtained for analytes in grape juice samples, spiked with different levels of each pesticide, were in the range of 87-119%.  相似文献   

18.
霍巨垣  欧阳钢锋  陈丽琼  王欣 《色谱》2016,34(6):615-620
建立了顶空固相微萃取结合气相色谱-质谱联用技术测定玩具中10种可迁移有机锡化合物的方法。玩具材料经0.07 mol/L HCl浸泡2 h后,使用醋酸-醋酸钠缓冲溶液将浸泡液的pH值调至4.7,然后加入四乙基硼化钠将浸泡液中的有机锡化合物乙基化,在振荡条件下用100 μ m聚二甲基硅氧烷(PDMS)纤维进行顶空固相微萃取,萃取完成后将纤维插入气相色谱进样口进行热解吸,使用DB-5毛细管柱对10种有机锡化合物进行分离。10种有机锡化合物的检出限为0.5~5 μg/kg。两个加标水平(0.500 μg/L和5.00 μg/L)下的回收率分别为80.7%~118.7%和86.2%~120.5%,RSD均低于15%。应用该方法测定了玩具可触及材料(包括涂层、织物、塑料、木料)中的可迁移有机锡化合物。该方法简便、快速、灵敏度高,不需使用有毒有机溶剂,绿色环保。  相似文献   

19.
Headspace solid-phase microextraction (SPME) followed by gas chromatography (GC) coupled to pulsed flame photometric detection have been investigated for the simultaneous speciation analysis of 14 organotin compounds, including methyl-, butyl-, phenyl-, and octyltins compounds. The analytical process (sorption on SPME fibre and thermal desorption in GC injection port) has been optimised using experimental designs. Six operating factors were considered in order to evaluate their influence on the performances of a SPME-based procedure. The evaluation of accuracy, precision and limits of detection (LODs) according to ISO standards and IUPAC recommendations has allowed the method to be validated. The LODs obtained for the 14 studied organotins compounds are widely sub-ng(Sn) l(-1). The precision evaluated using relative standard deviation ranges between 9 and 25% from five determinations of the analytes at 0.25-125 ng(Sn) l(-1) concentrations. The accuracy was studied throughout the analysis of spiked environmental samples. These first results show that headspace SPME appears really as attractive for organotins determination in the environment and the monitoring of their biogeochemical cycle.  相似文献   

20.
建立了以丙酮为分散剂、氯苯为萃取剂,采用分散液-液微萃取、气相色谱/选择离子质谱联用测定机械加工水基切削液及其废水中三氯苯的方法。该方法与顶空萃取、液-液萃取和固相萃取结合气相色谱/电子捕获检测法相比,具有线性范围广、富集倍数高、重现性好、操作简便、干扰小等优点。样品中三氯苯的加标回收率为94.7%~104.3%,相对标准偏差为2.3%~7.8%。三氯苯的3种同分异构体1,3,5-,1,2,4-和1,2,3-三氯苯的检出限分别为2.0,6.0和3.0 μg/L。重点探讨了萃取剂和分散剂的种类、体积、萃取时间和盐效应等对三氯苯萃取效率的影响,优化了萃取条件。考察了机械加工水基切削液中常用的添加剂对检测结果的影响,结果表明1.0%的亚硝酸钠和聚乙二醇对三氯苯的检测基本无影响。采用该方法对4种实际样品中的三氯苯进行了测定,其中两个样品中含有三氯苯,质量浓度范围为0.15~1.67 mg/L。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号